Exterior Timber Decks. Please note: The life span of coatings on decks is very limited and will require regular maintenance of the coating

Similar documents
Wattyl Solagard. Wattyl Solver. Wattyl Weathergard

Application of Exterior Wood Finishes

SCHWARTZ WATER-BASE WOOD FLOOR SEALER AND WATER-BASE PREMIIUM WOOD FLOOR FINISH

Tractor Painting Tips

SC2000 CEMENT BONDING PROCEDURES

White rust on galvanized and galvanized pre-painted steel. Technical Information

Epoxy Floor Coating Problem Solving Guide

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

A Guide to Wood Floor Care

TECHNICAL DATA SHEET HAMMERITE METAL PAINT. Smooth Hammered Satin Aerosol

PRODUCT DATA SHEET Sika Cable System

RESTORE 10X Advanced Resurfacer FAQs Page 1 of 11

Division 9. SignaFlor Pad and Pour Flooring System

INDUSTRIAL FLOORING INSTALLATION CHALLENGES. James C. Ziegler, ArmorSeal Product Manager Sherwin Williams Cincinnati, Ohio, USA

Hardwood Maintenance. WORKBOOK and TIPS of the TRADE

Acrylic Enamel Topcoat

RAPTOR TRUCK BED LINER - BLACK

G4 is browny translucent in colour and is effected by UV light. Therefore it is for internal use unless top coated to protect it from UV light

Contents. Introduction...3. Determine the Type of Floor Finishing Project...4. Things to Think About Before You Start...5. Assemble Materials...

Stone Developments. Caring for Irish Blue Limestone Products. Irish Blue Limestone Maintenance Guide

BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION

WATER AND WOOD DON T MIX KEEPING YOUR TRIÂNGULO HARDWOOD FLOOR BEAUTIFUL SCRATCHES, INDENTATIONS AND GOUGES

3.8 HSP (High Solids Polyurethane)

Product Information/Specifications

MARTIN TESTING LABORATORIES (MTL) PAINTS AND COATINGS TESTING CAPABILITIES

"YOUR OLD HOUSE" - Paint By Ken Marchtaler, Certified Coatings Consultant

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 30 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Armstrong Do-It-Yourself Tile Installation System

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

Tried, Tested and Proven Timber Protection

Timber Decks. Technical Note. March 2007

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method F (100 C) calculated VOC-US/Hong Kong. US EPA method 24 (tested)

BLACK JACK ALL WEATHER ROOF COATING

Preface GENERAL TIPS WOOD FIBREGLASS STEEL ALUMINIUM PRODUCTOMSCHRIJVING

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

Flocking of textiles. Flocked shirt 13. flocking drying cleaning. adhesive. application. creation

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013

Eclipse. Technical Data Sheet. Polyurethane topcoat. Product Group

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

SCREEN PRINTING INSTRUCTIONS

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 28 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

RECOATING AND RENEWING SPF ROOFING SYSTEMS

THERMOTEK SELF ADHESIVE MEMBRANE +G2 OVER WOOD SYSTEM DESCRIPTION SELF ADHESIVE OVER WOOD (8YR) BS-SA/CS

THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER

PHOENIX Product Data Sheet (Updated on 14-Jan-2012)

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

Wecryl Waterproofing System under surfacing supplied by others

CLEANING GUIDE.

( II ) INDUSTRIAL & PROTECTIVE SYSTEM

A. Work on this project shall consist of, but is not limited to, the following:

Care and Maintenance for Wood Flooring

Scotch-Weld TM. DP410 Off-White. Product Data Sheet. Product Description. Key Features Rapid cure at room temperature; cure rate may be accelerated

SIGMAFAST 210. PRODUCT DATA SHEET December 12, 2014 (Revision of April 1, 2013) DESCRIPTION

Tips on Applying a Clear Finish

T R A N S F E R A B L E F U L LY

Elastic, 1-part-polyurethane, liquid waterproofing membrane

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 27 C calculated IED (2010/75/EU) (calculated)

How to Clean and Care for Reclaimed Wood Furniture

Paint and Stain Suggestions For Acorn Homes and Deck Houses continued...

Recommended Procedures for Use of YSI Water Quality Monitoring Instruments during Oil Spills

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

Solvent Cementing Instructions For Plastic Pipe & Fittings

SECTION POLISHED CONCRETE FINISHING

10 Ways to Prolong the Life of your Carpet

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 34 C IED (2010/75/EU) (calculated)

The Application Guide offers product details and recommended practices for the use of the product.

STERI-SOFT HIGH FOOT TRAFFIC, ULTRAVIOLET RESISTANT, URETHANE RESILIENT FLOORING SYSTEM, 1/8 GREEN BUILDING FEATURES TYPICAL APPLICATIONS

family of products is really Reichhold s answer to the growing need to meet more stringent regulations and performance requirements.

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

professional wooden floor treatment knowledge. experience. quality CREATING EXCEPTIONAL SPACES

RockSolid Deck Restoration Application

SunGuard IS 20 Technical Information

PERGOLAS AND CARPORTS

PRODUCT DATA SHEET DESCRIPTION:

The Owners Coated Coil, Cleaning and Maintenance Service Manual.

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

09990 MOLD REMEDIATION, LEAD-BASED PAINT ABATEMENT AND ENCASEMENT OF ASBESTOS

INDUSTRY RECOMMENDATIONS for Sanding, Sealing Court Lining, Finishing & Resurfacing of Maple Gym Floors

Barewood Octagon and Elongated Windows Installation Instructions

Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS

FLOOR MAINTENANCE GUIDE EXPECTATIONS AVOIDING PROBLEMS

1995 HI 28. There are two general types of clear wood finishes. They are the penetrating finishes and the surface finishes.

GUIDE SPECIFICATION COMBINATION SURFACE SYSTEM FOR NEW HOT MIX ASPHALT TENNIS COURTS I. PART 1 - GENERAL

GRIP-GARD BC BASECOAT CHROME

SEE HOW TO MAKE LIME PLASTER WHY USE LIME? PATTI STOUTER, BUILD SIMPLE INC. FEBRUARY 2013

Wood Floor Maintenance

METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES

Amtico and Spacia Commercial Maintenance Guidelines

Weathering. Western Red Cedar performs satisfactorily as a decking and siding product if it is left unfinished to weather naturally.

Despite spending many thousands of pounds on a beautiful new conservatory, it is a sad fact that many suffer from intolerable heat and glare problems

GUIDELINES FOR HANDLING FABRICATION INSTALLATION AND CLEANING

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

Tested to BS 6375: Part 1: 1989 and achieved a weathertightness classification of 2000 Pa (Special)

CHROME FX PUMP SYSTEM APPLICATION GUIDE

Winterizing Your Trailer and Storage Ideas

How to Choose a Hardwood Floor Finish One That s Perfect For Your Home

Care and Operation of Your New Windows

Additional Information. Paint Application

Transcription:

1/5 pages Systems 3 coats Cetol HLSe or 1 coat Cetol HLSe and 2 Coats Cetol Deck or 1 coat Cetol HLSe and 2 Coats Cetol Deck plus Please select required system. Key Practical coverage in m²/ltr per coat, depending on density of timber. Thinning % Drying time/recoatable after hrs Film thickness Application temperature C Brush clean up Products Sikkens Cetol HLSe Transparent, satin woodcare product for interior and exterior use. Its woodstain like qualities ensure timber grain remains highly visible. Cetol HLSe is 10-18m² dressed timber, 5-8m² band sawn timber, 5-7m² smooth plywood, 3-5m² band sawn plywood. Do not thin (thinning reduces the product's UV protection) 16 hrs at 20 C / 65% relative humidity Wet: 50 microns Dry: 10 microns Application temperature 5-35 C, Max Rel Humidity 85% Mineral turpentine See Product Data Sheet for full details. Sikkens Cetol Deck/Deck plus microporous allowing the timber to breathe. Available in a range of transparent colours. Use: Suitable for most types of timber. Used as a primer/basecoat for Cetol Filter 7 plus and as a stand alone 3 coat system on cladding, garden furniture, BBQ tables, handrails etc. Also commonly used as an interior timber stain under Cetol TSI Mat Plus Application: Stir well. Do not thin. Apply at 50 microns wet to clean, dry, sound substrate. Brush application recommended. Translucent satin topcoat for use on timber decks. Based on a special oil-alkyd resin combination and selected UV-absorbing pigments. Highly transparent; 7.5-10m² per coat. Do not thin (thinning reduces the product's UV protection) 16 hrs at 20 C / 65% relative humidity ensures optimum visibility of the wood grain, enhancing the appearance of the wood. Withstands physical wear. Microporous; allows the wood to breathe. Weather resistant. Water repellent. Very Wet: 60 microns Dry: 20 microns easy application. Use as a topcoat over Cetol HLSe to enhance the natural beauty of wood while Application temperature 5-35 C Mineral turpentine providing excellent protection against physical wear. Application: Stir well. Do not thin. Apply at 60 microns wet to clean, dry, sound substrate. Brush application recommended. See Product Data Sheet for full details. Sikkens Oplosser High solvent degreaser. Oplosser is used for the strip wiping of surfaces to be coated and to assist with the removal of natural resins, contaminants and residue.

2/5 pages See Product Data Sheet for full details on all products. Directions Preparation of hardwood decks: Allow to weather for AT LEAST 12 WEEKS, preferably longer, especially for oily resinous timbers such as Kwila (Merbau), Tallowood, Blackbutt. For slow drying timbers such as Spotted Gum, Yellow Balau, Batu, Ironbark etc we recommend a minimum weathering period of 6 (six) months. During the weathering period regularly hose down with water. This will assist extractives to leach out of the timber fibres as well as ensuring that moisture content adjusts to the surrounding climate - ie stabilizes. Please note that the kiln drying does not always retard tannin bleed. Before deck is laid it is advisable to heavily coat the end grain of boards: this will minimize moisture entry into the wood fibres. Coating MUST be deferred until the entire leaching / bleeding / drying process has ceased! If the timber is greasy, weathered or shows signs of discolouration, restore the weathered timber prior to coating using Jac Jay Timber Revitaliser and Jac Jay Oxalic Acid. See section on Timber Restoration. Allow the deck to dry completely. Prior to coating, belt sand / abrade (ie raise the grain), using 60-80 grit sandpaper. This will provide the best surface for coating penetration and adhesion. Preparation of softwood decks: LOSP treated timber must not be coated until the chemicals used in the treatment process have evaporated from the timber. Fillet stack all LOSP treated timber for approximately 4 12 weeks. Duration will vary depending on timber dimensions, longer may be required. Tanalised treated timber must be considered to be wet and therefore be fillet stacked for approximately 4 12 weeks. Duration will vary depending on timber dimensions. Longer may be required. Restore weathered timber prior to coating using Jac Jay Timber Revitaliser. See section on Timber Restoration. Before deck is laid it is advisable to heavily coat the end grain of boards: this will minimize moisture entry into the wood fibres. Once the deck has been fixed, leave for approximately 1 to 2 week(s) to allow timber to adjust to surrounding atmosphere. Prior to coating, belt sand / abrade (ie raise the grain), using 60-80 grit sandpaper. This will provide the best surface for coating penetration and adhesion.

3/5 pages

4/5 pages Directions (continued) Coating (for both hardwoods and softwoods):- Wipe down with Sikkens Oplosser or a sharp solvent to degrease. Ensure all timber to be coated has a moisture content of 16% or lower. Ensure surface of timber is dry, free of grease, dirt, mould, oil and salt (coastal areas). Ensure the timber surface to be coated is cool to the touch. Do not apply in direct sun. Thoroughly stir product with flat-ended stirrer for 5 minutes before each use, ensuring that the bottom of the tin is well scraped. Stir at regular intervals during use. Apply, using a good quality long hair natural bristle brush, along full length of boards 2-3 boards wide. Do not use lambswool applicator pads / paint rollers. Allow at least 24 hours between coats - some hardwoods need longer - until there is no sign of tackiness. Avoid walking on decks / moving furniture etc for at least 7 days to allow full curing s. Do not fillet stack to dry coatings. The first coat of Cetol HLSe should be overcoated within 14 days. Only if necessary, cut back lightly with fine grade paper between coats. Any reduction in film thickness will result in a reduction of the durability of the system. Do not mask uncoated timber as this may cause mould and other problems. Do not mask coatings until full cure has taken place, approximately 7-14 days depending on drying conditions. Follow all the masking tape manufacturer s requirements. Ensure masking tape is removed as soon as possible and inside the manufacturer s specified time limit. Do not apply to surfaces previously treated with linseed oil, polyurethane, waxes or stains. See section on Exterior Timber Restoration for full details. Keep coating away from rain, dew, condensation and all moisture until dry. Drying will be aided by good air circulation. Dispose of all materials safely. Do not dispose of any material down stormwater systems. Contact your local council for correct disposal methods. When undertaking any work always follow good trade, health and safety practices. Follow all good coating practices.

5/5 pages Life span 12 18 months. Please note that this relatively short life span is due to the severe wear conditions that walkon horizontal surfaces, i.e. decks, are subject to. - The Ultimate Challenge for Timber Coatings Horizontal surfaces are completely exposed to the sun s ultraviolet rays. These areas also receive high levels of moisture which can sit on the surface for days or even weeks. that are too low to the ground, have poor drainage or are not well ventilated beneath, do not allow moisture to escape from below the deck. This means that the timber is constantly subjected to moisture. are subject to physical damage from foot traffic (human and animal) and scraping from garden furniture. Physical damage to the coating accelerates deterioration caused by the elements to the timber beneath the coating s surface. Since the horizontal surfaces of a deck are subjected to the ultraviolet rays, standing water and excessive moisture, all coatings can expect some degree of peeling because the elements can literally push the coating off the timber surface. Maintenance Maintenance required will vary from normal to severe annually. To preserve the finish of your deck, as well as to give optimum weathering resistance, regular maintenance of the system is required. Maintenance depends on the location of the deck, its construction and many other variables (aspect, drainage, coating standard, usage etc). Inspect the entire deck annually for signs of peeling, discolouration or excessive wear. Every 12 months or earlier as the finish shows signs of wear; apply a fresh coat or two of the last product used. Prior to coating, thoroughly clean and wash the deck with detergent and water then rinse. Lightly sand using 180 grit paper. Ensure that the surfaces are thoroughly dry prior to recoating. Please Note Every care is taken to ensure that the information provided in this data sheet is accurate. Jac Jay Limited is unable to guarantee results as it has no control over the conditions under which products are applied, the substrate or the application. The customer has to determine the suitability of the delivered products or information for its intended purpose.