A Fire Fighter s Nemesis

Similar documents
MATERIAL SAFETY DATA SHEET. PRODUCT IDENTIFIER Carbon Dioxide, Refrigerated Liquid

COMPOSITION / INFORMATION ON INGREDIENTS

Safety Data Sheet Steam Cylinder Oil C 460

1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND THE COMPANY/UNDERTAKING

OFF! CLIP-ON MOSQUITO REPELLENT

MATERIAL SAFETY DATA SHEET

Elgin Fire Department

Material Safety Data Sheet

According to the criteria of NOHSC, this material is classified as; Hazardous Substance, Dangerous Goods

MSDS (Material Safety Data Sheet)

MATERIAL SAFETY DATA SHEET Product Code: 10033

BBQ Master Hong Kong Limited

SAFETY DATA SHEET. according to 1907/2006/EC, Article 31 CYTOFIXX (CYTOLOGICAL FIXATIVE)

WINDEX ORIGINAL GLASS CLEANER

MATERIAL SAFETY DATA SHEET WWF of 5 1 Gal Xtreme Blue -20 Windshield Washer Fluid. 121 Landmark Drive Greensboro, NC 27409

: DuPont SUVA 410A Refrigerant

=.03% CO2 10/4/2012. Carbon Dioxide (CO2) Safety. Carbon Dioxide (CO2) Safety. Carbon Dioxide (CO2) Safety. Carbon Dioxide (CO2) Safety

Swallowed Do not induce vomiting give 250 ml water to drink. Seek immediate medical attention.

1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING. Types : ASHRAE Refrigerant number designation: R-507

*** SAFETY DATA SHEET ***

ECHM Recommendations for Safety in multiplace medical hyperbaric chambers

Example risk assessment for a motor vehicle mechanical repair workshop

FIRE,FIREFIGHTING & FIREFIGHTING EQUIPMENT

Quebec Quebec Tel : Fax : MSDS: P10 (10% Methane in Argon) PRODUCT INFORMATION

CAS-No. EC-No. Index-No. Concentration Benzyl carbazate

OCCUPATIONAL SAFETY AND HEALTH PROGRAM

SAFETY DATA SHEET BUTANE CARTRIDGE

: DuPont SUVA 407C Refrigerant

MRC Polymers Inc. Material Safety Data Sheet. Product Name: Naxaloy PC/ABS blends Product Series: 750, 760, 770, 770A3, 770A4, 770A5, 770A6, 770L, 772

MATERIAL SAFETY DATA SHEET - LINQSTAT Volume Conductive Film 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

Safety Data Sheet Customwood MDF

MATERIAL SAFETY DATA SHEET

15GAL STEEL OIL DRAIN WITH 110V PUMP

Contingency Plan. Content. 1. Preface. 2. Instructions

Escape Device Range. For a Safe Escape

DuPont ISCEON MO89 refrigerant

Safety Data Sheet. Product #: Aspira Scientific 521 Cottonwood Dr. Milpitas, CA

SAFETY DATA SHEET DALER ROWNEY 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING. Primer for Acrylic Paint

1. PRODUCT AND COMPANY IDENTIFICATION

SAFETY DATA SHEET DOUBLE TT MAINTENANCE SPRAY

WINDEX COMMERCIAL LINE GLASS CLEANER WITH AMMONIA- D

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 12 / 7 / 2012

Safety Data Sheet according to 1907/2006/EC, Article 31

Material Safety Data Sheet

Material Safety Data Sheet

Material Safety Data Sheet

Lesson 7: Respiratory and Skeletal Systems and Tuberculosis

RAID MAX CRAWLING INSECT BUG KILLER

MATERIAL SAFETY DATA SHEET CHAINDRITE EXTRA STRENGTH CRAWLING INSECT SPRAY

GESSO PRIMER WHITE DALER ROWNEY, 2 Corporate Drive, Cranbury, New Jersey, USA

Material Safety Data Sheet

Job Hazard/Safety Analysis For the Housekeeper

MATERIAL SAFETY DATA SHEETS

MATERIAL SAFETY DATA SHEET PRODUCT: SODIUM BISULFITE SOLUTION SECTION 1 - MANUFACTURER INFORMATION

Sodium Aluminum Tetrafluoride

Material Safety Data Sheet

PLEDGE MULTI-SURFACE CLEAN & DUST

Material Safety Data Sheet

: DuPont SUVA 134aUV Leakdetect

Safety signs and symbols

What is Dry Ice? Dry Ice Company Safety Rules: DRY ICE: SAFETY DATA SHEET & RISK ASSESSMENT

SAFETY DATA SHEET PRIVATE LABEL SULPHURIC ACID DRAIN CLEANER SPD1047/SPD1046

How To Ensure Safety On A Caravan Site

Propane Fuel. Material Safety Data Sheet

IN CASE OF EMERGENCY. Emergency Telephone Number 112

SAFETY DATA SHEET in accordance with 29 CFR and ANSI standard Z Exx - Carbon/Epoxy Laminat Material number 001Exx

TRICHLOROACETIC ACID SOLUTION Department of Pharmacy Duke University Medical Center Box 3089 Durham, NC

Date: 22 June 2005 Version: 2 Revision: Identification of the substance/preparation and company/undertaking

Ref IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING. : Disinfectant, Cleaning agent

Methane in Air % to 2.5%

MATERIAL SAFETY DATA SHEET (MSDS) ZINC DUST

GEORGIA INSTITUTE OF TECHNOLOGY ENVIRONMENTAL HEALTH AND SAFETY PERSONAL PROTECTIVE EQUIPMENT

Presented by: Rich Perry Marsh Risk Consulting

reflect look out! organisms: living things

SECTION 1 - PRODUCT IDENTIFICATION

Confined Spaces. The National Food and Drink Manufacturing Conference October 2012

DuPont "Teflon" Dry Multi-Use Lubricant

MATERIAL SAFETY DATA SHEET (in accordance with Directive 1907/2006 EC) Revised Date:

SIGMA-ALDRICH. Material Safety Data Sheet Version 4.0 Revision Date 02/27/2010 Print Date 08/25/2011

Material Safety Data Sheet

Material Safety Data Sheet

Compressed Gas Cylinder Safety

SCRUBBING BUBBLES VANISH CONTINUOUS CLEAN DROP- INS

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 12 / 7 / 2012

Material Safety Data Sheet Wix Diesel Fuel Additive

Revision Date 01/26/2012 Print Date 01/26/2012

M A T E R I A L S A F E T Y D A T A S H E E T

OFF! DEEP WOODS SPORTSMEN INSECT REPELLENT I (PUMP SPRAY)

MATERIAL SAFETY DATA SHEET. CAPTURE Carpet Dry Cleaner - Advanced Formula

Section 1 - Chemical Product and Company Identification

A Safe Workplace A Workplace Safety and Health Manual for Your Community Section: III-C Subject: G-9

ZOTEFOAMS plc. SDS-37 ZOTEK N Polyamide Foam Black

Material Safety Data Sheet

Metal welding safety. Guidance Note. Practical advice for employers on controlling hazards when welding. June Background. How to use the table

Material Safety Data Sheet

MATERIAL SAFETY DATA SHEET DATE: 2009, revised July 2011 PRODUCT NAME: BOSTON BRAKE & PARTS CLEANER PRODUCT CODE: 78200

Transcription:

A Fire Fighter s Nemesis Before the introduction of breathing protection, firefighters had little choice but to inhale smoke and toxic fumes when fighting fires. In some countries firefighters were known as smoke-eaters. With no face or lung protection, the heat and carbon released by burning materials would enter the lungs causing irritation, breathing difficulty and even burns to the lungs themselves.

Fighting a bushfire or entering a building meant smoke would quickly fill the lungs and irritate the eyes. The heat would begin to burn the skin and airway. A firefighter could be expelling mucous from his lungs and nose for days after such an incident. Some firefighters received permanent lung damage. It was so common for firefighters to be affected by smoke and fumes, that eyewash was carried on all fire appliances. Later oxygen cylinders were also carried to help firefighters suffering from smoke inhalation. Until the introduction of breathing apparatus (in the fire service referred to as BA) firefighters often wrapped wet cloth around their nose and mouth. This method was often used until the 1960 s as not all fire appliances carried BA in Western Australia.

Airing History BA in WA Developing a way to provide cool, clean air to firefighters was a major challenge to fire service authorities around the world. As cities grew fires became more frequent, intense and toxic. Endeavours to overcome this problem have created a history around three main ideas - pumping air, recycling air and compressing air. Breathing apparatus training 1938 Including the old smoke helmet and the New self-contained breathing apparatus This smoke shed was located at Perth fire station. A training area was also created at Fremantle Fire Station by converting the old stables into a smoke tunnel. This tunnel was used until Belmont training Centre was built in 1962. Pumping Air In the early 1800 s in Europe the first style of breathing apparatus (BA) was developed. It involved pushing or pumping air along a hose from a foot or hand pump (bellows) to a fullface helmet. While providing some clean air this system had limited use. The hose restricted movement of the firefighter and could be damaged by fire or sharp objects. Manually pumping air down a hose would only work for a short distance therefore the person working the bellows had to be close to the fire. Without protection themselves, the pump person would often have to abandon the apparatus leaving the firefighter without air. Keen to give this apparatus a try the WA Fire Brigades Board ordered two sets in 1910. They did not arrive at Perth Central Station until 1913. I am pleased to report the receipt of 2 smoke helmets from Messrs Siebe & Co, Germany. These were ordered over 2½ years ago and I had given up all hope of ever receiving same. Reported by Chief Officer Lapsely - WA Fire Brigades Board minutes 28 th March 1913 Although limited in delivering clean air, no alternatives were available. This device was used in the WA Fire Service for the next twenty-two years.

For volunteer fire fighters, especially in the country regions, access to breathing apparatus was still many years away. Recycling Air In 1935 a new method of providing clean air was introduced to the fire service. It involved an intricate process of mixing oxygen with recycled air. This device was carried by the firefighter and marked the end of pumping air down a hose and the beginning of a new era the self-contained breathing apparatus. Testing the new apparatus 1935 While providing the firefighter with independent movement and around two hours of clean air, these apparatus required meticulous cleaning and attention to airflow pressure and oxygen valve settings after each use. They were also heavy and uncomfortable and required a tight clip to be worn over the nose.

Station Officer John McMahon shown here wearing a Proto-set during breathing apparatus specialist training 1961. Calm relaxed breathing conserved oxygen and could therefore extend the time a proto-set could be worn. John achieved over 8 hours from one oxygen cylinder. Proto-sets in use c1969 There were several varieties of these apparatus used in Western Australia. All featured an oxygen cylinder, a breathing bag containing a substance to remove carbon dioxide, a cooling chamber and a series of valves and hoses.

Compressed Air In 1965 compressed air breathing apparatus was introduced to permanent fire stations in Western Australia. This method is still used today. Firefighters wear a full-face mask that allows them to draw air from the cylinder on their back via a hose and valves. The process of compressing air involves forcing a large amount of air into a small cylinder. This is done using pressure. The air is dry to breathe as all the moisture is removed during the process. Using a cylinder of compressed air and a full-face mask meant there was no need for nose pegs and air recycling components requiring cleaning and setting. Empty air cylinders were simply sent and refilled. Compared to the Proto-sets, the compressed air apparatus is lighter and more comfortable to wear.

Compressed air breathing apparatus in use c1971 Hazardous Materials As industry and the use of chemicals increased so did the potential for a firefighter to be exposed to toxic substances. The height of this risk occurred from the late 1930 s until protective suits and consistent use of breathing apparatus was introduced in the 1970 s. There are still many dangers facing firefighters but the exposure to smoke and toxic substances have been greatly reduced. More efficient breathing apparatus, splash suits and enclosed protective suits along with strict wash-down methods enable firefighters to tackle dangerous incidents with minimal risk of exposure. Portable chemical wash-down facility

Splash suit Fully encapsulated suit Splash Suite The protection of firefighters from hazardous and toxic atmospheres is a high priority that requires continuous research and introduction of new breathing apparatus, clothing and technology to keep up with emerging hazardous that may face firefighters today.

Types of Breathing Apparatus used in Western Australia There are two types of breathing apparatus: o Open circuit - air or oxygen once exhaled is passed out into the atmosphere o Closed circuit: an exhaled breath is contained within the apparatus and is recycled. OPEN CIRCUIT Type Apparatus Source Method. Siebe Anti-Poys open air Smoke helmet breathing hose to air Siebe Gorman Spirelmo open air Smoke helmet air hose from bellows Burrell open air Facemask through canister & air hose Puretha open air Facemask through canister & air hose Siebe Gorman Air Master Compressed Air Facemask cylinder to mask Draeger PA 54 & PA 80 Compressed Air Facemask cylinder to mask Spiromatic Compressed Air Facemask cylinder to mask CLOSED CIRCUIT Proto MARK 1V & MARK V Oxygen Face mask or mouthpiece cylinder Draeger BG 174 Oxygen Face mask cylinder to mask or mouthpiece Salvus Oxygen Face mask cylinder Some images to use with the panels in this exhibit area: Enlarge this one if you can

These firefighters entered a large fermentation tank at the Perth Swan Brewery in 1974 to rescue an injured and unconscious painting contractor. A build up of paint fumes within the container ignited causing a large explosion seriously injuring the worker. This rescue would not have been possible if breathing apparatus was not available. Standing - M Hickey and P Dance Front from Left - S.O C Lorimore, M Castlehow, A Hill, B Britton, Gas masks were introduced during the Second World War. There was no air supply these masks acted as a filter.

Caption - Imagine the smell and fumes