Master the elements. Unleash your potential.

Similar documents
Resistance of Plastics to Gamma Irradiation

Effect of Sterilization Techniques on Polymers

Recognised Zebra Printing Systems

No. X ISSUED: APR. 22, 2008 REVISED: MAY. 9, 2009 SERVICE INFORMATION : --- HOSHIZAKI WATER ELECTROLYZER ROX-20TB-E MODEL PARTS LIST

DESIGN IMAGINEERING DESIGNING YOUR PLASTIC PART KEY DEFINITIONS DESIGNING YOUR PLASTIC PART KEY DEFINITIONS IDEAL CONDITIONS IN PART DESIGN

SoC Reporting Guide Rev 16 March 2009

Tiangang TM BW-10LD (622)

Component-Marking and Labeling Systems (PGDQ2)

HIGH-PILED COMBUSTIBLE STORAGE

WORLD PLASTICS MARKET REVIEW. By Bill Kuhlke and Dr. Tom Walsh

HIGH-PILED COMBUSTIBLE STORAGE

Two separate and different methods are used to manufacture the above items:

COMMON INSULATING MATERIALS AVAILABLE FROM PROFESSIONAL PLASTICS

Alcohols. Characterized by OH group Name: add ol. to name of hydrocarbon. Methanol. Butanol. Sterno. Alcohols burn in air. A mixture of ethanol +

OUT SIDE BACK COVER OUT SIDE FRONT COVER

Cautionary Information

MATERIAL ABBREVIATIONS

Biomaterials in tissue engineering

ULTRASONIC THICKNESS GAUGE TT100/110/120/130

KML-450MAF KML-450MWF KML-450MAH KML-450MWH

Plastics the Facts 2015 An analysis of European plastics production, demand and waste data

Back to Basics Fundamentals of Polymer Analysis

Basic Cable Assemblies DELIVERING QUALITY SINCE 1952.

Standard Wire & Cable Co.

What is a mold? Casting. Die casting. Injection Molding Machine. Injection Molding Design & Manufacturing II. Spring 2004

Characterization of Polymers Using TGA

How To Make A Hot Melt Adhesive

DuPont Formacel. FEA-1100 has low vapor thermal conductivity, providing excellent insulation performance.

PLEXUSTM. Guide to Bonding Plastics ITWPLEXUS. To place an order or for more information call

Piping Systems. From design to your turnkey partner

The importance of selecting the

SORTING PLASTICS FOR RECYCLING INTRODUCTION

TECHNO Multi-Purpose Check Valves for Industry

Profiles On Display CERTIFIED ISO 9001:2000. Call Toll Free Canada Montreal

ALLROUNDER 420 C GOLDEN EDITION

CSD carbonated soft drink CTA cellulose triacetate CVD chemical vapor deposition DABCO diazobicyclooctane DAM days after manufacture DAM diallyl

Harsh Environment Connector Material Selection Guide

PRODUCT AND TECHNICAL DATA

Whether plastic, rubber, wood, metal or ceramic,

TABLE OF CONTENTS CHAPTER TITLE PAGE

PET (Polyethylene Terephthalate, Resin Identification Code #1) PET Bottles (Carbonated Beverage, Water, and Custom Bottles)

Lecture 7. Plastic Part Manufacture, Injection Molding Thermosets Examples Unsaturated Polyesters Epoxies and Resins Elastomers

Ethylene Oxide (EtO or EO) The Future Of Gas Sterilization

VHB Tapes. Technical Data November 2015

COMPARISON OF METRICIDE OPA PLUS SOLUTION AND CIDEX OPA SOLUTION USE PROPERTIES

Inspired By Challenge. Technical information polymer characteristics

PROFESSIONAL PLASTICS, INC. Materials for Die Cutting & Stamping of Gaskets, Washers, Bearings, Seals, Graphics, & Insulators

Estimating Power Requirements of Etched-Foil Heaters

GLOBAL MARKETS FOR NON-POLYOLEFIN COMMODITY RESINS

Mainline Pipe Rehabilitation Using Cured-in-Place Pipe (CIPP) & Folded Pipe Technology

Plastics the Facts 2014 An analysis of European plastics production, demand and waste data

PROCESSING OF VARIOUS MATERIALS

An Overview of the Plastic Material Selection Process for Medical Devices

NDP-50 Specifications

Technical Data Sheet February 2014

Ultrasonic Welding. Polymers: Characteristics and Compatibility for Ultrasonic Assembly. Technical Information PW-1

Electronic Materials able to detect, amplify and transmit electrical signals in a complex manner are light weight, compact and energy efficient

Procedure Code A Insulin pen needles A4230 Infusion set for external insulin pump, non needle cannula type A4231 Infusion set for external

DESCRIPTION ASTM 1418 ISO/DIN 1629 Page. SBR Styrene Butadiene Rubber SBR SBR 6. NR Natural Rubber NR NR 6

Anodes and Misc Equipment

INCORPORATING 3D PRINTING INTO YOUR BUSINESS MODEL. Dr Phil Reeves, Vice President of Strategic Consulting

Battery and Plastics recyclingpresent

FTIR and DSC of polymer films used for packaging: LLDPE, PP and PVDC

Cables. Accessories. For Force, Torque and Strain Sensors

Evaluation of HFO-1234yf as a Potential Replacement for R-134a in Refrigeration Applications

Materials Compatibility

Unit 12 Practice Test

APR Design for Recyclability Guidelines Section Excerpt

the runnerless types of molds are explained post molding operations are described the basic methods of applied decoration methods are examined

MATERIAL SAFETY DATA SHEET

Introduction: Consumables - Part of the Identification System

Electrochemical Biosensor Materials

Ningbo Yinzhou Keao Prototyping & Mould Factory Services include : CNC machining prototypes,

Elements of Addition Polymerization. Branching and Tacticity. The Effect of Crystallinity on Properties

Digital inductive conductivity transmitter

CABLE BASICS. Sizing and Selection Standard vs. Custom. Presented by

3M Electrical. OEM Electrical Insulating Tapes

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013

Figure 1. A schematic representation of a PEO coatings: mushroom conformation on the left hand side and brush conformation on the right hand side.

Fueling Export Growth: U.S. Net Export Trade Forecast for Key Chemistries to 2030

LI. Temperature Resistant Polymer Coating Systems for Frying, Cooking and Baking Utensils

SPECIALTY CABLES APPLICATIONS SUPPORTED

NEMA Magnet Wire Thermal Class Ratings

medical application products

MBA Polymers. Richmond, California. Use of Recovered Plastics in the Manufacture of Automobiles, Appliances & Electronic Equipment

BUTTERFLY VALVES API 609 WAFER LUG U-SECTION BODY STYLE DIAPHRAGM VALVES EN13397:2000 WEIR BODY STYLE

Best Available Technology for Sodium Hypochlorite Storage Tanks

Pipe Protection Tape System

BNG 331 Cell-Tissue Material Interactions. Biomaterial Surfaces

Unit X: Polymers Test 1.1

PRECISION PROTOTYPING THE ROLE OF 3D PRINTED MOLDS IN THE INJECTION MOLDING INDUSTRY

Energy saving and environment

Aqueous base containing buffering agents, chelating agents and a corrosion inhibitor %

Electromagnetic pump designation GOTEC

RF & Microwave cable assemblies C291

GaBi Hand Dryer Tutorial

Glossary. 3D Animation Using computer software to create and animate a three-dimensional representation of image data.

PP / PE X X X X (X) X PA (X) X

CHAPTER 1 INTRODUCTION

Transcription:

Master the elements. Unleash your potential. Until now, traditional sterilization methods have restricted your potential. With superior compatibility across a wider range of materials, the REVOX method is changing that.

MATERIALS COMPATIBILITY GUIDANCE Information within this material compatibility guide is not intended to provide a rationale for the use of materials without proper qualification of materials. The information is intended only as a guide to successful material qualification. compatibility guidance Specific materials Thermoplastics Acrylonitrile butadiene styrene (ABS) No change No change after >10 cycles. Polytetrafluoroethylene (PTFE) No change No change after >30 cycles. Perfluoroalkoxy (PFA) No change No change after >30 cycles. Polychlorotrifluoroethylene (PCTFE) No change No change after >10 cycles. Polyvinyl fluoride (PVF) No change No change after >30 cycles. Polyvinylidene fluoride (PVDF) No change No change after >30 cycles. Ethylene tetrafluoroethylene (ETFE) No change No change after >10 cycles. Fluorinated ethylene propylene (FEP) No change No change after >30 cycles. Polyacetals (e.g., polyoxymethylene) No change No change after >30 cycles. Polyacrylates (e.g., polymethylmethacrylate) No change No changes in extractable/ leachable after 4 cycles. Polyamides (e.g., nylon) No change No change after >10 cycles. Styrene-acrylonitrile (e.g., SAN) No change No change after >10 cycles. High density polyethylene (HDPE) No change No change after >30 cycles. Low density polyethylene (LDPE) No change No change after >4 cycles. Tygon No change No change after >10 cycles. Polycarbonate (PC) No change No change after >30 cycles. Polyesters, saturated No change No change after >30 cycles. Polyethylene (PE) No change No change after >30 cycles. Polyimides (e.g., polyetherimide) No change No change after >30 cycles. Polyketones (e.g., polyetheretherketone) No change No change after >30 cycles. Polypropylene (PP) natural No change No change after >30 cycles. Polypropylene (PP) stabilized No change No change after >30 cycles. Polystyrene (PS) No change No change after >10 cycles. Polysulfones No change No change after >30 cycles. Polyurethane (PU) No change No change after >10 cycles. Grade dependent for dehydrogenation cycles only. Polyvinyl acetates (PVA) No change No change after >10 cycles. Polyvinyl chloride (PVC) No change No change after >30 cycles. PVC, plasticized No change No change after >30 cycles. Polyetheretherketone (PEEK) No change No change after >10 cycles. Polyethylene terephthalate (PET) No change No change after >30 cycles. Ethyl vinyl acetate (EVA) No change Weight change after 10 cycles, device tested was foam. Indicates absorption.

compatibility guidance Specific materials (continued) Thermosets Phenolics No change No change after >10 cycles. Polyester, unsaturated No change Peak deletion in FTIR observed after 10 cycles. Polyimides (Kapton) No change No change after >10 cycles. Polyurethanes No change No change after >10 cycles. Adhesives Acrylic No change No change after >10 cycles. Epoxy (non-peroxide cured) Recommend the use of peroxide cured epoxy. Fluoroepoxy Methacrylate No change No change after >30 cycles. Urethane acrylate No change No change after >30 cycles. Silicone No change No change after >30 cycles. Ethyl 2 cyanoacrylate (Loctite 4061) No change No change after >10 cycles. Elastomers Butyl Ethylene propylene diene monomer (EPDM) No change No change after >30 cycles. Natural rubber No change Peak deletion in FTIR after 10 cycles. Nitrile No change No change after >30 cycles. Polyacrylic No change No change after >30 cycles. FKM to Dependent on material grade to Viton to Dependent on material grade to Dependent on material grade. Dependent on material grade. Silicone No change No change after >30 cycles. Kalrez No change No change after >10 cycles. Pebax No change Peak deletion in FTIR observed after 10 cycles. Styrenic block copolymers (e.g., styrene-butadiene-styrene, styrene-ethylene-butylene-styrene) Peak deletion in FTIR Neoprene rubber Peak removed in FTIR observed Peak deletion in FTIR observed after 10 cycles. Peak deletion in FTIR observed after 10 cycles. Urethane No change No change after >10 cycles. Grade dependent. For depyrogenation cycles only. Polydimethylsiloxane (PDMS), uncured No change No change after >10 cycles.

compatibility guidance Specific materials (continued) Metals (E.4.3) Aluminum Bare (7075) No change No change after >30 cycles. Aluminum Alloy Black Anodize (5056) Slight change After >10 cycles, black Aluminum Bare (1100) Slight change Slight change. Aluminum Alloy Black Anodize (1100) Slight change After >10 cycles, black Aluminum Bare (2024) Slight corrosion observed Corrosion observed. Aluminum Alloy Black Anodize (6061) No change After >10 cycles, black Aluminum Bare (6061) No change After >10 cycles, black Aluminum Alloy Black Anodize (5056) Slight change After >10 cycles, black Brass (464) No change No change after >10 cycles. Copper (CA-110) No change Slightly dull after >10 cycles. Gold No change No change after >30 cycles. Magnesium Slight color change Corrosion observed after 5 cycles. Nickel No change No change after >30 cycles. Silver No change Slight color change after >10 cycles. Stainless steel (304) No change No change after >30 cycles. Stainless steel (316) No change No change after >30 cycles. Stainless steel (430) No change No change after >30 cycles. Mild Steel Corrosion observed Corrosion observed. Hastelloy No change No change after >30 cycles. Nitinol No change No change after >10 cycles. Titanium (Grade 2) No change No change after >30 cycles. Chromium No change No change after >10 cycles.

compatibility guidance Specific materials (continued) Ceramics/glasses Aluminum oxides No change New peaks in FTIR observed after 10 cycles. Silica No change No change after >30 cycles. Zirconium oxides No change No change after >10 cycles. Bioabsorbables Tissue and proteins No change after >2 cycles Poly(lactic-co-glycolic acid) (PLGA) [Class 6 implantable] Not tested above 2 cycles No change No change after >10 cycles. Poly(lactic-acid) (PLA) [class 6 implantable] No change No change after >10 cycles. Polyglycolic acid (PGA) No change No change after >10 cycles. Other s Acrylic (acrylate polymer) No change No change after >10 cycles. Cellulosics No change No change after >10 cycles. Printed battery power source No change in voltage nor performance after >2 cycles Not tested above 2 cycles Printed circuit boards No change No change after >30 cycles. Brushed electric motor No change after >2 cycles Not tested above 2 cycles NOTE REVOX Sterilization Solutions provided the information in this table based on unpublished studies conducted in a REVOX Sterilization System. All polymers tested used the following measurements: mass, dimensions, and Fourier transform infrared spectroscopy (FTIR) scans. All metals tested used the following measurements: mass, dimensions, and ASTM-G31-72 (corrosion test).

MAKE IT POSSIBLE. Products Tested Enzyme sensors (glucose sensors) ATP filters (depyrogenation required) Complex tubing sets Blood filters Hemostats Lyophilized proteins Stem cell culture plates Synthetic ligaments Surgical drapes Stents Inflatable prosthetics Fiber optics Silver-coated products Hydrogel Insulin pumps Syringes Drug coatings Heart valves Pre-filled syringes Vials Wound care applicators Microbial culture plates Injectable adhesives Injectable drugs Injectable hormones Combination devices Balloon catheters Catheters Wet decellularized porcine tissue Dry collagen wound dressings Bovine tissue Human tissue Goggles Incontinence devices Wound dressings Artificial joints Surgical markers Needles Surgical tools Endoscope valves Ablation devices Pressure sensors Crime scene materials Electronics Tested Batteries Alkaline Lithium Lithium ion Nickel metal hydride Lithium ion polymer Electrical connectors Electric motors Brushed Brushless RFID tags Fiber optic lights Printed circuit boards Flexible circuits 2015 Mar Cor Purification Inc.. All Rights Reserved. PN 3030745/A REVOX and Make it possible. are registered trademarks of Mar Cor Purification Inc., A Cantel Medical Company REVOX Sterilization Solutions 14605 28th Avenue North Minneapolis, MN 55447