Percoll PLUS/Percoll. GE Healthcare Life Sciences

Similar documents
RESOURCE Q, 1 ml and 6 ml RESOURCE S, 1 ml and 6 ml

For in vitro preparation of human mononuclear cells from peripheral blood, bone marrow, and umbilical cord blood. Not for in vitro diagnostic use.

How to Download a GE Healthcare License File

Ficoll-Paque PREMIUM Ficoll-Paque PREMIUM Ficoll-Paque PREMIUM 1.073

GE Healthcare. UNICORN 5.2 vs Software Change Description

GE Healthcare. UNICORN 6.x. SQL Server 2008 configuration for UNICORN installations

soft ware change description

Amersham High Molecular Weight Calibration Kit for native electrophoresis

HiTrap Heparin HP, 1 ml and 5 ml

Gain efficiency in your process development with ÄKTA avant

Summary of GE Healthcare's Quality Management System (QMS) Covering BioProcess chromatography media, equipment, software, and spare parts

Sterile ReadyToProcess Hollow Fiber Cartridges Instructions for Use

CU-950 Installation Guide

Process-scale purification of monoclonal antibodies polishing using Capto Q

Page finder. 1. Legal Handling Safety warnings and precautions Storage Expiry 4

UniFlux 10: hollow fiber conversion kit ( ) installation instruction

UNICORN. Hardening Guide

GE Healthcare Life Sciences. Validation Services. Compliance support through life cycle management

Instrument services for WAVE Bioreactor systems

ReadyKart Mobile Processing Station Instructions for Use

GAMP5 - a lifecycle management framework for customized bioprocess solutions

Ficoll-Paque PLUS. Ficoll-Paque. Intended Use For in vitro isolation of lymphocytes.

Blue Sepharose 6 Fast Flow

UNICORN control software

His GraviTrap. GE Healthcare. Operation

GE Healthcare s cell culture media, sera and process liquids

Tissue Culture 1 Cell/ Microplates 2 HTS- 3 Immunology/ HLA 4 Microbiology/ Bacteriology Purpose Beakers 5 Tubes/Multi-

UNICORN 7.0 software. Description. gelifesciences.com

How To Test For Cleaning Efficiency With A Predictor 96 Well Filter Plate

Smart Asset Management Services

INSTRUCTIONS Edition AC

Cord Blood Re-imagined The use of cord blood stem cells for clinical applications and medical innovations

illustra MicroSpin G-25 Columns

GE Healthcare Life Sciences. An environmental life cycle assessment comparison of single-use and conventional bioprocessing technology

Fast Trak Training & Education

QIAGEN Supplementary Protocol

UNICORN MS SQL Server Integration

Plant Genomic DNA Extraction using CTAB

illustra puretaq Ready-To-Go PCR Beads

MabSelect SuRe. GE Healthcare Life Sciences

Profiling inhibitor selectivity for PARP protein family members

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Physical Properties of a Pure Substance, Water

Experiment 1: Measurement and Density

Lab 4: Osmosis and Diffusion

Biacore S200. Main applications. GE Healthcare. Label-free interaction analysis

ISOLATION AND PROPERTIES OF SECRETORY GRANULES FROM RAT ISLETS OF LANGERHANS. II. Ultrastructure of the Beta Granule

His Mag Sepharose excel. Ni Sepharose excel. HisTrap excel. gelifesciences.com

DETERMINING THE DENSITY OF LIQUIDS & SOLIDS

HiTrap Chelating HP, 1 ml and 5 ml

Essential Maths for Medics and Vets Reference Materials Module 2. Amount and Concentration.

Color, True and Apparent

Color, True and Apparent

MTT Cell Proliferation Assay

lung cancer targeted photodynamic therapy and imaging

UltraClean Soil DNA Isolation Kit

INSTRUCTION Probemaker

50 g 650 L. *Average yields will vary depending upon a number of factors including type of phage, growth conditions used and developmental stage.

DeCyder Extended Data Analysis (EDA) Software

IN Cell Investigator high-content analysis software v1.3

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

B&W PAPER DEVELOPERS DEVELOPERS FOR THE DISH/TRAY PROCESSING OF BLACK AND WHITE PHOTOGRAPHIC PAPERS

Experiment #10: Liquids, Liquid Mixtures and Solutions

SEPARATION OF A MIXTURE OF SUBSTANCES LAB

TOTAL PROTEIN FIBRINOGEN

HiPer Ion Exchange Chromatography Teaching Kit

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

Buffer solutions. Division of Radiooncology, Deutsches Krebsforschungszentrum, Heidelberg, Germany

Chapter 14 Solutions

BIOL 305L Laboratory Two

ZETA POTENTIAL ANALYSIS OF NANOPARTICLES

OXIDATION-REDUCTION TITRATIONS-Permanganometry

Math Matters: Dissecting Hydrometer Calculations

Chemistry B11 Chapter 6 Solutions and Colloids

QuickZyme Soluble Collagen Assay

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

Featuring fast rotor exchanges with AUTO-LOCK

MEMBRANE FUNCTION CELLS AND OSMOSIS

PART I SIEVE ANALYSIS OF MATERIAL RETAINED ON THE 425 M (NO. 40) SIEVE

Sample Analysis Design Step 2 Calibration/Standard Preparation Choice of calibration method dependent upon several factors:

Marmara Üniversitesi Fen-Edebiyat Fakültesi Kimya Bölümü / Biyokimya Anabilim Dalı PURIFICATION AND CHARACTERIZATION OF PROTEINS

Ficoll PM70 Ficoll PM400

UltraClean PCR Clean-Up Kit

Advances in Biopharmaceutical and Vaccine Manufacturing Plants

DENSITY MEASURING SYSTEMS

Diafiltration: A Fast, Efficient Method for Desalting, or Buffer Exchange of Biological Samples

Thermo Scientific Sorvall T3 and G3 Centrifuge Series. Capacity, reliability and performance for routine applications

Removal of Sulfate from Waste Water by Activated Carbon. Mohammed Sadeq Salman Computer Centre/ University of Baghdad

TECHNICAL BULLETIN. HIS-Select Nickel Affinity Gel. Catalog Number P6611 Storage Temperature 2 8 C

6 Characterization of Casein and Bovine Serum Albumin

AG 501-X8 and Bio-Rex MSZ 501(D) Mixed Bed Resin Instruction Manual. Bio-Rad Laboratories, 2000 Alfred Nobel Dr., Hercules CA LIT205 Rev B

Red Blood Cell Membrane Permeability. Lab #2

UltraClean Forensic DNA Isolation Kit (Single Prep Format)

HighPure Maxi Plasmid Kit

Using k-factor to Compare Rotor Efficiency

POROS CaptureSelect affinity columns for highspeed quantification of IgG Fc fusion proteins

NCL Method ITA-6. Leukocyte Proliferation Assay

Administration and Technical Manual

Transcription:

GE Healthcare Life Sciences Instructions 28-9038-34 AF Cell Preparation Media Percoll PLUS/Percoll Percoll PLUS is composed of colloidal silica covalently coated with silane. Percoll is also composed of colloidal silica but coated with polyvinylpyrrolidone (PVP). Centrifugation of Percoll PLUS/Percoll results in spontaneous formation of a density gradient due to the heterogeneity of particle sizes in the medium. Percoll PLUS/Percoll can be used for formation of gradients either by the use of convenient gradient mixers or by high speed centrifugation. In the latter case, the sample can be pre-mixed with the medium and then separated on the gradient created in situ. In this way, gradient formation and sample separation can be achieved in a single operation. Intended use Percoll PLUS/Percoll are well-referenced media for density gradient centrifugation of cells, viruses, and subcellular particles. The products are intended for research use only, and shall not be used in any clinical procedures, or in vitro procedures for diagnostic purposes. Where your procedures require sterile products, do not use Percoll or Percoll PLUS. Safety For use and handling of the products in a safe way, please refer to the Safety Data Sheet.

Table of Contents 1 Physical properties... 3 2 Instructions for use... 5 3 Density determination of Percoll PLUS/Percoll gradients... 6 4 Removal of Percoll PLUS/Percoll after centrifugation... 8 5 Points for practical use... 9 6 Ordering information... 10 2 28-9038-34 AF

1 Physical properties Percoll PLUS/Percoll have the following combination of properties 1 : Low osmolality permitting precise adjustment to physiological conditions without significant interference from the medium. Compatibility with living cells and viruses, allowing separation and recovery of intact, fully active systems. Impermeable to biological membranes, resulting in no change of buoyant density of particles during centrifugation. Spontaneous formation of gradient during centrifugation, allowing mixing of large sample volumes in the centrifuge tubes. Low viscosity resulting in rapid formation of gradients and particle separation. Properties Composition Density (g/ml) Osmolality (mosm/kg H 2 O) Conductivity (ms/m) Viscosity (cp) ph Endotoxin (EU/ml) Percoll PLUS Silica sol with covalently linked silane 1.130 ± 0.005 max. 30 - max. 15 9.4 ± 0.5 < 2 Percoll Silica sol with nondialysable PVP coating 1.130 ± 0.005 max. 25 max. 100 max. 15 9.0 ± 0.5-1 Data on File. 28-9038-34 AF 3

Density g/ml 1.14 ρ ο =1.135 ρ o =1.130 ρ o =1.125 1.12 1.10 1.08 1.06 1.04 Dilution with 0.25 M Sucrose Dilution with 0.15 M NaCl ρ o =1.135 ρ o =1.130 ρ o =1.125 1.02 Percentage of osmolality adjusted Percoll PLUS/Percoll in final solution 10 20 30 40 50 60 70 80 90 100 Fig 1. Dilution of stock osmolality adjusted Percoll PLUS/Percoll (340 mosm/kg H 2 O) with saline or sucrose solution. ρ 0 is the density of Percoll PLUS/Percoll from the bottle. More details of Percoll PLUS/Percoll properties may be found in the handbook Cell Separation Media, Methodology and applications, which is available at www.gelifesciences.com/cellprep. 4 28-9038-34 AF

2 Instructions for use Preparation of gradient material Percoll PLUS/Percoll are best used in balanced salt solutions, physiological saline, or 0.25 M sucrose. Cells can be separated on gradients in balanced salt solutions. Subcellular particles, however, tend to aggregate in the presence of salts and it is recommended that the separation of such particles be carried out in Percoll PLUS/Percoll diluted with sucrose (0.25 M final concentration). The low osmolality of Percoll PLUS/Percoll permits this parameter to be controlled by the user without significant interference from the density medium itself. The addition of 9 parts (v/v) of Percoll PLUS/Percoll to 1 part (v/v) of either 1.5 M NaCl, 10x concentrated cell culture medium, or 2.5 M sucrose will result in a solution adjusted to about 340 mosm/kg H 2 O. Solutions of different osmotic pressure can be produced by adjusting the relative volumes of Percoll PLUS/Percoll and salt or sucrose solution 2. The final adjustment to the required osmolality can be carried out by the addition of salts or distilled water. When precise osmotic pressures are required, it is recommended that the osmolality of the solutions be measured in an osmometer. Concentrations other than 10x physiological saline may also be used satisfactorily 3. 2 Vincent, R., Nadeau, D. Anal. Biochem, 141 (1984) 322 328 3 Timonen, T., Reynolds, C.W., Ortaldo, J.R., et al. J. Immunol. Methods 51 (1982) 269 277 28-9038-34 AF 5

Centrifugation with Percoll PLUS/Percoll Percoll PLUS/Percoll will form self-generated gradients by centrifugation at approximately 10,000 g av (in 0.15 M saline) or 25,000 g av (in 0.25 M sucrose) in fixed-angle rotor heads after 15 minutes. Cells or subcellular particles can be mixed with Percoll PLUS/Percoll prior to centrifugation and will band isopycnically, as the gradient is formed in situ. Although Percoll PLUS/Percoll are best used in angle-head rotors, banding of cells on pre-formed (continuous or discontinuous) gradients may be carried out at 400 g av for 20 to 30 minutes in swing-out rotors. More details of centrifugation conditions and buoyant densities of cells, viruses, and subcellular particles centrifuged on Percoll PLUS/Percoll gradients may be found in the handbook Cell Separation Media, Methodology and applications, which is available at www.gelifesciences.com/cellprep. All experiments described with Percoll can be performed with Percoll PLUS. 3 Density determination of Percoll PLUS/Percoll gradients Measurement of the density of Percoll PLUS/Percoll solutions after gradient fractionation can be carried out easily using a refractometer. Refractive index has a linear correlation with the density of a Percoll PLUS/Percoll solution. See the table and Figure 2 for information of density and refractive index for dilution series of Percoll in solutions of sucrose and NaCl at 20 C. 6 28-9038-34 AF

Percoll in sucrose Density (g/ml) Refractive index 1.0345 1.3457 1.0484 1.3478 1.0618 1.3499 1.0765 1.3518 1.0903 1.3541 1.1040 1.3561 1.1180 1.3582 1.1319 1.3600 1.1461 1.3626 1.1547 1.3638 Percoll in NaCl Density (g/ml) Refractive index 1.0085 1.3350 1.0243 1.3372 1.0403 1.3399 1.0558 1.3423 1.0713 1.3449 1.0869 1.3470 1.1029 1.3493 1.1189 1.3519 1.1305 1.3534 1.1513 1.3569 Density (g/ml) 1.18 1.16 1.14 1.12 1.10 1.08 1.06 1.04 1.02 1.00 Percoll in NaCl Percoll in sucrose 0.98 1.330 1.335 1.340 1.345 1.350 1.355 1.360 1.365 Refractive index Fig 2. The correlation between refractive index and density at 20 C for Percoll in solutions of NaCl and sucrose. The straight lines were obtained by leastsquares linear regression. The goodness of the fit (R2) was 0.9995 both for Percoll in NaCl and in sucrose. 28-9038-34 AF 7

Figure 2 was obtained by measuring density and refractive index on Percoll in solutions of NaCl and sucrose prepared in the following way. In a measuring cylinder, 1.5 M NaCl or 2.5 M sucrose was added to 1/10 of the final desired volume. To this, the required volume of high density Percoll, as calculated by Equation 1, was added. V 0 V ρ 0.1ρ 10 = ------------------------------------- 0.9 [1] ρ 0 1 V 0 V ρ ρ 0 ρ 10 = = = = = volume of high density Percoll [ml] volume of the final solution [ml] desired density of the final solution [g/ml] density of Percoll [g/ml] density of 1.5 M NaCl or 2.5 M sucrose [g/ml] It should be noted that the Equation 1 does not take into consideration the volume occupied by solid silica in Percoll PLUS/Percoll. Therefore, the final concentrations of NaCl and sucrose in the solutions will be slightly higher than 0.15 M and 0.25 M respectively. The densities were measured using a density meter (Mettler Toledo, DE-40) and the refractive indexes were measured using an Abbe refractometer (Carl Zeiss). 4 Removal of Percoll PLUS/Percoll after centrifugation To remove the gradient medium from the biological material, perform one of the procedures outlined below. Cells can be recovered free from particles of Percoll PLUS/Percoll by dilution with physiological saline and centrifugation to collect the cells. Subcellular particles can be separated from Percoll PLUS/Percoll by the procedure described above. The size of the particles will determine the centrifugal force required to separate the particles from Percoll PLUS/Percoll. Gel filtration or ion exchange chromatography can also be used to separate biological material from Percoll PLUS/Percoll. 8 28-9038-34 AF

5 Points for practical use Storage Percoll PLUS/Percoll may be stored unopened for up to 5 years at room temperature. When opened, it should be stored at 2 C to 8 C. Care and cleaning of equipment Solutions containing silica usually give a pellet at the bottom of the centrifuge tube and deposits of silica on the walls of tubing used for fractionation. These deposits may be difficult to remove when dry and it is recommended that all equipment is washed thoroughly immediately after use. Spillage of Percoll PLUS/Percoll can be removed by washing with water. Aggregates of silica particles It is an inherent tendency of all silica colloids to form aggregates on prolonged storage. These aggregates may be observed in some batches of Percoll, either as a slight sediment at the bottom of the tube or as a faint white band with a density of 1.04 to 1.05 g/ml. This band may form during gradient formation in the centrifuge or during low speed centrifugation of a preformed gradient. The aggregated silica does not interfere with the separation of biological particles and almost all cells and organelles have buoyant densities of greater than 1.05 g/ml in Percoll. For the majority of cell, virus, and organelle separations, any silica aggregates banded from the gradient material (see above) may be ignored. For specific experiments, it may be desirable to remove aggregates; this may be achieved by filtration of Percoll through a depth filter prior to centrifugation. Aggregation is not a problem in Percoll PLUS due to the silane coating. 28-9038-34 AF 9

6 Ordering information Product Percoll PLUS Percoll PLUS Percoll Percoll Percoll Quantity 250 ml 1 l 250 ml 1 l 6 x 1 l Code No 17-5445-02 17-5445-01 17-0891-02 17-0891-01 17-0891-09 Related products Ficoll-Paque PLUS Ficoll-Paque PL Ficoll-Paque PREMIUM Ficoll-Paque PREMIUM Ficoll-Paque PREMIUM 1.084 Ficoll-Paque PREMIUM 1.073 Quantity 6x100 ml 6x500 ml 6x100 ml 6x500 ml 6x100 ml 6x100 ml Code No 17-1440-02 17-1440-03 17-5442-02 17-5442-03 17-5446-02 17-5446-52 Related literature Cell Separation Media, Methodology and applications Isolation of mononuclear cells, Methodology and applications Code No 18-1115-69 18-1152-69 10 28-9038-34 AF

For local office contact information, visit www.gelifesciences.com/contact GE Healthcare Bio-Sciences AB Björkgatan 30 751 84 Uppsala Sweden www.gelifesciences.com/cellprep GE, imagination at work and GE monogram are trademarks of General Electric Company. Ficoll-Paque and Percoll are trademarks of GE Healthcare companies. Percoll PLUS: Percoll PLUS is protected by the following patents and equivalent patents and patent applications in other countries, which are licensed to GE Healthcare from Dendreon Corporation: US patent number 5,789,148, US patent number 6,015,843 and European patent number 1,047,635. A free, non-transferable license to use this product for density gradient separation purposes under the above mentioned patent rights accompanies the purchase of the product from a GE Healthcare company and its licensed distributors, but any use of Percoll PLUS or any other organosilanized colloidal silica particle-based separation media to enrich, purge or isolate cells for active immunotherapy for oncology applications shall be excluded from such license. 2009-2013 General Electric Company All rights reserved. First published Mar. 2009 All goods and services are sold subject to the terms and conditions of sale of the company within GE Healthcare which supplies them. A copy of these terms and conditions is available on request. Contact your local GE Healthcare representative for the most current information. GE Healthcare Europe GmbH Munzinger Strasse 5, D-79111 Freiburg, Germany GE Healthcare UK Limited Amersham Place, Little Chalfont, Buckinghamshire, HP7 9NA, UK GE Healthcare Bio-Sciences Corp. 800 Centennial Avenue, P.O. Box 1327, Piscataway, NJ 08855-1327, USA GE Healthcare Japan Corporation Sanken Bldg. 3-25-1, Hyakunincho Shinjuku-ku, Tokyo 169-0073, Japan imagination at work 28-9038-34 AF 03/2013