Technical Data Sheet

Similar documents
TECHNICAL DATA SHEET DURO HARD CHROME PLATING PROCESS

NO TARN 15. 5) Can be used on Silver AND Gold. Protects gold from blackening during shipping due to reaction with box chemicals.

Nickel Free Room Temperature Seal: an innovative and ecological process

An Ammonium-free, Acid. Zinc/Nickel (12-15% Ni) Process

AESF Aerospace / Airline Plating Forum - Tulsa, OK.

DURAPOSIT TM SMT 810 Electroless Nickel

Removing Heavy Metals from Wastewater

Metal Rescue Rust Remover Technical Data

QUALANOD SPECIFICATIONS UPDATE SHEET Nº 9 Edition page 1/5 COLD SEALING PROCESS

PRETREATMENT TECHNICAL DATA SHEET WATER EMULSIFIABLE RUST PREVENTATIVE PRODUCT DESCRIPTION

Corrosivity of Water Supplies

NIKAL BP RTU ELECTROLYTIC NICKEL SOLUTION For Advanced Packaging Applications

Ion Exchange Softening

Wastewater Reuse. Typical treated wastewater is:

Anodizing Reference Guide

Metal Ion + EDTA Metal EDTA Complex

Product Bulletin INTEROX HYDROGEN PEROXIDE

Syllabus OC18 Use litmus or a universal indicator to test a variety of solutions, and classify these as acidic, basic or neutral

ZINCROLYTE VS DUPLEX 700

RAPID FIXER FACT SHEET A LIQUID RAPID FIXER FOR BLACK AND WHITE FILMS AND PAPERS. August 2002

Water Softening for Hardness Removal. Hardness in Water. Methods of Removing Hardness 5/1/15. WTRG18 Water Softening and Hardness

Safety Data Sheet Avesta Neutralization Agent 502

Agricultural and Veterinary Chemicals Code (Listed Chemical Product Home Swimming Pool and Spa Products) Standard 2014

5.0 EXPERIMENT ON DETERMINATION OF TOTAL HARDNESS

MATERIAL SAFETY DATA SHEET

Silica Over-Saturation, Precipitation, Prevention and Remediation In Hot Water Systems Edited By Dave Peairs, Cal Water, Technical Director

Properties of Acids and Bases

Best Practice in Boiler Water Treatment

THE BLUE WASHING BOOK

RECOVERY and PURIFICATION of NICKEL SALTS and CHROMIC ACID using the RECOFLO SYSTEM

Using Magnesium Hydroxide

KODAK Developer System Cleaner and Neutralizer

RO / NF Cleaning Guidelines

MATERIAL SAFETY DATA SHEET Description: SAF DRAIN Revision Number: 00

Environmental Technology March/April 1998

Electroplating with Photoresist Masks

Material Safety Data Sheet

Metal Finishing: How to Save on Alkaline Cleaners, Acids, and Rinse Water May 10, 2011 Dave Fister, Senior Staff Engineer

Specifications for the QUALANOD Quality Label for Sulphuric Acid-Based Anodizing of Aluminium

Protecting Galvanized Steel Sheet Products from Storage Stain Rev 2.1 Aug-03

HEXAVALENT CHROMIUM REMOVAL FROM INDUSTRIAL WATSEWATER BY CHEMICAL PRECIPITATION METHOD

Ingredient CAS Number Weight % ACGIH TLV PEL STEL Phosphoric Acid mg/m3 1 mg/m3 3 mg/m3

Acids, Bases, and ph

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

PEROXIDE SAFETY DATA SHEET (60% H2O2) Safety Data Sheet

Zinc Electroplating CHOOSING THE BEST PROCESS FOR YOUR OPERATION

WATER CHEMISTRY AND POOL WATER BALANCE

Alkaline Manganese Dioxide Battery Product Safety, Transportation and Disposal

SurTec 650 Tri-Chrome Passivation of Aluminum

Water Treatment & Purification Chemicals

Material Safety Data Sheet

Fact Sheet: Disposal of Alkaline Batteries

To meet our acceptance criteria, we may require you to partially treat your wastewater before it discharges to sewer.

DYES AND DYEING 2003 by David A. Katz. All rights reserved. Permission for classroom use provided original copyright is included.

Technical Information DF30

Mechanical Systems Competency 1.20

The Chemistry of Carbohydrates

Any other time call the SFASU Police at Emergencies 911 Non-emergencies

UDOT SPILL PREVENTION and RESPONSE PLAN for CONSTRUCTION SITES

Food Protection Services

Sulfites for Oxygen Control

Introducing an All New Line of Cleaning Chemicals

The Owners Coated Coil, Cleaning and Maintenance Service Manual.

STANDARD PHOTOGRAPHIC PRINTING 08/ minutes to 3 minutes. HCA (hypoclearing agent): *rapid washing agent. 20 minutes at degrees

DuPont ISCEON MO89 refrigerant

ENVIRONMENTAL MANAGEMENT: CLEAN WATER RESEARCH AS RELATED TO ACID MINE DRAINAGE

Special coating Corrotect. Anti-corrosion protection for rolling bearings and precision components

b. Alkalinity make your life easier and get the alkalinity between 80 and 120 PPM. c. ph from 7.2 and 7.8 so that the other chemicals work properly

DEIONIZATION IN A "NUT SHELL"

Oxidizer(s) Management and Use Guidelines

ABC CIRCUITS 10 Circuit Drive Circuit Town, IN SLUG CONTROL PLAN

: DuPont SUVA 407C Refrigerant

GROUND WATER CONTAMINATION INFORMATION

The National Board of Boiler and Pressure Vessel Inspectors 1055 Crupper Avenue Columbus, Ohio

PRODUCT PROFILE. ELECTROLOY in partnership with FCT Asia Pte Limited. in manufacturing. Nihon Superior Lead Free Solder Bar.

INTAC PARTS & SERVICES ( H)

PART 1 - INTRODUCTION...

Ion Exchange Resins for Metal Plating and Surface Finishing

TAIYO PSR-4000 AUS703

Personnel Related FAQs

Emergency Showers and Eyewashes Mike Adkins Wednesday, October 31, 10:00-11:1511:15 a.m.

Rubber-to-Metal Bonding

Scotch-Weld TM. Epoxy Adhesive 1838 B/A Green 1838 B/A Tan 1838-L B/A Translucent. Technical Data February, Product Description

Household Acids and Bases

Basic Pool & Spa Care

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

Conductivity and TDS Meters

EXPERIMENT 4 Acid Strength

Warranty. 1/5. Warranty

GALVANIZING NOTES MECHANICAL AND CAUSTIC CLEANING PROCESS AND DESIGN NOTES ON HOT DIP GALVANIZING BY CHRISTINE KLEEN AND THOMAS LANGILL, PH.D.

1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING. Types : ASHRAE Refrigerant number designation: R-507

Wire Drawing Soap Lubrication: Principles And Factors Affecting Selection

Material Safety Data Sheet

Material Safety Data Sheet

Safety Data Sheet according to 1907/2006/EC, Article 31 Printing date: Revision:

PART I: PREPARATION OF SOLUTIONS AND STANDARDIZATION OF A BASE

Chemical Handling : Bulk Liquid Chemical Unloading. Northern Michigan Wastewater Operators Seminar September 23, 2008

Particularly Hazardous Substances (PHS) Standard Operating Procedure (SOP)

3M Ionic Liquid Antistat FC-4400

09990 MOLD REMEDIATION, LEAD-BASED PAINT ABATEMENT AND ENCASEMENT OF ASBESTOS

Transcription:

Technical Data Sheet LANTHANE BLUE 126 A High Performance, BLUE Passivate for Zinc G. Schiavon C. De Val E 16.09.10 MPK Translation Creation Approval Alpha. Index Date Observations 1 / 8

Table of Contents 1. Process and Deposit Description... 3 General description... 3 Product features... 3 2. Make-up and Maintenance of the Plating Bath... 3 Make-up... 3 Equipment... 4 Operating conditions... 4 Replenishment and maintenance... 5 3. Plating Sequence... 6 4. Waste Water Treatment... 7 5. H & S... 7 Safe handling... 7 Storage... 7 6. Warranty... 8 Disclaimer of Responsibility... 8 2 / 8

1. Process and Deposit Description General description LANTHANE BLUE 126 is a liquid trivalent passivate which provides high corrosion resistance and a pronounced BLUE film when applied to all zinc electrodeposits. Product features Formulated to provide a pronounced blue film and exceptional corrosion protection to all zinc electrodeposits. Bath concentration can be altered to achieve the desired corrosion protection without negatively affecting the color of the film. Completely hexavalent chromium and oxidizing agent free. Can be applied in rack and barrel applications. For increased corrosion protection and/or friction modification, can be used in conjunction with any of our complete line of FINIGARD topcoats. 2. Make-up and Maintenance of the Plating Bath Make-up Fill the tank to 2/3 of the final volume with water. Add the required amount of LANTHANE BLUE 126, Fill with water to the final operating level. Mix well. If necessary, adjust the ph to 2.0 units with 20% or 30% Sodium Hydroxide. Typical make-up requirements are as follows: Per 1.000 litres LANTHANE BLUE 126 Sodium Hydroxide Water 100 l (10% v/v) 1.5 Kg (3 lbs) To volume 3 / 8

Equipment LANTHANE BLUE 126 passivate is made of acid substances, so we advise to use resistant materials such as PVC, PPH, ebonized or plasticized steel. The use of a thermostat and air agitation equipment is recommended. Operating conditions Parameter Optimum Working range LANTHANE BLUE 126 100 ml/l (10% v/v) 40-100 ml/l (4-10% v/v) Ph 1.8 1.6-2.5 Temperature 22 C (72 F) 20-25 C (68-77 F) Dipping time 30 seconds 20-50 seconds Rack system agitation Light air Barrel system agitation Barrel rotation is sufficient Concentration Depending upon the available dwell time, we recommend operating at the lower concentration and higher time. A higher concentration cannot compensate for low temperature (ex. 15 C). Low temperature greatly reduces the film formation. For decorative applications not requiring superior corrosion protection, we recommend operating at 40 ml/l (4% v/v). Temperature When temperatures are below 20 C, the passivation process is slow and irregular, creating colourless, matte and sometimes spotty films. ph With new bath make-up, adjust the ph up to 2.0 units. Ideal operating ph ideal value must be evaluated and defined according to: Plant dwell and transfer times Zinc electrolyte used Availability of HNO 3 pre-dip PH corrections must be made with: 65% nitric acid (42 Bé) or 30% caustic soda. 4 / 8

Dipping time When transferring from LANTHANE BLUE 126 tank to first rinse, the passivate film is still active. When passivation is new, we recommend dwell times of 30-50 seconds. As the bath ages and zinc increases, we recommend reducing dwell times to maintain the aesthetic blue color. Agitating Air agitating must be moderate and uniform. Alternatively, mechanical agitation via pump/filter can also be used. Without agitation, it will be necessary to increase the dwell time to achieve the same performance and/or appearance. Replenishment and maintenance Automated ph control is recommended. Fluoride resistant probes are required. If not automated, we recommend frequent adjustments (minimum once every 4 hours). The optimal ph value is dependent upon the total treatment time and to temperature. Consumption per 100 m 2 (1076 ft 2 ) of treated surface: The figures above do not include drag-out. 0.30-0.40 l. of LANTHANE BLUE 126 (d= 1.27 g/cc ) 1 gallon / 10,500-14,000 ft 2 Drag-out incidence is basic to determine product consumption and industrial costs. With medium drag-out during operative phase: Rack system plants 0.2 l/m 2 Barrel system plants 0.25 l/m 2 Real total consumption per 100 m 2 of treated surface: 1.8-2.4 l. of LANTHANE BLUE 126 (d= 1.27 g/cc) 1 gallon / 1,700-2,500 ft 2 With higher drag-out, consumption will increase. Nitric acid consumption will depend on process sequence and on zinc electrolyte used. 5 / 8

LANTHANE BLUE 126 can be analyzed via titration or AA. Both methods can be provided by Coventya s Technical Service Department. The passivate film colour and shade can be influenced by all of the following: concentration, ph, dipping time, temperature, iron/zinc contamination levels and drying temperature. Immersion time will affect the film thickness and color as follows: Spotted transparent yellow blue - violet intense blue light blue transparent. With continued time/thickness the work processed will ultimately end up as iridescent blue/green. Metallic contamination limits: Zinc 10-15 g/l (10,000-15,000 ppm) Iron 100-150 mg/l (ppm) The presence of iron will cause a yellow spotty appearance, especially in the drying and dripping points on holes. 3. Plating Sequence Typical Processing Sequence 1. ZetaPlus, PRIMION or Alcyon Zinc (8-12µm) 2. Cold Water Rinse 3. Cold Water Rinse 4. Cold Water Rinse 5. Acid Activate (0.2 0.5% nitric acid)* 6. Cold Water Rinse 7. Cold Water Rinse 8. LANTHANE BLUE 126 9. Cold Water Rinse 10. Hot water rinse (60 C) Activate prior to passivate with nitric acid 42 Bé (0.2%) for cyanide and acid zinc; (0.5%) for alkaline non-cyanide zinc. Notes: Even if acid activation is not necessary for acid zinc, it will be fundamental for alkaline electrolytes. 6 / 8

The rinse between activation and passivation is important because it reduces zinc, iron and sodium salt drag-out that can reduce passivate bath life. Frequent changing of the activation solution guarantees a longer LANTHANE BLUE 126 bath life and better performance/appearance of the work being processed. Drying must be done properly for optimum results. Drying stabilizes the passivate film and ensures the highest level of performance and appearance. 4. Waste Water Treatment Operating solutions of LANTHANE BLUE 126 do NOT contain hexavalent chromium compounds. They will, however, contain heavy metals, namely trivalent chromium, zinc, and iron that may need to be treated based upon the combined overall wastewater flow and the existing treatment process. Coventya offers a complete line of OMEGA WaterCare wastewater treatment chemicals. Contact Coventya for details on how this technology can be used in a specific installation if your discharge limits require enhanced treatment methods. The solution contains fluorides that may be precipitated using the calcium hydrate in waters and solution neutralization 5. H & S Safe handling The preparation, maintenance, and disposal of LANTHANE BLUE 126 solutions require the handling of concentrated, acidic, fluoride containing trivalent chrome chemicals. Additionally, concentrated alkali and/or acid may be required for ph adjustment purposes. Avoid contact with the skin and eyes. Wear protective clothing and safety gear. In the event of any contact, flush affected area with a large volume of cold water and contact a physician, if necessary. Please review appropriate LANTHANE BLUE 126 MSDS. Storage We recommend checking the use-by date on the label and on the C of A. We recommend storing the products in closed packages, away from heat sources and protected from rain and light. For further information, please consult our MSDS. The presence of a small quantity of precipitate does not change the product quality and performance. If some is present, we advise agitating before using. 7 / 8

6. Warranty Disclaimer of responsibility The data set forth in this bulletin is believed by COVENTYA to be true, accurate, and complete, but is not guaranteed. Our sole warranty is as stated in our Standard Terms and Conditions of Sale. We cannot warrant that our customers will achieve the same results from any process, chemical or product described in this bulletin because we do not have control over the conditions of use; nor can we assume any responsibility for our customer's use of any of our products in a manner which infringes the patents of third parties. 8 / 8