TC-3000B Bluetooth Tester

Similar documents
RFSPACE CLOUD-IQ #CONNECTED SOFTWARE DEFINED RADIO

WLAN Protocol Tester PTW 70

How To Use A Sound Card With A Subsonic Sound Card

Rayson. Bluetooth Module

Agilent N4010A Wireless Connectivity Test Set

Vector Signal Analyzer FSQ-K70

khz to 2.7 GHz Spectrum Analyzer

BROADCAST Trasmettitori / Transmitters DBH3 GAP FILLER

Impedance 50 (75 connectors via adapters)

AN4494 Application note

Guangzhou HC Information Technology Co., Ltd. Product Data Sheet

Guangzhou HC Information Technology Co., Ltd. Product Data Sheet

RN-41/RN-41-N Class 1 Bluetooth Module

5 in 1 DVB-T Transmitter & Dual Cast Agile Digital Transposer TV EQUIPMENT

USB Smart Power Sensor

Agilent GSM/EDGE Base Station Test with the E4406A VSA and ESG-D Series RF Signal Generators Product Overview

Multi-Range Programmable DC Power Supplies 9115 Series

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

R&S ZNC Vector Network Analyzer Specifications

DSA800 Series Spectrum Analyzer

Class2 BC04-ext Module

R&S ZNBT8 Vector Network Analyzer Specifications

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments. Application Note

DVT913 TV CHANNEL CONVERTER

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz

Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP

Design Considerations for DVT and Manufacturing Test of Wireless Devices

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

A Low Frequency Adapter for your Vector Network Analyzer (VNA)

Guangzhou HC Information Technology Co., Ltd. Product Data Sheet

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Practical Manufacturing Testing of Bluetooth Wireless Devices

USB Smart Power Sensor

How To Sell A Talan

iva Cable & Antenna Analyzer

CX380X Advanced Spectrum and Burst QAM Analyzer

Network analyzer and spectrum analyzer two in one

Rayson Technology Co., Ltd.

Keysight N9320B RF Spectrum Analyzer

Application Note Receiving HF Signals with a USRP Device Ettus Research

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

USB Smart Power Sensor

FRAUNHOFER INSTITUTE FOR INTEg RATEd CIRCUITS IIS. drm TesT equipment

ELAD FDM-S1 USER MANUAL. Ver. 1.01

PXI. GSM/EDGE Measurement Suite

Raptor RXi Ultra-fast scanning Countersurveillance Receiver

Keysight Technologies N9320B RF Spectrum Analyzer

Agilent Compatibility of USB Power Sensors with Agilent Instruments. Application Note

PCI-SIG ENGINEERING CHANGE NOTICE

Ideal for high dynamic range measurements from compression to noise floor

Agilent Test Solutions for Multiport and Balanced Devices

R&S ZVA Vector Network Analyzer Specifications

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Experiment 7: Familiarization with the Network Analyzer

Multi-Range Programmable DC Power Supplies 9115 Series

Agilent Technologies. Generating Custom, Real-World Waveforms Integrating Test Instrumentation into the Design Process Application Note 1360

GRF-3300 RF Training Kits

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

One Port Network Analyzer

Bluetooth UART/RS232 Module

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

AC3200 INTELLIGENT BROADBAND AMPLIFIER

AM/FM/ϕM Measurement Demodulator FS-K7

iva Cable & Antenna Analyzer

Handheld Spectrum Analyzer

LT-82 Stationary IR Transmitter

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

Spectrum Analyzer Two models available: OGR-24 (24 GHz) and OGR-8 (8 GHz)

Signal and Tracking Generator

EN v1.2.1 TEST REPORT FOR ag/Draft n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER

Bluetooth Manufacturing Test A Guide to Getting Started. Application Note

IQview TM For WLAN and Bluetooth

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

R8000A Communications System Analyzer

R&S SMZ Frequency Multiplier Specifications

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

Wideband USB Synthesized Signal Generator. Dynamic range 70 db, output power from -60dBm to +10dBm in 0.25dB steps

Spectrum Analyzer Two models available: OGR-24 (24 GHz) and OGR-8 (8 GHz)

EE 186 LAB 2 FALL Network Analyzer Fundamentals and Two Tone Linearity

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers

GSM/EDGE Output RF Spectrum on the V93000 Joe Kelly and Max Seminario, Verigy

Quick Start Guide. MRB-KW01 Development Platform Radio Utility Application Demo MODULAR REFERENCE BOARD

RF and Microwave Accessories. CD-ROM Catalog. Find the right component for your Rohde & Schwarz test & measurement equipment

Application Note Noise Frequently Asked Questions

M2M I/O Modules. To view all of Advantech s M2M I/O Modules, please visit

Agilent E6832A W-CDMA Calibration Application

DS1104 R&D Controller Board

Wireless Connectivity Testing

Scalar Network Analyzer

ATB50v1 GPRS / GPS Based Fleet Management Terminal. Datasheet

Features. Applications. Transmitter. Receiver. General Description MINIATURE MODULE. QM MODULATION OPTIMAL RANGE 1000m

Frequency selective monitoring and logging of environmental electromagnetic fields

Bluetooth to Serial Adapter

TEST REPORT FROM RFI GLOBAL SERVICES LTD

'Possibilities and Limitations in Software Defined Radio Design.

Transcription:

TC-3000B Bluetooth Tester Product Description TC-3000B Bluetooth Tester Data Sheet TESCOM TC-3000B Bluetooth Tester eliminates the need for several costly testers by combining key RF, Audio, and Protocol test & measurement functions in one convenient box. Designed for a wide range of applications in R&D, manufacturing, QA and service, this feature-packed powerful instrument is simple to use, lightweight and portable, and may be operated with all standard AC voltages. In addition to Bluetooth testing applications, TC-3000B may be used for non- Bluetooth RF testing along the 2.4GHz ISM band. Host GUI LAN RS-232C Remote Operation System Architecture: TC-3000B is made up of two main blocks, a RF/DSP module and a host CPU module, and is Library of Test & Measurement Functions Upper Layers of the Bluetooth Protocol stack HCI 1 Transport Layer (USB, RS-232C) HCI 2 (USB, RS- 232C,UART, BCSP) Control DUT connected by a host controller interface (HCI) that is identical to Bluetooth system architecture. The RF/DSP module provides an RF interface to DUT, performs physical measurements and manages the Bluetooth link. The internal host CPU (PC), which runs on a Linux platform, takes care of user USB (RS-232) bus interface (UI) functions including display, key input HCI Transport Layer (USB,RS-232C) Baseband and LMP layers of the Bluetooth Protocol stack RF firmware and hardware Host Controller External HOST and I/O controls for RS-232C, USB, LAN and other standard peripheral devices. The adoption of an open OS minimizes unnecessary constraints on system optimization. This simple, elegant system architecture takes advantage of both the power of DSP and the convenience of a PC. Custom Protocol Stack: User definable Baseband IN/OUT ports for monitor and external modulation. (RX (I, Q), TX (I, Q), Demodulation, Modulation, RX and TX bit streams, RX and TX Clocks) The TC-3000B Bluetooth protocol stack has been developed with in-house technology in order to gain total control of the performance and feature set of the tester. Its unique protocol stack architecture positions queues between protocol layers, making it conceptually simple and easy to apply. This TEL: 817-503-8862 FAX: 817-503-8866 Email: sales@ctscorp-usa.com, http://www.ctscorp-usa.com 1-9

approach helps guarantee the system s long-term supportability, while efficiently handling future customization and enhancement requirements. Versatility of TC-3000B: TC-3000B can interface with DUT through most known HCI interfaces. Additionally, the RF/DSP module can relinquish control to an external PC through standard HCI, allowing for an emulated Bluetooth development environment. Remote connection through TCP/IP allows the efficient control of multiple testers from a PC located practically anywhere in the world. Speed test mode: It is essential to minimize the test time in manufacturing. TC-3000B is capable of skipping the time-consuming INQUIRY procedure by reading the Bluetooth device (BD) address directly through HCI or presetting BD address. Test configurations can be edited to reduce the number and time of tests. Key Features! Bluetooth V1.1/V1.2/V2.0 Specification Compliant! RF, Audio, and Protocol Combination Tester! Bluetooth Conformance Test - Test Cases defined in Bluetooth Test Specifications - 12 RF test cases supported including dirty transmitter, spectrum - 13 basic Baseband test cases - Local and Remote HCI Loopback Test - User definable test parameters and limits - Quick Test Mode for four(4) RF test cases! Supports Audio (SCO Link) Functional Testing (3000-10) - Verification of Audio quality(sinad, Distortion) - Audio Spectrum - SCO Loopack Function 2-9

! Bluetooth RF and Baseband Measurement Functions (3000-20) - Basic spectrum analyzer - Modulation waveform - Power versus time - Power versus channel - RX Bit Error Rate (RX BER)! Basic Bluetooth Protocol Analyzer Functions (3000-30) - Supports Master and Slave modes - Link test in Pico-net - Packet information in Baseband, LMP, HCI, SDP, RFCOMM, and Profile - Direct HCI command execution from the screen! Bluetooth EDR (3000-40) - I-Q Constellation - DEVM (Differential Error Vector Magnitude) - TX Bit Error Rate (TX BER) - 7 EDR RF test cases supported including dirty transmitter, spectrum! Utility digital signal generator! User definable Baseband IN/OUT ports for real time signal monitoring, external modulation, audio source and audio analyzer! Device HCI Interface Options: USB and RS-232C (UART, BCSP)! Remote Operation: TCP/IP (LAN) and RS-232C! Easy S/W Upgrades through TCP/IP (LAN) or Diskette! Listed on the Bluetooth Qualified Products List (QPL) as a Development Tool! CE Compliant: EN61010-2001, EN61326,A2:2001, EN61000-3-2, 2000, EN61000-3-3,A1:2001 3-9

Specification RF SOURCE Output Frequency Range: 2.4GHz ~ 2.5GHz Accuracy: ± 46Hz + Frequency Reference Drift Resolution: 1 KHz Switching Time: <160us, ± 75kHz of the final frequency Output Level Range: 0 ~ -80dBm Accuracy: ± 1dB Resolution: ± 0.1dB Modulation Type: GFSK BT=0.5 Deviation Range: 0.00 ~ 1MHz Resolution: 600KHz Modulation Rate: 0 ~ 1Mbps RF ANALYZER Input Frequency Range: 2.4GHz ~ 2.483GHz Accuracy: ±46Hz + Frequency Reference Drift Resolution: 1 KHz LO Switching time: <160us, ± 75kHz of the final frequency Input Level Range: -10 ~ -80dBm (+20dBm ~ -50dBm with 30dB attenuator ON) Absolute Max: +25dBm Accuracy: ± 1dB, 0.1dB resolution Intermediate Frequency IF Frequency: 70MHz Filter BW: 10MHz Max, Sampling Rate: 40MHz 1MHz Digital Filter ON/OFF SPECTRUM ANALYZER Frequency Range: 2.4~2.483GHz 4-9

Max Span: 10MHz Resolution BW: ~40KHz at 10MHz Span. Averaging: 1~50 FM MODULATION ANALYZER Modulation: FM, GFSK Frequency Response: 1MHz with channel filter selected Deviation range: 0~4MHz Resolution: 0.1KHz Frequency Accuracy: 1KHz POWER-TIME Level accuracy: ± 1dB, 0.1dB resolution Trigger Method: Access Code (BT), Power Level POWER-CHANNEL (BT Mode) Level accuracy: ± 1dB, 0.1dB resolution DUT Mode: Null Packet or Test Mode RX BER TEST (BT Mode) DUT Mode: Requires Loopback Test Mode Graph: Log Scale BER-Time or BER-RX Power(TBD) Reading: %, Instantaneous, Cumulative Parameters: RX Power, Measurement Data Length, Packet Length/Type I-Q CONSTELLATION (EDR BT Mode) DUT Mode: Requires EDR Test Mode Graph: Display I-Q symbol of DPSK Parameters: Symbol start point, Number of symbol TX BER TEST (BT Mode) DUT Mode: Requires EDR Transmitter Test Mode Graph: Log Scale TX BER-Time and PER (Packet Error Rate) Reading: %, Instantaneous, Cumulative Parameters: Number of packet DEVM (Differential Error Vector Magnitude) DUT Mode: Requires EDR Test Mode Graph: Display DEVM on time axis. Useful for measuring DEVM variance in a packet. 5-9

FREQUENCY REFERENCE Internal Reference Stability: ± 1ppm, -20 ~ 70, 0.5ppm/year External Reference: 10MHz FRONT PANEL RF In/Out Port: N-type, 50 ohm, VSWR <1.6 Baseband In/Out ports: 4 BNC - RX (I, Q), TX (I, Q), Demodulation, Modulation, RX and TX bit streams, RX and TX Clocks, Audio REAR PANEL HCI Interface for DUT: RS-232C, USB, PCMCIA Remote Programming Interface: TCP/IP (LAN) MISCELLANEOUS Operating temperature: 5 ~ 40 Line Voltage: 100 to 240 VAC, 50/60Hz Dimension: 375(w) x 432(d) x 220(h) mm Weight: 10Kg 6-9

Bluetooth Test Platform TC-3000B combined with a TESCOM quality test fixture provides predictable RF coupling and shielding performance, to offer an economical, quality Bluetooth test platform for production, service or R&D environments. Since most Bluetooth devices use sealed antenna due to their size, final RF tests must be done over the air (OTA). In case of module or PCB testing, contact probes may also be used. In either case, testing must be completed under an adequately RF isolated condition with reliable RF coupling. A simple isolation box that disregards internal resonance and shielding qualification will result in unreliable RF test data. All TESCOM isolation boxes are designed to minimize this problem. In practice, OTA coupling over a wide frequency band exhibits some level of frequency slope due to antenna bandwidth or cable connector reflections. This channeldependent residual slope may need calibration to guarantee the accuracy of TX power measurement. TEM Cell TC-5060A/B TEM Cell is a broadband radiation test cell that provides both high isolation and predictable RF coupling. The total coupling loss through typical DUT antenna to TEM Cell output is around 30dB at Bluetooth frequencies. With the additional filtered data port and power lines, the desktop-size TC-5060A/B offers an ideal radiation test platform for small RF devices, such as Bluetooth devices. Shield Box TESCOM s popular absorber-lined Shield Boxes are widely used for RF test fixtures in R&D, service or manufacturing worldwide. These manual or pneumatic boxes with device fixtures can handle many different types of devices, such as PC assemblies, RF modules or final products. Various RF signal connection methods, such as probe heads, OTA couplers or special connectors, can also be supplied by TESCOM. Most units also include the pneumatic operation option, which relieves operator fatigue in manufacturing. High isolation and the absence of in-band resonance in every TESCOM boxes improve test repeatability. 7-9

Test Platform Examples TESCOM provides complete Bluetooth test solution options. Some examples are shown below: Set Test Mode HCI RF Coupler TC-59XX Shield Box Set Test Mode HCI Probe/ Connector TC-59XX Shield Box HCI TC506X TEM Cell Set Test Mode 8-9

Ordering Information BASE UNIT TC-3000B, Includes 12 RF Test Cases and 13 Baseband Cases. OPTIONS 3000-10, Audio Measurement. Includes SCO Link, Audio Test, and Audio Spectrum. 3000-20, Additional Measurement Functions. Includes Spectrum, FM Modulation, Power Channel, Power Time, and BER. 3000-30, Protocol Analyzer. Includes Link Analyzer (Link, Packet Information, LMP, HCI, Baseband information) and Host Analyzer (Link, L2CAP, RFCOMM, SDP, Profile). 3000-40, EDR(Enhanced Data Rate) option. Support EDR link. Includes 7 EDR RF Test cases. EDR Measurement (Constellation, DEVM, TX BER) SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. Bluetooth is a trademark owned by Bluetooth SIG. and licensed to TESCOM. 9-9