Design and performance of full-scale imbr plants treating winery wastewater effluents in Italy and Spain

Similar documents
e ROI Improved Membrane Bio-Reactor (MBR) performance delivers superior effluent quality and major capital savings at Latte Trento Dairy in Italy

MEMBRANE TECHNOLOGY TREATING OILY WASTEWATER FOR REUSE

Combination of advanced aeration system and membrane bioreactor for winery waste water treatment

Appendix 2-1. Sewage Treatment Process Options

Module 16: The Activated Sludge Process - Part II Instructor Guide Answer Key

Small Wastewater Treatment Systems

A NOVEL ION-EXCHANGE/ELECTROCHEMICAL TECHNOLOGY FOR THE TREATMENT OF AMMONIA IN WASTEWATER

ADVANCED LAGOON TREATMENT TECHNOLOGIES FOR WASTEWATER TREATMENT

Natural and Advanced Treatment Systems for Wastewater Management at Municipal Solid Waste Disposal Site in Developing Countries

Membrane Bioreactor Performance Compared to Conventional Wastewater Treatment

Oasis Clearwater ENVIRONMENTAL SYSTEMS WASTEWATER TREATMENT ENGINEERS

Best Practice Guide NO. BPGCS002. Wastewater Treatment Activated Sludge Process

Enhancing Nitrification in an Oil Refinery WWTP with IFAS

Membrane Filtration Technology: Meeting Today s Water Treatment Challenges

Experts Review of Aerobic Treatment Unit Operation and Maintenance. Bruce Lesikar Texas AgriLife Extension Service

HUBER Vacuum Rotation Membrane VRM Bioreactor

Phosphorus Removal in Wastewater Treatment

ACTIFLO Process For Wet Weather and Wastewater Treatment

Biological Wastewater Treatment

GRUNDFOS BioBooster. Cleaner water Greener environment

SMALL COMMUNITY TREATMENT PLANT EXPANSION WHILE IN OPERATION USING ADVANCED TECHNOLOGY

E nv i ro n m e nta l. Biotec 5-7. Sustainable, Reliable, Affordable

Rehabilitation of Wastewater Treatment Plant of Sakhnin City in Israel by Using Advanced Technologies

Sewerage Management System for Reduction of River Pollution

Nutrient Removal at Wastewater Treatment Facilities. Nitrogen and Phosphorus. Gary M. Grey HydroQual, Inc X 7167

SYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS

Amiad s AMF² pre-treatment technology ensures efficient and reliable nanofiltration of Scottish Highland loch water

DOMESTIC WASTEWATER SYSTEMS

Appendix F Use of spill basin to further reduce final effluent variability - report


Development of Advanced Wastewater Treatment and Reclamation System

Advanced Wastewater Treatment and Disposal Systems. Water and Wastewater Utility Operation and

aquateam Aquateam - Norwegian Water Technology Centre A/S Report no: Project no: O Project manager: Dr. Bjørn Rusten.

WASTEWATER TREATMENT OBJECTIVES

A Guide to Specifying Reed Beds and Constructed Wetland Systems

NUTRIENT REMOVAL WASTEWATER TREATMENT CLIFFORD W. RANDALL, PHD EMERITUS PROFESSOR VIRGINIA TECH

PROPAK AquaBio Complete Water Restoration Systems

Small scale sewage treatment system with membrane bioreactor technology

Biological Phosphorus Removal Activated Sludge Process in Warm Climates

CHAPTER 8 UPGRADING EXISTING TREATMENT FACILITIES

COD/BOD 5 Reduction with ROTAMAT Fine and Micro Screens

1.85 WATER AND WASTEWATER TREATMENT ENGINEERING FINAL EXAM DECEMBER 20, 2005

Saudi Aramco Project Development

Holistic Aeration and Chemical Optimization Saves Big Money from 1 MGD to 600 MGD. Trevor Ghylin, PE PhD

OPTIMIZING BIOLOGICAL PHOSPHORUS REMOVAL FROM AN SBR SYSTEM MIDDLEBURY, VT. Paul Klebs, Senior Applications Engineer Aqua-Aerobic Systems, Inc.

WEFTEC.06. *Corresponding author Department of Civil and Environmental Engineering, The University of Western Ontario

Module 17: The Activated Sludge Process Part III

THE MARSHALL STREET ADVANCED POLLUTION CONTROL FACILITY (CLEARWATER, FLORIDA) CONVERSION TO 4-STAGE BARDENPHO TO IMPROVE BIOLOGICAL NITROGEN REMOVAL

Example Calculations Evaluation for Fine Bubble Aeration System. Red Valve Company, Inc. 700 NORTH BELL AVENUE CARNEGIE, PA

Membrane Bioreactors (MBR) for Municipal Wastewater Treatment An Australian Perspective


Evaluation of water stress of selected cases from water re-use or saving scenario s tested in SP5

Water Recycling in action in South Australia: a review of agricultural and municipal reuse schemes and innovation.

SECONDARY TREATMENT ACTIVATED SLUDGE

Phosphorus Removal. Wastewater Treatment

4.2 Option 1 Expand Existing Lagoon System

Collection and disposal of wastewater

Table 1.1: Typical Characteristics of Anaerobically Digested Wastewater

Planning, Designing, Monitoring and Inspection of Wastewater Treatment Systems of Industries

GUIDELINES FOR LEACHATE CONTROL

WASTE WATER TREATMENT SYSTEM (OPERATING MANUALS )

grundfos biobooster Biobooster cleans up in Norwegian municipality

Compact Sewage Systems in France A technical and cost comparison

WISCONSIN WASTEWATER OPERATORS ASSOCIATION

THE NEW NSF 350 AND 350-1

Advanced Wastewater Treatment Process

Iowa DNR Wastewater Treatment Technology Assessment No

Removing Heavy Metals from Wastewater

CONDENSED CATALOG

MEMCOR membranes for drinking water applications. Water Technologies

Aerated Wastewater T r eatment System

Operation and Maintenance of Onsite Waster Systems in Maryland. A growing challenge for the industry and regulators

Troubleshooting Your RO

Nine Industrial Scale V SEPs. Feed Tank V SEP. Feed Pumps (Three) Concentrate. Tank. V SEP Treatment System

ADDENDUM TO THE FACT SHEET FOR NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) PERMIT NO. WA June 25, 2010

During the past decade, the city of

Viledon Water Solutions for energy-efficient water and wastewater treatment and reuse

MODELING WASTEWATER AERATION SYSTEMS TO DISCOVER ENERGY SAVINGS OPPORTUNITIES By Steven A. Bolles Process Energy Services, LLC

Sewage and Wastewater Odor Control Dr. Giancarlo Riva, Ozono Elettronica Internazionale, Muggio, Italy

Wastewater Nutrient Removal

Brewery Wastewater: 2010 Water and Wastewater Conference Page 1

Facility Classification Standards

Overview of Best Available Technologies for Onsite Septic Systems and Management Considerations Presentation to NAHB

Chemistry at Work. How Chemistry is used in the Water Service

Report Naga City: Septage treatment and wastewater concept for Del Rosario

ECOAZUR BLUEWATER WATER PURIFICATION PLANTS

Six Municipalities, One Watershed: A Collaborative Approach to Remove Phosphorus in the Assabet River Watershed

grundfos biobooster NEXT-GENeRATION WASTEWATER TREATMENT

Products, systems and services for water and wastewater treatment plants Enhanced plant performance, efficiency and reliability

Fusion Series Treatment Systems Small Scale Residential & Commercial Treatment Units

Flexible Microscreen Filter. Hydrotech Discfilter

6.2 ADVANCED WASTEWATER TREATMENT PROCESS PERFORMANCE

QuickCODultra. Online COD for every kind of water. Especially for the rough stuff. Fast. Precise. Reliable. COD-ANALYSis

A HOMEOWNERS GUIDE ON-SITE SEWAGE MANAGEMENT SYSTEMS

MALAYSIA S REQUIREMENTS ON INDUSTRIAL EFFLUENT TREATMENT SYSTEMS -The WEPA Workshop and Annual Meeting February 2013 Siem Reap, Combodiaby

PERFORMANCE TESTING OF A 380 ML/D RETROFITTED MEMBRANE/UV OXIDATION WTP. Introduction

PRODUCT SELECTOR Pollution Control, Pumping and Rainwater Harvesting Systems

Provided below is a description of the processes generating wastewater in a poultry plant and a typical pretreatment and full treatment system.

OPTIMIZING PHOSPHORUS REMOVAL BY CHEMICAL ADDITION AT ORADEA WASTEWATER TREATMENT PLANT

BIODISC HIGH PERFORMANCE SEWAGE TREATMENT PLANT FOR DOMESTIC APPLICATIONS

Transcription:

Design and performance of full-scale imbr plants treating winery wastewater effluents in Italy and Spain V. Ferre*, A. Trepin **, T. Giménez***, S. Lluch *** * Kubota Membrane Europe Ltd., 8 Hanover St, London W1S 1YE, UK (E-mail: victor@kubotalon.co.uk) ** Ladurner Acque Srl, 33 Via Innsbruck, Bolzano 39100, Italy (E-mail: Andrea.Trepin@ladurner.it) *** HERA-AMASA, S.A. Grupo HERA, Area Tecnologías - Dep. Aguas, 6, Paletes - Parque Tecnológico del Vallés, Cerdanyola 08290, Spain (E-mail: toni.gimenez@heraholding.com; sergi.lluch@heraholding.com) Abstract This paper provides an overview of full-scale immersed membrane bioreactor (imbr) technology applied to Mediterranean wineries. It is based on the cumulative experience on design, commissioning and operation of 8 Spanish and 13 Italian references from 2003 to present day. In all of them Kubota membranes are employed. Market drivers for this treatment technology in the wine industry and comparison with alternatives are presented. The text covers wastewater characterization and flow patterns, different flowsheet configurations and pretreatments, favoured biological conditions and membrane flux, common troubleshooting experiences and also running costs. In plants where reuse initiatives have been undertaken, feedback on water quality and potential uses are explained. Keywords Design; immersed membrane bioreactor; performance; reuse; winery INTRODUCTION Kubota imbr in Europe Over the last 10 years, Immersed Membrane Biological Reactor (imbr) technology has been gradually adopted in Europe for both municipal and industrial applications. At the time of writing this paper, the first municipal experience in Porlock (UK) and the first industrial site (a dairy wastewater treatment plant in the Republic of Ireland) were still running with their original Kubota membranes from 1998 and 1999 respectively. At the end of 2008, Kubota could claim near 400 imbr plants in Europe from which approximately 60% were industrial. Food and beverage industry accounted for 45% of the industrial references, and the largest contributor to this category was Wineries. Kubota imbr in Mediterranean wineries All 22 European Kubota imbr winery references were located in Italy (14) and Spain (8). The first reference was built in 2003 and the last two at the time of this paper in 2008. Design average flows ranged from 14m 3 /day to 200m 3 /day to a total average treatment capacity of 1,260m 3 /day. The wineries equipped with Kubota imbr were as per Table 1. 1

Table 1. Kubota imbr references in European wineries Customer Country Av design flow (m 3 /d) Commissioning Year BV Spain 19 2003 CS Spain 14 2004 MC Spain 15 2004 Z Italy 30 2004 DV Spain 75 2004 JS Spain 80 2004 C Italy 17 2004 VA (I) Italy 80 2004 C Italy 18 2005 SM Spain 43 2005 R Italy 50 2005 F Italy 110 2005 CS Italy 60 2005 VA (E) Spain 30 2007 SS Italy 40 2006 GC Italy 80 2007 C (2) Italy 26 2007 V Italy 100 2007 PP Italy 200 2007 SU Spain 60 2007 F (2) Italy 34 2008 F (3) Italy 140 2008 Although discharge limits could become tighter in the future, at the time of writing this paper both Spain and Italy enjoyed relatively loose standards that could be met with a wide array of technologies in most cases winery wastewater treatment plants (WWTP) discharged into municipal sewerage collectors. Spanish discharge limits were 160mg/L for COD, 40mg/L for BOD 5 and 5 or 80mg/L for SS, with no mention to pathogens. Hence, drivers for imbr technology in winery applications had to be found elsewhere: scarce available space, capacity enlargement of conventional treatment plants, minimisation of visual and odour impact, need for reduced civil 2

engineering, treated effluent reuse for on-site cleaning or irrigation, etc. DESIGN ASPECTS Some of the challenges for the design of a WWTP using biological digestion are variable loads (daily and seasonal), and lack of nutrients. Particular problems for membrane filtration systems are presence of solids. Pre-treatment Winery effluents have presence of easily decantable suspended solids such as seeds, tartaric salts and/or filtration media (Flanzy, 2003). MBR plants generally do not have gravity settling tanks, hence in order to avoid abrasion problems with grape seeds circulating between the membranes, it is preferable to install a 1mm screening at the head of works. It is crucial to avoid screen by-passes with sound designs especially during high flow events. Equalization or balancing tank Even during the grape harvest, there are considerable fluctuations in flow and organic load. Therefore it is commonly accepted that a WWTP shall be supplied with appropriate equalization capacity. Kubota imbr designs in Spain were provided with 24 hours equalization volume at peak flow conditions. ph is typically acidic, usually lower than 5, with punctual alkaline episodes due to the usage of chemical products for cleaning the tanks (Flanzy, 2003). Because equalization tanks are usually aerated and part of the waste sludge is sent there, ph neutralization at the equalization tank prior to the biological treatment can contribute to remove part of the organic load. Even without sludge seeding, aeration can help to reduce COD due to stripping of volatile compounds. Biological treatment Nutrient deficit. High BOD 5 /TN and BOD 5 /TP ratios (Flanzy, 2003) mean there is a need to dose N and P as to complete biological digestion. For WWTP imbr systems, nutrient addition was in the form of urea and phosphoric acid, dosed at the balancing tank with either automated dosing pumps or, more often, manually. BOD 5 levels were reduced to below 25 mg/l at the effluent. Seasonality. According to Flanzy (2003) 60-70% of the total effluent is produced during the 3 months following harvesting, that is towards end of summer and autumn in the northern hemisphere. Spanish experience shows that grape harvest period can last for two or three months, and approximately half of the flow and 80% of the total organic load of the year are produced in this period. In Table 2, the combined effect of higher pollutant concentrations and flows in August implied organic loads factored by 11, 2.6 and 3 for BOD 5, TN and TP respectively, as compared to January. Most organic load was soluble, therefore the variations affected directly to the biological dimensioning and could not be minimized with a strong mechanical pre-treatment. 3

Table 2. Inlet wastewater characterization at an Italian winery WTP. Jan-07 Aug-07 Flow m 3 /h 15 44 TSS mg/l 536 780 COD mg/l O 2 1,327 3,978 BOD 5 mg/l O 2 610 2,295 TN mg/l 36 32 TP mg/l 7 7 Temperature dc 12 22 ph 7.71 10.10 Membrane filtration system Dimensioning of membrane systems needs to be optimized in order to be economical. Also, it has to be flexible enough to cope with average flows that differ by a factor of 3 between harvesting season and low season. Design flux is dependent on liquor temperature, viscosity and sludge conditions. It is therefore advisable to perform a pilot test to determine the optimal plant design. Table 3 shows examples of flux in some Kubota imbr plants. Table 3. Flux designs for Spanish WWTP. Membrane area Peak Flux Average Flux Reference m 2 m 3 /m 2 /d m 3 /m 2 /d BV 60 0.76 0.33 DV 240 0.75 0.3 JS 240 0.80 0.3 MC 40 0.90 0.38 Ancillary equipment Kubota imbr process uses dedicated duty blowers for nitrification and membrane cross-flow filtration, and one additional standby blower for both purposes. PLC control loops would stop the plant upon membrane blower failure. Permeation pumps (which are optional given that Kubota imbr can filter by gravity) are also doubled as duty-standby. In certain plants, aeration and suction systems were supplied with frequency inverters for further economies. Permeation pumps were controlled by level transmitters at membrane tanks. Configurations The Kubota imbr references taken in this analysis confronted seasonality in three different ways: Hybrid, Modular and Buffered Compact plants. Hybrid MBR plant. Winery F(3) in Italy was a retrofit over a previously existing conventional activated sludge plant. In 2008 the plant capacity was enlarged by converting part of the treatment line into imbr. At the head of works there was an equalization tank from which the influent could take 3 different routes: a small-scale imbr for low load season (retrofitted in the old denitrification tank, Fig. 1 Left), a large-scale imbr for high load season (retrofitted in one nitrification tank, with membranes inside the old clarifier, Fig. 1 Right) and an old non-modified nitrification tank with its clarifier for emergencies. The new imbr plant during low season used 4

less than 1/3 of the volume of the past, thus substantially reducing power consumption. Fig. 1. (Left) imbr plant for Low Load operation. (Right) imbr plant for High Load operation. Modular imbr plant. Winery DV in Spain was a new-construction plant (Fig. 2 Left). An equalization tank provided enough volume for a hydraulic retention time (HRT) of approximately 1 day in peak flow regime. In order to adjust the biological reactor volume to the different operating conditions, there were two pre-aeration reactors which could operate alternatively or simultaneously. During low season one reactor was maintained running and the other was emptied for servicing. During harvesting season both reactors would run in parallel. A single membrane tank would operate all year-round regardless the hydraulic load (Fig.2 Right). Membrane surface area was dimensioned for harvesting peak load, therefore during low season membranes would filter for a reduced amount of time. Fig 2. (Left) Modular imbr plant under construction. (Right) Kubota Submerged Membrane Units. Buffered Compact imbr plant. Small wineries in Spain with little available footprint were designed this way. Following a generous equalization tank, a single membrane tank provided enough volume for complete biological digestion during peak season. The reactor volume was constant. Having the same reactor volume for all operating conditions would oblige to operate at variable HRT and SRT throughout the year. During low season, lower purging frequency and lower F:M ratio would mineralize the sludge. Specific aeration requirements in low season would certainly be less optimized than for other more flexible design flow sheets such as a hybrid or modular imbr plants (Fig. 3). 5

Fig. 3. Two examples of buffered compact imbr plants in Spanish wineries. PERFORMANCE Process stability imbr proved adaptable to different loads from a biological point of view. Episodes of viscous bulking happened as a result of sudden increases of the organic load, where nutrients were not dosed. Despite poor sludge condition or bulking, no biomass would be lost in membrane systems. Sludge production was believed 0.3kg MLSS/kg BOD 5 although there was no return on experience on this. Long sludge ages were estimated to reduce VSS/MLSS ratio down to 60%, however sludge filterability always remained acceptable. It was important that during peak flows the membrane system performed well. It might be necessary to carry out chemical cleans before harvesting flows entered the plant. Cumulated experience showed that chemical cleans occurred every two to six months (depending on the season) and permeability was typically fully recovered. The chemical used for membrane cleaning was sodium hypochlorite at 0.5% by weight concentration. Simplicity of operation and maintenance are important for industrial wastewater plants which often are not sufficiently manned. Kubota imbr allows for operation at higher MLSS concentrations than other systems as successfully run for extended periods above 20g/L. This is a useful feature when there is not a frequent control on sludge purges. Effluent quality and reuse Kubota imbr effluent quality was consistently compliant with the usual discharge consents for wineries at the time of writing this paper. Also, it suited a number of reuse applications as stated in national and international standards. Two of the assessed plants in Spain reused their effluents for crop irrigation, with COD in the range 50 300mg/L, BOD 5 <10mg/L and SS<2mg/L. Depending on the reuse application and local regulations it may be necessary to provide additional safety barriers such as UV or residual chlorine disinfection. 6

Cost trends against conventional biological systems Civil. imbr could be very cost-effective to retrofit in existing plants, as treatment capacity would improve in both quality and flow within the old footprint. Energy. It is accepted that power consumption for municipal imbr is higher than similar activated sludge processes due to the aeration required to generate a crossflow effect on the membranes. The energy consumption difference between a conventional activated sludge process and imbr in wineries should be minor than in municipal applications based on the kg BOD 5 removed / m 2 membrane filtration area ratio. In other words, higher influent concentrations help towards imbr economical viability. Chemicals. imbr process is arguably less sensitive to filamentous bacteria than conventional systems, given that there is no exposure to sludge settleability. In addition to this, longer sludge age contributes towards sludge stabilization. It was believed that these facts would have a positive impact on the cost of sludge conditioning, however there were no field data available to back this up. Operational problems and membrane replacement rates Operational problems. Given the non-productive nature of industrial wastewater treatment plants it is often found that operation and maintenance are insufficient. Staff may not be properly trained or motivated for the correct operation of such process plants. In addition to this, equipments may not be used in the way they were designed for and there is little or no operational feedback nor preventive maintenance nor requests for technical assistance. Samples are taken very seldom and process checks such as sludge characterization tests are never performed. The most common sludge-related problem was bulking, which causes could be various: deficient ph adjustment due to dirty electrodes, nutrients were not added when needed or were dosed in the wrong proportion, fluctuations in organic loads, which happened because the equalization tank s level was kept too low. Apart from sludge bulking, other reasons for poor membrane filtration were either control-related blower failures or presence of harmful substances: diffuser flushing deactivated from the PLC, which eventually caused uneven cross-flow filtration and clogging. Full permeability recovery was achieved after physical and chemical cleaning, PLC did not detect blower failure. The effect was membrane dead-end filtration and severe membrane clogging. Full permeability recovery was achieved after physical and chemical cleaning, usage of silicon-based antifoaming agents which damaged the membranes, presence of diathomea sand (used to filter wine) which required manual cleaning of the membranes. Afterwards full permeabillity recovery was 7

achieved. Replacement rates. At the time of writing this paper, total replacement of Kubota cartridges for the European winery industry corresponded to 1.6%. In actual fact, only one winery had required membrane replacements and that was due to improper use of foaming control agents which caused irreversible damages on the membrane surface. CONCLUSION Kubota membranes for imbr have been successfully applied in 22 European winery wastewater treatment plants since 2003. The experience to-date shows imbr as a reliable solution for the wine industry offering easy retrofit to existing plants, flexibility against seasonality, process stability, high effluent quality and possibility to reuse the treated effluent. Main operational problems were identified and were considered avoidable with good design and operator s training. Kubota s membrane replacement rate across the European wineries was less than 2% of the total installed at the time of writing the paper. BIBLIOGRAPHY Flanzy, C. (2003). Enología: Fundamentos Científicos y Tecnológicos. AMV Ediciones, Mundi-Prensa 8