M. EL ASSAAD, J. TOPOUCHIAN, R. ASMAR

Similar documents
a Centre de Médecine Cardiovasculaire, Paris, France and b Lebanese Received 7 June 2009 Revised 6 September 2009 Accepted 17 September 2009

Vasc Health Risk Manag. 2011; 7: Published online 2011 November 30. doi: /VHRM.S27193 PMCID: PMC

The minimum numbers required for each blood pressure group.

An accurate automated blood pressure device for use in pregnancy and pre-eclampsia: the Microlife 3BTO-A

Original Article. Results

Inaccuracy of wrist-cuff oscillometric blood pressure devices: an arm position artefact? Adnan Mourad a, Alastair Gillies a and Shane Carney a,b

Measurement of Blood Pressure

American Journal of Pharmaceutical Education 2007; 71 (1) Article 01.

How to measure blood pressure using digital monitors

Name: OMRON M3 HEM-7200-E Upper Arm Blood Pressure Monitor

Device Equivalence Evaluation Form

OEM MAXNIBP Frequently Asked Questions

a Department of Clinical Medicine, Prevention and Applied Biotechnology, Received 20 August 2004 Accepted 24 September 2004

Variability of blood pressure No matter which measurement device is used, blood pressure will always be a variable haemodynamic

Clinical validations Overview OMRON blood pressure monitors June 2013

Device Equivalence Evaluation Form

Device Equivalence Evaluation Form

Manual Blood Pressure Measurement

April 3, Dear Autumn Liu,

Barry P McGrath, and on behalf of the National Blood Pressure Advisory Committee of the National Heart Foundation of Australia

Ambulatory blood pressure monitoring

Upper Arm Blood Pressure Monitor SC Instructions for use

Corporate Medical Policy Ambulatory Blood Pressure Monitoring

A Comparison of Forearm and Upper Arm Blood Pressure Measurements in a Sample of Healthy Young Adults

Blood Pressure. Blood Pressure (mm Hg) pressure exerted by blood against arterial walls. Blood Pressure. Blood Pressure

Blood pressure measurement devices. December 2013

INSTRUCTION MANUAL HEM-6052

Plank 1 Tool: Hypertension Medical Assistant Training (Providence Medical Group)

9/19/2013. Standardizing Preventive Care for Hypertension. About the Speaker. About the Speaker

Mercury is one of the world s most ubiquitous heavy metal neurotoxicants and is

Automatic Wrist Blood Pressure Monitor with

Hypertension Guideline V4

Blood Pressure Guidelines and Screening Techniques

EXPANDING THE EVIDENCE BASE IN OUTCOMES RESEARCH: USING LINKED ELECTRONIC MEDICAL RECORDS (EMR) AND CLAIMS DATA

Affordable ABPM and strictly guideline-based SBPM for accurate out-of-office blood pressure measurement.

FREEPHONE FREEFAX

NATIONAL HIGH BLOOD PRESSURE EDUCATION PROGRAM (NHBPEP)/NATIONAL HEART, LUNG, AND BLOOD INSTITUTE

Accurate home blood pressure measurements with the WatchBP home A. Instruction Manual

Journal of Hypertension 2005, 23: a Department of Computer Science, b Applied Computing Institute of the Faculty

Let s Do It Well. Nurse Learning Pack

ADVANCE: a factorial randomised trial of blood pressure lowering and intensive glucose control in 11,140 patients with type 2 diabetes

3 rd Russian-Bavarian Conference on Bio-Medical Engineering

dabl Educational Trust

Blood pressure in Germany

JNC-8 Blood Pressure and ACC/AHA Cholesterol Guideline Updates. January 30, 2014

Chronic Daily Headache and Blood Pressure Interrelated Prognosis

Digital Monitors. Blood Pressure. COMFORT M6 Comfort Blood Pressure Monitor Omron M6 Blood Pressure Monitor. Omron M2 Blood.

Epidemiology of Hypertension 陈 奕 希 李 禾 园 王 卓

Statistical Analysis Using SPSS for Windows Getting Started (Ver. 2014/11/6) The numbers of figures in the SPSS_screenshot.pptx are shown in red.

Accumulating evidence on the

Implementation of Cloud-Computing Healthcare based on Xenon Uploading System and Hilbert Huang Transform

High Blood Pressure in People with Diabetes:

AMBULATORY BLOOD PRESSURE MONITORING QUICK START GUIDE

Systolic Blood Pressure Intervention Trial (SPRINT) Principal Results

Disclosure of Relationships

Diagnosis, Evaluation, and Treatment of High Blood Pressure in Children and Adolescents

Full version is >>> HERE <<<

Work-site hypertension prevalence and control in three Central European Countries

2016 PQRS OPTIONS FOR INDIVIDUAL MEASURES: CLAIMS, REGISTRY

CHEM 1406 BSA/BMI Measurement Laboratory (revised 01/03//06) BSA, Body Surface Area

INVESTIGATING HEART RATE AND BLOOD PRESSURE

Absolute cardiovascular disease risk assessment

Vascular Risk Reduction: Addressing Vascular Risk

Portable, cordless, single-channel ECG Monitor HCG-801-E

Article paru dans l'ajh (American Journal of Hypertension) en anglais

ADULT HYPERTENSION PROTOCOL STANFORD COORDINATED CARE

From Concept to Rapid Visualization a Data Analytics Case Study

HEART HEALTH WEEK 3 SUPPLEMENT. A Beginner s Guide to Cardiovascular Disease HEART FAILURE. Relatively mild, symptoms with intense exercise

Comparing office-based and ambulatory blood pressure monitoring in clinical trials

CardioCard System. Product Specification and Sample Reports. PC-Based ECG CardioCard. PC-Based Stress. PC-Based Holter. CardioCard.

Measure #236 (NQF 0018): Controlling High Blood Pressure National Quality Strategy Domain: Effective Clinical Care

INSTRUCTION MANUAL. Ultra Premium Blood Pressure Monitor featuring ComFit TM Cuff. Model HEM-775

Training and Certification of Blood Pressure Observers GARY R. CUTTER, PH.D., AND C. MORTON HAWKINS, SC.D.

Measuring Your Blood Pressure at Home. A Review of the Research for Adults

AHA/ASH/PCNA Scientific Statement

Hypertension and Diabetes Status Bangladesh Demographic and Health Survey

INSTRUCTION MANUAL. IntelliSense Blood Pressure Monitor. ModelHEM-907XL. Thank you for purchasing the OMRON IntelliSense Blood Pressure Monitor.

WRIST BLOOD PRESSURE MONITOR

Bioinstrumentation. Kuo-Sheng Cheng, Ph.D. Department of Biomedical Engineering National Cheng Kung University

Blood Pressure Variability and Cognitive Decline. Day-to-Day Variability in Home Blood Pressure Is Associated With Cognitive Decline

Cuff less Continuous Non-Invasive Blood Pressure Measurement Using Pulse Transit Time Measurement

Blood Pressure Monitor Using Flexis QE128 Gabriel Sanchez RTAC Americas

Cardiorespiratory Fitness

Automated Ambulatory Blood Pressure Monitoring for the Diagnosis of Hypertension in Patients with Elevated Office Blood Pressure

Drug treatment of elevated blood pressure

Digital Blood Pressure Monitor. Model UA-767

Pressure Sensor Based Estimation of Pulse Transit Time

Carefully review the risks and potential, but unproven, benefits of treatment.

INSTRUCTION MANUAL. 7 series Blood Pressure Monitor with ComFit TM Cuff. Model BP760 ESPAÑOL ENGLISH

Evaluation of skills and knowledge on orthostatic blood pressure measurements in elderly patients

Guidelines for the management of hypertension in patients with diabetes mellitus

Exchange solutes and water with cells of the body

Imputation of missing data under missing not at random assumption & sensitivity analysis

MEDICAL POLICY SUBJECT: AUTOMATED AMBULATORY BLOOD PRESSURE MONITORING

ESC/EASD Pocket Guidelines Diabetes, pre-diabetes and cardiovascular disease

PEER REVIEW HISTORY ARTICLE DETAILS TITLE (PROVISIONAL)

Paul Harris, PhD. Planning, Collecting and Managing Data For Clinical And Translational Research

Hemodynamic Effects of 2% Lidocaine with 1:80000 Epinephrine in Inferior Alveolar Nerve Block

HYPERTENSION MANAGEMENT AND SURVEILLANCE AT PRIMARY CARE LEVEL: A SITUATIONAL ANALYSIS IN THE LIMPOPO PROVINCE

Transcription:

Validation of the OMRON HEM-637 IT blood pressure measuring device at the wrist level according to the International Protocol of the European Society of Hypertension M. EL ASSAAD, J. TOPOUCHIAN, R. ASMAR The CardioVascular Institute 21 Boulevard Delessert 75016 PARIS Phone: (33) 1 55 74 66 66 Fax : (33) 1 55 74 66 65 Email: icv@icv.org 1

The aim of the present study was to validate the OMRON HEM-637 IT device according to the International Protocol (1). This validation protocol was published by the European Society of Hypertension in 2002 and can be applicable to the majority of blood pressure (BP) measuring devices on the market. It is a simplified protocol that does not sacrifice the integrity of the earlier Association for the Advancement of Medical Instrumentation (AAMI) and British Hypertension Society (BHS) protocols. 1. Methods The OMRON HEM-637 IT was provided and randomly selected by the manufacturer. It is an automatic device for self-measurement of blood pressure at the wrist level using the oscillometric method. The validation team consisted of three persons: two observers trained in accurate BP measurement and a supervisor. The 2 observers have completed a training session according to the training program of the French Society of Hypertension. The agreement between the 2 observers was checked all over the evaluation period by the supervisor to make sure that the difference between the two is no more than 4 mmhg for systolic and diastolic BP values. Otherwise, the measurement should be repeated. Two standard mercury sphygmomanometers, the components of which have been carefully checked before the study, were used by the 2 observers as a reference standard. Measurements were taken to the nearest 2 mmhg simultaneously by the 2 observers. Measurements made by the mercury sphygmomanometer were made on the left arm supported at heart level. The circumference of the arm was measured to ensure that the bladder being used is adequate for the subject. At all nine sequential same-arm measurements using the test instrument and the standard mercury sphygmomanometer were recorded as follows: BPA BPB BP1 BP2 BP3 BP4 BP5 BP6 BP7 Entry BP, observers 1 and 2 each with the mercury standard Device detection BP, supervisor Supervisor with the test instrument Supervisor with the test instrument Supervisor with the test instrument Inclusions were ongoing until 15 subjects, fulfilling the criteria of the international guidelines, have been included. The device was then evaluated (first phase of the international protocol). 2

Then inclusion were carried out until 33 subjects at all, fulfilling the criteria of the international guidelines, have been included. The device was then evaluated (second phase of the international protocol). Recruitment of subjects was done in order to fulfill the recommended ranges of BP. There is three ranges for SBP and three for DBP: SBP DBP Low 90 129 40 79 Medium 130 160 80 100 High 161-180 101-130 For the primary phase, five of the 15 subjects should have a SBP in each of the ranges. Similarly, five of the 15 subjects should have a DBP in each of the ranges. For the secondary phase, 11 of the 33 subjects (including the first 15 subjects) should have SBP and DBP in each of the ranges. For each subject, the device measurements BP2, BP4 and BP6 were first compared to observer measurements BP1, BP3 and BP5 respectively and then to observer measurements BP3, BP5 and BP7 respectively. Comparisons more favourable to the device were used. BP1, BP3, BP5 and BP7 are the means of the 2 observer measurements. 2. Results : For all measurements, the difference between the 2 observers was -0.3 ± 1.4 mmhg for both systolic and diastolic BP. Thirty three subjects were selected according to the international protocol recommendations. No patient had atrial fibrillation or other sustained arrhythmia. Table 1: characteristics of the subjects: Number of subjects 33 Age (years) 53 ± 15 Arm circumference (cm) 30 ± 2 Gender (M/F) 19/14 Mean ± SD Arm circumference range for the 33 subjects was 26 32 cm so the standard cuff was used in all of them. Mean BP for the classification of the subjects (BPA) was 144 ± 24 mmhg and 88 ± 13 mmhg for the SBP and the DBP respectively. 3

Table 2: Number of comparisons falling within the 5, 10 and 15 mmhg error bands, Result of phase 1: Phase 1 5 mmhg 10 mmhg 15 mmhg Recommendation Required One of 25 35 40 Achieved SBP 35 40 45 Continue DBP 39 44 45 Continue Table 3: Number of comparisons falling within the 5, 10 and 15 mmhg error bands, mean difference (mmhg) and standard deviation (mmhg), Result of phase 2.1: Phase 2.1 5 mmhg 10 mmhg 15 mmhg Recomm. Mean diff. SD Required Two of 65 80 95 All of 60 75 90 Achieved SBP 75 90 98 Pass 0.2 5.6 DBP 88 98 99 Pass 0.2 3.6 Table 4: Number of comparisons per subject falling within 5 mmhg, Result of phase 2.2: Phase 2.2 2/3 5 mmhg 0/3 5 mmhg Recommendation Required 22 3 Achieved SBP 28 1 Pass DBP 31 1 Pass 3. Discussion The objective of the study was to assess the accuracy of the OMRON HEM-637 IT device according to the international validation protocol of the European Society of Hypertension (1). The International Protocol has been published by the Working Group on Blood Pressure Monitoring of the European Society of Hypertension aiming to simplify the 2 main available guidelines, BHS and AAMI, without loosing their merits. The main advantages of the International protocol is that it requires less subjects, 33 instead of 85, simplifying the procedure, without affecting the accuracy of the validation. Our experience has shown that recruiting subjects at the extremes of high and low BP, is difficult to obtain, mainly for high diastolic (DBP 101-130) and low systolic (SBP 90-129) groups. The International Protocol recommends for facilitating this issue, that recruitment should begin by targeting subjects likely to have pressures in the low-systolic and high-diastolic ranges, then progressing to complete the high systolic and low-diastolic ranges so that it will be easy to complete recruitment with the remaining medium ranges. 4

4. Conclusion The OMRON HEM-637 IT device fulfils the recommendations of the international validation protocol. (1) O Brien E, Pickering T, Asmar R, Myers M, Parati G, Staessen J, Mengden T, Imai Y, Waeber B, Palatini P. Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults. Blood Press Monit 2002; 7:3-17. 5

Plot of SBP difference between the test device and the mean of the 2 observers in 33 subjects (n=99) 30 25 20 Difference: device - observers (mmhg) 15 10 5 0-5 -10-15 -20-25 -30 80 90 100 110 120 130 140 150 160 170 180 190 Mean Pressure: device and observers (mmhg) 6

Plot of DBP difference between the test device and the mean of the 2 observers in 33 subjects (n=99) 30 25 20 Difference: device - observers (mmhg) 15 10 5 0-5 -10-15 -20-25 -30 30 40 50 60 70 80 90 100 110 120 130 140 Mean Pressure: device and observers (mmhg) 7