Bypass level indicator With magnetic display Model BNA



Similar documents
Compact pressure switch Flameproof enclosure Ex d Model PCA

Plastic tube flowmeters Series PT/PS

Threaded Resistance Thermometers Model TR10-D, Miniature Design

OPTIMASS 6000 Technical Datasheet

Bimetal thermometer Model 52, industrial series

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Colima Visco and Colima Viscorol Magnetic Level Indicators

SITRANS F flowmeters SITRANS F M

Hose and Tube Fittings Series 1-3

Pressure transmitter For general industrial applications Model A-10

SISTO-16TWA/HWA/DLU. Type Series Booklet

Fluxi 2000/TZ Turbine Gas Meter

Appendix. Cross Reference BFT. Type Code. Ordering Example. Replaced Type Type Description. ZVS BFT-H Cylindrical float, stainless steel

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

RUBBER SLEEVE KNIFE GATE VALVE

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

How To Use A Flowmeter

Self-operated Temperature Regulators Temperature Regulator Type 1u

kymanual or Automatic - it s your Choice

Series 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve

Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version

Turbine Flow Sensor Series VTR

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

API Flanged Safety Relief Valves Series 526 CATALOG

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology

OPTIMASS 1400 Technical Datasheet

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

High pressure reactors Where are your limits?

Flow switches Series AD/VH

Kompressoren. Adsorption Dryer AD

Adsorption air dryers ADS 1 215

Duplex Filters 40 FLDK 0008(C)-0120(C)

Differential Pressure Transmitter Model DPT-10

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

MINEX -S. Magnetic coupling. You will find continuously updated data in our online catalogue at

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

VALVE TECHNOLOGY ONE STEP AHEAD.

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

Type 3353 Angle Seat Valve

VALVE TECHNOLOGY ONE STEP AHEAD.

Safety at a high level!

Workshop Compressors CLASSIC Series

Micro Motion Model D and DL Coriolis Flow and Density Meters

Hand-held thermometer Model CTH7000

KSR Magnetic Level Indicators / Gauges

Operating Instructions for Plastic Flow Meter. Model: KSK

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

AIR AND DIRT SEPARATORS. Flamco FLEXVENT. Air and dirt separators FLAMCOVENT FLAMCOVENT CLEAN FLEXAIR FLAMCO CLEAN FLAMCO A-S.

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Stainless steel process fittings

Order Code for GEA Tuchenhagen VESTA Sterile Valves. Type H_A 2/2 Way Seat Valve

solarplus solar systems general features

FLEXWELL Safety Pipe. Pipe systems for installations Technical details

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

VAD Variable Area Desuperheaters

Thermometer in stainless steel with capillary and switch contacts

3M Housings DS Series

INDUSTRIAL CONTROL INSTRUMENTS FOR PROCESS AUTOMATION TOR REED SWITCH

Backflush filter R8-30W

MFP14, MFP14S and MFP14SS Automatic Pumps

Screw Plug Immersion Heaters

Grooved gaskets. Types of gaskets

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Variable V Area Flowmeter Rotameter The Original

German engineering under high pressure

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a

Flamco. Flexcon M. Installation and operating instructions Flamco

CRN A-F-G-E-HQQE 3x400D 50 HZ

Digital inductive conductivity transmitter

VAD. Variable Area Desuperheaters

DOUBLE GATE KNIFE GATE VALVE

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

Terminal Boxes Series 8146

1. Geo Vertical 2. Geo Horizontal

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

GYROLOK to Tube Union

Morgue refrigeration unit

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

MEMBRANE VACUUM MINI PUMPS

Assisted lift operated 2/2-way solenoid valves Type EV250B

How To Use A Corona Mdi 110

Full Technical Catalog For Closed-loop Sampling System

Solenoid valves 2/2-way direct-operated Type EV210A

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Spiroflex spiral-wound gaskets

2- and 3-port valves with flanged connections, PN 10

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Control- and feedback head for integrated mounting on Robolux valves Type 2036

The Unique Accelabar Flow Meter

Operating Instructions

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Machine nozzle with needle shut-off type HP pneumatically or hydraulically controlled

Scraper Passage Indicator. Electrical Indicator. Features

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Solenoid valves Type EVU

Transcription:

Level measurement Bypass level indicator With magnetic display Model BNA WIKA data sheet LM 10.01 Applications Continuous level indication without power supply Indication of the level proportional to height Individual design and corrosion resistant materials make the products suitable for a broad range of applications Chemical, petrochemical industry, oil and natural gas extraction (on- and offshore), shipbuilding, machine building, power generating equipment, power plants Process water and drinking water treatment, food industry, pharmaceutical industry Special features Process- and system-specific production Operating limits: - Operating temperature: T = -196... +450 C - Operating pressure: P = vacuum to 400 bar - Limit density: ρ 340 kg/m 3 Wide variety of different process connections and materials Mounting of level sensors and magnetic switches possible as an option Explosion-protected versions Description The bypass level indicator model BNA consists of a bypass chamber, which, as a communicating tube, is connected laterally to a vessel via at least 2 process connections (flanged, threaded or welded). Through this type of arrangement, the level in the bypass chamber corresponds to the level in the vessel. The float with a built-in permanent magnetic system, which is mounted within the bypass chamber, transmits the liquid level, contact-free, to the magnetic display mounted to the outside of the bypass chamber. In this are fitted, at 10 mm intervals, two-coloured plastic rollers or stainless steel flaps with bar magnets. Bypass level indicator, model BNA with level sensor and magnetic switch Through the magnetic field of the permanent magnetic system in the float, the display elements, through the wall of the bypass chamber, are turned through 180. For an increasing level from white to red; for a falling level from red to white. Thus the bypass level indicator clearly displays the level of a vessel without power supply. Page 1 of 16 Data sheets showing similar products and accessories: ; model BFT; see data sheet LM 10.02 Magnetic display; model BMD; see data sheet LM 10.03 Reed sensor; model BLR; see data sheet LM 10.04 Magnetostrictive sensor; model BLM; see data Magnetic switch; model BGU; see data sheet LM 10.06

Further special features Illustration of the principle Simple, robust and solid design, long service life Bypass chamber and float from stainless steel 1.4571, 1.4404 or special materials Pressure- and gas-tight separation between measuring and display chamber Measuring and indicating of the level of aggressive, combustible, toxic, hot and contaminated media Functioning of the magnetic display guaranteed even in the case of power failures By using a variety of corrosion-resistant materials, applicable for virtually all industrial applications Continuous measurement of levels, independent of physical and chemical changes of the media such as: Foaming, conductivity, dielectric constant, vapours, bubble formation, boiling effects Interface-layer level measurement from density 100 kg/m 3 Special versions: Food compliant, coatings, liquid gas, heating jacket Bypass chamber (with magnetic system) Magnetic display Connection housing (only with option magnetic switch or level sensor) Design and operating principle In a communicating bypass chamber mounted to the side of a vessel a float moves with the level of the medium to be measured. The magnetic field of the radial-symmetric magnetic system positioned in the float activates the magnetic display attached to the outside of the bypass chamber as well as the switching and measuring elements. Magnetic system The magnetic system is assembled from a pole disc and various magnets. These can be individually adapted to the different chamber dimensions and for temperatures up to 450 C. Field lines Magnets Pole disc Page 2 of 16

Model overview Bypass level indicator Approval Material Max. without GL DNV in Ex c Ex c, Ex c, GL DNV ABS pressure bar Compact version, model BNA-C Standard version, model BNA-S High-pressure version, model BNA-H Plastic version, model BNA-P DUPlus version, standard, model BNA-SD DUPlus version, high pressure, model BNA-HD Liquid gas/koplus version, model BNA-L Special materials, model BNA-X Heating jacket version, model BNA-J Medium temperature in C x x x x x x Stainless steel 1.4571 (316Ti) 40-196... +150 x x x x x x x Stainless steel 1.4571 (316Ti), 1.4404 (316L), 1.4401/1.4404 (316/316L) 64-196... +450 x x x x x x Stainless steel 1.4571 (316Ti), 400-196... +450 1.4404 (316L) x PP, PVDF 6-10... +100 x x Stainless steel 1.4571 (316Ti), 1.4404 (316L), 1.4401/1.4404 (316/316L) x x Stainless steel 1.4571 (316Ti), 1.4404 (316L), 1.4401/1.4404 (316/316L) x x Stainless steel 1.4571 (316Ti), 1.4404 (316L) x x Stainless steel 6Mo 1.4547 (UNS S31254) x Stainless steel 1.4571 (316Ti) with internal coating E-CTFE, ETFE or PTFE 64-196... +450 160-196... +450 25-60... +300 250-196... +450 16 depending on the medium x x x x x x Titanium 3.7035 64-196... +450 x x x x x x Hastelloy C276 (2.4819) 160-196... +450 x x x x Stainless steel 1.4571 (316Ti), 64-60... +450 1.4404 (316L) Ex approvals Explosion protection Ignition protection type ATEX Ex c BNA-S, BNA-H, BNA-C, BNA-SD, BNA-HD, BNA-X, BNA-J Ex c + GL BNA-S, BNA-H, BNA-C, BNA-X, BNA-J Ex c + DNV BNA-S, BNA-H, BNA-C, BNA-X Model Zone Approval number Zone 0/1, gas KEMA 02 ATEX 2106 X ll 1/2 G c T1... T6 Zone 0/1, gas KEMA 02 ATEX 2106 X ll 1/2 G c T1... T6 + GL - 35 949-87 Zone 0/1, gas KEMA 02 ATEX 2106 X ll 1/2 G c T1... T6 + DNV - A-11451 Type approval Approval Model Approval number GL BNA-S, BNA-H, GL - 35 949-87 HH BNA-C, BNA-X, BNA-J DNV BNA-S, BNA-H, DNV A-11451 BNA-C, BNA-X ABS BNA-S ABS 07-HG218425-1-PDA GOST-R all 0959333 Further approvals on request Detailed information on floats, magnetic displays, sensors (reed chains and magnetostrictive) and magnetic switches can be found in the following data sheets: ; model BFT; see data sheet LM 10.02 Magnetic display; model BMD; see data sheet LM 10.03 Reed sensor; model BLR; see data sheet LM 10.04 Magnetostrictive sensor; model BLM; see data sheet LM 10.05 Magnetic switch; model BGU; see data sheet LM 10.06 Page 3 of 16

Bypass level indicator, compact version, model BNA-C Bypass chamber from stainless steel ~25 U... M... 70 X M = centre-to-centre distance of the process connections U = float length (min. 150 mm) X = according to process connection Bypass chamber Ø 42.2 x 2 mm, max. 40 bar Flat top, flange or threaded connection or threaded connection Flange EN 1092-1, DN 10 - DN 50, PN 6 - PN 40 Flange DIN, DN 10 - DN 50, PN 6 - PN 40 Flange ANSI B 16.5, 1/2" - 2,5", class 150 - class 300 Weld stub 1/2" - 1" Centre-to-centre Min. 150 mm to max. 5,000 mm distance Material Stainless steel 1.4571 (316Ti) Nominal pressure Max. 40 bar Temperature range -196... +150 C Magnetic display Level sensor Magnetic switches Cylindrical float, model BFT-H32, see data sheet LM 10.02 Magnetic display; model BMD-S; see data sheet LM 10.03 Reed sensor, model BLR, see data sheet LM 10.04 Magnetic switch, model BGU, see data sheet LM 10.06 Ex c, GL, DNV, GOST-R Page 4 of 16

Bypass level indicator, standard version, model BNA-S Bypass chamber from stainless steel 90 ~35 U M... X M = centre-to-centre distance of the process connections U = float length (min. 200 mm) X = according to process connection Bypass chamber Ø 60.3 x 2 mm, max. 40 bar Ø 60.3 x 2.77 mm, max. 64 bar Flat top or flange connection Flange EN 1092-1, DN 10 - DN 100, PN 6 - PN 63 Flange DIN, DN 10 - DN 100, PN 6 - PN 64 Flange ANSI B 16.5, 1/2" - 4", class 150 - class 600 Weld stub 1/2" - 1" Centre-to-centre distance Min. 150 mm to max. 6,000 mm (larger distances on request) Material Stainless steel 1.4571 (316Ti), 1.4404 (316L), 1.4401/1.4404 (316/316L) Nominal pressure Max. 64 bar Temperature range -196... +450 C Cylindrical float, model BFT-H or corrugated float, model BFT-S, see data sheet LM 10.02 Magnetic display Standard version, model BMD-S: < 200 C High-temperature version, model BMD-F: > 200 C, see data sheet LM 10.03 Level sensor Reed sensor, model BLR, see data sheet LM 10.04 Magnetic switches Magnetic switch, model BGU, see data sheet LM 10.06 Ex c, GL, DNV, ABS, GOST-R Page 5 of 16

Bypass level indicator, high-pressure version, model BNA-H Bypass chamber from stainless steel ~51 U M... 100 ~63 150 M = centre-to-centre distance of the process connections U = float length (min. 220 mm) Bypass chamber Stainless steel 1.4571: Ø 60.3 x 3.91 mm, max. 160 bar Ø 76.1 x 5 mm, max. 160 bar Ø 71 x 7.5 mm, max. 250 bar Ø 76.1 x 10 mm, max. 420 bar Stainless steel 1.4404: Ø 60.3 x 3.91 mm, max. 100 bar Ø 60.3 x 5.54 mm, max. 150 bar Ø 73 x 7.01 mm, max. 150 bar Flat top or flange connection Flange EN 1092-1, DN 10 - DN 100, PN 63 - PN 400 Flange DIN, DN 10 - DN 100, PN 64 - PN 400 Flange ANSI B 16.5, 1/2" - 4", class 600 - class 2,500 Weld stub 1/2" - 1" Centre-to-centre distance Min. 150 mm to max. 6,000 mm (larger distances on request) Material Stainless steel 1.4571 (Ø 60.3 x 3.91 mm, Ø 76.1 x 5 mm, Ø 71 x 7.5 mm, Ø 76.1 x 10 mm) or stainless steel 1.4404 (Ø 60.3 x 3.91 mm, Ø 60.3 x 5.54 mm, Ø 73 x 7.01 mm) Nominal pressure Max. 400 bar Temperature range -196... +450 C Cylindrical float, model BFT-H, ball-segment float, model BFT-K or foam float, model BFT-F, see data sheet LM 10.02 Magnetic display Standard version, model BMD-S: < 200 C High-temperature version, model BMD-F: > 200 C, see data sheet LM 10.03 Level sensor Reed sensor, model BLR, see data sheet LM 10.04 Magnetic switches Magnetic switch, model BGU, see data sheet LM 10.06 Ex c, GL, DNV, GOST-R Page 6 of 16

Bypass level indicator, plastic version, model BNA-P Bypass chamber and float from PVDF or PP M = centre-to-centre distance of the process connections U = float length (min. 155 mm) Bypass chamber Ø 63 x 3 mm, max. 6 bar Welding cap, threaded connection Threaded connection Flange EN 1092-1, DN 15 - DN 50, PN 16 Flange DIN, DN 15 - DN 50, PN 16 Flange ANSI B 16.5, 1/2" - 2", class 150 Weld stub 1/2" - 1" Centre-to-centre distance Min. 200 mm to max. 4,000 mm (larger distances on request) Material PVDF or PP Nominal pressure Max. 6 bar Temperature range PVDF: -10 +100 C PP: -10 +80 C Plastic float, model BFT-P, see data sheet LM 10.02 Magnetic display Standard version, model BMD-S, see data sheet LM 10.03 Level sensor Reed sensor, model BLR, see data sheet LM 10.04 Magnetic switches Magnetic switch, model BGU, see data sheet LM 10.06 - Page 7 of 16

Bypass level indicator, DUPlus version, standard, model BNA-SD Bypass chamber from stainless steel Bypass chamber Ø 60.3 x 2 mm, max. 40 bar Ø 60.3 x 2.77 mm, max. 64 bar Flat top or flange connection Flange DIN, DN 10 - DN 100, PN 6 - PN 64 Flange ANSI B 16.5, 1/2" - 4", class 150 - class 600 Weld stub 1/2" - 1" External sensor connection Flange EN 1092-1, DN 50, PN 6 - PN 64 Flange DIN, DN 50, PN 6 - PN 64 Flange ANSI B 16.5, 2" class 150 - class 600 Female thread G/NPT 3/4" - 2" Centre-to-centre distance Min. 150 mm to max. 6,000 mm (larger distances on request) Material Stainless steel 1.4571, 1.4404 or 1.4401/1.4404 Nominal pressure Max. 64 bar Temperature range -196... +450 C Cylindrical float, model BFT-H or corrugated float, model BFT-S, see data sheet LM 10.02 Magnetic display Standard version, model BMD-S: < 200 C High-temperature version, model BMD-F: > 200 C, see data sheet LM 10.03 Level sensor Reed sensor, model BLR, see data sheet LM 10.04 Guided wave radar, model GTR, see data sheet LM 20.05 Magnetic switches Magnetic switch, model BGU, see data sheet LM 10.06 Ex c, GOST-R Page 8 of 16

Bypass level indicator, DUPlus version, high pressure, model BNA-HD Bypass chamber from stainless steel Bypass chamber Ø 60.3 x 3.91 mm, max. 160 bar Flat top or flange connection Flange DIN, DN 10 - DN 100, PN 64 - PN 160 Flange ANSI B 16.5, 1/2" - 4", class 600 - class 1,500 Weld stub 1/2" - 1" External sensor connection Flange EN 1092-1, DN 50, PN 6 - PN 160 Flange DIN, DN 50, PN 6 - PN 160 Flange ANSI B 16.5, 2" class 150 - class 1,500 Female thread G/NPT 3/4" - 2" Centre-to-centre distance Min. 150 mm to max. 6,000 mm (larger distances on request) Material Stainless steel 1.4571, 1.4404 or 1.4401/1.4404 Nominal pressure Max. 160 bar Temperature range -196... +450 C Cylindrical float, model BFT-H, corrugated float, model BFT-S, ball-segment float, model BFT-K or foam float, model BFT-F, see data sheet LM 10.02 Magnetic display Standard version, model BMD-S: < 200 C High-temperature version, model BMD-F: > 200 C, see data sheet LM 10.03 Level sensor Reed sensor, model BLR, see data sheet LM 10.04 Guided wave radar, model GTR, see data sheet LM 20.05 Magnetic switches Magnetic switch, model BGU, see data sheet LM 10.06 Ex c, GOST-R Page 9 of 16

Bypass level indicator, liquid gas/koplus version, model BNA-L Bypass chamber from stainless steel A A A - A ~42 ~42 U M... 80 150 M = centre-to-centre distance of the process connections U = float length (min. 220 mm) Bypass chamber Ø 88.9 x 2 mm, max. 25 bar Ø 88.9 x 2.9 mm, max. 40 bar Flange EN 1092-1, DN 10 - DN 100, PN 6 - PN 63 Flange DIN, DN 10 - DN 100, PN 6 - PN 64 Flange ANSI B 16.5, 1/2" - 4", class 150 - class 600 Weld stub 1/2" - 1" Centre-to-centre distance Min. 150 mm to max. 6,000 mm (larger distances on request) Material Stainless steel 1.4571 (316Ti) (Ø 88.9 x 2 mm, Ø 88.9 x 2.9 mm) Stainless steel 1.4404 (316L) (Ø 88.9 x 2 mm) Nominal pressure Max. 40 bar Temperature range -60... +300 C Cylindrical float, model BFT-H, see data sheet LM 10.02 Magnetic display Standard version, model BMD-S: < 200 C High-temperature version, model BMD-F: > 200 C, see data sheet LM 10.03 Level sensor Reed sensor, model BLR, see data sheet LM 10.04 Guided wave radar, model GTR (for KOPlus version), see data sheet LM 20.05 Magnetic switches Magnetic switch, model BGU, see data sheet LM 10.06 Ex c, GOST-R KOPlus version Page 10 of 16

Bypass level indicator, special materials, model BNA-X Bypass chamber from Titanium, Hastelloy or stainless steel 6Mo ~51 U M... 100 ~63 150 M = centre-to-centre distance of the process connections U = float length (min. 220 mm) Material 1) Titanium 3.7035 Hastelloy C276 Stainless steel 6Mo 1.4547 (UNS S31254) Bypass chamber Process connections (2 x lateral, options see page 15) Ø 60.3 x 2 mm, max. 40 bar Ø 60.3 x 2.77 mm, max. 64 bar Flat top or flange connection Flange EN 1092-1, DN 10 - DN 100, PN 6 - PN 63 Flange DIN, DN 10 - DN 100, PN 6 - PN 64 Flange ANSI B 16.5, 1/2" - 4", class 150 - class 600 Ø 60.3 x 2.77 mm, max. 64 bar Ø 60.3 x 3.91 mm, max. 160 bar Flange EN 1092-1, DN 10 - DN 100, PN 6 - PN 400 Flange DIN, DN 10 - DN 100, PN 6 - PN 400 Flange ANSI B 16.5, 1/2" - 4", class 150 - class 2,500 Ø 60.3 x 2.77 mm, max. 64 bar Ø 60.3 x 3.91 mm, max. 160 bar Ø 60.3 x 5.54 mm, max. 250 bar Flange EN 1092-1, DN 10 - DN 100, PN 63 - PN 400 Flange DIN, DN 10 - DN 100, PN 64 - PN 400 Flange ANSI B 16.5, 1/2" - 4", class 600 - class 2,500 Centre-to-centre Min. 150 mm to max. 6,000 mm (larger distances on request) distance Nominal pressure Max. 64 bar Max. 160 bar Max. 250 bar Temperature range -196... +450 C Cylindrical float, model BFT-H or corrugated float, model BFT-S (titanium 3.7035 and stainless steel 1.4547), see data sheet LM 10.02 Magnetic display Standard version, model BMD-S: < 200 C High-temperature version, model BMD-F: > 200 C, see data sheet LM 10.03 Level sensor Reed sensor, model BLR, see data sheet LM 10.04 Magnetic switches Magnetic switch, model BGU, see data sheet LM 10.06 Ex c, GL, DNV, GOST-R Ex c, GL, DNV, GOST-R Ex c, GOST-R 1) Other materials on request Page 11 of 16

Bypass level indicator, special materials, model BNA-X Bypass chamber from stainless steel with internal coating E-CTFE, ETFE or PTFE ~50 U =... M =... 130/ 150 150 ~35 150 Material Bypass chamber Stainless steel 1.4571 with internal coating E-CTFE ETFE PTFE Ø 64 x 2 mm, max. 16 bar Ø 70 x 2 mm, max. 16 bar Ø 70 x 2 mm, max. 10 bar Flange EN 1092-1, DN 10 - DN 50, PN 6 - PN 16 Flange DIN, DN 10 - DN 50, PN 6 - PN 16 Flange ANSI B 16.5, 1/2" - 4", class 150 - class 300 Centre-to-centre distance Min. 150 mm to max.... mm (overall pipe length max. 2,500 mm) With overall pipe length > 2,500 mm: Bypass chamber separated by flange connection Nominal pressure Max. 16 bar Max. 16 bar Max. 10 bar Temperature range depending on the medium Cylindrical float, model BFT-H, see data sheet LM 10.02 Magnetic display Standard version, model BMD-S, see data sheet LM 10.03 Level sensor Reed sensor, model BLR, see data sheet LM 10.04 Magnetic switches Magnetic switch, model BGU, see data sheet LM 10.06 GOST-R M = centre-to-centre distance of the process connections U = float length (min. 200 mm) Page 12 of 16

Bypass level indicator, heating jacket version, model BNA-J Bypass chamber and heating jacket pipe from stainless steel Process connection Heating jacket connection 12.00 9.00 3.00 6.00 80 ~42 U M... 80 150 M = centre-to-centre distance of the process connections U = float length (min. 220 mm) Bypass chamber Heating jacket pipe Ø 60.3 x 2 mm, max. 40 bar Ø 60.3 x 2.77 mm, max. 64 bar Ø 70 x 2 mm Flat top Flange EN 1092-1, DN 10 - DN 100, PN 6 - PN 100 Flange DIN, DN 10 - DN 100, PN 6 - PN 100 Flange ANSI B 16.5, 1/2" - 4", class 150 - class 600 Weld stub 1/2" - 1" Heating jacket connection Flange EN 1092-1, DN 10 - DN 25, PN 6 - PN 40 Flange DIN, DN 10 - DN 25, PN 6 - PN 40 Flange ANSI B 16.5, 1/2" - 4", class 150 - class 300 Centre-to-centre distance Min. 150 mm to max. 6,000 mm (larger distances on request) Material Stainless steel 1.4571 with bypass chamber Ø 60.3 x 2 mm (standard version) Stainless steel 1.4404 with bypass chamber Ø 60.3 x 2.77 mm on request Nominal pressure Max. 64 bar Temperature range -60... +450 C Cylindrical float, model BFT-H, see data sheet LM 10.02 Magnetic display Standard version, model BMD-S: < 200 C High-temperature version, model BMD-F: > 200 C, see data sheet LM 10.03 Level sensor Reed sensor, model BLR, see data sheet LM 10.04 Magnetic switches Magnetic switch, model BGU, see data sheet LM 10.06 Ex c, GL, GOST-R Page 13 of 16

Option bypass chamber end Bypass chamber end top (examples) 1 Flat top without venting 2 Flat top with vent plug G 1/2" 3 with vent plug G 1/2" 4 e.g. sealing faces groove/tongue per DIN 2512 5 Flat top with vent flange 6 vent flange 7 Flat top with vent valve 8 with vent valve Other ends on request Bypass chamber end bottom (examples) 9 with drain plug G/NPT 1/2" 10 e.g. sealing faces groove/ tongue per DIN 2512 with drain plug G 1/2" 11 with drain nozzle 12 with drain valve 13 with drain flange Other ends on request Page 14 of 16

Option process connection 14 Welding neck flange up to DN 25 15 Blind flange above DN 32 16 Threaded coupling GN... (male thread) 17 Threaded coupling GM... (female thread) 18 Weld stub S... Examples 19 Standard version Process connections 2 x lateral 20 1 process connection lateral 1 process connection vertical (top) 21 2 process connections to DIN 11851 Lower process connection via eccentric reducer 22 2 process connections vertical (top/bottom) Option: Support bracket Other connections on request Page 15 of 16

CE conformity Pressure equipment directive 97/23/EC, pressure accessory ATEX directive (option) 94/9/EC, ignition protection type Ex c, zone 0/1, gas GL, ships, shipbuilding, offshore, Germany DNV, ships, shipbuilding, offshore, Norway ABS, ships, shipbuilding, offshore, USA GOST, national standard for Russia, Kazakhstan and Belarus and certificates, see website Ordering information Model / Approval / Material / Process specifications (operating temperature and pressure, density) / Process connection / Centre-to-centre distance M... Detailed information on floats, magnetic displays, sensors (reed chains and magnetostrictive) and magnetic switches can be found in the following data sheets:, model BFT; see data sheet LM 10.02 Magnetic display; model BMD; see data sheet LM 10.03 Reed sensor; model BLR; see data sheet LM 10.04 Magnetostrictive sensor; model BLM; see data Guided wave radar, model GTR, see data sheet LM 20.05 Magnetic switch; model BGU; see data sheet LM 10.06 2010 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. Page 16 of 16 WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de 01/2015 EN