IGSA POWER GENERATION SYSTEMS



Similar documents
PM734F - Technical Data Sheet Winding 28

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

BCI184E - Technical Data Sheet

PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

UCI274C - Technical Data Sheet

UCI274H - Technical Data Sheet

HCM434F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PI734D - Technical Data Sheet

PI734B - Technical Data Sheet

DIESEL GENERATOR SETS

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Diesel Generating Set

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

3790 en / d. Alternators LSA Pole. Electrical and mechanical data

Annex-A TECHNICAL SPECIFICATION

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

Spark-ignited generator set

Magnum Mobile Generator MMG55 Specifications

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

Diesel Engine Driven Generators Page 1 of 6

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

Marine Generating Sets 3.7 to 50 kva

How To Control A Power Command Powerplant

How To Use A Cat Diesel Engine

C18 ACERT Fire Pump Tier bkw/ rpm

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

Diesel Generator Set Model DGDK 60 Hz

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

Diesel Generator Set Model DFHC 60 Hz

Diesel Generator Set Model DFMB 60 Hz

Technical Specification. Generating Set with Waukesha engine burning natural gas

APS100 Rental Generator Set Specification

STANDBY 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) rpm

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

1100 Series 1104C-44TAG2 Diesel Engine ElectropaK rpm

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

C18 Diesel Oilfield Generator Set

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

Specifications for Volkswagen Industrial Engine

Industrial Generator Set Accessories

3516 Industrial Engine

Atlas Copco Generators

CUKUROVA GENERATOR SYSTEMS

Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8

Rental. C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES

1 Air-to-Air AfterCooling. 2 Engine Only. Capacity will vary with radiator size and use. of cab heater.

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

NATURAL GAS CONTINUOUS 725 ekw 906 kva 745 ekw 931 kva 770 ekw 963 kva 50 HZ 1500 RPM 400 VOLTS

NATURAL GAS CONTINUOUS 1000 ekw 1250 kva 50 HZ 1500 RPM 400 Volts

3516B Offshore Generator Set

3516B Offshore Emergency Generator Set

Fire Pump Plan Review March 2010

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 480 Volts

1000 kva POWER MODULE UTILITY SWITCHGEAR C32 ACERT TECHNOLOGY 50 / 60 Hz CONVERTIBLE SOUND ATTENUATED ISO 20 FT. CSC CERTIFIED

A Single Source for all Power System Solutions

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 10 kw 12.

Effective: September 10, 2006 Vermont Attachment 1 to Rule Public Service Board Page 1 of 6

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

HFW-100 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

STANDBY 3200 ekw 4000 kva 50 Hz 1500 rpm Volts

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

CREATING POWER SOLUTIONS. 2L41C 3L41C 3L43C 4L41C 4L42C 4L43C. Hatz Diesel.

912. The engine for construction equipment.

The Yachtmans Choice...

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

Phase Modular Finally the benefits of Modular ups are for all

WÄRTSILÄ 34DF PRODUCT GUIDE

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

1013 E. The engine for agricultural equipment.

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

CUKUROVA GENERATOR SYSTEMS

X G R E N T A L

SG035. Industrial Gaseous Generator Set. SG035 35kW. primary codes and standards. Standby Power Rating 44kVA 35kW 60Hz

WÄRTSILÄ 50DF PRODUCT GUIDE

Engine Power Plant 5,2 MW Stationary Dual Fuel (Diesel / Gas ) Engine (12 VDS 48/42 )

Medical Air Systems: Scroll

PacifiCorp Original Sheet No. 476 FERC Electric Tariff, Substitute 6 th Rev Volume No. 11 APPENDIX 2 TO SGIP

A reasonable, new furnace (mid efficiency) has the following electrical requirements:

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Transcription:

IGSA POWER GENERATION SYSTEMS MODEL: GSDD20600S. MTU, 12V1600G80S, 1800 RPM, 60 HZ. CAPACITY KW KVA 600 750 Reference Conditions ISO 3046: Intake air temperature Side altitude above sea level Charge air coolant temperature Standard 25 C (77 F) 100 m (328.08ft) 45 C (113 F) Standard Features Complete system designed and built at ISO 9001: 2008 certified facilities. Factory tested to design specifications at full load conditions. Fully engineered with a range of options and accessories. 1. IGSA, Genset s are composed of 12 cylinders in V, and four strokes diesel engine for industrial stationary applications. Those equipments are fully factory tested using a resistive load. (1) Hour ramp 100% load test. 2. The controls and accessories are selected to work together to achieve the maximum operational performance and security. 3. Exhaust gases silencer, and a section of flexible tube for connection purposes. 4. Engine MTU 5. Alternator Stamford 6. Control DEEP SEA 7320 7. Base of structural steel. 8. Standard and optional equipment may vary for UL 2200 listed packages. UL 2200 listed packages may have oversized generators with a different temperature rise and motor starting characteristics. General Features IGSA GENSET of 600 kw to 480V, 460V, 440V, 416V, 380V, 240V, 230V, 220V, 208 V, 190V AC. 3 Phase, 4 Wire, 60 Hz, is composed by an internal engine four strokes coupling with the alternator, controls and accessories totally assembled and tested in factory. The controls and accessories of the Genset are selected to provide the maximum in efficiency and Security The Genset engine is certified by the Environmental Protection Agency (EPA) to conform to Tier 2 non road emissions regulations. Electronic engine controls manage the engine (isochronous). Integrated complete system control and monitoring (ADEC). WE ARE THE BEST IN MANUFACTURING THE POWER GENERATION SYSTEMS AND ADDITION CONSTANTLY INNOVATION. ALL RIGHTS RESERVED PRINTED IN MEXICO MATERIALS AND SPECIFICATIONS ARE SUBJECTS TO CHANGE WITHHOUT NOTICE. THE INTERNATIONAL SYSTEM OF UNITS (SI) IS USED IN THIS PUBLICATION 1-6 FO-GI-01-25 REV 01

MTU ENGINE SPECIFICATION MODEL 12V1600G80S, WEIGHT 1918 Kg. (4228.46 Ib.) General Data Starting (Electric) Model 12V1600G80S Starter, rated power (make PRESTOLITE),(Kw) 8 Combustion System Direct Injection Starter, rated voltage, (V) 24 Aspiration Engine with exhaust Starter, power requirement max., (A) 800 turbocharger (ETC) and Starter, power requirement at firing speed, (A) 250 intercooler Start attempt duration (engine preheated), (s) 5 Bore x stroke 122/150 mm Start attempt duration (engine not preheated),(s) 5 Displacement 21 Liters Start attempt duration, max., (sec) 10 Number of cylinders 12 Coolant preheating Coolant preheating, preheating temperature Cylinder configuration: 90 (min.), ( C) 32 Coolant preheating, heater performance Compression Ratio 17.5 (standard), (Kw) 3 Direction of rotation: Coolant System (High-Temperature Circuit) Standard flywheel housing flange (engine main PTO) SAE 01 Coolant temperature engine outlet to cooling equipment),( C) 95 Flywheel interface (DISC) DISC14 Coolant temperature after engine, alarm, ( C) 105 Number of starter ring-gear teeth on engine Coolant temperature after engine, shutdown( C) flywheel 157 Injection system Control / Monitoring high pressure fuel lines and Electronically controlled injection. Integrated electronic engine control and monitoring system ADEC Number of turbochargers 2 109 Coolant antifreeze content, max., % 50 Cooling equipment: coolant flow rate, m 3 /h 31 Pressure loss in off-engine cooling system, max., bar 0.7 height above engine, max., m 15 Coolant pump: inlet pressure, min., (bar) 1.4 Coolant pump: inlet pressure, max., (bar) 3.5 Breather valve (expansion tank) opening pressure (excess pressure), bar 1.0+0.3 Breather valve (expansion tank) opening pressure (depression), bar -0.2 Number of intercoolers 2 Fuel stop power ISO 3046, kw (hp) 668 Pressure in cooling system, max., (bar) 5 Mean piston speed, (m/s) 9.0 Combustion Air / Exhaust Gas Mean effective pressure (MEP) Charge-air temperature before cylinder, C (Fuel stop power ISO 3046), bar 21.21 50 Phisical Data Charge-air flow through external air-to-air intercooler, m³/s 0.43 Engine dry weight (with engine-mounted Charge-air temperature before external air-to-air standard accessories, without coupling), (kg) 1855 intercooler, C 200 Engine weight, wet (with engine-mounted standard accessories, without coupling), (kg) 1918 Charge-air temperature after external air-to-air intercooler, C 50 Length--in.(mm) ---- Charge-air temperature after external air-to-air intercooler, max., C 65 Height--in.(mm) ---- Charge-air temperature after external air-to-air intercooler, min., C -15 Width--in.(mm) ---- Pressure differential in external air-to-air intercooler, max., mbar 130 Fuel consumption L / hrs (Standby) Charge-air pressure before cylinder FSP, bar abs 3.2 Power at 100 % 151.68 Combustion air volume flow FSP, m³/s 0.90 Power at 75 % 114.35 Fuel System Fuel pressure at fuel feed connection, min. 80.16 Power at 50 % (when engine is starting), bar -0.5 Fuel pressure at fuel feed connection, max. 45.58 Power at 25 % (when engine is starting), bar 0.5 Fuel supply flow, max., liter/min 6.7 Engine coolant capacity (without cooling equipment), (Lt) 65 On-engine fuel capacity, (Lt) 3 Engine oil capacity, initial filling standard oil system), (Lt) 72.5 Oil change quantity, max. (standard oil system), (Lt) 64 Oil pan capacity, dipstick mark min. (standard oil system), (Lt) 56 Oil pan capacity, dipstick mark max. standard oil system), (Lit.) 64 Heat Dissipation Heat dissipated by engine coolant - FSP with oil heat, without charge-air heat, (Kw) 270 Capacity Fuel return flow, max., liter/min 6.5 Fuel temperature dif., before/after engine, C Exhaust System Exhaust volume flow (at exhaust temperature) - FSP m³/s 2.2 Exhaust temperature after turbocharger FSP, C 425 Exhaust back pressure, max., mbar General Operating Data High idling speed, max. (static), rpm 1870 Engine coolant temperature before starting Charge-air heat dissipation - FSP, (Kw) 170 full-load operation, recommended min., C 60 Heat dissipated by return fuel flow - FSP,(Kw) 4.6 Minimum continuous load, % 20 Radiation and convection heat, engine FSP, (Kw) 24 Engine surface noise with attenuated intake noise (intake silencer) - FSP, 1m distance,(db (A)) Acoustics Exhaust noise, unsilenced - FSP, 1m distance, db(a)) 110 Exhaust noise, unsilenced - FSP, (db(a)) 123 20 150 Engine mass moment of inertia (without flywheel), kgm² 1.548 Engine mass moment of inertia (with standard flywheel), kgm² 2.988 101 Standard flywheel mass moment of inertia, kgm² 1.44 Longitudinal inclination, continuous max. driving end down / up / transverse inclination, degrees ( ) 15 2-6 FO-GI-01-25 REV 01

STAMFORD ELECTRIC ALTERNATOR MODEL HCI534E/544E, WEIGHT 1535 Kg. (3384 LB) CONTROL SYSTEM SEPARATELY EXCITED BY P.M.G. A.V.R. MX321 MX341 VOLTAGE REGULATION (+/- 0.5%) (+/- 1.0%) WITH 4% ENINE GOVERNING SUSTAINED SHORT CIRCUIT REFERENT TO SHOT CIRCUIT DECREMENT CURRENT CONTROL SYSTEM SELF EXCITED A.V.R. SX440 SX421 VOLTAGE REGULATION (+/- 1.0%) (+/- 0.5%) WITH 4% ENINE GOVERNING SUSTAINED SHORT CIRCUIT SERIES 4 CONTROL DOES NOT SUSTAIN SHORT CIRCUIT CURRENT INSULATION SYSTEM CLASS H PROTECTION IP23 RATED POWER FACTOR 0.8 STATOR WINDING DOUBLE LAYER CONCENTRIC WINDING PITCH TWO THIRDS WINDING LEADS 12 STATOR WDG. RESISTANCE 0.0043 Ohms PER PHASE AT 22 C (71.6 F) SERIES STAR CONNECTED ROTOR WDG. RESISTANCE 1.96 Ohms at 22 C R.F.I. SUPPRESSION BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others WAVEFORM DISTORTION NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0% MAXIMUM OVERSPEED 2250 Rev/Min BEARING DRIVE END BALL. 6220-2RS. (ISO) BEARING NON-DRIVE END BALL. 6314-2RS. (ISO) 1 BEARING 2 BEARING WEIGHT COMP. GENERATOR 1543 kg 1535 kg WEIGHT WOUND STATOR 722 kg 722kg WEIGHT WOUND ROTOR 617 Kg 588 kg WR² INERTIA 8.9828 kgm2 8.7049 kgm2 SHIPPING WEIGHTS in a crate 1635 kg 1625 kg PACKING CRATE SIZE 166 x 87 x 124 (cm) 166 x 87 x 124 (cm) 50 Hz 60 Hz TELEPHONE INTERFERENCE THF<2% TIF<50 COOLING AIR 1.035 m³/seg 2202 cfm 1.312 m³/seg 2780 cfm VOLTAGE SERIES STAR 380/220 400/231 415/240 440/254 416/240 440/254 460/266 480/277 VOLTAGE PARALLEL STAR 190/110 200/115 208/120 220/127 208/120 220/127 230/133 240/138 VOLTAGE SERIES DELTA 220/110 230/115 240/120 254/127 240/120 254/127 266/133 277/138 kva BASE RATING FOR RECTANCE VALUES 600 600 600 600 681 713 731 750 Xd DIR. AXIS SYNCHRONOUS 3.14 2.83 2.63 2.34 3.53 3.30 3.10 2.92 X'd DIR. AXIS TRANSIENT 0.17 0.15 0.14 0.12 0.17 0.16 0.15 0.14 X''d DIR. AXIS SUBTRANSIENT 0.12 0.11 0.10 0.09 0.12 0.11 0.11 0.10 Xq QUAD. AXIS REACTANCE 2.45 2.21 2.05 1.82 2.82 2.64 2.48 2.33 X''q QUAD. AXIS SUBTRANSIENT 0.26 0.24 0.22 0.20 0.34 0.32 0.30 0.28 XL LEAKAGE REACTANCE 0.06 0.05 0.05 0.04 0.06 0.06 0.05 0.05 X2 NEGATIVE SEQUENCE 0.18 0.16 0.15 0.13 0.23 0.22 0.20 0.19 X0 ZERO SEQUENCE 0.08 0.08 0.07 0.06 0.10 0.09 0.09 0.08 REACTANCES ARE SATURATED T'd TRANSIENT TIME CONST. T''d SUB-TRANSTIME CONST. T'do O.C. FIELD TIME CONST. Ta ARMATURE TIME CONST. SHORT CIRCUIT RATIO VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATED 0.08 s 0.012 s 2.5 s 0.019 s 1/Xd RATINGS: All three-phase units are rated at 0.8 power factor. All single-phase units are rated at 1.0 power factor. Standby Ratings: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. GENERAL GUIDELINES FOR DERATION: Altitude: Derate 1.0% per 100 m (328 ft.) elevation above 400 m (1312 ft.). Temperature: Derate 3.0% per 5.0 C (9 F) temperature above 40 C (104 F). 3-6 FO-GI-01-25 REV 01

CONTROLLER FOR GENSET: DEEP SEA 7320 TECHNICAL SHEET The Generator Controller DEEP SEA 7320 is a microprocessor-based control unit containing all necessary functions for protection and control of a power generator. Besides the control and protection of the diesel engine it contains a full 3-phase AC voltage and current measuring circuit. The unit is equipped with an LCD display presenting all values and alarms. Graphic Display 128 X 64 pixels (STN) Super Twisted Nematic Digital AC Metering: o 3-Phase Volts (Phase to Phase and Phase to Neutral), o 3-Phase Amps o Frequency o kw, kvar, KVA, pf, kwhr o AC Protective Relaying: o 27/59 Under/Over Voltage o 32 Reverse Power o 51 Time Overcurrent o 81 O/U Under/Over Frequency o Digital gauge display o Oil Pressure (sender required by others) o Coolant Temperature (sender required by others) o Fuel Level (sender required by others) o Hourmeter o Tachometer DEEP SEA 7320 FEATURES Electrical Rating: Single or three phase, 600VAC maximum, 50/60HZ, 4 wire 12 or 24Vdc (nominal) supply, negative ground. Dedicated Output Contacts - Engine Crank; Run (30 VDC / 6 Amps) Three Programmable Output Contacts (30 VDC / 1 Amps) 5 digital inputs for alarms / shutdowns Dedicated Output Contacts - Engine Crank; Run (30 VDC / 6 Amps) Three Programmable Output Contacts (30 VDC / 1 Amps) Event Logging (30 events) Pushbuttons: Emergency Stop Manual Start and Stop Manual/Auto/Test Lamp Test Horn Silence Indicating Lights: Common Alarm Generator Ready (Voltage and Frequency Normal). Basic model 7320. Model for synchrony 7510, 7520 and 7560. Engine Senders: Oil pressure (1/8 NPT), Temperature (1/4 NPT) (Supplied loose for engine mounting). Requirements: Exceeds requirements of CSA 282 and NFPA 110 Level 4-6 FO-GI-01-25 REV 01

OPTIONAL SILENCER ACCORDING TO THE APPLICATION Silencer with different levels from attenuation: Critical Grade Super Critical Grade Hospital Grade Levels from attenuation DOCUMENTATION AND OTHERS Manual of operation and maintenance Spare parts Maintenance Consulting MISCELLANEOUS EQUIPMENT Batteries of 12 VDC with cables for battery connection with the Engine. GENSET OPTIONS Control Panel Control Panel is standard on all units see page 4 of spec sheet for standard features. Another Type Fuel system Fuel Water Separator Day tank Auxiliary fuel pump Sub Base mounted Fuel Tank o Single Wall o Double Wall o UL listed o 150 L (39.6 gal) o 250 L (66 gal) Diesel Fuel Tank o 500 L (132 gal) o 1000 L (264.1 gal) o 5000 L (1320.8 gal) Exhaust System Critical Grade Super Critical Grade Hospital Grade Engine Electrical system Battery o Lead-Acid o NiCad Battery Rack Battery Charger Automatic Generator Breaker in the alternator PMG Excitation and voltage regulator DVR 2000. OPTIONAL ACCESSORIES AVAILABLE FOR THE EQUIPMENT Vibration isolation Rigid Spring Mounting Resilient Mounting Filters Air Filter for Medium Dust Environments Air Filter of Heavy Dust Environments Drain Oil drain Extension Enclosures Sound Attenuated Weather Proof Stainless steel cover Trailer Mounting Interior lights Ac or DC Heaters Jacket Water Heater Crankcase Oil Heater Insulation Blankets Features: (Temperature to 1260 C (2300 F), Non- Combustible, Highly Resistant to Vibration, Oil, Fuel, Grease, and Moisture Resistant Exterior, Personal Protection Notes 5-6 FO-GI-01-25 REV 01

DIMENSIONS TECHNICAL SHEET LENGTH WIDTH HEIGHT BASE LENGTH BASE WIDTH BASE HEIGHT mm mm mm mm mm mm 3461 1842 2132 300 1023 254 NOTE: The preliminary general arrangement GENSET shown here should not be used for installation purposes, for more details contact your project leader. SERVICES Development of the project. Development of engineering. Equipment s Installation Engineering for special applications. Synchronies with utility network or more Genset s. Attention and technical support On-Site Acoustic Enclosure ISO Container Trailer INSTALLATION OPTIONS OF THE GENSET DATE NO. REVIEW DEVELOP CHECK APPROVED November 14 2011 00 Eder Adrian P Manufacturing Engineer Hugo Orozco. Engineering Manager Rafael Canepa Production Manager 6-6 FO-GI-01-25 REV 01