Is more radiation exposure to patients better for diagnostic interpretation in CT scanning?

Similar documents
MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

CT Protocol Optimization over the Range of CT Scanner Types: Recommendations & Misconceptions

Implementation of Cone-beam CT imaging for Radiotherapy treatment localisation.

The disclaimer on page 1 is an integral part of this document. Copyright February 23, 2016 by AAPM. All rights reserved.

Spiral CT: Single and Multiple Detector Systems. AAPM Refresher Course Nashville, TN July 28,1999

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH

Siemens Computed Tomography

Purchasing a cardiac CT scanner: What the radiologist needs to know

Pediatric Hospitals Bring Low-dose CT to the Middle East

Multi-slice Helical CT Scanning of the Chest

Chest CT protocols. Mannudeep K. Kalra, MD, DNB. Dianna D. Cody, PhD. Massachusetts General Hospital Harvard Medical School

CT: Size Specific Dose Estimate (SSDE): Why We Need Another CT Dose Index. Acknowledgements

DOSES TO EYES AND EXTREMITIES OF MEDICAL STAFF DURING INTERVENTIONAL RADIOLOGY PROCEDURES

How To Improve Your Ct Image Quality

Rb 82 Cardiac PET Scanning Protocols and Dosimetry. Deborah Tout Nuclear Medicine Department Central Manchester University Hospitals

M D Anderson Cancer Center Orlando TomoTherapy s Implementation of Image-guided Adaptive Radiation Therapy

Assessing Radiation Dose: How to Do It Right

Practical exercise: Effective dose estimate in CT

Low-dose CT Imaging. Edgar Fearnow, M.D. Section Chief, Computed Tomography, Lancaster General Hospital

Computed Tomography Radiation Safety Issues in Ontario

WHERE IN THE WORLD JILL LIPOTI?

Dose Modulation Technique in CT

IGRT. IGRT can increase the accuracy by locating the target volume before and during the treatment.

Data. microcat +SPECT

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL

Diagnostic Exposure Tracking in the Medical Record

R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

Fundamentals of Cone-Beam CT Imaging

Development of pediatric CT protocols to obtain minimal doses in PET/CT studies a physicists approach.

Moving Forward What does this mean for the Medical Physicist and the Imaging Community?

Sistemas de reducción de dosis en CT para pediatría. Nuevos avances Ángela de Pinto Siemens CT Business Manager

SUBCHAPTER 22 QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS

Staff Doses & Practical Radiation Protection in DEXA

Radiation Protection in Radiotherapy

A d v a n c e d 1 2 8

Tracking Radiation Exposure From Medical Diagnostic Procedures: Siemens Perspectives

Development of SCENARIA New Version Software MEDIX VOL. 62 P.32 P.35

There must be an appropriate administrative structure for each residency program.

kv-& MV-CBCT Imaging for Daily Localization: Commissioning, QA, Clinical Use, & Limitations

State-of-the-Art Technology in Cardiac CT

Prepublication Requirements

SUMMARY OF CURRENT UK LEGISLATION AND GUIDELINES

Low-dose CT for Pulmonary Embolism

DENTAL Cone beam 3D X-RAY SYSTEM with

IAEA HUMAN HEALTH SERIES

In room Magnetic Resonance Imaging guided Radiotherapy (MRIgRT( MRIgRT) Jan Lagendijk and Bas Raaymakers

The AAPM does not endorse any products, manufacturers, or suppliers. Nothing in this publication should be interpreted as implying such endorsement.

Design and Implementation of an Institution-Wide Patient-Specific Radiation Dose

The Possibilities Tomosynthesis Brings to Lung Cancer Screening

Contents. X-ray and Computed Tomography. Characterization of X-rays. Production of X-rays

3/12/2014. Disclosures. Understanding IAC CT Accreditation. Outline. Learning Objectives. Who is the IAC?

X-Rays Benefits and Risks. Techniques that use x-rays


CTVision System. Accurate Imaging for Precise Treatment.

Eye lens dose measurements in Interventional Cardiology

Acknowledgement. Diagnostic X-Ray Shielding. Nomenclature for Radiation Design Criteria. Shielding Design Goal (Air Kerma):

Comparing dose and image quality of a conventional 400 speed class film/screen system with a CR system by assessing pediatric chest examinations

Copyright March 1, 2016 by AAPM. All rights reserved.

Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis

Protocol Management and Review Strategies The MD Anderson Experience

First floor, Main Hospital North Services provided 24/7 365 days per year

U.S. Bureau of Labor Statistics. Radiology Tech

Global Business Unit Address. Siemens Medical Solutions USA, Inc N. Barrington Road Hoffman Estates, IL Telephone:

The disclaimer on page 1 is an integral part of this document. 1. Copyright December 14, 2015 by AAPM. All rights reserved.

What Parents Should Know about the Safety of Dental Radiology.

Corporate Medical Policy

Gamma Knife and Axesse Radiosurgery

GE Healthcare. Revolution EVO. More than just high tech. Higher purpose.

USE OF IONIZING RADIATION IN THE TEACHING OF PHYSICS AND CHEMISTRY

Patient sample criteria for the OPEIR Measures Group are all patients regardless of age, that have a specific CT procedure performed:

Clinic. ED Trauma Trauma Stroke. OR Neuro/Spine. Critical Care. Neuro ENT. Diagnostic. Pediatric. Radiology. Plastics Thoracic. Neuro.

The disclaimer on page 1 is an integral part of this document. Copyright March 1, 2016 by AAPM. All rights reserved.

GE Healthcare. Optima* CT660

The Challenge of CT Dose Records

Recognition. Radiation Survey Objectives. Objectives. Part 1 Documentation Radiation Source Survey Objectives Radiation Detectors Techniques

Patient Doses for CT Examinations in Denmark

Required RS Training Info

Corporate Medical Policy Intensity-Modulated Radiation Therapy (IMRT) of the Prostate

Treating Thyroid Cancer using I-131 Maximum Tolerable Dose Method

CT scanning. By Mikael Jensen & Jens E. Wilhjelm Risø National laboratory Ørsted DTU. (Ver /9/07) by M. Jensen and J. E.

Patient Prep Information

Quality Assurance. The selection of the equipment. Equipment Specifications. Medical Exposure Directive 97/43 Euratom. Quality Assurance Programme

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

Gestión global de la dosis en TC. Sistema de registro y gestión

THORACIC DIAGNOSTIC ASSESMENT PROGRAM (DAP) PATIENT INFORMATION FOR:

The Field. Radiologic technologists take x-rays and administer nonradioactive materials into patients' bloodstreams for diagnostic purposes.

Chest 1: Pulmonary Nodule Follow-up: Low-Dose Helical CT (Unenhanced) (Non-metastatic) Gantry Rotation Time. mas (Reg-Lg) 40-80

American College of Radiology CT Accreditation Program. Testing Instructions

3rd International Symposium of the System of Radiological Protection Seoul, Korea, October 2015

RESPONSE BY THE CEO OF ARPANSA TO THE ADVICE ON MEDICAL RADIATION ISSUES from the RADIATION HEALTH AND SAFETY ADVISORY COUNCIL

SPECT/CT Wrist. Wrist pain 3/27/2012

SWABIK Project. Software Tools for DICOM Media Exchange in Clinical Research: the. SWABIK Project

3 CT Parameters that Influence the Radiation Dose

Department of Radiation Oncology

Acknowledgements. PMH, Toronto David Jaffray Doug Moseley Jeffrey Siewerdsen. Beaumont Hospital Di Yan Alvaro Martinez. Elekta Synergy Research Group

OPTIMIZING PATIENT EXPOSURE TO IONIZING RADIATION (OPEIR) MEASURES GROUP OVERVIEW 2015 PQRS OPTIONS FOR MEASURES GROUPS:

Incidence of Incidental Thyroid Nodules on Computed Tomography (CT) Scan of the Chest Performed for Reasons Other than Thyroid Disease

Quality control tests of diagnostic radiology equipment in Hungary, and its radiation protection aspects

Running head: OBESITY AND MEDICAL IMAGING 1. Obesity and Medical Imaging. November 13, 2012

Transcription:

Is more radiation exposure to patients better for diagnostic interpretation in CT scanning? H.Niiniviita 1, T. Pölönen 2, M.Varpula 1, J. Kulmala 1,4, H. Määttänen 1, H. Järvinen 3, E. Salminen 3,4 1 Department of Radiology, Turku University Hospital, FI-20520 Turku, Finland; 2 Department of Biostatistics, University of Turku, FI-20014 Turku, Finland; 3 STUK-Radiation and Nuclear Safety Authority, PO Box 14, FI-00881 Helsinki, Finland; 4 Department of Oncology and Radiotherapy, Turku University Hospital, FI-20520 Turku

AIM To study association between radiation exposure and necessary quality for diagnostic reading of computed tomography (CT) scans.

Computed tomography unit imaging parameters. *Years in use at the department of Radiology, Turku University hospital LightSpeed 16 (2003-2012)* Max power (kw) 53 55 Plus 4 (1996-2006)* Anode heat storage capacity (MHU) 6.3 5.3 Helical pitches 4 different, 0.5625, 0.9375, 1.375 and 1.75 freely selectable, 0.5-3 Voltage (kv) 80, 100, 120, 140 80, 120, 140 Current (ma) 10-440 50-420 Number of series 3 2 Slice width (mm) 0.63, 1.25, 2.5, 3.75, 5, 7.5, 10 1, 2, 3, 5, 8, 10 Collimation (mm) 0.63-20 1-10 Tube Performix Ultra (tungsten) Dura 502 (TZM, W, Re, Graphite)

Methods The scans were performed using LightSpeed 16 (General Electric) equipped with automatic exposure control (AEC) system and Plus 4 (Siemens Somatom). The scanned region was trunk/whole body with or without contrast. NRPB-SR250 software* was used to determine effective doses and organ doses. The scans with the widest range and highest exposure doses were reassessed by an independent radiologists without knowledge of estimated organ doses and effective doses. *Salminen et al. Radiat Prot Dosimetry. 2012 Dec;152(4):328-33. http://www.hpa.org.uk/publications/radiation/nprbarchive/nrpbsoftware/

Male patients < 40 years Characteristic N, range or % Number of patients 65 Median age, range 28 (16.5 39.4) Seminoma/Non-Seminoma 26/39 (40% - 60%) Waist circumference measured from CT scans, median (range) 89.6 (66.6-126.3) Number of Whole Body CTEs Number of Whole Body CTEs/patient Mean (SD) Patient characteristics at first whole body scan. 279 4.8 (2.7) Number of whole body CTE with contrast -LightSpeed16 -Plus 4 NRPB-SR250 available for CT dose estimates 104 (75.9%) 112 (78.9 %) http://www.hpa.org.uk/publications/radiatio n/nprbarchive/nrpbsoftware/ Public Health England

Patients 279 whole body CT scans were done to 65 male patients < 40 years, in 2000 to 2011 at Turku University Hospital Dept of Radiology. On the average they had 4.8 scans per person. The scanned area usually covered the whole body from lower neck to the symphyse/mid-thigh; in a few cases it started from the outer auditory canal to cover all the neck. Patients were characterized by waist circumpherence, which was 100 cm for large patients.

Dose reconstruction Every patient was given an identification symbol to link patient to images and dose data. For image data tabulation information was gathered: data from the radiology unit where imaging was performed, type of scanner, name of the examination, imaged area, current, rotation time, slice thickness, table feed during one rotation, length of imaged area, number of images, number of rotations and CTDIair. Every examination was given its own identification indicator. The dose data table contained data for each patient: imaged area, equivalent and effective doses and the use of shielding or contrast medium.

Dose calculation The organ doses and effective doses were calculated using NRPB-250-software, which has been designed to estimate the radiation exposure of CT imaging. The software version was 1.4 and the effective dose was calculated using tissue - weighting factors from ICRP 60. Eleven target organs were selected from the 27 organs in the software For each patient, besides the effective dose values, the calculated doses were summed for each organ and entered in the dose data table.

Figure. Effective dose versus waist circumference (WC) by scanner type in whole body examinations.

Re-reading for diagnostic information Re-reading of scans was done with an experienced radiologist (MV) who was unaware of the exposure data. The criteria for comparison between scans were based particularly on the image quality of liver, lymph nodes, lower lungs and bony structures. Special critical consideration was given to liver parenchyma where distinction between normal and abnormal is most depending on scanning noise. Scans with LightSpeed 16 did not have statistically significantly better quality of image compared to Plus 4 (p = 0.437). More scans with unnecessary high exposure for diagnostic evaluation were observed among patients scanned with LightSpeed 16 (30 vs. 15, p=0.037 Mantel Haensel). According to the reader, scans with good/satisfactory were completely of acceptable quality.

Diagnostic re-assessment based on quality of imaging for scans performed for patients with waist circumpherence >100 cm.

Mean effective dose [msv] by device and waist circumference group with and without iv contrast.

Results Significantly higher radiation exposure was observed for larger patients with LightSpeed16 compared to Plus 4, the dose increased with increase in waist circumference of the patients (p<0.0001) and was even higher when contrast was applied. The quality of imaging for diagnostic purpose was reflected in increased radiation exposure. Scans with LightSpeed16 did not have statistically significantly better quality of image compared to Plus 4 (p = 0.437). The highest effective and organ doses were associated with scans exceeding the needs for proper diagnostic reading.

Conclusion High exposure rates were observed in large patients scanned with AEC equipped device with no added value for diagnostic reading. In this materials the AEC system increased the effective dose particularly in oversized patients. High exposure was not always necessary for diagnostic reading qualities. The results indicate a need for careful consideration of the set-up of basic parameters for CTE to avoid unnecessary high exposure for all scanned patients, the exposure being further increased when contrast use is required. Quality reference mas required by the AEC system to adjust ma must be defined by the user.