PoLARUS 2 Locking Humeral Rod Surgical Technique

Similar documents
How To Use A Phoenix Retrograde Femoral Nail

Zimmer Periarticular Proximal Tibial Locking Plate

Zimmer Small Fragment Universal Locking System. Surgical Technique

How To Fix A Radial Head Plate

OptiLock Periarticular Plating System For Proximal Tibial Fractures. Pre-Launch Surgical Technique

Zimmer Natural Nail System. Cephalomedullary Nail Surgical Technique STANDARD

Zimmer Periarticular Elbow Locking Plate System

Technique Guide. Screw Removal Set. Instruments for removing Synthes screws.

Knotilus TM. Anchor Instability Repair. Technique Guide

Arthroscopic Shoulder Instability Repair Using the SUTUREFIX ULTRA Suture Anchor and SUTUREFIX ULTRA Instrumentation System

SALVATION. Fusion Bolts and Beams SURGICAL TECHNIQUE

NCB Distal Femur System. Surgical Technique

Expert LFN. Lateral Femoral Nail.

DRAFT. Triathlon TS Knee System. Surgical Protocol. Version 1

M/DN Femoral Interlocking & Recon Nail Intramedullary Fixation Surgical Technique

Technique Guide. Titanium Trochanteric Fixation Nail System. For intramedullary fixation of proximal femur fractures.

Achilles Tendon Repair, Operative Technique

Technique Guide. Orthopaedic Cable System. Cerclage solutions for general surgery.

Technique Guide. 2.7 mm/3.5 mm Variable Angle LCP Ankle Trauma System. Part of the Synthes variable angle locking compression plate (VA-LCP) system.

Technique Guide. DHS/DCS Dynamic Hip and Condylar Screw System. Designed to provide stable internal fixation.

Comprehensive Reverse Shoulder System

TRIGEN TAN and FAN Intramedullary Nails

V-TEK IVP System 2.7 System 4.0

Aesculap Veterinary Orthopaedics. Targon VET Interlocking Nail

Shoulder Restoration System

NCB Proximal Humerus System. Surgical Technique

Anatomic Percutaneous Ankle Reconstruction of Lateral Ligaments (A Percutaneous Anti ROLL)

TRIGEN INTERTAN Intertrochanteric Antegrade Nail Surgical Technique. Table of Contents

Technique Guide. VersiTomic. Michael A. Rauh, MD. Anterior Cruciate Ligament Reconstruction

Bigliani/Flatow The Complete Shoulder Solution TSA

TFN Titanium Trochanteric Fixation Nail System. For intramedullary fixation of proximal femur fractures.

TransFx External Fixation System Large and Intermediate Surgical Technique

Expert TN. Tibial Nail.

PERIPROSTHETIC IMPLANTS

Surgical technique. End Cap for TEN. For axial stabilization and simultaneous protection of soft tissue.

Zimmer MOST Options System

This article appeared in a journal published by Elsevier. The attached copy is furnished to the author for internal non-commercial research and

Technique Guide. Large Fragment LCP Instrument and Implant Set. Part of the Synthes locking compression plate (LCP) system.

Expert ALFN. Adolescent Lateral Femoral Nail.

Posterior Referencing. Surgical Technique

NCB Periprosthetic Femur Plate System. Surgical Technique

the revo / mini-revo shoulder fixation system s u r g i c a l t e c h n i q u e

Bankart Repair using the Smith & Nephew BIORAPTOR 2.9 Suture Anchor

Restoration Modular. Revision Hip System Surgical Protocol

ACL Reconstruction with Bone-Tendon-Bone Transplants Using the ENDOBUTTON CL BTB Fixation System

Restoration Modular Cone Body/Conical Distal Stem Femoral Components Using the Restoration Modular Instrument System Surgical Technique

The information contained in this document is intended for healthcare professionals only.

Malleolar fractures Anna Ekman, Lena Brauer

Technique Guide. Reamer/Irrigator/Aspirator (RIA). For intramedullary reaming and bone harvesting.

ZIMMER BIGLIANI/ FLATOW THE COMPLETE SHOULDER SOLUTION. Total Shoulder Arthroplasty Surgical Technique

Technique Guide. 3.5 mm and 4.5 mm Curved Locking Compression Plates (LCP). For minimally invasive osteosynthesis.

LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

TwinFix Cannulated Compression Screw

Technique Guide. 4.5 mm LCP Proximal Femur Plates. Part of the Synthes Periarticular LCP Plating System.

Anteromedial ACL Reconstruction Surgical Technique for Soft Tissue Grafts

Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery.

Versa-Fx II Femoral Fixation System Surgical Techniques

TABLE OF CONTENTS. Surgical Technique 2. Indications 4. Product Information Patient Positioning and Approach 2

TABLE OF CONTENTS. Indications and Contraindications 3. Features and Benefits 4. Ease of connection 4 Stable fixation concept 5

Titanium Wire with Barb and Needle. For canthal tendon procedures.

INTRODUCTION Cerclage Cable Vs. Monofilament Wire

ORTHODONTIC MINI IMPLANTS Clinical procedure for positioning. Orthodontics and Implantology

Zimmer FuZion Instruments. Surgical Technique (Beta Version)

Total Shoulder System. Anatomic adaptability... simplified SURGICAL TECHNIQUE

Surgical Technique + Design Rationale

Double Bone Plug Meniscus Reconstruction Surgical Technique

Anterior Lumbar Interbody Fusion (ALIF). Instrument set supports placement of ALIF spacers using anterior or anterolateral approach.

Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

The information contained in this document is intended for healthcare professionals only.

Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology. Surgical Technique

How To Perform An Elbow Operation

Mini TightRope CMC Surgical Technique

Foot and Ankle Technique Guide Proximal Inter-Phalangeal (PIP) Fusion

MINI FRAGMENT SYSTEM. Instruments and implants for 1.5 mm, 2.0 mm, and 2.4 mm plate fixation PRODUCT OVERVIEW

THE SHOULDER JOINT T H E G L E N O H U M E R A L ( G H ) J O I N T

The Material Difference. Options for Rotator Cuff Repair, Labral Repair and Suture Management

Expert HAN. Expert Hindfoot Arthrodesis Nail.

CLAW II. Polyaxial Compression Plating System SURGIC A L T ECHNIQUE

ACTIV ANKLE DISTAL AND DIAPHYSEAL FIBULA INNOVATION MEANS MOTION

Integra. Subtalar MBA and bioblock Implant SURGICAL TECHNIQUE

BONE PRESERVATION STEM

Adult Forearm Fractures

Open Rotator Cuff Repair Rehabilitation Program Methodist Sports Medicine Center, Indianapolis, IN Department of Physical Therapy

Stabilization of Acute Acromioclavicular Joint Dislocations using Dog Bone Button Technology Surgical Technique

Rotator Cuff Tears in Football

Zimmer M/L Taper Hip Prosthesis. Surgical Technique

AstroSystems Digital Setting Circles for Zhumell, GSO, Apertura and Astro-Tech

VariAx Distal Radius Locking Plate System. Anatomical & Universal Volar Plates Dorsal Plates Fragment Specific Plates

ANTERIOR CERVICAL DISCECTOMY AND FUSION. Basic Anatomical Landmarks: Anterior Cervical Spine

Zimmer NexGen LCCK. Surgical Technique for use with LCCK 4-in-1 Instrumentation. Contact your Zimmer representative or visit us at

Lateral Ankle Instability Repair using TWINFIX Ti 3.5 mm Suture Anchors

Implant Extraction Guide Module One & Two

Hip Arthroscopy Product Guide

Cable System. For Orthopaedic Trauma Surgery.

SURGICAL MANUAL. Step By Step Techniques

Minimally Invasive Hip Replacement through the Direct Lateral Approach

Restorative Manual Impression Transfer System

MGB Chrome Bumper Conversion

Zimmer Segmental System. Distal Femoral Surgical Technique

CALIBRATION FOR LAL20X & LAL24X

Transcription:

PoLARUS 2 Locking Humeral Rod Surgical Technique

The Polarus 2 Locking Humeral Rod is designed to provide fixation for 2-, 3-, and some 4-part fractures of the proximal humerus through a minimally invasive surgical technique. Polarus 2 is a cannulated intramedullary humeral rod that features a tapered profile with a spiral array of proximal screws designed to target the best quality bone. Multi-planar fixation acts as a scaffold, this aids fracture reduction and realignment. One of the additional values of intramedullary rodding compared to competing technologies is its percutaneous approach, designed to minimize soft tissue disruption and support periosteum healing. The Polarus 2 Locking Humeral Rod System is contained in a comprehensive tray including all of the instruments needed to implant the rod and calibrated drills meant to ensure proper screw sizing and eliminate extra surgical steps. Cleared Indications: 2-, 3-, and some 4-part fractures of the proximal humerus Minimally Invasive Fracture Stability Anatomic Restoration Cannulation allows the surgeon to implant the rod percutaneously over a guide wire Calibrated drills and drill guides Tapered Profile and 4º Lateral Bend Radiolucent Targeting Guide Spiral Array of Locking Screws provides multi-planar fracture fixation in the humeral head Contents Surgical Technique 2 Ordering Information 9 5.3 mm Locking Cancellous Screws or 5.0 mm Non-Locking Screws are both compatible with the rod Axillary Nerve Window is designed to reduce the risk of screw placement near vital structures 3.5 mm Distal Screws 1PATIENT POSITIONING AND SURGICAL EXPOSURE The patient may be placed either supine or in a beach chair position to aid fluoroscopy use. A bolster may be used to elevate the shoulder and gain exposure. If an anterolateral approach is indicated, a 3.0-5.0 cm incision is made at the anterolateral aspect of the acromion extending parallel to the fibers of the deltoid. The supraspinatus tendon is then split in the direction of the fibers to expose the proximal humerus posterior to the biceps tendon. It is important not to detach the insertion of the tendon. 2

2CORTEX PERFORATION AND GUIDE WIRE INSERTION The implant insertion point is located approximately 1.0-1.5 cm posterior to the bicipital groove, just medial to the greater tuberosity and just lateral to the articulating surface of the humeral head. The cannulated awl (HR-0200) should be used to perforate the cortex and create an entry hole 10 mm in diameter. Extra care should be taken to ensure the tip is buried no deeper than the groove line on the cannulated awl below the bone surface. If the fracture runs through the insertion site, it may be necessary to create a starting hole at the edge of the fragments with a burr or rongeur. While using the cannulated awl, pass the guide wire (WS-2020) through the awl and into the humeral canal. A guide wire passer (PA-1000) and guide wire T handle (HRDL010) coupled with a rosette knob (MS-0100) are available to aid insertion. ALTERNATE TECHNIQUE USING POWER An optional technique is to perforate the cortex with the 2.8 mm drill (HR-D105) and then pass the guide wire (WS-2020) down the canal. The proximal canal can then be prepared using power with the 10.0 mm bud drill (DRB1015). To aid in guide wire insertion, a guide wire passer (PA-1000) and guide wire T handle (HRDL010) are available in the system. With either standard or power technique, fluoroscopy should be used in both the A/P and oblique planes to ensure the guide wire has not exited the humerus through the fracture site. Note: The length markings on the guide wire to assist in verifying the depth of the final implant. A drill bit may also be used in the proximal fragment as a joystick to aid fracture reduction and realignment. The drill should be positioned to avoid interference with both the rod and targeting guide during insertion. 3

3OPTIONAL FURTHER CANAL PREPARATION The proximal canal may be prepared by using a 10.0 mm cannulated bud drill over the guide wire. Drill with the 10.0 mm bud drill (DRB1015) to a depth of approximately 50-60 mm to allow the rod to pass into the canal. The first groove on the 10.0 mm bud drill indicates a depth of 50 mm. 4ASSEMBLE THE TARGETING GUIDE (FOR ROD HRA-1055-S) If you are utilizing rod number HRA-1055-S Polarus 2-4 degrees (10.0 mm x 5.5 mm X150 mm Standard Rod) use the following steps: A) Attach targeting guide base plate (HRDL007) to Polarus 2-4 degrees lateral targeting guide (HRDL025), securing with a rosette knob (MS-0100). B) Insert locking bolt (HRDL001) into position. C) Assemble implant onto targeting guide base plate, aligning the two reference marks on the implant and targeting guide base plate. Ensure implant is the correct rod number (HRA-1055-S). D) Tighten rod into position with the provided finger wrench (MS- 0611). When assembled properly, the rod should curve toward the lateral targeting guide. ALTERNATE TECHNIQUE FOR ROD WITH A/P SCREW (HR-4D1055-S): If you are utilizing rod number HR-4D1055-S Polarus 2-4 degrees with A/P use the following steps: A) Attach targeting guide base plate (HRDL007) to Polarus 2-4 degrees with AP lateral targeting guide (HRDL024), securing with a rosette knob (MS-0100). B) Insert locking bolt (HRDL001) into position. C) Assemble implant onto targeting guide base plate, aligning the two reference marks on the implant and targeting guide base plate. Ensure implant is the correct rod number (HR-4D1055-S). D) Tighten rod into position with the provided finger wrench (MS- 0611). When assembled properly, the rod should curve toward the lateral targeting guide. E) Optional: Assemble outrigger arm (HRDL005) onto targeting guide base plate and secure with a rosette knob. Attach the AP targeting guide (HRDL028) to the outrigger arm using a rosette knob. Outrigger should be constructed to facilitate anterior to posterior approach according to the fracture pattern addressed. 4

5IMPLANT INSERTION Insert the rod over the guide wire and verify that the proximal end of the rod is 5-10 mm below the cortex to avoid any possible impingement with the rotator cuff. Note that the rod should be inserted with hand pressure. Once proper depth is achieved, the rod and targeting guide may be rotated up to 20º to both align the screws with the bone fragments and to avoid the biceps tendon. To avoid injury to the axillary nerve, do not insert the rod more than 10.0 mm below the cortex. Groove marks on the targeting base plate can be used to verify a depth between 5 and 10 mm below the cortical surface. The depth of the rod may also be verified by inserting a 2.8 mm tap drill (HR-D105) through the small hole (arrowed on the picture) located just above the center hole on the targeting guide. Depth can be verified using fluoroscopy; it is important that the c-arm is exactly parallel to the arm to obtain an accurate image of implant depth. Remember to remove the guide wire prior to drilling. 5

6PROXIMAL SCREW PLACEMENT 5.3 mm locking screws (HCA-L53XX-S) or 5.0 mm nonlocking screws (HCA5XXX-S) may be inserted proximally utilizing the 5.0 mm cannula (HR-5101), probe (HR-5102) and drill guide (HR-5104). If using an A/P screw (using rod HR-4D1055), target the A/P screw hole first in order to avoid the biceps tendon. Choose the desired screw position and create a 2-4 mm stab incision in the skin. Insert the 5.0 mm cannula and probe through the targeting guide. Lightly tap the probe to create a small indentation in the bone to assist with targeting accuracy. Only light tapping should be used on the probe to avoid damaging the lateral cortex. Remove the probe and insert the 5.0 mm drill guide (HR-5102) through the cannula and up to the bone surface. Before drilling, be sure the guide wire is removed. Use fluoroscopy to check that the drill is at the desired depth and that the drill bit has not penetrated the articular surface. Using the depth measurements on the 5.0 mm drill guide, the proper screw length can be determined. If the length reading is between sizes, round down to the shorter screw length. Use the black-handled 3.5 mm hex driver (HD-3500) to insert the screw into the rod. When the groove on the driver shaft aligns with the end of the cannula, the screw is fully seated against the bone. Repeat these steps to install additional proximal screws as required. The Polarus 2 Rod offers two different angles (see images 20 & 21) for additional support in the medial calcar region. These screw trajectories can be targeted using the targeting guide holes with the 3.5 mm indication. Use the 3.5 mm drill guide (HR-3104) coupled with the 2.8 mm drill (HR-D105). Once measuring for correct length, the correct 3.5 mm cancellous screw (HCO3XXX-S) can be inserted. 20 Note that the system includes washers designed to increase the capture of good quality bone. These washers are available under part number: HR-WC50-S. 21 6

7TARGET DISTAL HOLES AND SECURE HUMERAL SHAFT It is important to lock the distal humerus in the correct amount of retroversion relative to the humeral head. The fracture can be rotated under fluoroscopy until the fractures are restored to their anatomical positioning. If a good A/P image of the humeral head is viewed, the forearm can be locked at approximately 30º of external rotation. Insert the 3.5 mm cannula (HR-3101) and probe (HR-3102) into the most distal hole in the targeting guide. Lightly tap the probe against the bone to create a dimple similar to Step 6. The 3.5 mm drill guide (HR-3104) is then inserted through the cannula. Using the 2.8 mm tap drill (HR-D105), drill through both cortices. Leaving the long drill through the rod and both cortices, remove the drill guide and cannula. The drill will help to preserve the positioning of the distal fragment. Place cannula into the other distal hole and dimple the bone. Replace probe with the witness hole drill (HR-3106) to perforate the lateral cortex. Importance is placed on using the witness hole drill because it prevents the primary drill from walking and creates a glide hole for the wider distal screw diameter. Use the 2.8 mm tap drill (HR-D105) to drill through both cortices to a depth of, 1-2 mm through the far cortex. 8INSERT DISTAL SCREWS Insert a 3.5 mm screw into the most proximal of the distal holes with the 2.5 mm hex driver (HD-2500). Verify the screw position under fluoroscopy. The screw should not extend past the medial cortex by more than 1 mm. Remove the provisional drill from distal hole and perforate the near cortex with the witness hole drill. Insert second 3.5 mm distal screw. 7

9INSERT POLARUS ROD CAP The Polarus 2 Rod features 3 different cap height options. Caps are available in 2 mm(hr-0001-s), 4 mm (HR-0024-S), and 8 mm (HR-0028-S) options. Cap height should be chosen based upon the depth of the implant to provide best height while remaining below the articular surface. Place the cap assembly onto the 3.5 mm driver and insert into the top of the rod. Advance the cap until the polyethylene fully engages the threads of the most proximal cancellous screw. It may be helpful to tie a piece of suture under the top of the cap and hold onto the end of the suture while inserting the cap into the Polarus 2 implant in order to keep the cap and driver assembled. To prevent possible cross-threading of the cap upon insertion, thread the cap in a counter-clockwise direction for the first few turns, then turn the cap clockwise until fully seated into the top of the Polarus 2 Rod. 10 REPAIR ROTATOR CUFF It is vital to close the incision in the rotator cuff after rod insertion. Using two figure-of-8 suture patterns, with either number 2 Ethibond or other permanent suture, the small longitudinal incision in the rotator cuff is closed. The deltoid muscle is closed with number 1 Vicryl, followed by 2/0 Vicryl to other superficial soft tissue layers. A subcuticular skin suture is strongly recommended. IMPLANT REMOVAL If the implant requires removal, approach the proximal end of the rod in the same manner as when implanting it. Locate the screws under fluoroscopy and remove the proximal screws. (Note, it may be helpful to leave in the distal screws, or most distal proximal screw, to prevent pushing the rod further down the humeral canal.) Remove the Polarus Cap with the 3.5 mm hex driver. Use the tip of the removal instrument (HRDR001) to core out any ingrown tissue. Screw the removal instrument into the rod. The threaded portion of the removal tool has cutting flutes that will remove bone as it is inserted. The tip will fit into the cannulated hole in the rod to help prevent cross threading. Note that the removal tool will not point straight down the humeral shaft, but will angle laterally about 10º. Advance the removal instrument into the proximal end of the Polarus 2 Rod until it is fully seated. Before using the removal hammer (HRDR002), locate and remove any remaining screws. Failure to do so could result in breaking the screws, rod, and/or the removal tool. After verifying that the screws have been removed, slip the forked end of the removal hammer over the shaft of the tool and slap the rod out of the canal. Repair of the rotator cuff and deltoid should follow similar to Step 10. 8

Ordering Information Instruments 10.0 mm Bud Drill DRB1015 2.5 mm Solid Hex Driver Assembly HD-2500 3.5 mm Solid Hex Driver Assembly HD-3500 Polarus 2 Cortical Awl HR-0200 3.5 mm Targeting cannula HR-3101 3.5 mm Targeting probe HR-3102 3.5 mm drill guide / depth gauge HR-3104 Witness Hole Drill HR-3106 5.0 mm Targeting Cannula HR-5101 5.0 mm Probe HR-5102 5.0 mm Polarus Drill Guide HR-5104 Driver Assistant Cannula HR-5135 2.8 mm Tap Drill (2) HR-D105 Rod Locking Bolt Outrigger Extension Arm Targeting guide base plate assembly Guide Wire "T" Handle Polarus 2-4 Deg with A/P Lat. Tgt Gd. Polarus 2-4Deg Lateral Targeting Guide Polarus Removal Hammer Rosette Knob Polarus 5.0 mm Screw Gage Polarus Removal Instrument HRDL001 HRDL005 HRDL007 HRDL010 HRDL024 HRDL025 HRDR002 MS-0100 HR-SG50 HRDR001.078" X 20" Guide Wire WS-2020 Polarus Guide Wire Passer Locking Bolt Finger Wrench PA-1000 MS-0611 3.5 mm Cortical Screw Tap HR-3107 Polarus Shortened Tap Drill (2) Polarus Plus Lateral Targeting Guide 11 mm x 150 mm Polarus Humeral Rod Broach Assy HRSD105 HRDL009 HR-B115 7.3 mm T-handle Reamer RMT7340 8.3 mm T-handle Reamer RMT8340 Freehand Targeting Guide Polarus Instrument Tray Polarus Plus Distal Targeting Guide AP Lateral Targeting Guide Arm MS-0210 MS-9000 HRDL020 HRDL028 Rods 2-4 deg. 10 mm x 5.5 mm x 150 mm Std. Rod 2-4 deg., 10 mm x 5.5 mm x 150 mm A/P Rod HRA-1055-S HR-4D1055-S 8 mm X 200 mm Polarus Plus Humeral HR-0820-S 8 mm X 220 mm Polarus Plus Humeral HR-0822-S 8 mm X 240 mm Polarus Plus Humeral HR-0824-S 8 mm X 260 mm Polarus Plus Humeral HR-0826-S 8 mm X 280 mm Polarus Plus Humeral HR-0828-S Caps & Washers Polarus Cap Screw Assembly HR-0001-S 4 mm Polarus Cap Screw Assembly HR-0024-S 8 mm Polarus Cap Screw Assembly HR-0028-S Circular 5.0 mm Washer, Cleated 5.3 mm Screws HR-WC50-S 5.3 mm x 20 mm Cancellous Locking Screw HCA-L5320-S 5.3 mm x 22.5 mm Cancellous Locking HCA-L5322-S 5.3 mm x 25 mm Cancellous Locking Screw HCA-L5325-S 5.3 mm x 27.5 mm Cancellous Locking HCA-L5327-S 5.3 mm x 30 mm Cancellous Locking Screw HCA-L5330-S 5.3 mm x 32.5 mm Cancellous Locking HCA-L5332-S 5.3 mm x 35 mm Cancellous Locking Screw HCA-L5335-S 5.3 mm x 37.5 mm Cancellous Locking HCA-L5337-S 5.3 mm x 40 mm Cancellous Locking Screw HCA-L5340-S 5.3 mm x 42.5 mm Cancellous Locking HCA-L5342-S 5.3 mm x 45 mm Cancellous Locking Screw HCA-L5345-S 5.3 mm x 47.5 mm Cancellous Locking HCA-L5347-S 5.0 mm Screws 5.0 mm X 25.0 mm Cancellous Screw HCA5250-S 5.0 mm X 27.5 mm Cancellous Screw HCA5275-S 5.0 mm X 30.0 mm Cancellous Screw HCA5300-S 5.0 mm X 32.5 mm Cancellous Screw HCA5325-S 5.0 mm X 35.0 mm Cancellous Screw HCA5350-S 5.0 mm X 37.5 mm Cancellous Screw HCA5375-S 5.0 mm X 40.0 mm Cancellous Screw HCA5400-S 5.0 mm X 42.5 mm Cancellous Screw HCA5425-S 5.0 mm X 45.0 mm Cancellous Screw HCA5450-S 5.0 mm x 47.5 mm Cancellous Screw HCA5475-S 9

Ordering Information 3.5 mm Screws 3.5 mm X 17.5 mm Cortical Screw HCO3175-S 3.5 mm X 20.0 mm Cortical Screw HCO3200-S 3.5 mm X 22.5 mm Cortical Screw HCO3225-S 3.5 mm X 25.0 mm Cortical Screw HCO3250-S 3.5 mm X 27.5 mm Cortical Screw HCO3275-S 3.5 mm X 30.0 mm Cortical Screw HCO3300-S 3.5 mm X 32.5 mm Cortical Screw HCO3325-S 3.5 mm X 35.0 mm Cortical Screw HCO3350-S 3.5 mm X 40.0 mm Cortical Screw HCO3400-S 3.5 mm X 45.0 mm Cortical Screw HCO3450-S 10

Notes: 11

5885 NW Cornelius Pass Road Hillsboro, OR 97124 (888) 627-9957 www.acumed.net Distributed by: SHD10-04-B Effective: 3/2013 2013 Acumed LLC These materials contain information about products that may or may not be available in any particular country or may be available under different trademarks in different countries. The products may be approved or cleared by governmental regulatory organizations for sale or use with different indications or restrictions in different countries. Products may not be approved for use in all countries. Nothing contained on these materials should be construed as a promotion or solicitation for any product or for the use of any product in a particular way which is not authorized under the laws and regulations of the country where the reader is located. Specific questions physicians may have about the availability and use of the products described on these materials should be directed to their particular local sales representative. Specific questions patients may have about the use of the products described in these materials or the appropriateness for their own conditions should be directed to their own physician.