VMM ELEKTROGAS MULTIPLE SAFETY SOLENOID VALVE FOR REGULATING TRAINS

Similar documents
820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

HERZ-Thermal Actuators

Assisted lift operated 2/2-way solenoid valves Type EV250B

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Solenoid valves 2/2-way direct-operated Type EV210A

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Mini Solenoid Valve

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

PRESSURE REGULATOR SERIES R 4100 R 2100 R 5100 VIRTUAL CATALOGUE FAIL TO OPEN REGULATOR BALANCED VALVE HIGH FLOW COEFFICIENT

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

4/2-Way Pneumatic Solenoid Valve

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Volvo Penta Quality Line Marine Water Heaters. Owners Manual

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

PRESSURE REDUCING VALVES

M A N U A L

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

How To Use A Flowmeter

System 8. ü ( System 8

Solenoid valves Type EVU

TWO STAGE GAS BURNERS RIELLO 40 GSD SERIES GS10D 29/ kw GS20D 58/ kw

SOLENOID VALVE FOR REFRIGERATING SYSTEMS

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

PRESSURE REDUCING CONTROL VALVE

T U R B I N E G A S M E T E R

Submersion/Insertion Toroidal Sensor

Digital inductive conductivity transmitter

DR125 and DR150 Hensim Dirt Runner 125cc and 150cc Dirt Bike (VIN PREFIX LLCH or LUAH)

Hydraulic Control Solutions

Cable Plug acc. to DIN EN , Form A

Fluxi 2000/TZ Turbine Gas Meter

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

3/2- and 2/2-way cartridge valve type BVE

Data sheet ECC 12 and 22

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

STABITHERM INSTALLATION & SERVICE BOOKLET

GAS VALVE USER MANUAL

3/2-way pneumatic cartridge solenoid valve

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Manual piston sampler...m 11

INSTALLATION, OPERATION & MAINTENANCE MANUAL

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

OPL BASIC. Dosing System for Professional Laundry machines. Contents

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

High Flow High Pressure Solenoid Valve. Double 3/2 N.C. solenoid valve with manual override

! WARNING. Before using product, read and understand instructions.

series Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN CW617N

Vacuum drying oven for non-flammable solvents

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Material test chamber with mechanical convection

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

1/29/2008 DR125 / DR150. Baja Motorsports Inc. P.O. Box Phoenix, AZ Toll Free: PARTS AND PRICES ARE SUBJECT TO CHANGE 1 of 55

Oil - kerosene burners

Installation and maintenance instructions. Danfoss Vent

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

COMMERCIAL GAS DRYER

Operating Instructions

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

I.T BSV-N series 25 ELECTROMECHANICAL TURRETS TECHNICAL INFORMATION ISSUED

OLI. Oil level indicator

Duct Humidity Transmitter

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Operator: Save these instructions for future use!

Compact pressure switch Flameproof enclosure Ex d Model PCA

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

SELECTION, APPLICATION AND MAINTENANCE

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS VS VS VS VS

CRANE. Σελίδα 1 από 2. Dimensions and Weights. Weight (kg) Size

Maintenance and Operating Instructions SIS 120P/SISF

BB-18 Black Body High Vacuum System Technical Description

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

1805 Series Relief Valves

VALVES FOR REFRIGERATING SYSTEMS

Self-operated Temperature Regulators Temperature Regulator Type 1u

B MOTORSPORT COMPONENTS B13. Max Circuit Measurement Characteristic Current Thread Part Number Range Curve [A] Size Connector Figure Comment

1/29/2008 DR70. Baja Motorsports Inc. P.O. Box Phoenix, AZ Toll Free: PART NUMBERS PRICES ARE SUBJECT TO CHANGE 1 of 43

1 DESCRIPTION OF THE APPLIANCE

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

RI27-J CNG REDUCER INSTALLATION PROVISIONS & WARNINGS

Series 8146/5-V37 and Series 8150/5-V37

Wet alarm valves. Wet alarm valves. FM trim

Direct steam injection humidifiers

Instruction Manual Differential Pressure Transmitter

Transformer oil cooler ALFA A02

RUBBER SLEEVE KNIFE GATE VALVE

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Transcription:

VMM MULTIPLE SAFETY SOLENOID VALVE FOR REGULATING TRAINS E050

VMM MULTIPLE SAFETY SOLENOID VALVE CLASS A - GROUP 2 The VMM type valve is a combination of two valves in an only compact and versatile valve housing. The first valve (A) is a fast opening solenoid valve that is safety. The second valve (B) may be a fast opening or a slow opening solenoid valve to adjust the gas flow, with a first adjustable fast stroke and a second adjustable slow stroke. It is possible connect a third by-pass valve (C), which performs by driver stage or to obtain a second fast (slow) stroke or both. APPLICATION This type of device is suitable for gas and air blocking and adjusting controls in atmospheric burners or fanassisted burners (with one or two stages operation), in industrial ovens and in all gas equipments which use regulating trains. INSTALLATION AND ADJUSTMENT Check correspondence of flow direction with arrow printed on valve body, check correct alignment of connecting pipes and allow enough space from the walls to allow free air circulation. Valve may be mounted with coil in horizontal or vertical position. Coil may be oriented 360 degrees in any direction (do not use unit as lever). Install in an area that is protected from rain and water splashes or drops. In the slow valve capacity may be adjusted from 0 cubic meters/h to the maximum marked on the plate by turning internal adjustment screw under the upper cap (9), and by turning the outer screw, the length of the rapid flow section may be adjusted (8). Make sure that capacity adjustments are made while burner is in operation. Adjustments below 40% capacity are unadvisable since they may cause turbulence. It is also possible to regulate open time by turning the screw located on the side of the shock absorber (7). One fourth of a turn clockwise increases open time by 2 3 s, up to a maximum of about 25 s (slow run). Manufacture calibration is about 14 s. By-pass capacity may be adjusted too (6): remove the coil fastener cap and turn adjustment screw under locking dowel. When adjustment is completed screw back locking dowel and all the caps. Use proper tools only. ELECTRICAL CONNECTION Remove protection cover and connect power cables to rectifier circuit terminal board (5). Should cables pass through originally closed opening, use the rubber capsule placed underneath the cap to close any other opening. When connection is completed replace gasket and screw back cover. CLEANING AND MAINTENANCE Dust and any foreign bodies may be easily removed from the filter (3, to the inside of the inlet connection flange) or the gas passage zone. After shutting off upstream gas and electric current, the coil is removed by unscrewing the shock absorber located on its top. Great care should be taken not to force the rod sideways, and to check cleanliness and centering of the 2 sealing O-Rings. Unscrew the 8 screws fixing the counter flanges to valve body. During this operation care should be taken not to cause damage to the seat housing and the Teflon sliding clamps. Avoid dissembling or tampering with the shock absorber. TECHNICAL CHARACTERISTICS f/f Connections : gas threaded from 1"1/4, 1"1/2 and 2" By-pass size : 1/2" and 1" Voltage rating : 230V 50/60Hz (by request 110V 50/60Hz) Power absorption : 160W (without by-pass) by-pass 1/2" 25W, by-pass 1" 45W Voltage tolerance : -15% + 10% Working temperature : -15 C + 60 C Compatible gas range : all gases according to EN437 Max working pressure : 200-360 mbar Opening/Closing time : < 1 second Protection class : IP 54 Cable gland : PG11 Pressure inlets : nr. 8 (10) from G1/4" on two sides and on connection flanges Standard filter : brass wire 600µ Executed according to EN161 rule in force. GASTEC PIN ratification: 0063AQ1350, October 1999 This control must be installed in compliance with the laws in force. Elektrogas reserves the right to update or make technical changes without prior advice. E051

ADJUSTMENT 1 = Connection flange 2 = G1/4" pressure gauge 3 = Filter 4 = Measurement connection (optional) 5 = Electrical connections 6 = By-pass flow adjustment 7 = Opening speed adjustment 8 = Rapid stroke adjustment 9 = Flow adjustment A = First valve B = Second valve C = By-pass valve X = Inlet chamber Y = Middle chamber Z = Outlet chamber E052

VALVE IDENTIFICATION VMM 50 2 A S 1 0 Valve type Connections size 32 = 1"¼ (DN32) 40 = 1"½ (DN40) 50 = 2" (DN50) Max pressure working 2 = 200 mbar 3 = 360 mbar Supply voltage A = 230V 50/60Hz B = 110V 50/60Hz Second valve type F = fast S = slow By-pass valve on the Right side (seen from the inlet) 0 = none 1 = 1/2" (DN15) Fast 2 = 1/2" (DN15) Slow 3 = 1" (DN25) Fast 4 = 1" (DN25) Slow By-pass valve on the Left side (seen from the inlet) 0 = none 1 = 1/2" (DN15) Fast 2 = 1/2" (DN15) Slow 3 = 1" (DN25) Fast 4 = 1" (DN25) Slow Accessories fitted on request Pressure gauge Pressure switch Limit switch E053

DIAGRAM LOSS OF PRESSURE LOSS OF PRESSURE mmh O 2 Air Methane Town gas FLOW RATE (m /h) 3 DN50-2" DN40-1"½ DN32-1"¼ LOSS OF PRESSURE mbar FORMULA OF CONVERSION FROM AIR TO OTHER GASES GAS TYPE SPECIFIC GRAVITY K (Kg/m³) Natural Gas 0.80 1.25 Town Gas 0.57 1.48 Liquid Gas 2.08 0.77 Air 1.25 1.00 E054

SYNOPTIC TABLE 1 = Adjustable pressure switch (Min) 2 = Adjustable pressure switch (Max) 3 = Valve leakage tester 4 = Limit switch 5 = Limit switch 6 = Burner pressure gauge A = First valve B = Second valve C = By-pass valve X = Inlet chamber Y = Middle chamber Z = Outlet chamber In the VMM type valve are available eight (ten without by-pass) G1/4" pressure gauge on two sides and on connection flanges to connect several control devices. The assemblage of any accessories could exclude the fitting of other devices. E055

OVERALL DIMENSIONS H F G E A B C D A B C D E F G H Kg VMM.F00 Gas threaded 211 280 138-170 230 148 13,0 VMM.S00 Gas threaded 211 280 138-245 305 148 13,7 VMM.S10 Gas threaded 211 280 138 190 245 305 200 15,3 VMM.S20 Gas threaded 211 280 138 252 245 305 200 15,5 VMM.S30 Gas threaded 211 280 138 198 245 305 220 16,3 VMM.S40 Gas threaded 211 280 138 260 245 305 220 16,5 E056