Modular Ventilation and Filtration System

Similar documents
Laminar Flow Cabinets

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

LAMINAR FLOW CABINETS

Installation and Operating Manual Model F1800C Model F1800PG Model F1802C Model F1802PG Model F1806C Model F1806PG

Ductless Spray Booth Series

SENTRY AIR SYSTEMS, INC. PHARMACEUTICAL COMPOUNDING CONTAINMENT SYSTEMS SIMPLE SOLUTIONS FOR CLEANER AIR

FlowFAST V. Vertical Laminar Airflow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Fume Hood Questions and Answers

Kompressoren. Adsorption Dryer AD

Chemical Fume Hoods. Environmental Health and Safety

Laminar Flow Cabinets and Workstations

Fume Extraction: Guide to Safely Managing Solder Fumes in the Workplace

Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health

CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG March 24, 2010

EMERGENCY VAPOR SCRUBBER SYSTEMS

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

Fume Cupboard Guidance

Range Equipment HVAC Design & Supply Modular Ranges

Spetec. Laminar Flow Box. Portable Clean Room Technology

Cooktop Low-Profile Ventilation Hoods

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Stainless Steel Worksurface 3 Feet Hood A10-WS-PR3 A10-WS-SR3 4 Feet Hood A10-WS-PR4 A10-WS-SR4 6 Feet Hood A10-WS-PR6 A10-WS-SR6.

National System of Garage Ventilation s Engineering Guide

HEPA FILTER DEFECTS ARE COMMON

There are several types of air cleaning devices available, each designed to remove certain types of pollutants.

Downflo workstation DuSt ColleCtorS

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

During Various Aluminum Fabricating Operations

Vacuum drying oven for non-flammable solvents

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

Standard Operating Procedure

Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard

HEPA-filtered Negative Air Machines and their Role in Creating Airborne Infection Isolation Rooms with the ECU AnteRoom. Frequently Asked Questions

How To Control A Medical Device With A Pc System

DOE-HDBK Module 2.18 Air Sampling Equipment. Instructor s Guide

a boiling point > 65 C

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

GenStore Archive Cabinet

3M Purification Inc. 3M Air Management Products for Your Commercial HVAC Needs. Create. Air. Confidence

6 Crankcase Ventilation

Robert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade

Installation, operation and maintenance manual TX 35A

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

FOR A CLEANER, HEALTHIER WORKING ENVIRONMENT

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

Cooling Capacity CFM in. w.c. (125 Pa)

Commercial Gas Furnace Upflow

Particularly Hazardous Substances (PHS) Standard Operating Procedure (SOP)

3M Personal Safety Division E C O R D. Cartridge. Filter. and. Guide. User Information to Help Optimize Protection

SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY

MATERIAL SAFETY DATA SHEET

HEALTHY CLIMATE HEPA BYPASS AIR FILTRATION SYSTEM READ AND SAVE THESE INSTRUCTIONS! AIR CLEANERS/ FILTERS

Ventilation Solutions Fresh Air Solutions for Ductless Heating & Cooling. fantech

SPILLS & SPILL KITS. Spills -General Guidelines:

Why and when to replace your 3M Filters!

PART 1 - INTRODUCTION...

Chapter 12 Industrial Ventilation

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

HVAC and pressurization. IECEx and ATEX

Compressed Air Filters

Procedures for the Effective Use of Biological Safety Cabinets

Ductless Systemss A COMFORTABLE, CONVENIENT SOLUTION BUILT TO A HIGHER STANDARD. READ ONLY

Low Voltage Transformers Sealed, General Purpose, Dry Type

For extraction technology and occupational health & safety

Guardian Fire Safety Solutions FIRE RISK CONTROL IN WELDING FUME EXTRACTION SYSTEMS

ORAY PREFABRICATED GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS

Fans That Sense & Extract Volatile Organic Compounds and Humidity

Spetec Laminar Flow Systems. Operating Instructions

Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories

Spray Booth Guideline

Environmental Monitoring

Series 18 Pass Thru Air Lock Cleanroom Entry System

Laboratory Ventilation Safety. J. Scott Ward

Evaluating Thermal & Catalytic Oxidation Technology for VOC, HAP & Odor Abatement. John Strey

INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER

Bulk Storage the OIL SAFE Way. Three System Types. Establish Best Practice

Modular Glovebox Systems Gas Purifier Units Antechambers Accessories

F9MXE. Product Specifications

NAVIEN AMERICA INC FITCH AVENUE

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

Mechanical Systems Competency 1.20

RUBBER SLEEVE KNIFE GATE VALVE

SPECIAL APPLICATIONS

DATA CENTERS. Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS

Filterfans. Air Flow data: PF 1000 PF 2000 PF 2500 PF 3000 PF 5000 PF 6000 PF 7000

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

How to use the Selection Guide

Guide on the Segregation, Packaging, Labelling and Storage of Laboratory Chemical Wastes for Schools

BENCH TECH 150. IVD In vitro diagnostic-medical device. General information Type of instrument: Bench chemical hood. Technical datasheet BenchTech150

SITE REQUIREMENTS AND INSTALLATION INSTRUCTIONS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Cleanroom Solutions Ltd T: F: E: W:

FDNY C14 Certificate of Fitness Quiz

EACO DOP / PAO TESTING GUIDELINE 2013

Flammable and Combustible Liquids. Slide 1 (of 23)

Safe Storage of Chemicals

Questions & Answers (Q & A) Regarding Asbestos Treatment with the Fire Suppression and Renovation Project

IEQ-15 Air Distribution System

Air Shower Biosafety Changing Station with Pass-Through Box Pass-Through Box Automatic atomizer for no-contact hand disinfection

Transcription:

Modular Ventilation and Filtration System Modular Ventilation and Filtration Systems for all Chemical Safety Cabinets. Vent-Box Shown on flammable safety cabinet; not included. Protection Against Chemical Inhalation Risks Without Expensive Energy Consuming Ductwork

p:2 Product Overview Modular Ventilation and Filtration System JUMP TO: Features and Callouts (p.3) Airflow and Multiplex Filtration Technology (p.4) Specifications (p.5) Options and Accessories (p.6) Ductless Filtration Systems Low-profile, completely portable, no ductwork required. Compact size, easily positioned on shallow safety cabinets. Modular design permits multiple configurations. Universal connections allow retrofit to almost all available flammable and safety cabinets on the market. Meets or Exceeds OSHA, ANSI, and other International Standards. Vent-Box. Shown on optional wall mount. INTRODUCTION Air Science Vent-Box ductless filtration APPLICATIONS Flexible cabinet ventilation for storage of: Flammable materials Acid / Corrosive chemicals Paints Pesticides Hazardous materials systems are designed to protect laboratory personnel from chemical vapors found inside of stand alone chemical safety cabinets. The Vent-Box serves as modular ventilation and a filtration system for all chemical safety cabinets. AIR SCIENCE MULTIPLEX FILTRATION TECHNOLOGY SYSTEM The Vent-Box utilizes the exclusive Air Science Multiplex filtration system, a unique configuration that includes a pre-filter and main filter to create a chemical, physical or combination architecture to adsorb, neutralize or trap the target chemicals or particulate. Fumes are pulled via a flexible hose connected to the cabinet and clean, filtered air is returned to the laboratory, eliminating the need for external ducting and minimizing loss of treated, conditioned air from the facility. MULTIPLEX SYSTEM FILTERS Pre-Filter. The electrostatic pre-filter protects the main filters from aerosols, dust and particulates with filtration efficiency superior to 95.5% down to 0.5 microns. Main Filter. Activated Carbon FILTCO sourced. A single carbon filter containing chemically-formulated activated carbon granules is selected when ordering to accommodate a specific vapor or family of vapors. HEPA Filter. A selfcontained Camfil-Farr HEPA filter is designed to physically capture particles larger than 0.3 microns. This Product Exceeds OSHA, ANSI and Other International Standards.

p:3 Product Features Modular Ventilation and Filtration System PRODUCT FEATURES: A. Filtration: Available with Multiplex filtration technology, a unique configuration that includes a pre-filter and main carbon filter. HEPA/ULPA filtration is also available. B. Hose: Each unit is provided with a PVC or metal flex hose with smooth inner surfaces to minimize pressure drop and friction loss. The vent hose is connected to the cabinet via a threaded 2" diameter (50.8 mm) metal bung adapter. The discharge end accommodates a 1.5" diameter (38.1 mm) metal or PVC hose. C. No-Tools Filter Access: The filter is easy to replace, no tools required. Simply open the easy access lid and change the filters. D. Multiple Connection Configurations: The Vent-Box comes equipped with four possible intake connections, allowing you to easily configure the unit to meet your space requirements. E. Exhaust Port: Slotted exhaust port allows for an optional bolt-on ducting collar that allows connection to existing in-house ductwork. F. Leveling Feet: Equipped with adjustable leveling feet that ensure solid placement on a variety of surfaces. G. Control Panel: Electronic controls and displays include switches for the blower and a low airflow alarm. Vent-Box. Top View Side View The Vent-Box is equipped with four intake hose connections, allowing for multiple configurations based on your space and layout requirements. One intake hose connection is located on either side of the Vent-Box top frame, with two connections located on the rear portion of the frame. Cover plates are available for the unused connection ports. Air Science 120 6th Street Fort Myers, FL 33907 T/239.489.0024 Toll Free/800.306.0656 F/800.306.0677 www.airscience.com

p:4 Product Filtration Modular Ventilation and Filtration System THE AIR SCIENCE PERFORMANCE ADVANTAGE Each Air Science Vent-Box includes features expressed through sound design and certified quality construction. Options and accessories add functional performance to meet specific applications. Professional Quality. Air Science products comply with current technical and safety regulations. Advanced Filtration. Air Science Multiplex filtration provides high performance protection. Industrial Components. The Vent-Box frame and outer surfaces are durable and chemically resistant. AIR SCIENCE CARBON FILTRATION Air Science carbon filters are based on enhanced, activated carbon particle formulations from naturally occurring raw material superior to wood or other organic sources. Our carbon is treated to attain the proper porosity and aggregate surface area, while reacting with several ranges of aerosolized chemicals moved through the filter by an air handling blower. The table below specifies the standard formulations of carbon available within our Multiplex Filtration Technology. VENT-BOX AIRFLOW PATTERN Fan/Blower Cabinet Air Intake Exhaust Air Filtration Electrostatic Pre-Filter Main Filters of carbon and/or HEPA/ULPA Reliability. Internal systems are isolated from contamination, extending product life. Vent-Box shown with Multiplex filtration system. The Vent-Box maintains a constant low velocity airflow through the cabinet. Contaminated air is pulled through the Multiplex filtration system where activated carbon adsorbs chemical vapors and/or particulates if HEPA/ULPA filters are used. Clean air is returned to the room. FILTER SUMMARY The Vent-Box uses energyefficient ebmpapst brand centrifugal blowers for long life and dependable performance. Formula GP Plus! ACI Plus! ACR ACM AMM SUL CYN FOR ETH HEPA/UPLA Description The most widely used filter in the range, primarily for solvent, organic, and alcohol removal. Designed to neutralize volatile inorganic acid vapors. Iodine and methyl iodide vapors. It is frequently used for iodination reactions with lower level radioactive iodine. Mercury vapor Removes vapors from dilute ammonia solutions and to remove low molecular weight amines. Designed to remove hydrogen sulfide and low molecular weight mercaptans. Removal of hydrogen cyanide. Many cyanide compounds will evolve HCN gas which acidifies, so this filter is normally specified if working with any cyanide compound. Designed to oxidize formaldehyde and glutaraldehyde fumes. It is widely used in hospital pathology laboratories. Diethyl ether is adsorbed on activated carbon, but because of its low boiling point, the local head adsorption can reduce the capacity of the filter. Special impregnation allows a chemical reaction which increases the filter capacity. Powders and particulates This Product Exceeds OSHA, ANSI and Other International Standards.

p:5 Product Specifications Modular Ventilation and Filtration System VENT-BOX DUCTLESS FILTRATION SYSTEMS FEATURES & BENEFITS The Vent-Box modular ventilation and filtration system is packed with features to make configuration and maintenance simple. The filter is easy to replace, no tools required. The filter clamps tightly against the filter gasket to maintain a positive seal and airtight connection. Ducting configuration is simple with locations for up to four input hose connections. The Vent-Box can be used as a ductless setup or can be ducted into an existing exhaust system with the optional ducting collar. The adjustable speed controller allows you to set the centrifugal fan motor speed as desired. Hose material options include PVC or metal for long lasting durability. Vent-Box Vent-Box Model Filter Weight Prefilter Weight Airflow Noise Construction Electrical Electrical Switches Monitoring Hose Left Side View MODEL DIMENSIONS WEIGHT (lbs/kg) (W x D x H) Shipping (W x D x H) Net Ship 21.25" x 12" x 13" 540 x 305 x 330 mm Specifications are subject to change without notice. Vent-Box PRODUCT SPECIFICATIONS 24" x 22" x 18" 610 x 559 x 457 mm 3 lbs/1.5 kg 1 lb/0.4 kg Factory set, 100 CFM; internally adjustable to 200 CFM <45 dba White epoxy coated steel 120v 60hz; 220v 50hz available, specify when ordering Main On/Off Low airflow alarm, standard Right Side View 32 / 14 34 / 15 PVC or metal, flexible. The vent hose is connected to the cabinet via a threaded 2" diameter (50.8 mm) metal bung adapter. The discharge end accommodates a 1.5" diameter (38.1 mm) metal or PVC hose. Compact size, easily positioned on shallow safety cabinets. Modular design permits multiple configurations. OPERATION MODES ROOM DUCT Universal connections allow retrofit to almost all available flammable and safety cabinets on the market. Meets or Exceeds OSHA, ANSI and other International Standards. MODE 1: ductless / filtered MODE 2: ductless / filtered with connection to in-house exhaust This Product Exceeds OSHA, ANSI and Other International Standards.

p:6 Product Options Modular Ventilation and Filtration System OPTIONS AND ACCESSORIES Filter Saturation Alarm and Electronic Hour Counter* An electronic gas sensor emits audio and visual alerts when the main filter needs to be changed. The option also includes an electronic hour counter to track unit run time. Polypropylene Construction Units available in all polypropylene construction. -PP FSA Color Match Ducting Collar Wall Mount Match the color of the Vent-Box unit to any type of chemical storage cabinet (Blue, Green, Red, Yellow). For connecting the Vent-Box to building exhaust for outside ducting. White epoxy coated steel shelf, specifically sized to hold the Vent-Box modular ventilation system. Mounting hardware not included. -BE -GN -RD -YW -EXH -WM -BE * Factory installed. Specify when ordering. -GN -RD -YW 120 6th Street Fort Myers, FL 33907 T/239.489.0024 Toll Free/800.306.0656 F/800.306.0677 www.airscience.com 2015 Air Science OW 10762 04/15 Air Science, Vent-Box, Multiplex, and EFT are all registered trademarks of Air Science Corporation