PUMP SPY INSTALLATION AND OPERATING INSTRUCTIONS

Similar documents
Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

Leak Detection System

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

1/3 HP Submersible Sump Pump with Vertical Float Switch

Operating Manual Color Changing Fountains

BroadBand PowerShield. User Manual

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Advantium 2 Plus Alarm

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC

Backup Sump Pump Systems. 1 NEXT

Battery Backup Sump Pump System

POOL SUNSHINE IONIZER MODELS SPD, SPD2 AND SPS INSTALLATION INSTRUCTIONS

AM/FM Emergency Weather Radio/Light With Hand Crank Back-Up Power

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

LCD5500Z / PKP-LCD v3.x Installation Instructions

MODEL INSTALLATION INSTRUCTIONS

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

IR Repeater. Operation Manual P8620

Instructions & Safety Information Models A220-20D and A220-20L Version 2

ReadyNet Easy Jack 2 Voice/Data and Data Only Owner s Manual PX-211d and PX-211v

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Battery Backup Sump Pump System

INSTANT HOT WATER RECIRCULATING SYSTEM

SERIES VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

Wireless Phone Jack System

ATS Overhead Table Shelf System INSTRUCTION MANUAL

LF-IRX. Limited Warranty LF-IRX. Remote Control Extender OWNER S MANUAL

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Battery Charger. Instruction Manual G


EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Installation Manual. Model 441 Battery Backup System IMPORTANT: B. *Do not throw away or lose this manual.

Manual Ranging MultiMeter

Oil and Coolant Circulating Heating System. Model - OCSM

Conference Phone UserÕs Manual. Part No R1 Printed in Korea Bogen Communications, Inc.

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

REDI-LINE ELECTRIC GENERATORS USER'S GUIDE. Rugged, Reliable, DC to AC Power Conversion

For Models #6-5001, #6-7501, # & #10-12K1

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Battery Backup Sump Pump System

SUBMERSIBLE PUMP 250 WATTS, WITH FLOAT Model 45014

12-Volt 10-Amp Regulated Power Supply

Customer Support

, User s Manual

12 Volt 30 Amp Digital Solar Charge Controller

USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions

VANGUARD A OPERATOR S MANUAL PORTER. FM-952 Rev. E 7/07

SSNICLRG SSNICSM PLNICLRG PLNICSM

Utility Distribution Systems

Water Leak Detection System

Installation and Operation Guide for PD5100 Automatic Transfer Switch

Installation/Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P

AutoRanging Digital MultiMeter

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

User and Installation Guide

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

Generator Transfer Switch Model # HTS15-AUTO

SUBMERSIBLE SEWAGE PUMP 66119

LED MOTION ACTIVATED FLOOD LIGHT

Color Splash LED Light Fixture Installation and Operation Guide

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

Seven function digital multimeter

Remote Alarm Monitoring System

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Installation and Operating Instructions (for chargers shown below)

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

User Guide. HDMI Active Cable Extender. DVI-7370c

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

A/C-D/C Battery Backup Sump Pump System

RC930 Manual 6/10/99 1:23 PM Page 1. Wireless Modem Jack

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Owner s Manual & Safety Instructions

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

VK-250 WARRANTY REGISTRATION FORM

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

INSTRUCTION MANUAL IM042. Slide Rail Systems - Series A10 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Battery Backup Sump Pump System

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

Battery Backup Sump Pump System

DeltaSpan Submersible Pressure Level Transmitter Manual LD31 Series 22 AUG 08 Rev A

Owner s Manual & Safety Instructions

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

Original instructions Tina 3A/Aps Adaptor unit

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Universal Wireless Effects Controller USER S GUIDE SA115

Model HPX10 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

HP UPS R1500 Generation 3

InHome Water Leak Detection Package

Installation Guide Smart-UPS X External Battery Pack SMX120BP

LOSB9595 1/36 th Brushless ESC and 10250Kv Motor Combination

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

Transcription:

PUMP SPY INSTALLATION AND OPERATING INSTRUCTIONS PumpSpy Tech Support: 515.999.6935 support@pumpspy.com 34000 LEAR INDUSTRIAL PARKWAY, AVON, OH 44011 PumpSpy PS1000 12 VDC Sump Pump Power Supply Requirements Motor AMP Rating Temperature Rating Discharge MAX Flow IMPORTANT! SPECIFICATIONS 12 VDC Brushless DC 18 Amps 40 F to 120 F 1 1/2 NPT 3000 GPH System Solid State Pump Controller Power Supply Requirements Electrical Ratings Relative Humidity Storage Temperature Operating Temperature 120 VAC, 60 Hz, 15 AMP 12Amps @ 120 VAC 18 Amps @ 12 VDC 0 to 80% 0 to 70 C 0 to 50 C The PumpSpy System requires a 12V Deep Cycle Battery with a minimum 75AMP/HR rating. AGM Battery strongly recommended. READ ALL INSTRUCTIONS CONTAINED IN THIS MANUAL BEFORE USING THIS PRODUCT. Save these instructions for future reference. Failure to read and follow the warnings and instructions within this instruction manual could result in property damage, serious injury or death.

WARNING SAFETY FIRST! This instruction manual contains very important information for you to know and understand. This information is provided for your safety and to help prevent equipment problems from occurring. Please observe all safety information labeled danger, warning and caution. WARNING INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH, IF NOT AVOIDED, COULD RESULT IN DEATH, SERIOUS INJURY OR MAJOR PROPERTY DAMAGE. RISK OF ELECTRIC SHOCK. TO REDUCE THIS RISK, OBSERVE THE FOLLOWING WARNINGS: WARNING! To reduce the risk of electrical shock, this system must be properly grounded in accordance with the National Electric Code (NEC) and all applicable state and local codes and ordinances. The receptacle should be protected with a Ground Fault Circuit Interrupter (GFCI). WARNING! To reduce the risk of electrical shock, always disconnect the pump / system from the power source and battery BEFORE handling or servicing. WARNING! Never remove the ground prong from the plug, or use an adapter that eliminates the ground prong. WARNING! Never plug this pump system into an electric outlet while standing on a wet surface. WARNING! Cables should be protected at all times to avoid punctures, cuts and abrasions that may result in exposed wiring. Never handle connected power cords with wet hands. WARNING! The PumpSpy System has not been investigated for use in or around swimming pools, marine areas, recreational water installations, decorative fountains or any installation where human contact with the pumped fluid is common. WARNING! Do not use an extension cord. Extension cords could present a safety hazard if not properly sized, become damaged or the connection falls into the sump pit. Do not attempt to disassemble the PumpSpy controller or Backup Pump. There are no field serviceable parts or repair options! RISK OF EXPLOSION. TO REDUCE THIS RISK, OBSERVE THE FOLLOWING WARNINGS: WARNING! Do not use to pump flammable or explosive liquids such as gasoline, fuel oil, kerosene, etc. WARNING! Do not use in a flammable or explosive atmosphere. NOT SUITED FOR POTABLE WATER APPLICATIONS. WARNING! Do not use this pump to transfer water that will be used for potable (drinking) water. This pump is only to be used in applications for which it is designed. CAUTION CAUTION INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH, IF NOT AVOIDED, MAY RESULT IN MINOR INJURY OR PROPERTY DAMAGE. TO REDUCE THE RISK OF HAZARDS THAT CAN CAUSE INJURY OR PROPERTY DAMAGE, OBSERVE THE FOLLOWING WARNINGS: CAUTION! Do not use discharge hose. Discharge hose may whip under pressure. Use rigid piping and fittings to secure the pump in the sump basin to reduce movement. CAUTION! Do not install the pump if it has been damaged in any way. CAUTION! Do not carry or lift the pump by the power cord. Use the pump s lifting handle.

UNPACKING Inspect this unit before beginning installation. Occasionally, products are damaged during shipment. If the pump or any components are damaged, contact PumpSpy at 515.999.6935, or support@pumpspy.com. The PumpSpy System requires a 12V Deep Cycle Battery with a minimum 75AMP/HR rating. AGM Battery is strongly recommended. INSTALLATION WARNING BEFORE INSTALLING BACKUP PUMP WARNING! Turn power to main pump off! WARNING! Electric shock hazard. DISCONNECT power before servicing. Backup Pump must be installed using 1-1/2 in. rigid PVC pipe! DO NOT over tighten or cross-thread plastic fittings or check valves. Check valves MUST be installed in the discharge line of both the main AC pump and the back-up DC pump. Installation of this unit MAY take several hours. Before disabling your main pump, have a standby pump ready or an appropriate means of evacuating the sump basin. Verify that the existing AC pump is in good working order. If the AC pump is questionable, replace. Remove any debris from the sump pit and surrounding area. The PumpSpy Backup Pump can be installed with a separate discharge line (Method 1), or connected to an existing discharge line (Method 2). FIGURE 1- Separate discharge line METHOD 1 (Separate discharge line) - See Figure 1 1. The backup pump has a 1-1/2 in. NPT discharge. 2. Cut a 3 ft. section of 1-1/2 in. rigid PVC pipe. Glue 1-1/2 in. pipe to a threaded fitting. 3. Screw pipe from step 2 into pump discharge. 4. Place the pump with the 3 ft. section of PVC pipe on a solid, level surface in the sump pit. Do NOT place the pump on a loose or sandy surface. Small stones or sand may damage the pump resulting in pump failure. 5. Attach a check valve (sold separately) to the top of the discharge pipe. A check valve is required for proper operation of system. The remainder of the discharge pipe installation will vary depending on individual circumstances. Using sound plumbing practices, route the discharge pipe to an exterior wall by the shortest path. Keep turns to a minimum because they reduce flow output of the pump.

METHOD 2 (Connecting to existing discharge line) - See Figure 2 If a separate, dedicated discharge is not desired as in Method 1, the Backup Pump can be tied into the main pump s discharge pipe by installing a Y connector. Two check valves will be required. 1. This pump has a 1-1/2 in. NPT discharge. 2. Cut a 3 ft. section of 1-1/2 in. rigid PVC pipe. Glue 1-1/2 in. pipe to a threaded fitting. 3. Screw pipe from step 2 into pump discharge. 4. Place the pump with the 3 ft. section of PVC pipe on a solid, level surface in the sump pit. Do NOT place the pump on a loose or sandy surface. Small stones or sand may damage the pump resulting in pump failure. 5. Attach a check valve (sold separately) to the top of the discharge pipe. A check valve is required for proper operation of system. 6. Duplicate the discharge piping arrangement for the primary AC pump if the existing discharge line has to be adjusted to accommodate a second pump. 7. Glue a 45º elbow to the pipe on the Backup DC Pump. Glue a Y adapter to the pipe on the main pump, as shown in illustration for Method 2. 8. Glue a short piece of PVC pipe between the 45º elbow and the Y. THE CHECK VALVES FOR BOTH PUMPS MUST BE INSTALLED BELOW THE Y FITTING! The remainder of the discharge pipe installation will vary depending on individual circumstances. Using sound plumbing practices, route the discharge pipe to an exterior wall by the shortest distance. AFTER PLUMBING IS COMPLETED, FOR BOTH METHODS 1 AND 2 Install float sensors at least 10 in. -12 in. above bottom of sump pit so that the sensors are higher than the normal on level for main pump. Make sure power wires and hose clamp ends do not interfere with float switch, pump inlet, or main pump operation. Failure to position properly may cause improper operation. Position the float switch so that it will not interfere with any portion of the plumbing, wiring, or sump pit. BACK-UP PUMP OPERATION: 1. The backup pump will turn on when either the bottom or top float sensor rises. 2. The backup pump will keep running for 10 seconds after the float sensor drops. 3. PumpSpy will remotely activate the backup pump during system tests at least 3 times per week. WARNING! PUMPSPY SYSTEM TESTS MAY OCCUR AT ANY TIME. THE BACKUP PUMP MAY CYCLE AT ANY TIME WITHOUT NOTICE.

1. 2. 3. 4. 5. CONNECTING PUMPSPY CONTROLLER 1. Install the Primary Sump Pump and Backup Pump using good plumbing practices. Both the Primary and Backup pumps should set on the bottom of the basin. 2. Install the switches for the primary pump and backup pump. The ON level of the lowest backup switch should be approximately 1 higher than the ON level of the primary sump pump switch. 3. Connect the Backup Sump Pump to the PumpSpy Controller s white jack. 4. Connect the backup switches to the PumpSpy Controller s color coded jacks. 5. VERY IMPORTANT! Connect the Main Sump Pump to the AC outlet on the PumpSpy controller. 6. Mount the PumpSpy Controller s antenna as high as possible, preferably attached to a floor joist or external wall. Remove the backing from the antenna s mounting tape, and fasten the antenna. Press ALARM MUTE to see signal strength. Avoid copper pipes, metal conduits, electrical wiring, or other metal surfaces. 7. Open the battery case and place 12 Volt battery inside. 6. 7. 8. Connect the PumpSpy controller to the battery. Red to +, Black to -. Replace and lock lid on case. 9. Plug the PumpSpy controller into an AC outlet. Consult your local codes for GFCI requirements. 10. The PumpSpy system will initialize and boot up. After booting, the POWER and SYSTEM lights should be GREEN. The DATA light should be BLINKING RED. 8. 9. 10. TEST THE SYSTEM IN THIS ORDER! FILL BASIN WITH WATER, BELOW THE PRIMARY SUMP PUMP S ON LEVEL. CHECK PLUMBING FOR LEAKS DURING TESTING. Lift the lowest Battery Backup switch and hold. Release when the battery backup pump cycles. The PumpSpy controller should sound an alarm with the message Backup On AC On. The SYSTEM light will turn red. REFILL BASIN WITH WATER. Lift the switch for the Primary Sump Pump. Release when Primary Pump cycles for at least 3 seconds. The PumpSpy alarm will stop and the SYSTEM light will be green. The PumpSpy system will begin data sync and the DATA light will turn BLINKING GREEN after the registration process is complete at PumpSpy.com

ACTIVATE THE FREE PUMPSPY MONITORING SERVICE In order to get the most from your PumpSpy system, activate the PumpSpy Remote Monitoring Service. The PumpSpy Remote Monitoring Service computers connect to your PumpSpy System and watch over your system automatically, 24 hours a day. PumpSpy collects operating data on your sump pumps and battery and then analyzes this information to make sure your pumps are always in top working condition. The PumpSpy Remote Monitoring Service activates and tests your pumps at least three times per week. IF A PROBLEM IS DETECTED AT ANY TIME, THE PUMPSPY SYSTEM WILL SEND AN ALERT TO YOUR EMAIL AND MOBILE PHONE. YOU MUST COMPLETE ALL PLUMBING AND THE INSTALLATION PROCESS BEFORE REGISTERING YOUR SYSTEM! THE PUMPSPY MONITORING SERVICE WILL ACTIVATE AND TEST YOUR PUMPS DURING THE REGISTRATION PROCESS! 1. LOCATE YOUR PUMPSPY SERIAL NUMBER With your documentation, there is a registration card with your system s serial number. If you are unable to locate this document, the serial number is also printed on the side of the PumpSpy System Controller. 2. VISIT WWW.PUMPSPY.COM Once you are on the website, click the Login/Activate button. The website will walk you through the registration process, step by step. TROUBLESHOOTING For additional help, visit the FAQ at pumpspy.com or call 515.999.6935 WARNING! Always disconnect the pump from the electrical power source BEFORE handling or servicing. PROBLEM POTENTIAL CAUSE POSSIBLE SOLUTION Backup Pump will not run Loose connections Make sure all connections to Controller are secure Low or defective Battery Check battery and replace if necessary Float Switch is restricted Make sure the float switch is not obstructed by wires or debris Data light blinks red Unit is not registered Register unit online at pumpspy.com to start data sync Poor cell signal Move antenna to better location. Press ALARM MUTE to see signal strength. No Primary Pump Cycles recorded Subscription Suspended Primary Pump not connected Logon to pumpspy.com and update payment method Plug Primary Sump Pump into AC outlet on PumpSpy Controller

LED STATES POWER SYSTEM DATA Green Red Green Red Green Blink Red Blink AC Power is on AC Power not available No current alerts One or more alerts are active System is connected to PumpSpy Remote Monitoring Service System is NOT connected to PumpSpy INFORMATION CENTER LCD MESSAGES System OK Displayed when no alerts are active. Power Fail Displayed when no alerts are active. Backup On/Pwr OK Displayed when backup pump cycles with AC power available for primary pump. (Possible main pump failing) Hi Water in Pit Displayed when high water float sensor is triggered. Main FS Stuck On Displayed when primary pump runtime exceeds normal value. Backup FS Stck On Displayed when backup pump runtime exceeds normal value. Voltage Low Displayed when battery voltage drops below 11.4 volts (50% discharged) Voltage Critical Displayed when battery voltage drops below 10.4 volts (90% discharged) Primary Hi Amps Displayed when primary pump current exceeds baseline amp reading by 50% System Error Displayed when alarm for an alert is muted. Sig Strgth:xx Display of signal strength as read from cellular module (press mute button) Start Autotest Displayed when PumpSpy Monitoring Service initiates a system test Reading Battery Data > Host Displayed when unit measures battery voltage during self test Displayed when system sends alert or self test results to PumpSpy Host Data Valid Displayed when valid command is received from PumpSpy ALARM MUTE BUTTON Clears the alert message displayed on the information center LED Silences the alarm for 24 hours

Limited Three-Year Warranty WHAT THIS WARRANTY COVERS When used and maintained in normal use and in accordance with the Installation and Operating Instructions, your PumpSpy product is warranted against original defects in material and workmanship for a full three years from date of purchase (the Warranty Period ). During the warranty period, PumpSpy will repair or replace at no cost to you, to correct such defects in products found upon examination by PumpSpy to be defective in materials or workmanship. WHAT THIS WARRANTY DOES NOT COVER This warranty does not cover use of the product in a non-residential application, improper installation and/ or improper maintenance of the product, damage due to misuse, acts of God, nature, vandalism or other acts beyond the control of PumpSpy, owner s acts or omissions, use outside the country in which the product was initially purchased and resales of the product by the original owner. This warranty does not cover pick up, delivery, transportation or house calls. However, if you mail your product to PumpSpy for warranty service, cost of shipping will be paid one way. This warranty does not cover products purchased from a party that is not an authorized retailer, dealer, or distributor of PumpSpy products. OTHER IMPORTANT TERMS This warranty is not transferable and may not be assigned. This warranty shall be governed and construed under the laws of the state of Ohio. The warranty period will not be extended by any replacement or repair performed under this warranty. THIS WARRANTY IS THE EXCLUSIVE WARRANTY AND REMEDY PROVIDED BY PumpSpy. ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OR MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT WILL PumpSpy BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND OR NATURE TO OWNER OR ANY PARTY CLAIMING THROUGH OWNER WHETHER BASED IN CONTRACT, NEGLIGENCE, TORT OR STRICT PRODUCTS LIABILITY OR ARISING FROM ANY CAUSE WHATSOEVER. Some states do not allow for the exclusion of consequential damages, so the above exclusion may not apply to you. This warranty gives you specific rights. You may also have others that vary state to state. Installed by: Model : PS 1000 Date of Installation: Serial Number: 83019-04