SystempaK (Digital/Single Case) Single-Input Arithmetic Relay Module Model J-SCP 90/95

Similar documents
Adjustment functions for both span and shift have been incorporated

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

J TB/TW Temperature limiter, temperature monitor

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Model: DC-A2IO Advanced HVAC Controller

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite:

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Modular I/O System Analog and Digital Interface Modules

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

Digital display DA 48

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Duct Humidity Transmitter

Telefon (+45) Telefax (+45) Installation and operating manual

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

NXL Series Inverters. HVAC Inverters made simple

Control Devices Catalogue. Control Devices. Preferred and Standard Products

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

T0118 T2118 T3118. Instruction Manual

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Contents. Document information

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Harmonic Drive acutator P r e c i s i o n G e a r i n g & M o t i o n C o n t r o l

SDI Multi Sensor Module with Charger Enclosure Station Support

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

THE INPUT/OUTPUT SYSTEM. Key Points

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

DC DC CONVERTER 1000W VDC Input / 12VDC Output

Smart DeviceNet Remote I/O Terminals

DCS Input/Output Relay Card Series

Electronic Control Devices The European Product Catalogue 2007

HERZ-Thermal Actuators

80 Series - Modular timers 16 A. Features

Safety technique. Emergency stop module BO 5988 safemaster

EXTERNAL DIMENSIONS AND PARTS

Radiant Temperature Sensor TY7321

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Vario-Series Accessories

USER MANUAL V5.0 ST100

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

RM4TG20 three-phase network control relay RM4-T - range V

40.3. Control Relays and Timers

ADM1TE 5/30A DIN rail single phase two wire energy meter

DMX2PWM 9 Channel Dimmer Setup Manual

Measuring Temperature withthermistors a Tutorial David Potter

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

Energy Management Energy Meter Type EM23 DIN

38 Series - Relay interface modules A

Proportional pressure regulators VPPE

PIEZOMETER AIRFLOW MEASURING RING

EFC Frequency converters

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Current and Temperature Ratings

User Manual for CH-PFC76810

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

PNOZsigma - Base units

Differential Charge Amplifier

ABB Drives. User s Manual HTL Encoder Interface FEN-31

TPM Product Type 107-D162-NNT 48-channel digital input and 16-channel digital output module with pluggable terminal

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Digital inductive conductivity transmitter

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

SPEED CONTROL SYSTEM

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Automation Unit TM 1703 ACP Flexible automation and telecontrol

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

Multi-Range Programmable DC Power Supplies 9115 Series

TX OPEN RS232/485 module

Impedance 50 (75 connectors via adapters)

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

3-phase, bidirectional energy meter

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

LM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs

MAXIMUM LOAD CURRENT 1 A SN SERIES

Transcription:

No.SS2-2330-0850 (Rev. 1) SystempaK (Digital/Single Case) Single-Input Arithmetic Relay Module Model J-SCP 90/95 Introduction The Single-Input Arithmetic Relay Module (J-SCP90/95) is a signal conversion module housed in a single case and is an advanced arithmetic module that can combine multiple arithmetic operation functions and execute them. After A/D conversion, the Single Input Arithmetic Relay Module performs input processing, such as filtering and low cut processing to a single point of input (4 to 20 ma/1 to 5V DC). A signal completed with input processing is then processed with arithmetic operations via the arithmetic equations assigned to a maximum of four processing combo boxes. After output low cut processing, the final output is D/A-converted to 4 to 20 ma/ 1 to 5V DC. By selecting one from 18 kinds of arithmetic equations provided as standard equations, an arithmetic function can be easily set on each processing combo box. A variety of arithmetic functions and input/output processing parameter settings can be implemented using the dedicated Loader Software, which operates on a general-purpose PC. The Single Input Arithmetic Relay Module provides the oneoutput model of J-SCM90 and the two-output model of J-SCM95. In the two-output model, isolation is employed between the two output circuits. Specification Input signal: 1 to 5V DC or 4 to 20 ma DC Input impedance: 1 MΩ (voltage input), 50 Ω (current) Output signal: No. 1 output; 1 to 5V DC or 4 to 20 ma DC No. 2 output; 1 to 5V DC Edge connector output; 1 to 5V DC (No. 1 output must be 1 to 5V DC when connecting the signal with the A-MC I/O cable.) Output impedance: Voltage output; 250 Ω or less, Current output; 250 kω or more Output range: -20 to +120%FS Allowable load resistance: 0 to 600 Ω (Current output: Up to +110%) Input/output response: Minimum of 160 msec, 0 to 90% response (Moving average and first-order lag filtering are not provided.) Output hardware filtering: 50 msec, 0 to 90% response Accuracy: 0.15%FS (Excluding arithmetic errors) Output update period: 5 msec (Output hardware filtering, 0 to 90% response, 50 msec) Insulation resistance: 500V DC, 100 MΩmin (Mutual between input - output - GND - power terminal) Withstand voltage: 1000V AC, 1 minute (Mutual between input - output - GND - power terminal) +10 Power supply: 24V DC -15 % Current consumption: 130 ma or less (at 24V DC) Ambient temperature: Normal operating condition; 5 to 45 Operation limit; 0 to 50 Ambient humidity: 0 to 90%RH (No condensation allowed) Mounting: Panel, wall, DIN rail attachment Front mask color: Black Weight: 400 g Operating influence: +10 Supply voltage effect; ±0.1%FS/24V DC -15 % Temperature effect; ±0.15%FS/10 Loader settings: Module ID; 16 one-byte characters, 8 two-byte kanji characters Input scaling setting; Zero span setting within input range (Setting of an input such as 0, 100% at each input) Input filtering; Unavailable/available (Moving average) Input low-level cut; Setting of input low-level cut value by %. Output low-level cut; Setting of output low-level cut value by %. Output zero span adjustment; Settable to any value within the output range (-20 to +120%FS) Startup delay; Setting of delay time before starting arithmetic actions during power-on startup (0 to 99 seconds) Function setting; Setting of arithmetic functions on processing combo boxes 1

Block diagram of arithmetic unit processing Input data (A/D value) Input scaling Input filtering (Moving average) Input % data Input low-level cut Arithmetic operation / conversion processing (Execute one of 17 types.) Linearization arithmetic operation / conversion processing (With, without) Arithmetic operation / conversion processing (Execute one of 17 types.) Arithmetic operation / conversion processing (Execute one of 17 types.) Output % data Output scaling Low-level cut Startup delay processing Output data (To D/A conversion) The blocks enclosed in boxes are the setting items. are the processing combo box numbers. 2

Description of signal conversion/arithmetic operations Conversion / operator Function outline Processing combo box used Settings No processing No signal conversion / arithmetic operation, -- Free-spec linearizer Sets the output % data for each input % (maximum of 101 points). Or, for the following application cases, tables can be easily created by selecting types and then setting equations and coefficients using the dedicated Loader: Orifice, venturi: ( Input signal) Partial flume: (Input signal) a Triangular notch weir: (Input signal) 5/2 Rectangular notch weir, Broad-Crested weir: (Input signal) 3/2 120.00% range Ratio / bias setting Arithmetic equation: Select one from the following. Output = Ratio Input + Bias Output = Ratio (Input + Bias) Ratio: -10.000 to 10.000 Bias: -999.99 to 999.99 First-order lag filtering Provides a first-order lag response. 0 to 999.9 seconds (63% response) Output ramping Provides a response with certain amount of changes. Setting of response time 0 to 100% of output range Gradient response time: 0.5 to 40.0 sec UP direction, DOWN direction. Time is set individually. Square root Input square root extraction With, without Input/output low-level cut point: 0.00 to 100.00 Reverse function Reverses an input % value for output. With, without Maximum value hold When the hold terminal is shorted: Holds and outputs a maximum input % value. When open: Outputs an input value without holding it. With, without Minimum value hold When the hold terminal is shorted: Holds and outputs a minimum input % value. When open: Outputs an input value without holding it. With, without Peak-peak hold When the hold terminal is shorted: Outputs the range between maximum and minimum. When open: Outputs an input value without holding it. With, without Low monitor One-point low monitoring switch Results can be used as DO to the next processing combo box. (No outputs to terminals) Monitoring setpoint: -999.99 to 999.99% Differential: 0.00 to 999.99% High monitor One-point high monitoring switch Results can be used as DO to the next processing combo box. (No outputs to terminals) Monitoring setpoint:-999.99 to 999.99% Differential: 0.00 to 999.99% Deviation monitor Switch for monitoring deviations from setting values Results can be used as DO to the next processing combo box. (No outputs to terminals) Monitoring setpoint: -999.99 to 999.99% Differential: 0.00 to 999.99% Rate-of-change monitor Scaling High/low limitter Rate-of-change limitter Preset value Preset with ramping Switch for monitoring the one-point rate of change Results can be used as DO to the next processing combo box. (No outputs to terminals) Converts an input value scale. Limits the high/low of an input value. Limits the rate of change of an input value. When the DI input (DO from previous arithmetic operation) is ON: Outputs a specified preset value. When OFF: Outputs an input value without any presetting. When the DI input (DO from previous arithmetic operation) is ON: Outputs a specified preset value. (Change function at certain gradients available) When OFF: Outputs an input value without any presetting., Rate of change Hi: 0.0 to 999.9%/second Rate of change Lo: 0.0 to 999.9%/second Scale low: -999.99 to 999.99 No indication of unit Scale high: -999.99 to 999.99 No indication of unit Low limit setpoint: -999.99 to 999.99% High limit setpoint: -999.99 to 999.99% Rate of change Up: 0.00 to 999.99%/second Rate of change Down: 0.00 to 999.99%/second Pre-set value (-999.99 to 999.99%) Pre-set value (-999.99 to 999.99%) Gradient (0.01 to 999.99%/second) 3

PC loader Communication connector Input signal + - 5V Analog input processing circuit Digital processing section Isolation circuit Isolation circuit No. 1 output circuit No. 2 output circuit + - + - External switch Hold input circuit Power circuit Figure 1. Functional configuration diagram of single input arithmetic unit Model Number Table One-output model Basic Model Number J-SCP90 X C Selections Additions Description I II I Arithmetic Relay Module (One-output model) No varnish coated Varnish coated -1 Input: 1 to 5V DC -2 Input: 4 to 20 ma DC 1 Output: 1 to 5V DC 2 Output: 4 to 20 ma DC -0 Without test report -1 With test report Two-output model Basic Model Number J-SCP95 X C Selections Additions Description I II I Arithmetic Relay Module (Two-output model) No varnish coated Varnish coated -1 Input: 1 to 5V DC -2 Input: 4 to 20 ma DC 1 No. 1 output: 1 to 5V DC, No. 2 output: 1 to 5V DC 2 No. 1 output: 4 to 20 ma DC, No. 2 output: 1 to 5V DC -0 Without test report -1 With test report Example: J-SCP90X-11-0 4

1 4 4 HOLD Notes: 1) Operate the Module with a cover. 2) Terminal screws: M3.5 3) Use the pressured terminals with insulation sheath. 4) For arithmetic operations set with HOLD functions, establish a short between terminal Nos. 1 and 2. 5) For two-output model. 5 5 Figure 2. Dimensions and wiring diagram 5

(standard accessory) Figure 4. Mounting method 6

MEMO 7

When ordering, please specify: 1) Tag number The ratio / bias function (Ratio: 1, Bias: 0%) is configured as an arithmetic function by default at the time of delivery. Input filtering is set to "Moving average available" by default. 2nd edition: Jan. 2013 8