ProMinent. Operating Instructions DULCOTEST Chlorine Dioxide Sensor Typ CDP 1-mA-2 ppm

Similar documents
Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Dissolved Oxygen Sensors

Milwaukee USER MANUAL

ATL Fuel Level Sender Probes

DISSOLVED OXYGEN PROBE

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

Operator Quick Guide EC SENSOR

Duct Humidity Transmitter

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Hydraulic control unit series

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

For additional information, please visit our website at

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

INVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

Trace Dissolved Oxygen Sensor

MIST DECORATIVE LAMP WITH ESSENTIAL OIL DIFFUSER

Mounting Instructions. Torque Transducer. A en

User Guide Dissolved Oxygen Probes

PART 1 - INTRODUCTION...

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

USEPA Electrode Method Method 8156

OxyGuard. Dissolved Oxygen Probe

SunMaxx Solar Filling Station Operating Instructions

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Mounting instructions. Junction box VKK2R-8 DIGITAL. A en

Subminiature Load Cell Model 8417

GREISINGER electronic GmbH

Electronic Pressure Switch EDS 300

MOUNTING AND OPERATING INSTRUCTIONS

PTU Series Ultrahigh-Purity Pressure Transducers

Submersion/Insertion Toroidal Sensor

Elektromotoren und Gerätebau Barleben GmbH

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

Zenith Solar thermal 4.5m pump station Installation manual

Digital inductive conductivity transmitter

Streaming Potential System (SPT1000, SPD1000)

LUCCI AIRFUSION QUEST II CEILING FAN

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Ozone Sensor. Model 499A OZ CAUTION CAUTION. Instruction Sheet PN 51A-499AOZ/rev.F January 2007

Mini multi-purpose sewing machine

SenTix 950 SenTix 980

93052/1115-V05. C260 User Manual

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

INSTRUCTION MANUAL. Handy Polaris

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

100 Series Maxi Internal Filters. Instruction Manual

ExStik TM ph Waterproof Meters

TT TOYS TOYS - OWNER S MANUAL. We are delighted that you have decided to purchase this TT Toys Toys children s car.

Troubleshooting Salt Generators

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Infrarot-Bewegungsmelder IP44

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Hydraulic Air Riveter. Operation Manual RC197 RC198. Recommend for mass production line industrial area. Page 1

AutoRanging Digital MultiMeter

Please also see 10 golden rules for correct Saniflo installation on

G670 Intermittent Pilot Ignition Controls

Modular I/O System Analog and Digital Interface Modules

Global Water Instrumentation, Inc.

Operators manual Basic water heater

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Manual Ranging MultiMeter

12-Volt Negative Ground Installation Instructions

Vacuum Hair Clipper. 10,000 prize draw. Register online for HC6550. EXTRA year guarantee FREE rewards gallery

T0118 T2118 T3118. Instruction Manual

Line to Refrigerator Ice/Water Dispenser

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Operating Instructions & Maintenance Guidelines for Precision Vaporizers

Combustible Gas Transmitter RK-05

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases

ClikSTAR - Important facts about your new insulin delivery device.

OPERATING INSTRUCTIONS

Private Water Supplies Sampling Manual. A Field Guide

Wind Sensor W-RS485 with RS485 Interface

NESCAFÉ Solution 8/60 Beverage System. Operations Manual

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

DLP-PU/E Instruction Manual

MODEL 970 DISSOLVED OXYGEN METER OPERATING MANUAL

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

LZV585 (B) The 1-cm path is aligned with the arrow on the adapter

CHARGING SYSTEMS INTERNATIONAL

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

Care and use guide. Contents. a handy solution made easy. page

Technical data sheet TDS0070

Electronic Pressure Switch EDS 3000

MANUAL EN 3. Continue to press the MODE-button to combine charging program with charging options.

Luna/200. Luna/275. Ceiling hoist. User instruction. Important - warning. This manual must be read before the Luna is used

Instruction Manual. T3111 T3111L T3111P T3111Ex

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

For the owner. Instructions for use. ecotec. Wall hung room sealed fan assisted condensing boilers

Transcription:

ProMinent Operating Instructions DULCOTEST Chlorine Dioxide Sensor Typ CDP 1-mA-2 ppm Please read the operating instructions through completely before commissioning this equipment! Do not discard! The operator shall be liable for any damage caused by installation or operating errors! Part no. 987548 ProMinent Dosiertechnik GmbH D-69123 Heidelberg Germany BA DT 032 08/08 GB

Publishing Details Publishing details: Operating Instructions DULCOTEST Chlorine Dioxide Sensor CDP ProMinent Dosiertechnik GmbH, 2000 Address: ProMinent Dosiertechnik GmbH Im Schuhmachergewann 5-11 D-69123 Heidelberg Germany Telephone: +49 (6221) 842-0 Fax: +49 (6221) 842-419 info@prominent.com www.prominent.com Subject to technical alterations. Page 2 ProMinent

Table of Contents Table of Contents Instructions for Use... 4 1 About this Sensor... 5 2 Safety... 5 3 Construction and Function... 6 4 Transport and Storage... 7 5 Assembly... 8 6 Installation... 10 7 Operation... 11 7.1 Run-in Period... 11 7.2 Calibration... 11 8 Troubleshooting... 13 9 Servicing... 14 10 Repairs... 14 11 Decommissioning... 15 12 Disposal... 15 13 Ordering Information... 15 14 Complies with Directives and Standards... 16 15 Technical data... 16 ProMinent Page 3

Instructions for Use Instructions for Use This operating instructions manual includes product descriptions in the main text, enumerated points highlighted points and safety guidelines indicated with symbols: CAUTION Could result in lesser injuries or damage to property if safety guidelines are not observed. IMPORTANT Could result in damage to property if safety guidelines are not observed. NOTE Working guidelines. Page 4 ProMinent

About this Sensor / Safety 1 About this Sensor The CDP chlorine dioxide probe is a membrane covered amperometric dual electrode sensor. It is used to determine chlorine dioxide concentrations in water with or without surfactants present. This sensor has been developed for use in bottle washing systems (water containing surfactants, sudden temperature changes). The sensor emits a standard 4-20 ma signal via a two wire interface that is largely unaffected by water flow. Power is also supplied to the sensor via the two-wire interface. 2 Safety Correct use of equipment The sensor may be used only to determine and regulate chlorine dioxide concentrations (ClO 2 ). All other applications and modification of this equipment are forbidden. The sensor is not a safety component! CAUTION The sensor will operate correctly only if used in a purpose-designed ProMinent probe housing assembly (see Assembly). The sensor can be operated only with a DULCOMETER D1C measurement and control device with automatic temperature correction. (Identity code: D1CAxxD12x1xxxxxx or D1CAxxD13x1xxxxxx). There must be free discharge from the probe housing assembly. The supply voltage to the measuring device and the sensor must not be interrupted. After long intervals without power (more than 2 h) the probe should be given a further run-in period and recalibrated (see 7.1 Run-in period and 7.2 Calibration ). IMPORTANT The probe may be assembled, installed, serviced and operated only by appropriately trained and authorised personnel. Check the sensor regularly for dirt, algae growth and air bubbles. (see 8 Troubleshooting ). Observe valid national directives for the maintenance, servicing and calibration intervals. ProMinent Page 5

Construction and Function 3 Construction and Function Construction Function Fig. 1 Sensor construction The CDP chlorine dioxide sensor is a membrane covered dual electrode measurement sensor. It essentially consists of the membrane cap and the electrode shaft. The membrane cap filled with electrolyte forms the measuring chamber. The electrodes in the electrode shaft project into the measurement chamber. The sample water passes over the micro-porous membrane and the gases pass through the membrane into the measurement chamber. The amplifying electronics are situated above the electrodes in the electrode shaft, above which is located the two-wire terminal. An external sensor gauge Pt 100 compensates for temperature influences. The chlorine dioxide passes through the membrane into the measuring chamber and delivers an electron to the collector. The voltage between the collector and reference electrode causes an electrical current to be produced. This current is proportional to the chlorine dioxide content present within the sample. The amplification electronics transform the current into an un-calibrated standard output signal. This is taken up by the two-wire terminal and transmitted to the controller. Cable bush PG-7 threaded connector Adapter 2-wire connector Tensioning ring Electrode shaft Rubber seal Membrane cap Page 6 ProMinent

Transport and Storage 4 Transport and Storage NOTE Sensor must be transported, sent and stored in the original packaging only. Please retain packaging complete with polystyrene parts. Storage Storage and transport temperature 5 to 50 ºC Humidity max. 90 % relative humidity Non-condensing Shelf life of sensor and membane cap in original packaging: 2 years Shelf life of electrolyte: 1 year NOTE If a sensor has been stored for longer than a year, return it to ProMinent for checking or servicing. We cannot otherwise guarantee the safe function and accurate measurement of the device. Contents 1 CDP sensor 1 bottle of electrolyte (100 ml) 1 operating instructions manual 2 replacement membrane caps ProMinent Page 7

Assembly 5 Assembly Adding the electrolyte IMPORTANT The membrane at the lower end of the membrane cap and the electrodes at the lower end of the electrode shaft should not be touched, damaged or brought into contact with greasy substances. The sensor will not otherwise work correctly. If this occurs, install a new membrane cap or return to ProMinent to have the electrodes cleaned. The electrolyte gel is non-toxic and is easily removed from skin/clothing using water. NOTE Carry out the following steps at a washbasin! Electrolyte Fill up to here Assembling the membrane cap Open the electrolyte bottle (included with sensor) and screw on the nozzle. Remove the red cap completely from the nozzle and flip up the end of the nozzle to open. Pull off the protective cover and unscrew the membrane cap from the electrode shaft. Rinse the membrane cap and the electrode with a small amount of electrolyte. Place the lower edge of the nozzle of the electrolyte bottle vertically downwards into the inside the membrane cap without touching the membrane. Fill the membrane cap in one movement up to the start of the thread with electrolyte (see drawing), keep the nozzle in the electrolyte all the time. A few very small bubbles may form. Check that the membrane is fully wetted - the previously white membrane will darken. If necessary, wait a while. Repeat filling if the membrane fails to go dark. Locate the electrode shaft vertically onto the filled membrane cap and turn until the thread bites. Turn the electrode shaft until the small hole below the rubber seal is visible at the top. Slowly tighten the membrane cap by hand (do not hold the rubber seal!). The membrane must not be allowed to distort under the internal pressure otherwise it will be unusable. Excess electrolyte should drain out of the small hole below the seal as the sensor is screwed together. Hands and sensor should be rinsed thoroughly in cold water in order to remove excess electrolyte. Page 8 ProMinent

Assembly Inserting the sensor IMPORTANT The sensor must be mounted in a CDP probe housing assembly as shown in the diagram (see also 15 Technical Data ). The sensor must be slowly inserted into or withdrawn from the DGM in-line probe housing assembly (4). The membrane could otherwise be damaged. Do not touch the in-line probe housing assembly flow resistor with the membrane. The sensor must be kept wet at all times once commissioned - e.g. the in-line probe housing assembly must not be allowed to run dry. NOTE On bottle washing machines an isolation valve should be mounted directly onto the probe sampling water extraction point. It should only be possible to open this valve when the bottle washing machine is in a normal operating status. When the machine is undergoing cleaning processes, the valve should remain closed. This prevents highly concentrated anti-scalant chemicals from coming into contact with the sensor. Install the sensor as described in the operating instructions of the in-line probe DGM. 2 1 3 4 5 1 Isolation valve 4 DGM 2 In-line flow housing 5 Sampling tap 3 DLG III ProMinent Page 9

Installation 6 Installation IMPORTANT The probe is not electrically isolated from the sample water. Ensure that it is electrically insulated against all other elements. The controller must be insulated both against the sensor and from the supply voltage. The sensor incorporates a passive 4-20 ma two wire interface, i.e. the power is supplied externally, e.g. via the controller. The sensor must be used only when connected to a DULCOMETER D1C controller with automatic temperature correction. (Corresponding identity code: D1CAxxD12x1xxxxxx or D1CAxxD13x1xxxxxx). Do not switch off the measuring system when in intermittent use. If necessary, dosing equipment should be timer-controlled. Electrical installation Rotate the sensor adapter anticlockwise through 90º and pull off (bayonet fitting). Unscrew the PG-7 threaded connector tensioning screw and insert the signal cable from the controller. Strip the ends of the cable and attach to the 2-wire terminal: 1 = plus, 2 = minus. Insert approx. 5 cm of signal cable into the sensor and tighten the PG-7 threaded connector tensioning screw. Push the sensor adapter right into the housing and twist in a clockwise direction until you reach the stop taking care not to damage the bayonet fitting. Page 10 ProMinent

Operation 7 Operation IMPORTANT 7.1 Run-in Period Do not switch off the measuring system during interval operation! After operation without chlorine dioxide, running-in periods are to be rockoned with. If required, switch on metering unit time-delayed! If no chlorine dioxide is metered for a longer period of time, the sensor must be disconnected from the power supply and stored dry. The sensor requires a run-in period before it will display stable readings. First commissioning: 4-12 h Re-commissioning: 2-4 h Membrane-/electrolyte replacement: approx 1 h 7.2 Calibration The sensor can be calibrated after the run-in period. IMPORTANT A slope test must be carried out after replacing the membrane cap or electrolyte. Slope tests must be carried out at regular intervals to ensure correct functioning of the sensor. When used in bottle washing machines it may be necessary to recalibrate the sensor every week or even more frequently. Avoid incorrect dosing due to air bubbles in the sample water. Air bubbles clinging to the sensor membrane can result in a measured variable that is too low and thus lead to incorrect dosage. Observe applicable national directives for calibration intervals. Preconditions The sensor has been run in (see 7.1 Run-in Period ) Constant flow through in-line probe housing assembly (see 15 Technical Data ) Constant sample water temperature Similar sample water and sensor temperatures (wait approx. 15 min.) ProMinent Page 11

Operation Zero point calibration If a ProMinent controller is being used to operate the sensor, zero point calibration is only usually necessary the first time the equipment is commissioned. Zero point calibration should be carried out, however, if operating the sensor in the lower measurement range. Immerse the sensor in a container of clean, ozone, chlorine and ClO 2 -free water. Stir with the sensor until the measured variable displayed at the controller has remained stable for 5 min. Calibrate the controller to zero in accordance with the operating instructions. Reinstall the sensor in the in-line probe housing assembly. Slope test NOTE For bottle washing machines, carry out calibration only after a relatively long period of trouble-free operation or if the bottle washing machine is left to stand (ClO 2 concentration remains constant). Since ClO2 breaks down rapidly it is important that the sensor is calibrated equally rapidly. If a mobile measuring device is not available, please observe the following: Carry out the reaction of the sample water with the DPD-1 reagent directly at the bottle washing machine: then send the probe to the laboratory as fast as possible for measuring. Determine the chlorine dioxide content in the sample water using an appropriate measurement device (e.g. Photometer DT 1). Enter the resulting value into the controller in accordance with the operating instructions. Repeat calibration after 1 day. Page 12 ProMinent

Troubleshooting Fault The sensor cannot be calibrated - measuring device/ controller display value is greater than DPD-1 measurement The sensor cannot be calibrated - measuring device/ controller display value is smaller than DPD-1 measurement Measured variable value is zero Measured variable display unstable 8 Troubleshooting Possible cause Run-in period too short Membrane cap damaged Interference from water contaminants (see 15 Technical Data, Cross-Sensitivity ) Short circuit in signal cable Outdated DPD chemicals Run-in period too short Membrane cap deposits Sample water flow inadequate Air bubbles on the outside of the membrane Reference electrode spent (shiny patches appearing) No electrolyte in membrane cap Electrolyte is penetrating sample water via gas bubbles Interference from water contaminant (see 15 Technical Data, Cross-Sensitivity ) ClO 2 content below the lower measuring range limit Sensor incorrectly connected to controller Air bubbles on the outside of the membrane Membrane damaged Cause lies with the controller Remedy See 7.1 Run-in period Replace membrane cap. Run-in sensor, calibrate Identify interfering contaminant and implement remedy Identify short circuit and repair Use new DPD chemicals, repeat calibration See 7.1 Run-in period Remove deposits (see 9 Servicing ). Replace membrane cap. Run-in sensor, calibrate Increase flow (see 15 Technical Data ) Tap to remove air bubbles and increase flow if necessary Return sensor to ProMinent Add new electrolyte (see 5 Assembly, 7.1 Run-in Period and 7.2 Calibration ) Discuss with ProMinent Identify contaminant and replace water if necessary Add ClO 2 and then repeat calibration or use appropriate sensor Connect sensor correctly to controller Tap to remove air bubbles and increase flow if necessary Replace membrane cap. Run-in sensor, calibrate Identify cause and remedy ProMinent Page 13

Servicing / Repairs 9 Servicing IMPORTANT The sensor must be regularly serviced in order to avoid exceeding dosage due to sensor failure. Observe applicable national directives for service intervals. Service intervals daily / weekly depending upon application. Servicing tasks Check the sensor display value on the controller using an appropriate chlorine dioxide measuring system (e.g. Photometer DT 1: observe note in 7 Operation/Calibration ). If necessary recalibrate the sensor (see 7.2 Calibration ). Check the DLG cup at regular intervals for dirt. If it is no longer possible to calibrate the sensor to the D1C you can try to clean the membrane. Cleaning the membrane You can remove small amounts of dirt by rinsing under a gently stream of tap water. In all other cases you must replace the membrane cap. IMPORTANT Never attempt to clean the membrane with acids/alkalis or mechanical aids (brushes or similar). If the sensor fails to calibrate after cleaning, you must replace the membrane cap. Replacing the membrane cap Firstly, unscrew the old membrane cap and rinse off as much of the electrolyte gel clinging to it as possible under running water. The rest of the gel can be removed with the aid of a soft paper handkerchief. Rub lightly over the sensor, particularly the reference system (brown ring). Then fill a new membrane cap with electrolyte gel and screw on (see 5 Assembly ). 10 Repairs The sensor may be repaired only at the factory. Please return in its original packaging. Prior to return, please carry out instructions as described in 11 Decommissioning. Page 14 ProMinent

Decommissioning / Disposal / Ordering Information 11 Decommissioning Decommissioning sensor: observe all safety guidelines as given in section 5 Assembly. Disconnect sensor from power supply (see 6 Installation ). Depressurise the in-line probe housing assembly. Loosen the tensioning screw. Slowly pull out the sensor from the in-line probe housing assembly. Unscrew the membrane cap over a wash basin or similar and empty. Rinse away the electrolyte gel with cold water (see 9 Servicing ). Rinse the electrodes with clean water and allow to dry. Screw on a fresh membrane cap loosely to protect the electrodes. Fit the membrane cap cover to protect the membrane cap. 12 Disposal Elektrolyte The electrolyte is non-toxic and can be disposed of with in-house waste. Sensor IMPORTANT Electronic waste is classified as special waste. Observe currently applicable local directives. In Germany used parts may be disposed of at communal town or district collection points. Used devices can alternatively be returned to ProMinent headquarters for a small charge. Please apply correct postage. 13 Ordering Information 1 bottle of electrolyte (100 ml) Part no. 1002712 1 membrane cap Part no. 1002710 Accessory set (2 membrane caps + 1 bottle of electrolyte) Part no. 1002744 Two-wire signal cable (2 x 0.25 mm 2, Ø 4 mm) Part no. 725122.6 CDP 1-mA-2 ppm (complete set) Part no. 1002149 The sensors themselves can be ordered only as complete sets: 1 sensor 1 bottle of electrolyte 2 replacement membrane caps 1 operating instructions manual ProMinent Page 15

Directives and Standards / Technical data 14 Complies with Directives and Standards EU directives: EG-EMV RL 89/336/EWG 91/263/EWG i.d.f. 92/31/EWG International standards: EN 50 081-1 EN 50 082-2 15 Technical data Measured variable Chlorine dioxide (ClO 2 ) Application range Process water containing surfactants, drinking water Measurement range 0.02-2 mg/l (at 40 C) ph range 5.5-10.5 Temperature range 10-45 C, 55 ºC for short periods Temperature compensated with external temperature sensor Pt 100 Temperature fluctuation speed Up to 10 ºC/min Storage temperature 5-50 C Resolution Corresponds to measurement range limits below Max. pressure 3 bar, 1 bar recommended (zero pressure at outlet, no pressure surges) Sample flow Recommended: 60 l/h Minimum: 40 l/h Maximum: 100 l/h Cross-sensitivity Ozone, chlorine Shelf life Membrane cap Typically 3-6 months depending upon the water quality Materials Membrane cap: Clear PVC Electrode shaft: Black PP and natural coloured PMMA Supply voltage 16-24 V DC Output signal 4-20 ma Enclosure rating IP 65 Page 16 ProMinent

ProMinent Page 17

Page 18 ProMinent

ProMinent Page 19

Addresses and Delivery Records from the manufacturer: ProMinent Dosiertechnik GmbH Im Schuhmachergewann 5-11 69123 Heidelberg Germany Telephone: +49 (6221) 842-0 Fax: +49 (6221) 842-419 info@prominent.com www.prominent.com ProMinent