4good reasons 60% HEAT COST SAVING. Heat insulated facades with real clinker closers. Heat Insulation With Clinkers. Instructions

Similar documents
K2 STONE NATURAL VENEER

Mold Preventing I nterior System

OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide. GeneralShale.com

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

12.1 Schlüter -KERDI-BOARD

How to build a Pizza Oven in 4 days

FIXIT.CH. Aerogel Insulating Plaster System. Handling Guidelines. Easy to use. Mineral based W/mK BAUSTOFFE MIT SYSTEM

Technical Data Sheet Art. No Kiesol. applications. Shelf-life. rate depending on application. Characteristic data of the product

Clad Direct Glaze Window Installation Instructions

LAYING BLOCK AND BRICK

Natural Thin Stone Veneer

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP

How to Install Hardwood Flooring Over a Sub Floor

Window Installation Instructions

SEE HOW TO MAKE LIME PLASTER WHY USE LIME? PATTI STOUTER, BUILD SIMPLE INC. FEBRUARY 2013

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko

Timber Decks. Technical Note. March 2007

Basic Spring Motor Roller Shades

WATERPROOFING OF WET ROOMS

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

Active and Passive Sash Replacement

RELAZZO DECKING THE TERRACE. INSTALLATION GUIDE. Construction Automotive Industry. REHAU R20680 EN

Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems

Thin Veneer Stone Installation Guide

Baumit Renders for Porotherm Masonry. Application Guidelines. n Light and easy application n Tried and tested

Installation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

Installing Shutters using Fasteners

Lay blocks with mortar

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

VOLUME AND SURFACE AREAS OF SOLIDS

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

pinta ACOUSTIC PANEL [1/7]

Installation Instructions Avalanche XUV Cap IMPORTANT! IMPORTANT!

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE

Mineral waterproof coating PCI Dichtschlämme

Minor Cracks in Horizontal Surfaces

If stepping is required, step at 180mm as seen in this picture.

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

Diameter. Swift Lift Round Recess Plug. Note: The diameter of the narrow recess plug is the same as the diameter of the round recess plug.

Technical Advice Note

Seven. Easy Steps. Your Own Walkway, Without Mortar. or Concrete. to Installing. Driveway and Patio

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

Puddle Flange. FRANK Puddle Flange

How to Build Your Own CornHole Game

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+

Material test chamber with mechanical convection

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

Rooflight INSTALLATION INSTRUCTIONS

Solvent Cementing Instructions For Plastic Pipe & Fittings

RAUFOSS EXPLOSIVE COMPRESSION FITTINGS

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render

Incubator with mechanical convection

DIY CABINET REFACING INSTALLATION GUIDE

HS-Steel-Classic. Curing chambers for the concrete block industry in a proven steel version

Wecryl Waterproofing System under surfacing supplied by others

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Advisers for real building

Packaged Terminal Air Conditioner Wall Sleeve Installation

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

peel adhesion 2 breaking load 4 rolling ball 6 shear adhesion 7 carton test 9 summary test methods 11

METHOD A10 (a) THE DETERMINATION OF THE IN-PLACE DRY DENSITY OF SOIL OR GRAVEL BY THE SAND REPLACEMENT METHOD

ELECTRIC PERISTALTIC MORTAR POINTING PUMP

Laying the First Course. 1. Excavate the site and construct the footing.

Composite Stone Veneer

3 Masonry and Manufactured Stone (Interior and Exterior)

PRODUCTBLADEN GT ROCKPANEL STRUCTURE

Flocking of textiles. Flocked shirt 13. flocking drying cleaning. adhesive. application. creation

Cedar Cottage Doghouse Plans

8.7 Schluter -KERDI-LINE

Chapter 3 Installing Over-the-Post Railing on an L-Shaped Stair

INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS

Selection, Use, and Care of Brushes

International Greenhouse Company

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Sealing & Bonding Sika solutions for Window Installation

SPREFIX SPRAY INSULATION _ in the marine market.

Tips on Applying a Clear Finish

Brick Veneer Construction

OWNER S MANUAL FOR THE PATIO SAUNA

Vinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

Speed-Mat Rectangle Cutter

Installation Instructions For Slider Casement Air Conditioners

Technical handbook Panel Anchoring System

Types of Structures. Mass Structures. A Layered Look

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

Euro Oak Installation

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Removable Aluminium posts

INFRARED QUARTZ WALL HEATER

Gear PEPSI CAN STOVE INSTRUCTIONS

Resurfacing Concrete. Page 1 of 5

Andersen Electric Window Opener for Andersen Awning and Roof Windows

Editorial. Table of contents Neopor Styropor

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Transcription:

Heat Insulation With Clinkers. UP TO 60% HEAT COST SAVING 4good reasons for insulating a 4facade with clinkers heat cost saving exclusive appearance increase in value simple assembly Heat insulated facades with real clinker closers. Professional quality can be achieved so fast, easily and inexpensive!

Lowered Heating Costs Improved Quality of Life Heat insulated facades reduce high heating costs drastically and improve the quality of life within your own four walls by generating an exceptionally comfortable room climate. The Heat Insulating Clinker System is a particularly economic way of producing highly efficient heat insulating exterior walls. It is a durable protection for exterior walls under all weather conditions. Heat energy waste through exterior walls may be reduced up to 60 per cent. The following instruction shows how easily each step of work can be carried out, convince yourself. UP TO 60% HEAT COST SAVING Without Dämmklinker. With Dämmklinker. Quality of life 02

A Great Variety of Different Clinkers. A small selection of clinker closers available R 100 R 116 R 200 R 209 cream white nuances, smooth cream white nuances, yellow nuances, smooth yellow Paris, yet-black hand mould grained, sanded R 215 R 216 R 220 R 227 bronze-varicoloured, yellow nuances, terracotta, smooth terracotta, red-varicoloured hand mould grained, sanded hand mould grained, sanded variegated, Formback - structure R 228 R 287 R 307 R 335 terracotta, red-varicoloured yellow-varicoloured variegated, red-varicoloured variegated, antic-varicoloured variegated, variegated, yet-black Formback -structure, aubergine Formback -structure hand mould grained, sanded R 343 R 435 R 436 R 487 red-varicoloured variegated, red nuances, red-varicoloured variegated, red Manchester, flat grained hand mould grained, sanded hand mould grained, sanded Formback -structure 03 Colour shades

Modular Grid System for Clinker Facades. Insulating and Placing of Clinker in the Reconstruction Area System Structure 04 05 03 07 02 01 06 clinker closers type NF 01 DK jointing mortar 02 DK bonding mortar 03 modular grid insulation board 04 screw dowels U8/60 05 base frame sections 06 background 07 System structure 04

Preparation Tools Needed. For carrying out the work simply, quickly and properly, please obtain the following tools: > water level > hand drilling machine and a stone drill > cordless screw driver and a recess > hand saw > folding rule > stainless steel tooth trowel and mason s trowel > filling trowel > 20l bucket for mixing Components of the Heat Insulating Clinker System - The heat insulating system consists of seven single components which are exactly matched to each other. The components are: > base frame sections > DK bonding mortar > modular grid insulation boards WLS 033 > screw dowels U8/60 > clinker closers type NF (type DF on request) > angular clinker closers > DK jointing mortar 05 Processing in detail

Stages of Work. 01 Preparing the background The background has to be free of adhesion reducing materials such as loose old plaster, remains of paint, dust, dirt and oily substances. Strongly absorbing and sandy backgrounds should be prepared with Dämmklinker deep solvent primer LF or with Dämmklinker priming coat <One for All>. EINE FÜR ALLES Grundierung Tiefengrund LF 02 Setting up the base frame sections To ensure that the clinkers will be exactly lined up, the base frame sections have to be adjusted absolutely level. (Water level) For anchoring the base frame sections at the walls, place the first dowel in the outer long hole. The other dowels have to be set with a distance of 0.5 m between each other. (There are 6 dowels per base frame section.) In case of a severely uneven background, please use the washers provided in the Dämmklinker base frame section fixing kit for evening out the wall. Furthermore the fixing kit contains plug sockets which ensure the right distance between the sections and provide an expansion of the material without damages. 03 Preparing the grid insulation boards Before fixing the first row of grid insulation boards, the bottom of the boards has to be shortened with a hand saw or a hot wire (approx. 5 cm including the first land). Within the following rows, this work step is not necessary anymore. Please fix the grid insulation boards in a way, that there is no level difference between the boards and that the vertical joints are offset by at least 10 cm. 04 Cementing the grid insulation boards The bonding mortar has to be mixed according to the instructions on the back of the package. Then apply the mortar on the backside of the insulation board (as it is shown on the left picture). Position the prepared board on the base frame section and press it firmly against the wall. Important: Remember to cement the following boards level and evenly. Avoid any offset of the boards surfaces in order to enable a proper cementing of the clinker closers. 05 Dowelling of the grid insulation boards (6 screw dowels per m²) When the cement has dried (after 24 hours at +20 C at the earliest), fix the insulation boards with screw dowels (on average at the middle and edge areas, 6 screw dowels per m² depending on the building height). Drill holes (diameter 8 mm) through the insulation boards into the background. Then place dowels in the drill holes and fix the screw tightly by using a cordless screw driver. Tight the screws in a way, that they are level with the plate surface of the dowel. To avoid any bulging of the insulation boards in the area of corners, increase the number of dowels. Important: The anchoring depth in the bearing wall should be between 25 and 110 mm (depending on the type of stonework or wall material of the background). 06 Applying the contact layer on the grid insulation boards Apply DK bonding mortar with high pressure on the fitted insulation board. Then create a grooved bed by using a tooth trowel. Important: Apply only as much mortar as clinker closers can be placed until the mortar has dried (depends on air humidity and object temperature). work in detail 06

Stages of Work. Applying of bonding mortar on the clinker closer 07 Apply a thin layer of cement on the whole back of the clinker closer by using a mason s trowel. ( Buttering-Floating-method ) Bonding mortar, which gets onto the visible surface of the clinker closer during processing, has to be dabbed away immediately with a moist sponge do not rub! Otherwise the bonding mortar will soak in and cannot be removed completely! Placing of clinker closers 08 Now press the clinker closer firmly in the prepared grooved cement bed. The further tiring should always be done according to the wall bond. If cement comes out at the sides during tiring, please remove it immediately. This preserves the moulded depth of the joint. Placing of angular clinker closers 09 The cementing and placing of the angular clinker closers is conducted as described in stage 8. At quoins and window corners the clinker closers have to be shortened to a length of about 17 cm. (This is only necessary if the clinker closers are placed in an irregular wall bond.) Important: Always start placing of angular clinker closers from the corner area! Placing at window and door areas 10 The grid insulation boards have to be cemented and dowelled as described in stages 4 and 5. Important: In the head areas of windows, window sills and doors the lands have to be removed. Concerning the cementing of the angular clinker closers please observe an equal distance between the joints. Note: If the window reveal width is too narrow, this area can be insulated with thinner insulation boards (for example 30 or 40 mm). Not insulated window reveal areas can lead to a thermal bridge effect of up to 10 per cent (in relation to the total façade area). Head 11 The head has to be done in a wall bond of one clinker closer alternating with a half closer (as it is shown on the picture). The head height is given by the modular dimension. Filling of joints 12 The filling of joints can be started after the complete drying (48 h at the earliest, depending on the outside temperature). Mix the DK jointing mortar according to the instructions on the package. Recommendation: Mix the jointing mortar to a slightly moist and plastic consistence. Fill each joint by using a filling trowel. Make sure that the whole depth of the joint is filled. After the joint filling is set, small amounts of mortar can be reapplied if necessary. When the filling is completed, the façade should be brushed step by step diagonally to the joints with a clean hand brush. 07 work in detail

The Insulating Effect. Building material of the wall bulk density class [kg/dm³] thermal cond. coefficient [W/m²K] wall thickness [cm] U-value* of the wall [W/m²K] U-value with insulation board** 60мм 80мм 100мм normal concrete DIN 1045 2,4 2,1 24 3,52 - - 0,30 KS-R(P) concrete precision block DIN 106 2,2 1,3 15 3,50 - - 0,30 KS-R(P) concrete precision block DIN 106 2,0 1,1 15 3,26 - - 0,30 KS-R(P) concrete precision block DIN 106 2,0 0,99 15 3,11 - - 0,30 KS-R(P) concrete precision block DIN 106 2,0 1,1 17,5 3,04 - - 0,30 KS-R(P) concrete precision block DIN 106 1,8 0,99 17,5 2,88 - - 0,30 KS-R(P) concrete precision block DIN 106 2,0 1,1 20 2,84 - - 0,30 KS-R(P) concrete precision block DIN 106 1,8 0,99 20 2,69 - - 0,30 KS-R(P) concrete precision block DIN 106 2,0 1,1 24 2,58 - - 0,29 KS-R(P) concrete precision block DIN 106 1,8 0,99 24 2,42 - - 0,29 solid brick / vertically perforated brick 2,0 0,96 24 2,38 - - 0,29 KS-R(P) concrete precision block DIN 106 1,4 0,7 17,5 2,38 - - 0,29 solid block / brick (Vbl) LB, DIN 18152 1,8 0,87 24 2,24 - - 0,28 granulated slag brick DIN 398 2,0 0,76 24 2,06 - - 0,28 full block / full brick (V) LB DIN 18152 1,6 0,74 24 2,02 - - 0,28 KS-R(P) concrete precision block DIN 106 1,4 0,7 24 1,95 - - 0,28 solid brick (old houses) 2,0 1,05 38 1,88 - - 0,28 hollow block / ganged brick LB DIN 18151 1,0 0,64 24 1,83 - - 0,28 solid brick / vertically perforated brick 1,2 0,5 24 1,54 - - 0,27 granulated slag brick DIN 398 1,0 0,47 24 1,47 - - 0,27 LHIz, A+B, DIN 105/2 0,8 0,39 24 1,27 - - 0,26 solid block / brick (Vbl) LB, DIN 18152 0,8 0,39 24 1,27 - - 0,26 full block / full brick (V) LB DIN 18152 0,5 0,32 24 1,09-0,30 0,25 LHIz, A+B, DIN 105/2 0,7 0,3 24 1,03-0,29 0,25 hollow block / ganged brick LB DIN 18151 0,5 0,29 24 1,00-0,29 0,25 foam mortar DIN 4065 0,8 0,29 24 1,00-0,29 0,25 foam mortar DIN 4065 0,5 0,22 24 0,79-0,27 0,23 LHIz T after authorization 0,8 0,21 30 0,63 0,28 0,25 0,22 LHIz T18 after authorization 0,8 0,18 36,5 0,46 0,24 0,22 0,19 U-value of an old house < 0.30 [W/m²K] according to EnEV 2006 Rule-of-thumb: U-value x 10 = fuel oil in liters per m² heated area and heating period U-value x 10 x 3 =CO² emmission in kg per m² heated area and heating period * U-value: describes the amount of heat (in kwh) which is transmitted through a part of the building surface of 100m² when there is a temperature difference of 10 C between the interior and the exterior. The smaller the U-value, the smaller the heat energy loss - that means a good heat insulation. The placed clinker closers were not taken into account in this calculation. ** further insulation board sizes on demand Insulating effect 08

Calculation Assistance Model House (rectangular ground plan no bays, twisting areas, etc.) Step 1: Step 2: Calculation of the wall facade area including the front and rear sides Calculation of the frame section length subtraction of door width total frame section length (m) total: subtraction of the sum of all window and door areas (per each window and door: E x F): Step 3: Calculation of the corner length Amount of house corners Total facade wall area (m²): Addition of the total of all window and door lengths: (per each window and door: E+2xF) total corner length (m) Please use the values calculated above for the determination of the material demand on the next page. 09 calculation assistance

Material Demand Calculation. Model calculation - it s really easy! 1. Base frame section (length: 2.5m) > Calculation of the house s base frame length (see page 9) Example: base frame length = 40m > Consumption: 40m / 2.5m base frame = 16 base frame sections 2. Base frame mounting kit (1 box is sufficient for 25 running meters) > Calculation of demand according to the base frame length of the house > Consumption: 40m : 25m / mounting kit = 2 mounting kits 3. DK bonding mortar (consumption: approx. 8.0 kg/m2) mounting of insulation boards: approx. 5.0 kg/m2; placing of clinker closers: approx 3.0 kg/m2. Old houses and uneven surfaces require a higher amount of mortar. > Calculation of the total facade area Deduction of window and door reveals (see page 9) Example: 125 m2 (total) - 25 m2 = 100 m2 outdoor area > Consumption: 100m2 x 8.0 kg/m2 = 800 kg 800 kg : 25 kg/unit = 32 units DK bonding mortar 4. Grid insulation board The demand of insulation boards has to be calculated with about 3 5 per cent cutting loss > 5% cutting loss has to be added to wall facade area > Example: 100 m2 + 5 % = 105 m2 5. Screw dowels U8/60 (consumption 6 dowels per m2) The additional demand for corner areas is not included. > Wall facade area is to be multiplied with the consumption > Example: 100 m2 x 6 Pcs./m2 = 600 screw dowels 6. Clinker closers type NF (consumption: 48 closers per m2) > Wall facade is to be multiplied with the consumption > Example: 100m2 x 48 Pcs./m2 = 4800 clinker closers 7. Angular clinker closers (consumption: 12 closers per running meter) > The total length of all quoins, door and window corners has to be calculated. This result has to be multiplied with the consumption. Example: 12 m (quoins) + 30 m (Ex.: 5 Windows, one door = 42 m) > Consumption: 42 m x 12 Pcs./m = 504 angular clinker closers 8. DK joint mortar (consumption: approx. 6.0 kg/m2) > Outer wall area is to be multiplied with the consumption Example: 100 m2 x 6.0 kg/m2 = 600 kg > Consumption: 600 kg : 25 kg/unit = 24 units DK joint mortar 9. DK silicone resin preserver 5 l of concentrate (ratio 1:9) = 50l applicable emulsion Consumption on flat grained clinker closers approx. 0.2l per m2 Consumption on grained sanded clinker closers approx. 0.3l per m2 > The outer wall area has to be multiplied with the consumption. Example (flat grained clinker closers): 100 m2 x 0.2 l/m2 = 20 l > Consumption: 1 canister of concentrate Material demand calculation 10

Comparison Without Dämmklinker With Dämmklinker 11 comparison

Klinker-Zentrale www.daemmklinker.de info@daemmklinker.de KLINKER-ZENTRALE GmbH Im Hof 6 51580 Reichshof-Erdingen + 49 2297 9110-0 + 49 2297 7110