If the level is too high, flooding of steam purification equipment can occur.

Similar documents
HC900 Boiler Control. Background. Solution. Application Brief Industry: Manufacturing

Tips for burner modulation, air/fuel cross-limiting, excess-air regulation, oxygen trim and total heat control

Industrial Steam System Process Control Schemes

HC900 for Boiler Control Applications

INCREASING THE EFFICIENCY OF BOILER OPERATION BY CONTROLLING DRUM LEVEL WITH BFP SCOOP OPERATION

IPB-IB ELECTRIC ACTUATORS FOR INDUSTRIAL PROCESS CONTROL INDUSTRIAL STEAM BOILERS. BECK VIDEO Scan w/ Smartphone

Instrumentation and Process Control. Boiler Control. Courseware Sample F0

Retort Control in the Food Industry using the C360

Heating Water by Direct Steam Injection

C. starting positive displacement pumps with the discharge valve closed.

Pressurized Water Reactor B&W Technology Crosstraining Course Manual. Chapter 9.0. Integrated Control System

HITACHI INVERTER SJ/L100/300 SERIES PID CONTROL USERS GUIDE

Dynamic Behavior of BWR

Process Analysis and Control P&ID Handout Page 1 P&ID SYMBOLS. ISA Symbols and Loop Diagrams

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

PROCESS CONTROL SYSTEM DESIGN Process Control System Design. LECTURE 6: SIMO and MISO CONTROL

Chapter 10. Control Design: Intuition or Analysis?

Bristol Series 5453 Indicating Pneumatic Pressure Controllers/Transmitters

Density Measurement. Technology: Pressure. Technical Data Sheet INTRODUCTION. S min =1.0 S max =1.2 CONSTANT LEVEL APPLICATIONS

Liquid level measurement using hydrostatic pressure and buoyancy

A descriptive definition of valve actuators

QNET Experiment #06: HVAC Proportional- Integral (PI) Temperature Control Heating, Ventilation, and Air Conditioning Trainer (HVACT)

How To Clean Up A Reactor Water Cleanup

Water Efficiency. Water Management Options. Boilers. for Commercial, Industrial and Institutional Facilities. Boiler Water Impurities

A simple method to determine control valve performance and its impacts on control loop performance

Introduction. Chapter The Motivation

Air Eliminators and Combination Air Eliminators Strainers

HS-901(A) BASIC STEAM HEATING SYSTEMS

PLC Control Unit for a CSM-C Steam Compact Clean Steam Generator

Efficient model-based leak detection in boiler steam-water systems

In-Line Electronic Flow Switches

PNEUMATIC CONTROLS Selection and Description

SELECTING PRESSURE TRANSMITTERS TO IMPROVE CENTRIFUGAL COMPRESSOR SAFETY & EFFICIENCY

Technical Note 802 Leak Testing of Polyethylene Pipe For Municipal and Industrial Applications Part 1 Pre-Test Considerations

Lambda Tuning the Universal Method for PID Controllers in Process Control

OpEx Advantages + Asset Optimization

Control System Definition

Using Wireless Measurements in Control Applications

5.2. Vaporizers - Types and Usage

GS-General Service Control Valves

EUROTHERM MASTER COMMUNICATIONS 5000 Series with Master Communications for unsurpassed access to process data everywhere

Model 43AP Pneumatic Controller, Style B

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Control of an industrial process using PID control blocks in automation controller

The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions

ADVANCED CONTROL TECHNIQUE OF CENTRIFUGAL COMPRESSOR FOR COMPLEX GAS COMPRESSION PROCESSES

PC BASED PID TEMPERATURE CONTROLLER

FORMATION DAMAGE AND WELL TREATMENT SYSTEM

Boiler Blowdown. Boiler Blowdown Benefits. Best Operating Practices for Boiler Blowdown

LarsLap model C for cutting, milling grinding and lapping seats and flanges on globe, safety and control valves

Guidelines for operation of minimum flow control valves

Applying Pressure Independent Control Valves in H.V.A.C. Systems. A Presentation to: Orange Empire ASHRAE Santa Ana Nov. 17, 2009

PID Tuning Guide. A Best-Practices Approach to Understanding and Tuning PID Controllers. First Edition by Robert C. Rice, PhD

Procon Engineering. Technical Document PELR TERMS and DEFINITIONS

Process Control Primer

APPLIED THERMODYNAMICS TUTORIAL 1 REVISION OF ISENTROPIC EFFICIENCY ADVANCED STEAM CYCLES

FAST METHODS FOR SLOW LOOPS: TUNE YOUR TEMPERATURE CONTROLS IN 15 MINUTES

CALIBRATION PRINCIPLES

APPLICATION-SMART CONTROL

Lecture 24: Oscillators. Clapp Oscillator. VFO Startup

Your Boiler Room: A Time Bomb?

Measurement Products. PID control theory made easy Optimising plant performance with modern process controllers

Belt Tensioning Methods for Small Package Conveyors What s the best solution?

PRODUCT PROFILE FEATURES

Best Practices for Controller Tuning

BB-18 Black Body High Vacuum System Technical Description

Laundry Hot Water Systems

Reliable Pressure Measurement with Remote Diaphragm Seals in Cold Weather Applications

Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district

Sanitary Type Electronic Flow Switches

HOW TO SELECT A LOW VOLUME (L.V ) BOILER

HYRADIX ALPHA 4 PERFORMANCE REVIEW

Device Type Manager (DTM) Basic HART

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

TABLE OF CONTENT

100DHP TM CCI DRAG Control Valve For High Pressure Turbine Bypass

Introduction to Paralleling of LTC Transformers by the Circulating Current Method

Entrained Gas Diagnostic with Intelligent Differential Pressure Transmitter

Using EXCEL Solver October, 2000

Sprinter Fuel Filter Installation

SLIM LINE FUME HOOD MONITOR

Replacing Displacers with Guided Wave Radar

Technical Guide No High Performance Drives -- speed and torque regulation

Electronic Flow Switches

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS

Improved Modern Control Station for High Pressure Bypass System in Thermal Power Plant

BUT PRECAUTIONS MUST BE TAKEN OR SERIOUS BURNS CAN RESULT.

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Closed Loop Pressure Control for the Extrusion Process

STEAM DRUM WATER LEVEL MEASUREMENT

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

Chilled Water System Commissioning: Variable Primary Flow. John D. Villani, P.E. Associate Grumman/Butkus Associates

The Chilled Water and Hot Water Building Deferential Pressure Setpoint Calculation Chilled Water and Hot Water Pump Speed Control

Terminology and Symbols in Control Engineering

Operational Reactor Safety /22.903

Equipment Performance Monitoring

FULL ELECTRICAL LNG PLANTS: HIGHEST AVAILABILITY AND ENERGY EFFICIENCY THROUGH OVERALL SYSTEM DESIGN

Accuracy and Tuning in CNC Machine Tools

Transcription:

Application Guide Control Systems in the Process Industries Control Systems are used extensively throughout the process industries and the Utilities to control the level of boiling water contained in boiler drums on process plant and help provide a constant supply of steam. If the level is too high, flooding of steam purification equipment can occur. If the level is too low, reduction in efficiency of the treatment and recirculation function. Pressure can also build to dangerous levels. A drum level control system tightly controls the level whatever the disturbances, level change, increase/ decrease of steam demand, feedwater flow variations. Suitable ABB products for use in Control systems are: COMMANDER 300 Controller (for single-element systems) COMMANDER 900 Controller (for single, two and three-element systems) MOD 30ML (for single, two and three-element systems) MODCELL ABB Instrumentation

Control Systems in the Process Industries Control Systems In the process industries, boiling water to make steam is a very important procedure. The control of water level is a major function in this process and it is achieved through a water steam interface established in a cylindrical vessel called the drum which is usually lying on its side and located near the top of the boiler. Providing tight water level control in a drum is accomplished by utilizing one of three types of drum level control: single-element, two-element, or three-element. All three types of control strategies can be provided for utilizing one MOD 30ML Controller and supporting field products such as ABB electronic differential pressure transmitters (type 62D) and WEDGE flow elements. The Boiler Drum Maintaining the correct water level in the drum is critical for many reasons. A water level that is too high causes flooding of the steam purification equipment; resulting in the carry over of water and impurities into the steam system. A water level that is too low results in a reduction in efficiency of the treatment and recirculation function. It can even result in tube failure due to overheating from lack of cooling water on the boiling surfaces. Normally drum level is expected to be held within 2 to 5cm of the set-point with some tolerance for temporary load changes. Components Affecting Drum Water Level Under boiling conditions, steam supporting field products such as bubbles exist below the water/steam level interface. These bubbles have volume and therefore displace water to create a misrepresentation of the true water level in the drum. Another effect upon drum level is pressure in the drum. Because steam bubbles compress under pressure (if the drum pressure changes due to load demands), the steam bubbles expand or contract respective to these pressure changes. A higher steam demand will cause the drum pressure to drop, and the steam bubbles to expand to give the appearance of a water level higher than it truly is. This fictitious higher water level causes the feedwater input to be shut down at a time when more water is really required. A surge in water level as a result of the drum pressure decreasing is called 'swell'. A water level decrease due to drum pressure increase is called 'shrink'. Level Control Strategies Figure depicts three types of drum level control strategies with typical applications for each. While single-element drum level control is acceptable for steady boiler load conditions; as load changes become more frequent, unpredictable, or severe; this type of level control cannot respond quickly enough to compensate. More information must be included and processed to predetermine the amount of water to be added to the drum to compensate for load changes. The addition of elements (flow and transmitter devices) enables the controller to predict the amount of water added to the drum to maintain drum level set-point. System Classification Load Change Capabilities Typical Applications Magnitude Rate Single-element Moderate Slow Institutional and industrial heating plants Steady process conditions Two-element Moderate Moderate Industrial plants with essentially continuous type processes and good feedwater pressure regulation Three-element Wide Fast Combination of batch and continuous type operations such that plant steam load characteristics varies continuously and usually unpredictably. Most industrial power applications fall into this category. Figure Application Chart for Control System

Control Systems in the Process Industries Single-Element Drum Level Control Figure 2 depicts the control scheme for single-element drum level control. In this configuration, only the water level in the drum is being measured (hence the term " single element" ). LT- is an electronic differential pressure transmitter with a high static pressure range. The high side of the transmitter is connected to the bottom of the drum. Because of the drum's static pressure, the low side of the transmitter is connected to the top of the drum above the water/steam interface. This provides a reference for the transmitter by cancelling the static pressure effect and allowing only the water hydrostatic head to be measured. A constant head reservoir is required to maintain a consistent head in the reference leg of the transmitter. This is often referred to as a ''wet leg" The output of the electronic DP transmitter is the process Input for the MOD 30ML Controller, (LC-), and the output is then compared to a drum level set-point. Any discrepancy between setpoint and drum level causes an output from the MOD 30ML controller in compensation. Because controller action is reverse, as the drum level Increases, a resultant output signal will decrease to close the feedwater control valve. The output of the Controller is fed to the feedwater control valve (FCV-). If the feedwater valve is pneumatic, an lp (current-to-pressure) converter is required to change the Controller current output to accommodate the pneumatic valve. Note that the response from the controller to the feedwater control valve is reactive; i.e. feedwater is added only in response to a drop in drum level. This type of control is acceptable if steam load changes are not dramatic because the controller can respond well to steady demands. In applications where steam load changes become frequent and unpredictable, a reactive strategy is better suited. This type of system requires more field devices for input. LX Constant Head Reservoir Water/ Interface Water with Bubbles Boiler Drum FCV LT LC FK Controller A M Control Valve Figure 2 Single-element drum level control system

Control Systems in the Process Industries Two-Element Drum Level Control System A two-element drum level control system is capable of providing close adherence of drum level to its set-point under steady-state conditions as well as being capable of providing the required tight control during a transient. Its performance during transient conditions permits its use on many industrial boiler applications. Such applications are characterized by adequately-sized drums used with load changes of moderate rate and degree. These characteristics are usually found in plants with continuous-type processes, and those with mixed heating and processing demands. Caution should be exercised in its use on systems without reasonably constant feedwater pressure. The term 'two-element' is derived from two variables: steam flow and drum level influence on the feedwater valve position. It is often classified as a combination 'feed-forward-feedback' system because the steam flow demand is fed forward as the primary index of the feedwater valve position. The drum level signal becomes the feedback which is used to constantly trim the accuracy of the feed-forward system and provide final control of the water/steam interface in the drum. Refer to Figure 3 for the control scheme of a two-element drum level control. Note the left side of the doted line is identical to that used in single-element control. Additional equipment required for two-element drum level control consists of a steam flow measuring device, a differential pressure transmitter, a square root extractor, a feedwater flow computer and a feedwater flow mode transfer station. At first this may appear like a large investment in order to gain stable drum level control, but as you will see this is not necessarily true. How it works: flow is measured by the steam flow transmitter (FT-), its signal is fed to the feedwater flow computer (FC-) after processing through the square root extractor (FY-). As in the single-element level control, the drum level is measured by the level transmitter (LT-) and its signal is transmitted to the drum level controller (LC- ). In the drum level controller, the process signal is compared to the drum level setpoint, where a required corrective output signal to maintain the drum level is produced. This corrective signal is sent to the feedwater flow computer. The feedwater flow computer combines the signal from the two variables, and produces an output signal to the feedwater control valve (FCV-). Auto/Manual transfer of the feedwater control valve is accomplished via FK-. Nearly all of the load change work is done by the feed-forward system, for example, a pound of feedwater change is made for every pound of steam flow change. The drum level control system is used for compensation only. It is expected that the drum level will be maintained very closely to the set-point value. This is true in spite of the low-to-moderate volume/throughput ratio and a wide operating range. As a result, integral response (reset) is a necessary function in the drum level controller. Using one MOD 30ML Controller, four of the functions in the two-element control scheme are accomplished: level control (LC-), square root extraction (FY-), feedwater flow computation (FC-), and feedwater flow mode transfer (FK-). The MOD 30ML Controller is a multi-functional controller providing level control for LC-. Utilizing the linearization block in the ML will provide the required square root function to obtain a linear signal from the steam flow transmitter. A math block in the Controller enables feedwater flow computations. Finally, a feedwater flow transfer

Control Systems in the Process Industries Two-Element Drum Level Control System station is easily provided for with an operator-accessible Auto/Manual button on the Controller display. Once in manual, the controller output is ramped up or down by an operator using keys on the controller display. Should a totalized steam flow be required, the MOD 30ML Controller provides an eight-digit display of the totalized value. FT- is an ABB electronic transmitter providing accuracy of 0.2% and is rugged enough to handle static pressures up to 6000 PSI. FE Constant Head Reservoir LX FT Flow Water/ Interface Water with Bubbles Boiler Drum LT LC FCV Controller A M FY FC FK Square Root Extractor Flow Computer Flow Mode Transfer Station Control Valve Figure 3 Two-element drum level control system

Control Systems in the Process Industries Three-Element Drum Level Control System In most drum level control applications, the two-element drum level control will maintain the required water/steam interface level even under moderate load changes. However, If an unstable feedwater system exists exhibiting a variable feed header-to-drum pressure differential, or if large unpredictable steam demands are frequent, a three-element drum level control scheme should be considered. As implied from the previous information, this control strategy supplies control of feedwater flow in relationship to steam flow. The performance of the three-element control system during transient conditions makes it very useful for general industrial and utility boiler applications. It handles loads exhibiting wide and rapid rates of change. Plants which exhibit load characteristics of this type are those with mixed, continuous, and batch processing demands. It is also recommended where normal load characteristics are fairly steady; but upsets can be sudden, unpredictable and/or a significant portion of the load. How it works: Figure 4 shows the control scheme for three-element drum level control. To the left of the dotted line, the instrumentation is the same as that for the two-element drum level control, with one exception: the output of the feedwater flow computer now becomes the set-point of the feedwater flow controller (FIC-2). Equipment required to complete our three-element drum level control scheme includes an additional flow device (FE-2) and differential pressure transmitter (FT-2). The area to the left of the dotted line in figure 4 functions the same as that of a twoelement drum level control. We can pick up the operation for this scheme where the output signal of the feedwater flow computer (the combination of steam flow and drum level) enters the feedwater controller (FIC-2). This in effect becomes the set-point to this controller. flow Is measured by the transmitter (FT-2). The output signal of the feedwater flow transmitter is linearized by the square root extractor, (FY-2). This signal is the process variable to the feedwater controller and is compared to the output of the feedwater flow computer (set-point). The feedwater flow controller produces the necessary corrective signal to maintain feedwater flow at its set-point by the adjustment of the feedwater control valve (FCV-). As in the two-element drum level control scheme, nearly all of the work necessary to compensate for load change is done by the feed-forward system (i.e. a pound of feedwater change is made for every pound of steam flow change). The drum level portion of the control scheme is used only in a compensating role. Despite low-tomoderate volume/ throughput ratio and a wide operating range, it is expected the drum level will be maintained very close to set-point. Achieving this requires use of the integrating response and reset in both the drum level and feedwater controllers. This application may suggest that an additional controller is required for the feedwater flow controller, however this Is not true. The MOD 30ML Controller is a multi-loop unit. An easily-configured feed-forward command in the MOD 30ML means no additional wiring is required to have the drum level controller and feedwater controller working together. flow computations are effortlessly done in the maths block of the controller, all square root functions are performed within. The feedwater flow element (FE-2), is an ABB WEDGE unit. A reliable, rugged, yet accurate measuring device that will be in service for many years. Many models include the option of mounting the transmitter on the WEDGE itself, thus eliminating the need for expensive lead lines, valves and flanges.

Control Systems in the Process Industries Three-Element Drum Level Control System The feedwater flow transmitter (FT-2), is an ABB electronic differential pressure transmitter. If the system is appropriately designed. FT-. FT-2, and LT- may be the same type of transmitter. This means stocking only one type of transmitter In the case of a transmitter failure. FE Constant Head Reservoir LX FT Flow Water/ Interface Water with Bubbles Boiler Drum LT LC Controller FY FY 3 Flow Computer Square Root Extractor FCV A M FY 2 FIC 2 FK Flow Mode Transfer Station FT 2 Flow Control Valve FE 2 Flow Element Figure 4 Three-element drum level control system

The Company's policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. ABB 997 (8.97) AG/DLC Issue A DLC#_GG.pdf ABB Kent-Taylor Ltd. St. Neots Cambs. England, PE9 3EU Tel: +44 (0) 480 47532 Fax: +44 (0) 480 27948 ABB Instrumentation Inc. PO Box 20550, Rochester New York 4602-0550 USA Tel: + 76 292 6050 Fax: + 76 273 6207 ABB Kent-Taylor SpA 2206 Lenno Como Italy Tel: +39 (0) 344 58 Fax: +39 (0) 344 56278