Technical specification for SMT PICK & PLACE MACHINE

Similar documents

Simple & Easy Modularity & Availability Reliability & Throughput

A and M Electronics Contract Manufacturing Circuit Board Assembly Avenue Kearny Valencia, Ca (661) or (800)

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

pb tec solutions GmbH, Max-Planck-Str. 11, Alzenau (Germany) Tel.: Fax:

Ultraprint 2000 HiE. Ultraprint 2000 HiE Features MODULAR DESIGN ENSURES SUPERIOR ADAPTABILITY

SMEMA Surface Mount Equtpment Manufacturers Association

Rack C. 25 slots (maximum 50 components) Maximum placement area mm. Standard placement area mm. Rack A

AOI Systems Limited Automated Optical Inspection

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

TrueAlarm Fire Alarm Systems

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

DUKANE Intelligent Assembly Solutions

RIELLO ELETTRONICA. Master HP


PU-USBX. USB over Ethernet Extender OPERATION MANUAL

IR-PRO IR-PRO. Operation Guide. Professional Infrared Code Capture System

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

reflecta Super 8 Scanner

Intel C600 Series Chipset or better on Intel or equivalent OEM motherboard

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

FTDI VCP DRIVER (free) (WIN/MAC/LINUX)

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

New Lenovo IdeaCentre A600 systems with Intel processor technology deliver high-performance computing at a competitive price

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

PowerGem Pro Uninterruptible Power Supply

RPLIDAR. Low Cost 360 degree 2D Laser Scanner (LIDAR) System Development Kit User Manual Rev.1

QCJ5 precision prototyping system

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS

Electron S.R.L. B55 CNC TRAINING MACHINES

Win 7 - STIMA CLS / CMP Driver Installation Quick Guide

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

USER MANUAL V5.0 ST100

TEST CHAPTERS 1 & 2 OPERATING SYSTEMS

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware

User manual DinaSys DTC/DTS and DTC/DTZ

Figure 1. Front and Back of a Computer Case

Video Conference Center Project

1. Desktop Systems: Given below is the clarification and suggested changes.

Bluetooth + USB 16 Servo Controller [RKI-1005 & RKI-1205]

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

1. Open the battery compartment as shown in the image.

XTreme Files OS & Data Backup/Restore User Manual Please read the Instruction manual before using the XTreme Files (F Series) 1.

Transmitter Interface Program

Industrial Batteries / Motive Power Chargers 2100.NET.»For improved efficiency and durability«

Product Description Sheet RB15 200D Gantry Robot Item No

USB 3.0 to HDMI External Multi Monitor Graphics Adapter with 3-Port USB Hub HDMI and USB 3.0 Mini Dock 1920x1200 / 1080p

2100 POS System User Guide

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

Single Channel Loop Detector

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

USER MANUAL Online UPS 1K/2K/3K Rack

ActiView. Visual Presenter Image Software User Manual - English

TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

Computer Hardware and Software:


KIP 2300 HIGH PRODUCTION CCD SCAN SYSTEM

Online UPS. PowerWalker VFI 1000R/1U

2.5" XTreme Files OS & Data Backup/Restore User Manual Please read the Instruction manual before using the XTreme Files (X Series) 1.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

1. Introduction Fixture exterior view Connecting the Robe Universal Interface Software update of the fixture...

PCB Assembly Guidelines for Intersil Wafer Level Chip Scale Package Devices

EXPRESSION OF INTEREST (EOI) 001/ DT

Amcrest 960H DVR Quick Start Guide

UNIT 1 INTRODUCTION TO NC MACHINE TOOLS

SOUND LEVEL METER 94405

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

Digital Photo Bank / Portable HDD Pan Ocean E350 User Manual

GV-Hot Swap Backup Center System (Rev. B) 3U, 16 / 8-Bay

Mirror Mount Video Monitor/Recorder with Front and Rear View Night Cameras PLCMDVR5

The Universal PCB Design Grid System

Series. Laser air Leddura Lexinus Mensa. 70 inch. Smart innovation! When function matters.

Installation and User Guide. RotatIR Automated Rotating Sample Stage Accessory

LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS kva three-phase / single-phase kva three-phase / three-phase.

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

1. Check the Accessories

2200 SERIES COMMON DRIVE PACKAGE Special Capabilities Specification Sheet

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Intel Core i processor. 8 x 3.5-inch SATA 6Gb/s, SATA 3Gb/s hard drive. 1. The system is shipped without HDD.

User Manual 1K/2K/3K Online UPS

EZ DUPE DVD/CD Duplicator

MADRIX NEO Quick Start Guide & User Manual

DAB+ / FM Tuner Model: TU-201

Industrial Bar Code Scanners

DC Electronic Loads 8500 series

Quick Connect. quick - simple - efficient.

Using GIGABYTE Notebook for the First Time

High Density RocketRAID Rocket EJ220 Device Board Data RAID Installation Guide

User Guide. Introduction to 3M Digital Designs. User Guide Contents: Installing 3M Digital Designs Software. Setting up a Plotter

PD 100A. Printing data system

ADVANCES IN AUTOMATIC OPTICAL INSPECTION: GRAY SCALE CORRELATION vs. VECTORAL IMAGING

LCD Drawer User Manual

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

ModS. SIO. USB analog. computer

PreciTrack3D GmbH. PRECI 3D TRACK PRECI 3D GUN PRECI 3D SCAN PRECI 3D ROBOGUN PRECI 3D CONFOCAL PRECI 3D REF Tube Inspection & Measurements PRODUCTS

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

Transcription:

Technical specification for SMT PICK & PLACE MACHINE Annexure I Basic requirement: Fully automatic SMT Pick and place system having following specifications. Sr. SMT PICK & PLACE MACHINE No. 1. PCB Size 75(W)*75(L)mm minimum,450(l)*450(w)mm maximum and thickness 0.5-4.0 mm. 2. PCB edge clearance Minimum 3.2mm 3. Fiducials Min 3 nos. of Fiducials for board recognition. Multiple options of type of Fiducials shall be available 4. Vision recognition Digital Vision system 5. Component recognition a) A suitable vision alignment with lighting system capable of handling component size & packages specified shall be provided. The details of the system with significant features, no. of cameras, type of camera, resolution, vision direction etc, to be furnished. b) Vision system for all the nozzles c) Capability of having vision centring with multi nozzle head for smaller components including CSP, BGAs, and smaller QFPS. 6. Minimum Component size 01005 (10 mil x 5 mil) onwards 7. Lead pitch capability 12mil ( 0.3 mm ) or better 8. Maximum Size of 70mm X 70mm or more Component 9. Packages Chip, MELF, mini MELF, SOT, DPAK, SOIC, PLCC, QFP, BGA, Mini BGA, CSP ODD SHAPE COMPONENTS etc. 10. Component leads J TYPE, GULL WING, BGA 11. BGA a) Ball Pitch- 0.4mm to 2mm or better b) Ball Diameter-0.25mm to 0.63,or better 12. Feeder capacity/machine The machine shall have the capability / compatible to accommodate 120 feeders of 8mm or better including autotray changer. However tray changer should not use more than 30 of 8mm slots. The entire feeder capacity should be available on one single machine. The Bidder shall also indicate the unit rate of all types of feeders separately in price bid as per the list provided. Feeders shall be capable of handling paper and plastic reels 1 13. Type of feeders Electronic intelligent feeders a) Tapes, Stick (vibratory type), Waffle, JEDEC, Bulk, Tray b) Feeders must be intelligent type with auto pitch setting, it should also be adjustable through software. c) Feeders should be capable of communicating with the machine through suitable software to enable process stop on detecting wrong component, feeder maintenance alert, parts running out alert. It should be possible to disable these functions and work in manual mode also. d) Can handle 01005 to 1206 component sizes in common 8mm feeders and accommodate 180, 330, 390mm dia tapes/reels. e) Tape splicing to be supported, required tool to be supplied.

f) Feeders should be rugged, robust and repairable at site. g) Feeders should be identifiable using BAR code scanning. 14. Tray exchanger Tray exchanger with Minimum 10 trays of standard dimension. Tray exchanger shall be preferably on trolly. 15. Feeder mounting Capable of mounting and dismounting feeders directly on the machine online & Offline. 16. No of feeder Minimum 50% of feeder slots shall be on trolly banks/trolleys 17. Feeder compatibility The feeders shall be compatible for usage of plastic and Paper material reels. 18. Feeder position indication Feeder position indication for easy feeder mounting to be provided. 19. Feeder identification for LED indication of feeders for quick change during operation component reel / stick replacement 20. Automatic tape cutters Automatic tape cutters for used tapes to be provided for all the feeders. 21. Automatic nozzle changer Automatic nozzle changer to be provided 22. Nozzles for handling components The Bidder shall provide nozzles for all types of components with the machine. The cost of machine shall also include one extra set of nozzles. Further the bidder shall also indicate the unit rate of all types of nozzles separately in price bid. 23. Net speed throughput (min) IPC9850 Chip 20000cph IPC9850 Fine pitch 3000cph 24. Placement accuracy Chip components : Min 50microns at 3sigma.Better performance shall be preferred Fine pitch components: 35microns at 3 sigma or better. 25. X, Y, Z axis Motion All the drives (x,y,z axis) driving mechanism should be linear motors with lead screw/ball screw linear scale or on magnetic rail drive except conveyor system. 26. Rotational accuracy for +/- 0.05degrees or better for 50mm component size Fine pitch components 27. Conveyor rail adjustment a) Front Fixed and Automatic Rear Adjustable b) provision for manual width adjustment 28. Board feed direction Left to Right 29. Board support Supported from Underside in addition to rails by support pins 30. Clearance for under side Minimum 15 mm components 31. Component co-planarity check Inbuilt System to check for co-planarity of component leads to be quoted as optional. 32. Bad mark sensing Bad mark sensing to be provided for panelled PCB s to prevent component placement on Bad PCB s. 33. No. of nozzles per head To be specified. 34. Rejection rate Less than 0.05% rejection in actual usage to be demonstrated 35. Reject components handling Suitable mechanism for collection of rejected components like trash bins to be provided. 36. Placement head A electrically closed loop feedback both X and Y axis movement X and Y 37. Glue dispensing capability Glue dispensing capability to be quoted as optional 38. System Control/Operation a) Fully automatic computer controlled inline operation 2

required. Required hardware to be supplied along with the machine and it should be of reputed make and latest configuration. b) Programming should be possible with user friendly menu driven software. c) In case of accidental shut down machine should restart from the correct sequence. 39. Placement programming Both offline and online CAD download Manual coordinate entry Teach mode 40. Off line setup for Programming In addition to the machine an offline programming setup of following configuration is to be supplied. The desktop system of DELL/HP make having i7 processor, 1TB HDD, 4GB RAM, CD/DVD writer, USB scroll mouse, keyboard, 19 LED/LCD monitor, 3.0 and 2.0 USB, LAN port, licensed Windows OS etc, with suitable laser printer. Necessary software for offline preparation of data and transfer to the main machine shall be included in the offer. 41. Language English 42. Software library In Built Feeder Library, component library, package library etc. for placement programming 43. Optimization capability The machine program shall be capable of optimizing for best placement rate. 44. Compatibility SMEMA 45. 415V +/-10%, 50Hz, Three Phase. Any Transformer required Power input shall be within the machine itself. 46. The total compressed air requirement volume and quality Compressed air shall be specified. 47. Working Environment Requirement of Air conditioning shall be clearly spelt out 48. Humidity RH 30 % TO 70 % 49. a)emergency stop function with buttons provided at front & Safety & other features rear of the machine b)safety cover to be provided both at front and rear c) Multi colour signal tower to be provided c)the machine shall comply with CE mark specifications d) Monitor & operation keyboard both front & rear 50. Training Free of cost at site in two phases one at the time of commissioning and second after 3 months of commissioning. 51. software / hardware tools Necessary programming hardware and software including Machine optimisation packages shall be supplied along with the machine. (Specify the tools) 52. Documentation Hard copy of manuals comprising: Operator, Installation, and Electrical Drawings. On board technical manuals and tutorials supporting operator functions. CD containing manuals and tutorials. 53. Consumables Consumables for maintenance like lubricants should be supplied with machine. 54. Misc Any parts, Accessories, extra conveyer etc. required to seamlessly integrate the machine in the existing line of Puncom replacing the earlier pick N place shall be included 3

in the bid as part of the machine LIST OF FEEDERS REQUIRED Sr. no Description Qty 1 Tape Feeder 8 mm 100(Single component) 2 Tape Feeder 12 mm 8 3 Tape Feeder 16 mmx8mm 8 4 Tape Feeder 16 mmx12mm 3 5 Tape Feeder 24 mmx12mm 6 6 Tape Feeder 24 mmx16mm 3 7 Tape Feeder 32 mm 1 8 Tape Feeder 44 mm 1 Stick Feeders Sr. no Component Width (adjustable) Component Height Qty (adjustable) 1 6.0 mm to 8.0 mm Upto 3.00 mm 04 2 8.1 mm to 10.0 mm Upto 3.00 mm 04 3 10.1 mm to 15.0 mm Upto 4.00 mm 03 4 15.0 mm and above Upto 6.00 mm 01 4

Technical specification for UPS UPS SL.No. 1. UPS Technology IGBT PWM inverter,3 phase IN/3 phase output, microprocessor controlled, provide load with perfect sinewave voltage, double conversion with inbuilt Isolation transformer and digital display and housed in one single cubicle. 2. Capacity 20 KVA 3. Back up time at running load 30 minutes 4. Input voltage & Freq. 415V +/-15% 5. Output voltage, frequency, total harmonic 6. Battery bank shall have MCCB with UV & OV release contacts 415V +/-1%, 50 +/- 0.05 hz, < 2.5% on liner load, 5% on non liner load To be provided 7. Battery SMF batteries bank of 26AH*12V 8. Transient response output voltage dip=+/-5% 9. Protection shall be provided a) overload and short circuit at output of UPS b) over voltage at output. c) deep discharge at battery terminals 10. Parameters available on LCD a) Voltage output bypass. b) Output current per phase. c) Load % on each phase. d) Battery current voltage, remaining time & total load utilization. e)load KVA & KW on each phase. f) output & bypass frequency 11. UPS shall be provided with MS battery rack, uninyvin cable battery to batteries & battery bank to UPS, comprising of SMF batteries VRLA type of the following makes Exide 12. Acceptable makes of UPS Emerson/Schnider Electric/APC/Liebert 5