Application Note 177 INTRODUCTION

Similar documents
Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

A Complete Solution for Method Linearity in HPLC and UHPLC

Determination of Calcium and Magnesium in Brine

TECHNICAL BULLETIN. HIS-Select Nickel Affinity Gel. Catalog Number P6611 Storage Temperature 2 8 C

Application Note. Separation of three monoclonal antibody variants using MCSGP. Summary

for IonSwift TM MONOLITH ANION CONCENTRATOR (MAC)

Determination of Fat in Dried Milk Products Using Accelerated Solvent Extraction (ASE)

Application Note. Purifying common light-chain bispecific antibodies using MCSGP. Summary

Development of an Automated Method for Monoclonal Antibody Purification and Analysis. Introduction. Gurmil Gendeh, 1 Wim Decrop, 2 and Remco Swart 2 1

Optimal Conditions for F(ab ) 2 Antibody Fragment Production from Mouse IgG2a

Application Note. Increasing the activity of monoclonal antibody isoforms by MCSGP. Summary

Application Note. USD 2995 (a) High Throughput Regeneration Study on MEP HyperCel Mixed-Mode Sorbent on ScreenExpert RoboColumns u

Monoclonal Antibody Characterization Achieving Higher Throughput and Productivity

The Determination of Sugars in Molasses by High-Performance Anion Exchange with Pulsed Amperometric Detection

Monoclonal Antibody Fragment Separation and Characterization Using Size Exclusion Chromatography Coupled with Mass Spectrometry

Optimize Your Process Operations by Improving Process Monitoring

Analytical Test Report

Transforming a ChromLab Software 2-D Purification Template into an Automated Multidimensional (Multi-D) Purification Workflow An Instructional Guide

POROS CaptureSelect affinity columns for highspeed quantification of IgG Fc fusion proteins

Standard Operating Procedure for Total Kjeldahl Nitrogen (Lachat Method)

Gel Filtration Standard

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns

Process-scale purification of monoclonal antibodies polishing using Capto Q

ENrich SEC 70 ENrich SEC 650 High-Resolution Size Exclusion Columns Instruction Manual

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Environmental Analysis Using the ICS-3000 Ion Chromatography System

Robert Birdsall, Eoin Cosgrave, Henry Shion, and Weibin Chen Waters Corporation, Milford, MA, USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

SUCRALOSE. White to off-white, practically odourless crystalline powder

INTRODUCTION. The principles of which are to:

columns IonPac CS18 Cation-Exchange Column

RESOURCE Q, 1 ml and 6 ml RESOURCE S, 1 ml and 6 ml

Accurate and Precise Automated Dilution and In-line Conductivity Measurement Using the AS-AP Autosampler Prior to Analysis by Ion Chromatography

Separation of Peptides from Enzymatic Digestion on Different Acclaim Columns: A Comparative Study

TECHNICAL BULLETIN. FluoroTag FITC Conjugation Kit. Product Number FITC1 Storage Temperature 2 8 C

Affi-Prep Protein A Matrix Instruction Manual

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

[ Care and Use Manual ]

SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Henry Shion, Robert Birdsall, Steve Cubbedge, and Weibin Chen Waters Corporation, Milford, MA, USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

Technical Procedure for the Solid Phase Extraction of Acidic, Neutral and Basic Drugs for GC-MS Analysis

Sensitive and Rapid Determination of Polycyclic Aromatic Hydrocarbons in Tap Water

Protocol: HPLC (amino acids)

What is Eluent Generation?

ab Protein Sumoylation Assay Ultra Kit

Data File. Sephadex G-25 media and pre-packed columns. Introduction. Sephadex G-25 Bead structure. Desalting/buffer exchange and gel filtration

Size Exclusion Chromatography

BUFFERS and MEDIAS Coomassie Blue Staining Solution Coomassie blue Destaining Solution DMEM Normal Cell Culture Media

α-cyclodextrin SYNONYMS α-schardinger dextrin, α-dextrin, cyclohexaamylose, cyclomaltohexaose, α- cycloamylase

NimbleGen DNA Methylation Microarrays and Services

Assay for Citrate and Phosphate in Pharmaceutical Formulations Using Ion Chromatography

Glutathione Resin. User Manual. User Manual. Cat. Nos , , PT (071414)

6 Characterization of Casein and Bovine Serum Albumin

Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates

Quantification of Trace and Major Anions in Water by Ion Chromatography in a High-Throughput Laboratory

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Thermo Scientific PepFinder Software A New Paradigm for Peptide Mapping

Tamsulosin Hydrochloride Capsules

Recent advances in the purification of IgM monoclonal antibodies

How To Use An Acquity Qda Detector

Continuous Chromatography for Monoclonal Antibody Purification from Cell Culture Supernatant

Determination of Catecholamines in Human Plasma by Liquid Chromatography with Electrochemical Detection

PROTEIN SEQUENCING. First Sequence

AFFINITY CHROMATOGRAPHY

HiPer Ion Exchange Chromatography Teaching Kit

INSTRUCTIONS Edition AC

Monitoring Protein PEGylation with Ion Exchange Chromatography

Amino Acid Analyzer L-8900

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Simultaneous determination of aspartame, benzoic acid, caffeine, and saccharin in sugar-free beverages using HPLC

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

POROS CaptureSelect affinity columns for rapid, small-scale purification and sample preparation of recombinant proteins

ERDOSTEINE - MONOGRAPH.

Using the AS Automated Sampler in the Simultaneous, Sequential, and Concentrate Modes

FerroVer Method 1 Method to 3.0, 1.0 to 30.0 and 10.0 to mg/l Fe Powder Pillows

Application Note USD3013. Monoclonal Antibody Production in Suspension CHO Culture Using Single-Use PadReactor Mini Bioreactor

Anion chromatography using on-line recycled eluents

Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software

DNA Assembly and Enzymatic Cutting in Solutions: A Gold Nanoparticle Based SERS Detection Strategy

Carbohydrate in Coffee: AOAC Method vs a New Fast Ion Chromatography Method

Application Note. Determination of Amino acids by UHPLC with automated OPA- Derivatization by the Autosampler. Summary. Fig. 1.

Comparison of the Reversed-Phase Selectivity of Solid Core HPLC Columns

IC-MS and LC-MS Determination of Ionic Liquids, Counterions, and Impurities

MabSelect SuRe. GE Healthcare Life Sciences

Project 5: Scoville Heat Value of Foods HPLC Analysis of Capsaicinoids

TIANquick Mini Purification Kit

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

[ Care and Use Manual ]

PRACTICAL 3: DIGESTIVE ENZYMES, SPECIFICITY AND ph

USEPA 1 FerroVer Method 2 Method to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls

Choose your optimal tools for protein studies

His GraviTrap. GE Healthcare. Operation

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Marmara Üniversitesi Fen-Edebiyat Fakültesi Kimya Bölümü / Biyokimya Anabilim Dalı PURIFICATION AND CHARACTERIZATION OF PROTEINS

Antibody Purification and Labeling

Determination of Carbonyl Compounds by Reversed-Phase High-Performance Liquid Chromatography

Bringing Downstream Productivity into Phase with Upstream Antibody Production

Enhanced Organic Precursor Removals Using Aged Filter Media Page 1. Enhanced Organic Precursor Removals Using Aged Filter Media

Southern Blot Analysis (from Baker lab, university of Florida)

Research for leachables of nuclear grade cation exchange resin

Transcription:

Application Note 177 Separation of an Intact Monoclonal Antibody and Fractionation of Monoclonal Antibody Papain Digest Fragments Using Immobilized Metal Affinity Chromatography (IMAC) INTRODUCTION Monoclonal antibodies (MAbs) have been indispensable for the development of a wide range of products in the clinical and biological fields. For example, MAbs can be used as diagnostic agents or therapeutic treatment for many diseases. 1,2 The most basic antibody structure has a Y shape and contains two heavy and two light polypeptide chains. The four chains are linked together by disulfide bonds. 1 Proteolytic cleavage with enzymes such as papain, pepsin, and ficin results in defined antibody fragments. The analysis of antibody fragments offers several advantages over intact antibodies. For example, the separated antigen-binding fragment (i.e., Fab region) can be used for antigen-antibody binding studies without interference from the non-antigen binding fragment (i.e., Fc region) and simplifies the characterization of MAb variants. Antibody fragments can be fractionated using various methods, including cation-exchange chromatography, isoelectric focusing, protein A affinity chromatography, and immobilized metal affinity chromatography (IMAC). 2 4 Protein A has been the most common technique used for the separation and purification of MAb fragments. Protein A is a cell wall component produced from several strains of Staphylococcus aureus that specifically binds the Fc region of IgG. The disadvantages of protein A fractionation are: protein A substrates often contaminate MAb samples with biological leachates and extreme eluent conditions can result in degradation of the sample during fractionation. Therefore, there is increasing demand for new separation media that are nonbiological and use mild eluents. IMAC has emerged as a powerful technique for fractionating MAb Fc and Fab due to the high affinity of the Fc region for immobilized copper. However, common limitations of commercially available IMAC columns include low chromatographic efficiency and resolution, excessive nonspecific binding, difficulty automating and monitoring separations, and low backpressure limits that limit flow rates. The ProPac IMAC-10 substrate was developed to address the limitations of the currently available IMAC columns. The performance of this IMAC column was improved by using a high-resolution 10-µm nonporous polystyrene divinylbenzene substrate bead. The dense, hydrophilic inner layer shields the polymeric beads and inhibits hydrophobic interaction between the analyte and substrate. This hydrophilic layer contains grafted iminodiacetate (IDA) groups via controlled radical polymerization that collapse into surface-bound nanoparticles upon loading the column with the copper metal. The chain length and, therefore, nanoparticle size were optimized to correspond with the approximate size of the MAb Fc region. This application note describes a method for fractionating IgG1 MAb Fc and Fab fragments with the ProPac IMAC-10 column preloaded with copper and analyzing the fractions using the ProPac WCX-10 column. Application Note 177

The experimental procedure is broken into three stages, each having its own reagents, sample preparation, experimental conditions, and procedures for the application of the mobile phases: Stage 1: Pretreatment of the ProPac IMAC-10 column to convert the column to the copper form Stage 2: Separation of the intact and papain digested MAbs with the ProPac IMAC-10 column (copper form) Stage 3: Separation and analysis of the intact and papain digested MAb fragments on the ProPac WCX-10 column. EQUIPMENT A Dionex ICS-3000 Chromatography system consisting of: DP Dual Pump module DC Detector/Chromatography module AD25 UV/Vis Absorbance Detector with 10-mm cell AS Autosampler Chromeleon Chromatography Management Software REAGENTS Deionized water, Type I reagent grade, 18.2 MΩ-cm resistivity or better Sodium Phosphate, anhydrous dibasic powder (Na 2 HPO 4 ) (J.T. Baker, VWR P/N JT4062-1) Sodium Phosphate, monobasic (NaH 2 PO 4 H 2 O) (EM Science, VWR P/N EM-SX0710-1) Sodium Chloride, NaCl (J.T. Baker, VWR P/N JT3625-1) 2-(N-Morpholino)ethanesulfonic acid, (MES) (Sigma-Aldrich M-5287) Imidazole (Fluka Biochemika 56749) Ethylenediaminetetraacetic acid, disodium salt dihydrate, EDTA (Sigma-Aldrich E4884) L-cysteine (Sigma-Aldrich C7352) Copper (II) Sulfate, pentahydrate (CuSO 4 5H 2 O) (J.T. Baker, VWR P/N JT1841-1) HEPES (Aldrich 233889) Papain (Roche 1010814001) Monoclonal IgG1 antibody (a generous gift from a biotechnology company) Experimental Stage 1: Pretreatment of the propac IMAC-10 Column (Conversion to copper form) Mobile Phases Required for Loading the ProPac IMAC-10 Column with Cu 2+ The following four mobile phases are required for loading the column with copper: Mobile Phase A: 20 mm MES + 200 mm NaCl Mobile Phase B: 20 mm HEPES + 500 mm NaCl + 500 mm imidazole (ph 7.5) Mobile Phase C: 50 mm CuSO4 + 500 mm NaCl (ph 4.0) Mobile Phase D: 50 mm EDTA + 500 mm NaCl (ph 7.0) Preparation of Mobile Phase Solutions Mobile Phase A: 20 mm MES + 200 mm NaCl Combine 3.904 g MES and 11.688 g NaCl in a 1-L volumetric flask containing about 500 ml of degassed deionized water. Bring the volume to about 975 ml with deionized water, stir to dissolve, adjust the ph to 5.5 with 1 M NaOH, and then fill to a final volume of 1 L. Mobile Phase B: 20 mm HEPES + 500 mm NaCl + 500 mm imidazole (ph 7.5) Combine 5.206 g HEPES, 29.22 g NaCl, and 34.04 g imidazole in a 1 L volumetric flask containing about 500 ml of degassed deionized water. Bring the volume to about 975 ml, stir to dissolve the mixture, adjust the ph to 7.5 with concentrated HCl, and bring the total volume to 1 L. Mobile Phase C: 50 mm CuSO 4 + 500 mm NaCl (ph 4.0) Combine 12.484 g CuSO 4 and 29.22 g NaCl in a 1 L volumetric flask containing about 500 ml of degassed deionized water. Bring the volume to about 975 ml and adjust the ph to 4.0 with 1 M HCl. Mobile Phase D: 50 mm EDTA + 500 mm NaCl (ph 7.0) Combine 18.61 g EDTA and 29.22 g NaCl in a 1-L volumetric flask containing about 500 ml of degassed deionized water. Bring the volume to about 950 ml and adjust the ph to 7.0 with 1 M NaOH. Separation of an Intact Monoclonal Antibody and Fractionation of Monoclonal Antibody Papain Digest Fragments Using Immobilized Metal Affinity Chromatography (IMAC)

Note: Mobile phase D is not required if the column is converted to the copper form without exposure of the pump to copper metal (see the ProPac IMAC-10 column manual for further details). Loading the ProPac IMAC-10 Column in the Copper Form Option 1: Loading with an empty column body To convert the IMAC column to the copper form without exposing the system to copper metal, fill a 9 x 50-mm (P/N 063710) empty column body with mobile phase C and place it between the pump and the IMAC column. Push the metal through the IMAC column using mobile phase B at 1 ml/min for at least 10 column volumes followed by rinsing with 5 column volumes of mobile phase A. Option 2: Loading with the analytical pump Although it is strongly recommended that an empty column body be used to load the column with copper, the analytical pump may be used as an alternative. Flush the lines with DI water prior to rinsing with metal solution. Begin by charging the column with three column volumes of mobile phase C. After charging the column, remove the column and rinse the lines with DI water followed by mobile phase D. Warning: do not pump 50 mm EDTA through the column as this will strip the column of the Cu 2+ metal. Reinstall the column and rinse the column with 30 column volumes of mobile phase B. Equilibrate the column with 5 column volumes of mobile phase A. Once the column is loaded with copper, do not reload the column with a different metal. Stage 2: separation of the intact (Method 1) and papain digested (Method 2) mabs with the propac Imac-10 column (copper form) Method 1: Separation of Intact IgG1 MAb Sample Preparation 5 mg/ml Intact IgG1 MAb MAbs are often stored in highly concentrated solutions (e.g. 50 mg/ml). Dilute the concentrated antibody to 5 mg/ml with deionized water. Mobile Phases 1 and 2 Required for Separation of the Intact IgG1 MAb The following two mobile phases are required for the separation of the intact IgG1 MAb with the ProPac IMAC-10 column in the copper form: Mobile Phase 1: 20 mm MES + 500 mm NaCl + 1 mm imidazole Mobile Phase 2: 20 mm MES + 500 mm NaCl + Preparation of Mobile Phases 1 and 2 Mobile Phase 1: 20 mm MES + 500 mm NaCl + 1 mm imidazole Combine 3.904 g MES, 29.22 g NaCl, and 0.0681 g imidazole in a 1-L volumetric flask containing about 500 ml of degassed deionized water. Bring the volume to about 975 ml with deionized water, stir to dissolve, and adjust the ph to 5.5 with 1 M NaOH. Mobile Phase 2: 20 mm MES + 500 mm NaCl + Combine 3.904 g MES, 29.22 g NaCl, and 6.808 g imidazole in a 1-L volumetric flask containing about 500 ml of degassed deionized water. Bring the volume to about 975 ml with deionized water, stir to dissolve, and adjust the ph to 5.5 with 1 M NaOH. Experimental Conditions Column: ProPac IMAC-10, 4 x 250 mm (P/N 063278) Mobile Phase 1: 20 mm MES, 500 mm NaCl, 1 mm imidazole Mobile Phase 2: 20 mm MES, 500 mm NaCl, Gradient: 4 50 min, 0 100% B Injection: 10 µl Detection: Absorbance, 280 nm Procedure Separation of intact IgG1 MAb Time A (%) B (%) Comments -5.00 100 0 Equilibration 0.00 100 0 Injection 4.00 100 0 50.00 0 100 End gradient 60.00 0 100 Application Note 177 3

Method 2: Separation of Papain Digested IgG1 MAb Reagent Preparation 200 mm Sodium Phosphate, Dibasic Dissolve 14.196 g anhydrous dibasic sodium phosphate (Na 2 HPO 4 ) in 500 ml of deionized water. 200 mm Sodium Phosphate, Monobasic Dissolve 13.799 g monobasic sodium phosphate (NaH 2 PO 4 H 2 O) in 500 ml of deionized water. 25 mm Sodium Phosphate Buffer, ph 7.6 Combine 108.8 ml of 200 mm dibasic sodium phosphate, 16.2 ml of 200 mm monobasic sodium phosphate, and 875 ml of deionized water. Verify that the ph is 7.6. 20 mm L-Cysteine Dissolve 48.46 mg L-cysteine in 20 ml of phosphate buffer. Sample Preparation Papain Digested IgG1 MAb Perform a papain digest of the intact IgG1 MAb by adding the components in the following order: (1) 70 µl phosphate buffer, (2) 10 µl of 50 mg/ml intact IgG1 MAb, (3) 10 µl L-cysteine, and (4) 10 µl of 0.50 mg/ml papain. The final MAb to papain concentration should be 100:1. Heat the digest at 37 C in a heating block or bath for 140 min. Store the unused digest at 40 C. Mobile Phases 3 and 4 Required for Separation of the Papain Digested MAb The following two mobile phases are required for the separation of the papain digested MAb with the ProPac IMAC-10 column in the copper form: Mobile Phase 3: 20 mm MES + 200 mm NaCl Mobile Phase 4: 20 mm MES + 200 mm NaCl + Preparation of Mobile Phases 3 and 4 Method 2: Separation of Papain Digested MAb with the ProPac IMAC-10 Column Mobile Phase 3: 20 mm MES + 200 mm NaCl Combine 3.904 g MES and 11.688 g NaCl in a 1-L volumetric flask containing about 500 ml of degassed deionized water. Bring the volume to about 975 ml with deionized water, stir to dissolve, adjust the ph to 5.5 with 1 M NaOH, and then fill to a final volume of 1 L. Mobile Phase 4: 20 mm MES + 200 mm NaCl + Combine 3.904 g MES, 11.688 g NaCl, and 6.808 g imidazole in a 1-L volumetric flask containing about 500 ml of degassed deionized water. Bring the volume to about 975 ml with deionized water, stir to dissolve, adjust the ph to 5.5 with 1 M NaOH, and then fill to a final volume of 1 L. Experimental Conditions Column: ProPac IMAC-10, 4 x 250 mm (P/N 063278) Mobile Phase 3: 20 mm MES, 200 mm NaCl Mobile Phase 4: 20 mm MES, 200 mm NaCl, Gradient: 1 20 min, 1 100% B Injection: 100 µl Detection: Absorbance, 280 nm Procedure Time A (%) B (%) Comments -2.00 99 1.00 Equilibration 0.00 99 1.00 Injection 1.00 99 1.00 20.00 0 100 End gradient 40.00 0 100 4 Separation of an Intact Monoclonal Antibody and Fractionation of Monoclonal Antibody Papain Digest Fragments Using Immobilized Metal Affinity Chromatography (IMAC)

Stage 3: Separation and Analysis of Intact and Papain Digested MAb fragments on the ProPac WCX-10 Column Mobile Phases 5 and 6 Required for the Separation and Analysis of Intact and Papain Digested MAb Fragments The following two mobile phases are required for the separation and analysis of intact and papain digested MAb fragments on the ProPac WCX-10 Column: Mobile Phase 5: 20 mm MES + 40 mm NaCl + Mobile Phase 6: 20 mm MES + 180 mm NaCl + 0.060 AU Column: ProPac IMAC-10, 4 250 mm Eluent: A. 20 mm MES, 500 mm NaCl, 1 mm imidazole, ph 5.5 B. 20 mm MES, 500 mm NaCl, 100 mm imidazole, ph 5.5 Gradient: 0 100% B from 4 50 min Temperature: 25 C Inj. Volume: 10 µl Detection: UV absorbance at 280 nm Peaks: 1. Intact MAb 5 mg/ml 1 Preparation of Mobile Phases 5 and 6 Mobile Phase 5: 20 mm MES + 40 mm NaCl + Combine 3.904 g MES, 2.338 g NaCl, and 0.3722 g EDTA in a 1-L volumetric flask containing about 800 ml of degassed deionized water. Because EDTA dissolves very slowly, it is helpful to add 10 20 drops of 1 M NaOH to the mixture prior to stirring. Check the ph often and add more base as necessary. Bring the solution to a volume of approximately 950 ml, adjust to a final ph of 5.5 with 1 M NaOH, and bring the total volume to 1 L. Mobile Phase 6: 20 mm MES + 180 mm NaCl + Combine 3.904 g MES, 10.519 g NaCl, and 0.3722 g EDTA in a 1-L volumetric flask. Follow the same procedure for adjusting the ph as described for mobile phase 5. Experimental Conditions Column: ProPac WCX-10, 4 x 250 mm (P/N 054993) Mobile Phase 5: 20 mm MES, 40 mm NaCl, Mobile Phase 6: 20 mm MES, 180 mm NaCl, Gradient: 1 35 min, 0 100% B Flow Rate: 1 ml/min Injection: 10-15 µl Detection: Absorbance, 280 nm -0.040 0 5 10 15 20 25 30 35 40 Minutes 23258 Figure 1. Separation of pure intact MAb on the ProPac IMAC-10 column. 0.800 AU -0.001 0 Column: ProPac IMAC-10, 4 250 mm Eluent: A. 20 mm MES, 200 mm NaCl, ph 5.5 B. 20 mm MES, 200 mm NaCl, 100 mm imidazole, ph 5.5 Gradient: 1 100% B from 1 20 min Temperature: 25 C Inj. Volume: 100 µl Detection: UV absorbance at 280 nm Peaks: 1. Fab 2. Fc Fab Fraction 1 Fc Fraction 2 5 10 15 20 25 30 35 40 Minutes 23259 Figure 2. Separation of papain digested MAb fragments on the ProPac IMAC-10 column. Application Note 177

Column: Eluent: Gradient: AU 0 A B C Figure 3. Separation of (A) total papain digest on the WCX-10 column, (B) IMAC-10 retained fraction and (C) IMAC-10 flowthrough fraction on the WCX-10 column. Procedure ProPac WCX, 4 250 mm A. 20 mm MES, 40 mm NaCl, 1 mm EDTA, ph 5.5 B. 20 mm MES, 180 mm NaCl, 1 mm EDTA, ph 5.5 0 100% B from 1 35 min Fc + K truncation variants Fc + K truncation variants Time A (%) B (%) Comments -5.00 100 0 Equilibration 0.00 100 0 Injection 1.00 100 0 35.00 0 100 End gradient 40.00 0 100 RESULTS AND DISCUSSION Temperature: 25 C Flow Rate: 1 ml/min Inj. Volume: 100 µl Detection: UV absorbance at 280 nm Fab F ab from ProPac IMAC-10 10 20 30 40 Minutes 23260 The performance of IMAC-10 column was assessed for its ability to separate intact and papain digested monoclonal IgG1 fragments. Figure 1 shows a chromatogram of an intact MAb separated on the ProPac IMAC-10 column. The humanized MAb was then digested with papain at 37 C for 140 min to yield Fc and Fab fragments. Papain is a non-specific thiol protease that cleaves IgG antibodies at the hinge region of the Y-shaped molecule into three fragments of similar size: Fab after digestion with papain F c from ProPac IMAC-10 two Fab fragments and one Fc fragment. 3 Figure 2 shows a separation of the papain digest on the ProPac IMAC- 10 column. Only the Fc fragment was retained on the column due to the interaction of the surface exposed histidine residues on the Fc fragment with the immobilized Cu 2+ on the IMAC resin. Figure 3A shows a separation of papain digested IgG1 MAb fragments on the ProPac WCX-10 column. The Fc fragments elute in the order of increasing lysine content of the truncation variants followed by the separation of the Fab fragment using a NaCl gradient (40 180 mm over 35 min) at ph 5.5. The peak identification shown is supported by published data. 4 The presence of the lysine truncation peaks of the Fc fragment was previously verified by performing a carboxypeptidase digest. 5 To confirm that the non-retained and retained peaks on the IMAC were the Fab and Fc fragments, respectively each peak was collected and reinjected on the WCX column. Figure 3B and 3C show the separation of each ProPac IMAC fraction on the ProPac WCX column. This separation confirms that the Fab elutes in the flow-through fraction and the Fc elutes in the retained fraction A commercially available HPLC protein A column was evaluated and compared against the ProPac IMAC- 10 column. The papain digest fragments were injected on the Protein A column and the Fab and Fc fragments were also collected and reinjected on the WCX columns. Some degradation of the Fab fragment was observed due to the harsh elution buffer conditions (100 mm sodium citrate, ph 3.3) required for the protein A separation. Correlation of the peaks confirmed that the ProPac IMAC-10 separates Fab and Fc fragments. CONCLUSION The results shown in this application note demonstrate that the ProPac IMAC-10 separates papain digested IgG1 MAb fragments. The IMAC column uses mild eluent conditions and therefore minimizes the potential for sample degradation. The ProPac IMAC-10 column does not contain any biological materials that can leach off the column and contaminate the target protein. Separation of an Intact Monoclonal Antibody and Fractionation of Monoclonal Antibody Papain Digest Fragments Using Immobilized Metal Affinity Chromatography (IMAC)

REFERENCES 1. Josic, D., Lim, Y. P. Food Tech. Biotechnol. 2001, 39(3), 215. 2. Todorova-Balvay, D., Pitiot, O., Bourhim, M., Srikrishnan, T., Vijayalakshmi, M. J. Chromatogr. B, 2004, 808, 57. 3. Weitzhandler, M., Farnan, D., Avdalovic, N. Am. Biotech. Lab. September 2000, 36. 4. Moorhouse, K. G., Nashabeh, W., Deveney, J., Bjork, N. S., Mulkerrin, M. G., Ryskamp, T. J. Pharm. Biomed. Anal. 1997, 16, 593. 5. Analysis of Monoclonal Antibody Heterogeneity by Cation-Exchange Chromatography: Separation of C-Terminal Lysine Variants. Application Note 127, Dionex Corporation, Sunnyvale, CA. Chromeleon and ProPac are registered trademarks of Dionex Corporation. Passion. Power. Productivity. Dionex Corporation North America Europe Asia Pacific 1228 Titan Way P.O. Box 3603 U.S. (847) 295-7500 Canada (905) 844-9650 Austria (43) 1 616 51 25 Belgium (32) 3 353 4294 Denmark (45) 36 36 90 90 France (33) 1 39 30 01 10 Germany (49) 6126 991 0 Italy (39) 02 51 62 1267 Sunnyvale, CA The Netherlands (31) 20 683 9768 Switzerland (41) 62 205 9966 South America 94088-3603 U.K. and Ireland (44) 1276 691722 Brazil (55) 11 3731 5140 (408) 737-0700 www.dionex.com Australia (61) 2 9420 5233 China (852) 2428 3282 India (91) 22 28475235 Japan (81) 6 6885 1213 Korea (82) 2 2653 2580 Singapore (65) 6289 1190 LPN 1840 12/06 Application Note 2006 177 Dionex Corporation 7