About DiaMex. IvD Controls

Similar documents
IMMUNOASSAY CONTROL - LEVEL 1 (IA CONTROL 1)

IMMUNOASSAY PREMIUM PLUS LEVEL 3 (IA PREMIUM PLUS 3)

Rapid Screening Tests

EU Declaration of Conformity

Annex to the Accreditation Certificate D-ML according to DIN EN ISO 15189:2014

Bio-Rad Laboratories EXTERNAL QUALITY ASSURANCE SERVICES EQAS. External Quality Assurance Services

P R O D U C T S CATALOG

Company presentation

Company Presentation. Product availability mentioned in this presentation are subject to local regulatory approval

TRI-LEVEL CARDIAC CONTROL (CRD CONTROL 1, 2, 3)

Blood Screening Assays. CTS lab locations where assays are performed are indicated by alpha codes D, P, and T.

Broad Selection of Antibodies & Antigens. for the Diagnostics Industry in North America

PROFICIENCY TESTING. Clinical Laboratory Improvement Amendments (CLIA) DOs and DON Ts. Brochure # 8

Where Convenience Begins. BEP 2000 Advance System. Answers for life.

Infectious Disease Markers (IDMs) Data

Quality Control Products & Services Catalog

Room Temp: 8 Hr. Room Temp: 8Hr. Room Temp: ASAP. Refrigerated (2-8C): 3D. Room Temp: ASAP. Refrigerated (2-8C): 3D

(EMEA/CHMP/BWP/298390/2005)

Anti-Zona Pellucida Antibody Latex Agglutination Test

Immunoassay. Product Portfolio. Part of the IDS group

Liaquat University of Medical & Health Sciences, Jamshoro

LIAISON XL HBsAg Quant

Hepatitis and Retrovirus. LIAISON XL Accurate detection of HIV infection. HIV Ab/Ag FOR OUTSIDE THE US AND CANADA ONLY

cobas 4000 analyzer series Freedom to realize your lab s potential

Subpart H--Participation in Proficiency Testing for Laboratories Performing Nonwaived Testing

COBAS INTEGRA 400 plus

Viral Antigens/Virale Antigene. SARS Proteins/SARS Proteine

Viral Safety of Plasma-Derived Products

HEALTHWAY SCREENING & WELLNESS CENTRE - HEALTH SCREENING PACKAGES

Viral Hepatitis Case Report

WHO Prequalification of Diagnostics Programme PUBLIC REPORT. Product: Genscreen ULTRA HIV Ag-Ab Number: PQDx Abstract

BIOCHEMISTRY DEPARTMENT

cobas 6000 analyzer series The success story continues

Molecular Diagnosis of Hepatitis B and Hepatitis D infections

Toxoplasma gondii IgM ELISA Kit Protocol

Blood Testing Protocols. Disclaimer

BLOOD DONOR TESTING & LOOKBACK STUDIES Shan Yuan, MD Last Updated 2/8/ ABO Typing: Performed each time with each donation

AIR FORCE REPORTABLE EVENTS GUIDELINES & CASE DEFINITIONS

Background: 1) Does your center have effective ways of collecting data from multiple sources to submit to multiple organizations?

ViroGen Catalog. Table of contents

Biokit, S.A. was founded in 1973 with entirely private capital. Its purpose is the research, development, production and distribution of clinical

cobas c 311 analyzer

BEIPH Final Report. QCMD 2010 Hepatitis B Virus DNA (HBVDNA10A) EQA Programme. William G MacKay on behalf of QCMD and its Scientific Council July 2010

Quality Forward. UniCel DxI Access Immunoassay Systems

CatalogNo Product Name Size

MEDICAL NUTRITION THERAPY (MNT) CLINICAL NUTRITION THERAPY Service Time CPT Code

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

Effective Treatment of Lyme Borreliosis with Pentacyclic Alkaloid Uncaria tomentosa (TOA-free Cat s Claw)

Antibodies. for the Diagnostics Industry

PROPOSED DOCUMENT. Global Harmonization Task Force. Title: Principles of In Vitro Diagnostic (IVD) Medical Devices Classification

Streptococcus pneumoniae IgG AB (13 Serotypes), MAID... 7

Recombinant Antibody Fragments, Brochure

INTERPRETATION INFORMATION SHEET

Anti-HCV II Antibody to hepatitis C virus (anti-hcv)

LAB 14 ENZYME LINKED IMMUNOSORBENT ASSAY (ELISA)

D Candotti. Institut National de la Transfusion Sanguine Dept. Agents Transmissibles par le Sang Paris, France

Meridian Healthcare. medical diagnostics & equipment. Professional Product List 2013

Viral Hepatitis APHL survey report

Legacy WEBLink Test Updates

LIAISON XL HCV Ab Accurate diagnosis of the early stage of HCV infection

Determining Donor Eligibility Blood Donor vs. Stem Cell Donor. Wanda Koetz, RN, HPC Clinical Nurse Lead, Memorial Blood Centers ASFA - May 7, 2015

Microbiology Specimen Collection Instructions. Alphabetical List of Microbiology Tests

RealStar HBV PCR Kit /2012

Q3 12 RESULTS. Conference Call. The Diagnostic Specialist

SMF Awareness Seminar 2014

Appendix B: Provincial Case Definitions for Reportable Diseases

LAB 1 - Direct agglutination. Serology-the study of the in vitro reactions between antibody and antigen

Specimen Collection Guide

1.5 Function of analyte For albumin, see separate entry. The immunoglobulins are components of the humoral arm of the immune system.

SCOPE OF ACCREDITATION ISO 15189:2012. SPECTRA LABORATORY, INC. 525 Sycamore Drive Milpitas, CA Claude O. Burdick, M.D.

MYCOLOGY PARASITOLOGY RHEUMATOID FACTORS VIROLOGY SAMPLE COLLECTION

Pollen Allergy. Patient Information

The Regional Virus Laboratory is the only CPA accredited provider of virology services in N. Ireland.

Oral allergy syndrome

FEDERAL PUBLIC SERVICE, HEALTH, FOOD CHAIN SECURITY AND ENVIRONMENT CLINICAL BIOLOGY COMMISSION CLINICAL BIOLOGY SECTION

FS FSC. Abbreviations in common use. Fluid-stable, ready-to-use reagent. Fluid-stable concentrated reagent for measurement on Olympus AU systems

30% Off Cycle 1. Possible Preliminary Discussions With Contract Negotiations

Bureau of Laboratory Quality Standards Page 1 of 6

Use of Nucleic Acid Tests to Reduce the Risk of Transmission of Hepatitis B Virus from Donors

A 28 year old woman, gravida 2, para 1, at 16 weeks gestation informs you that her cat, which she has owned for several years, has toxoplasmosis, as

When is a negative actually a plus? When it s

Committed to innovation and growth

Hepatitis C Monitoring and Complications (and Treatment!) Dr Mark Douglas

2015 Outpatient Chronic Hepatitis B Management

Your Partner in Antibody Development. Product and Service Catalog

Direct Testing Systems and Serology

REF , ProCell, 6 x 380 ml system buffer REF , CleanCell, 6 x 380 ml measuring cell cleaning solution

Mouse Insulin ELISA. For the quantitative determination of insulin in mouse serum and plasma

AU 400 T H E V I S I B L E D I F F E R E N C E A N A L Y S E R S Y S T E M F O R C L I N I C A L C H E M I S T R Y

2.0 Rationale, Purpose and Scope Definitions General Principles... 7

About Our Products. Blood Products. Purified Infectious/Inactivated Agents. Native & Recombinant Viral Proteins. DNA Controls and Primers for PCR

Premarital Screening Standard. Premarital Screening and Counseling Program. Version 1.1

Blood-Based Cancer Diagnostics

How Does a Doctor Test for AIDS?

Cycle prices listed below, now include Cycle Monitoring Bloods at each scan, this represents a saving to our patients of 230 per cycle.

Opinion On Quality and Safety of Blood SCIENTIFIC COMMITTEE ON MEDICINAL PRODUCTS AND MEDICAL DEVICES

ELISA-VIDITEST anti-cmv IgM capture

MHDO CompareMaine Updated: 9/17/2015

The Danish Bone Marrow Donor Registry DBMDR

Hepatitis C. Laboratory Tests and Hepatitis C

Transcription:

About DiaMex IvD Controls

Controls for infection serology ToRCH M Plus 6 ToRCH G Plus 7 MaPaMuVa M 8 Controls for blood bank marker Optitrol A 9 Controls for immunoassays Hormone & Drug 10 Tumor Marker 11 Controls for cardiac marker Cardiac Marker 12 Immunology and proteincontrols Plasma Protein 13 Controls for molecular diagnostics NAT/PCR 14 Controls for allergy tests Respiratory Allergenes 15 Food Allergenes

About DiaMex The center of our efforts is the medical laboratory, where we supply high quality in-vitro-diagnostic products. We offer a range of manufacturer independent controls which are always designed to the customer s requests forming our ready-to-use concept. DiaMex controls fit perfectly into the day-to-day routine of the medical laboratory testing. Our focus is based on the highest standard of quality for a reasonable price. The permanent development of our products and the longterm cooperation with our partners is the drive of our growth. Based on the experience of our associated donor centers in Heidelberg and Munich the development to produce diagnostics for the medical laboratory was a logical step. Regulatory requirements as well as constant improvements determine our efforts to develop quality products. DiaMex is a DIN EN ISO 13485 certified company. 4 Controls The controls of the OPTITROL series are liquid or lyophilized single- and multi-analyte-controls and can be used to test the precision of laboratory systems and help to identify random or systematic errors. Within the technical borderlines they are produced with human raw material and are therefore very similar to a patient sample.

The ready-to-use concept* Our ready-to-use concept means, that the controls may remain directly in the carrier or roboter of the test system. A manual refilling of the controls from the conventional dropper bottles into the vials of the carrier is no longer necessary. Relevant dead volumes at the end of the measurement therefore can be prevented. Advantages of the ready-to-use concept vials developed according to the individual platform (e. g. for ARCHITECT -, PRISM -, LIAISON -, Cobas - or IMMULITE -Systems and others) multimarker controls instead of single controls barcoded controls easy handling: ready to use solutions no reconstitution of lyophilizates no manual refilling no source of fault no contamination no dead volume cost-effective with target values lotreservations are possible efficient and time saving 5 * Dropper bottles are also available for manual test procedures for all common systems.

Infection serology Optitrol ToRCH M Plus Optitrol ToRCH M Plus is a multi-control which can be used to deviations while determining IgM/IgG antibodies to Toxoplasma gondii, Rubella virus, Cytomegalo virus (CMV), Epstein-Barr Virus (EBV-VCA) and only IgG-antibodies to Herpes simplex Virus 1/2 (HSV) and Epstein-Barr Virus (EBV-EBNA) in human plasma and human serum. The ready-to-use vials fit into the carrier of LIAISON - and ARCHITECT i-systems. Fillings in dropper bottles are optimized for microplates. produced with human plasma no additional monoclonal antibodies liquid multi control with coloured screw caps (green = negative control, red = positive control) positive control: contains IgM-/IgG-antibodies to Toxoplasma gondii, Rubella virus, CMV, HSV 1/2, EBV-VCA and EBV-EBNA negative control: contains no antibodies to Toxoplasma gondii, Rubella virus, CMV, HSV, 1/2 EBV-VCA and EBV-EBNA positive control: contains target values for LIAISON and ARCHITECT Closed: 18 months at 2 to 8 C After opening: 90 days at 2 to 8 C Toxo IgM/IgG Rubella IgM/IgG CMV IgM/IgG HSV 1 IgG HSV 2 IgG EBV-VCA IgM/IgG EBV-EBNA IgG 6 Order information Optitrol ToRCH M Plus, vials, ready-to-use IN0107 IN0108 IN0109 IN0110 8 x 2.5 ml Order information Optitrol ToRCH M Plus, dropper bottles IN0155 1 x 5 ml 1 x 5 ml IN0156 1 x 5 ml 1 x 5 ml IN0157 1 x 5 ml 1 x 5 ml IN0158 4 x 5 ml

Infection serology Optitrol ToRCH G Plus Optitrol ToRCH G Plus is a multi-control which can be used to deviations while determining IgG antibodies to Toxoplasma gondii, Rubella virus, Cytomegalo virus (CMV), Herpes simplex Virus 1/2 (HSV), Epstein-Barr Virus (EBV), Measles virus, Mumps virus, Parvovirus B19, Varizella-Zoster-Virus (VZV) and Helicobacter pylori in human plasma and human serum. The ready-to-use vials fit into the carrier of LIAISON - and ARCHITECT i-systems. Fillings in dropper bottles are optimized for microplates. produced with human plasma no additional monoclonal antibodies liquid multi control with coloured screw caps positive control: contains IgG-antibodies to Toxoplasma gondii, Rubella virus, CMV, HSV 1/2, EBV, Measles virus, Mumps virus, Parvovirus B19, VZV and Helicobacter pylori negative control: contains no antibodies to Toxoplasma gondii, Rubella virus, CMV, HSV 1/2, EBV, Measles virus, Mumps virus, Parvovirus B19 and Helicobacter pylori positive control: contains target values for LIAISON and ARCHITECT Closed: 24 months at 2 to 8 C After opening: 90 days at 2 to 8 C Toxo IgG Rubella IgG CMV IgG HSV 1/2 IgG Helicobacter pylori IgG EBV-VCA IgG EBV-EBNA IgG Measles IgG Mumps IgG Parvo B19 IgG VZV IgG 7 Order information Optitrol ToRCH G Plus, vials, ready-to-use IN0101 IN0102 IN0103 IN0104 8 x 2.5 ml Order information Optitrol ToRCH G Plus, dropper bottles IN0151 1 x 5 ml 1 x 5 ml IN0152 1 x 5 ml 1 x 5 ml IN0153 1 x 5 ml 1 x 5 ml IN0154 4 x 5 ml

Infection serology Optitrol MaPaMuVa M Optitrol MaPaMuVa M is a multi-control which can be used to deviations while determining IgM/IgG antibodies to Measles virus, Parvovirus B19, Mumps virus, Varizella-Zoster-Virus (VZV) in human plasma and human serum. The ready-to-use vials fit into the carrier of LIAISON systems. Fillings in dropper bottles are optimized for microplates. produced with human plasma no additional monoclonal antibodies liquid multi control with coloured screw caps (green = negative control, red = positive control) positive control: contains IgM-/IgG-antibodies to Measles virus, Parvovirus B19, Mumps virus and VZV negative control: contains no antibodies to Measles virus, Parvovirus B19 and Mumps virus Closed: 18 months at 2 to 8 C After opening: 90 days at 2 to 8 C Measles IgM/IgG Parvo B19 IgM/IgG Mumps IgM/IgG VZV IgM/IgG 8 Order information Optitrol MaPaMuVa M, vials, ready-to-use IN0301 IN0302 IN0303 Order information Optitrol MaPaMuVa M, dropper bottles IN0351 1 x 5 ml 1 x 5 ml IN0352 1 x 5 ml 1 x 5 ml IN0353 1 x 5 ml 1 x 5 ml

Blood bank marker Optitrol A Optitrol A is a multi-control which can be used to verify the precision of laboratory systems and to detect analytical deviations while determining antibodies in human plasma and human serum to Human Immundeficiency-Virus Type 1, 2 and group O, Human T-lymphotropic Virus I, II, Hepatitis C Virus, Hepatitis B core antigen, Cytomegalovirus and Treponema pallidum, as well as Hepatitis B surface antigen with target values for different analyzers. The ready-to-use vials fit into the carrier of PRISM - and ARCHITECT i-systems. Fillings in dropper bottles are optimized for microplates. produced with human plasma no additional monoclonal antibodies liquid multi control with coloured screw caps positive control: contains IgG-antibodies to CMV, HBc, HCV, HIV 1/2, HTLV I/II, Treponema pallidum and additional HBsAg negative control: contains no antibodies to CMV, HBc, HCV, HIV 1/2, HTLV I/II, Treponema pallidum and no HBsAg both positive- and negative controls are PCR-negative to HBV, HCV and HIV Closed: 18 months at 2 to 8 C After opening: 60 days at 2 to 8 C Order information Optitrol A, vials ARCHITECT, ready-to-use IN0201 IN0202 IN0203 IN0204 8 x 2.5 ml ARCHITECT Anti-HIV 1 Anti-HTLV II Anti-HIV 1 group O Anti-Treponema Anti-HIV 2 pallidum IgG Anti-HCV IgG Anti-HBc IgG HBsAg Anti-CMV IgG Anti-HTLV I 9 Order information Optitrol A, vials Prism, ready-to-use IN0205 6 x 5 ml 6 x 5 ml IN0206 6 x 5 ml 6 x 5 ml IN0207 3 x 5 ml 3 x 5 ml 6 x 5 ml Prism Anti-HIV 1 Anti-HTLV II Anti-HIV 1 group O Anti-HTLV I Anti-HIV 2 Anti-HCV IgG HBsAg Anti-HBc IgG Order information Optitrol A, dropper bottles IN0251 1 x 5 ml 1 x 5 ml IN0252 1 x 5 ml 1 x 5 ml IN0253 IN0254 1 x 5 ml 1 x 5 ml 4 x 5 ml Anti-HIV 1 Anti-HTLV II Anti-HIV 1 group O Anti-Treponema Anti-HIV 2 pallidum IgG Anti-HCV IgG Anti-HBc IgG HBsAg Anti-CMV IgG Anti-HTLV I

Immunoassays Optitrol Hormone & Drug Optitrol Hormone & Drug is a multi-control which can be used to deviations. The most important analytes in the area hormone and drug level are covered with this control. The ready-to-use vials fit into the carrier of LIAISON -, Cobas - and ARCHITECT i-systems. on the base of human serum as matrix great range of analytes available in three clinical relevant concentrations liquid multi control with coloured screw caps (green = level 1, yellow = level 2, red = level 3) positive control: contains target values for all common analyzers Closed: 5 years at -20 C 6 months at 2 to 6 C After opening: 30 days at 2 to 6 C 10 AFP Aldosterone Amikacin Carbamacepine Chinidin Chloramphenicol CK-MB (mass) Cortisol DHEA-Sulfate Digoxin Disopyramide Estradiol Estriol Ethosuximide Ferritin free T 3 free T 4 FSH Gentamicin HCG hgh Hydroxyprogesterone IgE Insulin LH Lidocaine NAPA Paracetamol Phenobarbital Phenytoin Primidone Procainamide Progesterone Prolactin Salicylate ß-HCG Testosterone Theophylline Tobramycin total T 3 total T 4 TSH Valproic Acid Vancomycin Vitamin B 12 Order information Optitrol Hormone & Drug, vials, ready-to-use HD0101 Control Level 1 6 x 2.5 ml 6 x 2.5 ml HD0102 Control Level 2 6 x 2.5 ml 6 x 2.5 ml HD0103 Control Level 3 6 x 2.5 ml 6 x 2.5 ml HD0104 Control Level 1 Control Level 2 Control Level 3 6 x 2.5 ml

Immunoassays Optitrol Tumor Marker Optitrol Tumor Marker is a multi-control which can be used to deviations. The ready-to-use vials fit into the carrier of IMMULITE - and ARCHITECT i-systems. Fillings in dropper bottles are optimized for microplates. on the base of human serum as matrix available in two clinical relevant concentrations liquid multi control with coloured screw caps (green = level 1, yellow = level 2) positive control: contains target values for all common analyzers Closed: 5 years at -20 C 6 months at 2 to 6 C After opening: 60 days at 2 to 8 C AFP CA 125 CA 15-3 CA 19-9 CA 50 CA 549 CA 72-4 CEA Cyfra 21-1 Ferritin HCG MCA PSA SCC TPA TPS 11 Order information Optitrol Tumor Marker, vials, ready-to-use TM0101 Control Level 1 TM0102 Control Level 2 TM0103 Control Level 1 Control Level 2 4 x 2 ml Order information Optitrol Tumor Marker, dropper bottles TM0151 Control Level 1 4 x 2 ml 4 x 2 ml TM0152 Control Level 1 4 x 2 ml 4 x 2 ml TM0153 Control Level 1 Control Level 2 4 x 2 ml

Cardiac Marker Optitrol Cardiac Marker Optitrol Cardiac Marker is a multi-control which can be used to deviations. The ready-to-use vials fit into the carrier of the ARCHITECT i-systems. Fillings in dropper bottles are optimized for microplates. on the base of human serum as matrix available in two clinical relevant concentrations liquid multi control with coloured screw caps (green = level 1, yellow = level 2) positive control: contains target values for all common analyzers Closed: 5 years at -20 C 30 days at 2 to 6 C* After opening: 30 days at 2 to 6 C* *TnT und NT-proBNP 14 days at 2 to 6 C Tn I 4 days at 2 to 6 C CK-MB (mass) Homocysteine Myoglobin NT-proBNP Troponin I Troponin T 12 Order information Optitrol Cardiac Marker, vials, ready-to-use CM0101 Control Level 1 4 x 2 ml 4 x 2 ml CM0102 Control Level 2 4 x 2 ml 4 x 2 ml CM0103 Control Level 1 Control Level 2 4 x 2 ml Order information Optitrol Cardiac Marker, dropper bottles CM0151 Control Level 1 4 x 2 ml 4 x 2 ml CM0152 Control Level 2 4 x 2 ml 4 x 2 ml CM0153 Control Level 1 Control Level 2 4 x 2 ml

Immunology and proteins Optitrol Plasma Protein Optitrol Plasma Protein is a multi-control which can be used to deviations. The ready-to-use vials fit into the carrier of BN ProSpec and ARCHITECT i-systems. Fillings in dropper bottles are optimized for microplates. on the base of human serum as matrix available in three clinical relevant concentrations liquid multi control with coloured screw caps (green = level 1, yellow = level 2, red = level 3) positive control: contains target values for all common analyzers Closed: 5 years at -20 C 6 months at 2 to 6 C* *Apo A1 1 month, Coeruloplasmin 3 months at 2 to 6 C After opening: 60 days at 2 to 6 C* Albumin Antistreptolysin O Antithrombin III Apo A1 Apo B C 3 C 4 Coeruloplasmin CRP Ferritin Haptoglobin Hemopexin IgA IgE IgG IgM Prealbumin RBP Rheumatoid Factor Transferrin Transferrin-Receptor α-1-antitrypsin α-1-glycoprotein α-2-macroglobulin β-2-microglobulin κ-light Chains λ-light Chains 13 Order information Optitrol Plasma Protein, vials, ready-to-use PP0101 Control Level 1 6 x 2 ml 6 x 2 ml PP0102 Control Level 2 6 x 2 ml 6 x 2 ml PP0103 Control Level 3 6 x 2 ml 6 x 2 ml PP0104 Control Level 1 Control Level 2 Control Level 3 6 x 2 ml Order information Optitrol Plasma Protein, dropper bottles PP0151 Control Level 1 4 x 2 ml 4 x 2 ml PP0152 Control Level 2 4 x 2 ml 4 x 2 ml PP0153 Control Level 3 4 x 2 ml 4 x 2 ml PP0154 Control Level 1 Control Level 2 Control Level 3 1 x 2 ml 1 x 2 ml 1 x 2 ml 3 x 2 ml

Molecular diagnostics Optitrol NAT/PCR Controls Optitrol NAT/PCR Controls can be used as run-to-run controls to deviations. The range of Optitrol NAT/PCR Controls offers single controls for HIV 1, Hepatitis B (HBV), Hepatitis C (HCV). When using NAT based in-vitro-diagnostic tests against HIV 1, HBV and HCV there will always be a positive result. Target values were detected for the following test systems with n=10: msample Preparation System / m2000sp-system (Abbott), QIAamp DSP Virus Kit / Rotor-Gene Q 5-plex (Qiagen), COBAS AmpliPrep / COBAS TaqMan (Roche), High Pure System Viral Nucleic Acid Kit / COBAS TaqMan (Roche). The controls can also be used for different analyzers and procedures, like e.g. TMA or manual preparation. Optitrol NAT/PCR Controls are directly produced with positive human plasma. Therefore they contain native viruses and no artificial samples of sequences of nucleic acids. This guarantees a high comparability to native patient samples. Optitrol NAT/PCR Controls are set up for a concentration of viruses at 5000 IU/ml (COBAS AmpliPrep / COBAS TaqMan). produced with human plasma liquid single control contains native viruses with coloured screw caps (green = HBV, yellow = HIV, blue = HCV) 14 Closed: 1 year at -20 C After opening: 4 hours at 2 to 8 C HIV HBV HCV Order information Optitrol NAT/PCR, vials NT0101 NT0102 NAT HIV NAT HIV 8 x 1.2 ml 30 x 1.2 ml 8 x 1.2 ml 30 x 1.2 ml NT0103 NT0104 NAT HBV NAT HBV 8 x 1.2 ml 30 x 1.2 ml 8 x 1.2 ml 30 x 1.2 ml NT0105 NT0106 NAT HCV NAT HCV 8 x 1.2 ml 30 x 1.2 ml 8 x 1.2 ml 30 x 1.2 ml

Allergy tests Optitrol Allergy Controls Optitrol Food Control is a multi-control which can be used to deviations while determining IgE-antibodies to various foods. produced with human plasma liquid multi control no additional monoclonal antibodies positive control: contains IgE-antibodies to foods like described below with target values Optitrol Respiratory Control is a multi-control which can be used to verify the precision of laboratory systems and to detect analytical deviations while determining IgE-antibodies to different aeroallergenes. produced with human plasma liquid multi control no additional monoclonal antibodies positive control: contains IgE-antibodies to aeroallergenes like described below with target values Closed: 18 months at 2 to 8 C After opening: 90 days at 2 to 8 C food: 15 f 13 peanut f 14 soybean f 17 hazelnut f 256 walnut f 12 pea f 31 carrot f 85 f 49 f 33 f 84 f 4 f 5 celery apple, green orange kiwi wheat flour rye flour f 25 tomato f 218 pepper, spice f 48 onion f 91 mango f 92 banana respiratory: d 1 d 2 d 70 i 6 t 2 t 3 t 4 t 7 dermatophagoides pteronyssinus dermatophagoides farinae acarus siro cockroach alder birch hazel oak g 12 rye w 1 ambrosi, artemisiifolia w 2 ambrosi, perennial ragweed w 6 mugwort w 7 maguerite w 9 buckhorn plantain w 20 nettle w 206 camomile pollen i 1 i 3 k 82 e 1 e 3 e 5 bee venom wasp venom latex (hevea brasil.) cat epithelia horse epithelia dog epithelia

www.diamex.com