POROTHERM CLAY BLOCK FIXING GUIDE

Similar documents
fischer Test Report Fixing Tests for Wienerberger Porotherm blocks

HUS-HR, CR Screw anchor, stainless steel

HUS-A 6 / HUS-H 6 / HUS-I 6 / HUS-P 6 Screw anchor in precast prestressed hollow core slabs

Injection System VMU. Injection System for non-cracked concrete and brickwork. Threaded Stud VMU-A for concrete and brickwork

Bonded Anchors & Mechanical Anchors

TECHNICAL INFORMATION

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

HSL-3 Heavy duty anchor carbon steel. Anchor Fastening Technology Manual HSL-3. Heavy duty anchor. Version /

HUS-V Screw anchor. HUS-V Screw anchor. Basic loading data (for a single anchor) Mean ultimate resistance

High-performance, 2-part epoxy anchoring adhesive

HUS-HR, CR Screw anchor, stainless steel

Hilti HIT-HY 200 with rebar

Power Tools for Professionals

(English language translation, the original version is in French language) SPIT HIT M. Société SPIT Route de Lyon F BOURG-LES-VALENCE France

Hilti HIT-HY 150 MAX with rebar

HUS-HR Stainless steel Concrete Screw A CE conformity. Corrosion resistance. European Technical Approval

ELECTRIC PERISTALTIC MORTAR POINTING PUMP

Poro Lintel System Range Unique to the Porotherm & thin joint masonary systems

ICC-ES Evaluation Report

TZ WEDGE ANCHOR FOR CRACKED AND UNCRACKED CONCRETE

PC-Concrete Injectable Concrete Anchoring and Repair System

Connection Solutions

HVU with HAS/HAS-E rod adhesive anchor

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

CORDLESS TOOLS. People. Passion. Performance. FOR AUTOMOTIVE AND MAINTENANCE PROFESSIONALS

4 X 1 3/8 X 3/16 CHANNEL x 34.9 x 4.8 CHANNEL

Seismic Installation for Attic Storage System

7Čå.e.279(1Ì HEAVY DUTY ANCHOR

Drilling and Demolition

Hilti, Inc South 122 nd East Avenue Tulsa, OK

SMART PLUG TYPE BP AND LBP

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Pure Performance. Steady 1300 Series

Step by Step instructions How to screw in wood and plastic

The Effects of Hole Cleaning on Post-Installed Anchor Systems in Concrete

BUMAX. REYHER your partner for the BUMAX range

Hilti, Inc South 122 nd East Avenue Tulsa, OK

Technical Application Document. Hilti HIT-RE 500-SD

Sump Systems for Basements

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.

Handrail & Balustrade Solutions. when only the best will do...

172 Holesaws Overview Bosch Accessories for Power Tools 09/ Diamond holesaw. with Power-Change adapter. 190 Diamond drill bits

Integrated Manhole Ladder System

Submittal Information

Supplier ID: Local Office: GLASGOW 69 Buchanan Street Glasgow G1 3HL

Rollers. from the UK s largest roller manufacturer. Quality Performance Reliability

HUS-H Screw Anchor. Technical data. Seismic design data. HUS-H Carbon steel screw anchor. HUS-H diameter 8, 10, 14. Seismic design data

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

European Technical Approval ETA-13/0235

Samuel Shorty Bunk Bed

CORDLESS SCREWDRIVER + LAMP

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

RELAZZO DECKING THE TERRACE. INSTALLATION GUIDE. Construction Automotive Industry. REHAU R20680 EN

Horizontal Anchorage Device

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

Accessories for GF and RA machines

Ermächtigt u n d n o t i f i z i e r t gemäß Artikel 10 der Richtlinie des Rates vom 21. Dezember 1988 zur Angleichung

Baumann Flexsleev Sanitary Control Valve

MASONRY SUPPORT & WINDPOST SYSTEMS

Customer Service or visit us online at smithnoble.com. Wood Shutters. Step by Step Installation. Troubleshooting Tips

Guidelines for Earthquake Bracing of Residential Water Heaters

Hilti HIT-V and HAS Threaded Rod and Hilti HIT-Z Anchor Rod

Permanent Stainless Steel Anchorage Point for Concrete, Solid Masonry and Steel Constructions

Internal Basement Waterproofing Newton System 500

ANCHOR BOLTS FOR NUCLEAR POWER PLANT APPLICATIONS

Installation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale

Thor Helical Remedial

Machine devices, jig devices

BARRIER LIFT SYSTEM 2 BARRIER LIFT SYSTEM

Pipe Cutting and Beveling Clamshells

Scepter PVC Molded Junction Boxes

European Technical Approval ETA-12/0500

The EJOT. Fastener. Predictable performance improvement for thermoplastics. EJOT The Quality Connection

Awning Instructions. Standard Manual 1.5m to 4.5m

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Specifying higher-quality durable power tools

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Pay and Display Ticket Machines

Hilti KWIK HUS-EZ I (KH-EZ I) Internally Threaded Carbon Steel Screw Anchor

Fish Grader User Manual

Canvas Office Landscape Wall Strip Installation and Disassembly for Recycling Instructions

Electric Rotary Actuator - On/Off or programmable control actuator

FLOORS REINFORCEMENT Shear Stud Connector for steel- concrete composite structures cold applied by pins

DRILLS MODEL DESCRIPTION PART NO. M.R.P.

SPECIAL OFFER AUTUMN 2015

SAFETY AND OPERATING MANUAL. Cordless rotary hammer WX382 WX382.1 WX382.2 WX382.3

swimming pool accessories

The right solutions. However, it is inevitable that with the introduction of any new construction system the question arises How does it compare?

Guide rail bracket (for adjustable heads)

English translation prepared by DIBt Original version in German language

CITY OF LOS ANGELES CALIFORNIA

Europeiskt Tekniskt Godkännande European Technical Approval

SDS PLUS 4 Claw (4 Cutting Edges) SDS-Plus

PART E SPECIFICATIONS

Protecting what matters

Awning Instructions. Full Cassette 1.5m to 6m

Transcription:

POROTHERM CLAY BLOCK FIXING GUIDE

UK: 0800 731 4924 SPIT An Introduction Spit products offer a complete range of solutions for fixing components into steel and concrete. Founded in 1949 when a unique system for fixing into these materials was invented (now generally known as cartridge or powder actuated tools: PAT), the past 60 years has seen Spit develop a variety of technologies for fixing on the construction site including - direct fixing, drilling and anchoring. As part of the multi-billion dollar organization ITW - Illinois Tool Works Inc, Spit has access to almost 100 years of experience in the design, development and manufacture of fasteners and components, equipment & consumable systems across the world. With permission from Wienerberger, the world s largest manufacturer of clay blocks, this guide has been produced in order to promote best fixing practices when installing a specialist range of Spit Chemical and Nylon Anchors to Porotherm Blocks and to provide an outline of performance data. This document is intended as a guide only. For detailed, project specific installation or technical advice users should always refer to SPIT for guidance. Technical Services In the UK & Ireland the Spit Technical Services Team is always on hand to provide on or off site support when you need it most and have offered advice on a variety of high profile projects including Heathrow Terminal 5, Wembley Stadium and the Emirates Stadium. Our highly trained personnel are able to provide support at all stages of the design and construction process from Specification Advice through to onsite testing and installation training. In addition to the technical services on offer we also have a wide range of literature to help you select the best products for your applications. Contact the Technical Helpdesk for information on the Product Guide, Fixings Design Guide or Spit i-expert Calculation Software.

ROI: 1 800 882 388 POROTHERM CLAY BLOCK Offering exceptionally fast, virtually dry construction, plus high strength and thermal efficiency, Porotherm is a modern clay block structural walling system with reassuringly traditional values. A natural progression from hand made bricks to engineered blocks; it is widely used and has been proven on millions of projects for over 30 years in Europe in both domestic and commercial applications, and is ideal for use on projects from single storey to multiple-storeys. Porotherm is a highly efficient alternative to other building materials such as timber, concrete or light steel frames and is suitable for a variety of construction applications. SPIT ANCHORS TESTED SPIT ID-ALL Hollow Material Fixing System With C-MIX PLUS Polyester Resin and Stud SPIT NYLON SLEEVE Hollow Material Fixing System With EPOMAX Vinylester Resin and Stud SPIT PRO 6 Universal Nylon Anchor SPIT HIT M Hammer Screw Anchor SPIT PROLONG Nylon Frame Anchor Also available in Stainless Steel for outdoor applications Countersunk Torx Screw Hex Head Screw SPIT W-TECH Cavity / Hollow Wall Anchor Tests were undertaken at the CERAM Laboratories in Stoke-on-Trent in October and November 2011, Report 114495/Ref:1.0A refers, and at the Wienerberger Plant in Cheadle in April 2011. Tensile Values were ascertained in accordance with ETAG 001 Annex A clause 5.2.1. Combined Tension and Shear Values were ascertained in accordance with ETAG 001 Annex A clause 5.4 and are representative of a load supported 150mm off the face of the wall and 600mm below the anchor.

UK: 0800 731 4924 TEST RESULTS - INSTALLING SPIT ANCHORS INTO POROTHERM BLOCK AXIAL TENSION LOADS The following results have been derived from Ultimate failure values N Ru and factored recommended values N Rec and N Rec2 Recommended loads are derived from Mean Ultimate values, with the appropriate safety factors applied, which is anchor specific. For chemical anchors, a safety factor of 4:1 is applied. As nylon anchors are subject to higher levels of creep, a higher safety factor of 7:1 is applied. POROTHERM 100 AND 140 BLOCK Spit Anchor Tensile Load N Rec Tensile Load Range Spit Hit M M6 x 30mm A4 0.14 kn up to 15 kg Light Duty Spit Pro 6 8 x 40mm + ProScrew 0.21 kn up to 20 kg Light/Medium Spit Pro 6 10 x 50mm + ProScrew 0.30 kn up to 30 kg Light/Medium Spit id-all, C-Mix Plus Resin & M10 x 135mm Stud* 0.92 kn up to 95 kg Heavy Duty Spit Plastic Sleeve 20 x 85mm, Epomax Resin & M10 x 130mm Stud 2.15 kn up to 220 kg Heavy Duty POROTHERM 190 BLOCK Spit Anchor Tensile Load N Rec Tensile Load Range Spit Pro 6 8 x 40mm + ProScrew 0.21 kn up to 20 kg Light/Medium Spit W-Tech 8 x 40mm + 5mm Bolt 0.23 kn up to 23 kg Light Duty Spit Prolong 8/10-80 7 x 85mm Torx Screw 0.29 kn up to 30 kg Medium/Heavy Spit Prolong 10/10-80 6 x 85mm Hex Screw 0.36 kn up to 37 kg Medium/Heavy Spit id-all, C-Mix Plus Resin & M10 x 135mm Stud* 0.75 kn up to 76 kg Heavy Duty Spit Plastic Sleeve 20 x 85mm, Epomax Resin & M12 x 160mm Stud 3.22 kn up to 325 kg Heavy Duty POROTHERM 365 BLOCK Spit Anchor Tensile Load N Rec Tensile Load Range Spit W-Tech 8 x 40mm + 5mm Bolt 0.11 kn up to 11 kg Light Duty Spit Pro 6 8 x 40mm + ProScrew 0.12 kn up to 12 kg Light/Medium Spit Prolong 8/10-80 7 x 85mm Torx Screw 0.29 kn up to 30 kg Medium/Heavy Spit Prolong 10/10-80 6 x 85mm Hex Screw 0.30 kn up to 30 kg Medium/Heavy Spit id-all, C-Mix Plus Resin & M10 x 135mm Stud* 0.96 kn up to 100 kg Heavy Spit Plastic Sleeve 20 x 85mm, Epomax Resin & M12 x 160mm Stud 2.91 kn up to 295 kg Heavy

ROI: 1 800 882 388 TEST RESULTS - INSTALLING SPIT ANCHORS INTO POROTHERM BLOCK COMBINED SHEAR & TENSION LOADS The following results have been derived from Ultimate failure values N Ru and factored recommended values N Rec and N Rec2 Recommended loads are derived from Mean Ultimate values, with the appropriate safety factors applied, which is anchor specific. For chemical anchors, a safety factor of 4:1 is applied. As nylon anchors are subject to higher levels of creep, a higher safety factor of 7:1 is applied. POROTHERM 100 AND 140 BLOCK Combined Shear & Combined Shear & Spit Anchor Tension Load N Rec2 Tension Load Range Spit Pro 6 8 x 40mm + ProScrew 0.20 kn** up to 20 kg** Light/Medium Spit id-all, C-Mix Plus Resin & M10 x 135mm Stud* 0.92 kn** up to 95 kg** Heavy Duty Spit Plastic Sleeve 20 x 85mm, Epomax Resin & M10 x 130mm Stud 2.15 kn up to 220 kg Heavy Duty POROTHERM 190 BLOCK Combined Shear & Combined Shear & Spit Anchor Tension Load N Rec2 Tension Load Range Spit Pro 6 8 x 40mm + ProScrew 0.30 kn up to 30 kg Light/Medium Spit Prolong 8/10-80 7 x 85mm Torx Screw 0.34 kn up to 34 kg Medium/Heavy Spit Prolong 10/10-80 6 x 85mm Hex Screw 0.70 kn up to 70 kg Medium/Heavy Spit id-all, C-Mix Plus Resin & M10 x 135mm Stud* 1.00 kn up to 100 kg Heavy Duty Spit Plastic Sleeve 20 x 85mm, Epomax Resin & M12 x 160mm Stud 2.94 kn up to 295 kg Heavy Duty POROTHERM 365 BLOCK Combined Shear & Combined Shear & Spit Anchor Tension Load N Rec2 Tension Load Range Spit Pro 6 8 x 40mm + ProScrew 0.12 kn up to 12 kg Light/Medium Spit Prolong 8/10-80 7 x 85mm Torx Screw 0.33 kn up to 33 kg Medium/Heavy Spit Prolong 10/10-80 6 x 85mm Hex Screw 0.63 kn up to 63 kg Medium/Heavy Spit id-all, C-Mix Plus Resin & M10 x 135mm Stud* 1.03 kn up to 103 kg Heavy Duty Spit Plastic Sleeve 20 x 85mm, Epomax Resin & M12 x 160mm Stud 2.74 kn up to 275 kg Heavy Duty * Contrary to accepted anchor installation practice in conventional masonry, installation of id-all anchors into the perpendicular joints of Porotherm masonry will produce a 50% enhancement of the anchor tensile capacity. ** Values interpolated from 190mm Combined Shear & Tension Tests.

UK: 0800 731 4924 EQUIPMENT USED TO INSTALL SPIT ANCHORS Spit Anchor Drill Used Drill Bit Used Other Equipment Used Spit id-all, C-Mix Plus Spit 245 IDI 16mm Ø Masonry Drill Bit Injection Tool, id-all Nozzle, & M10 x 135mm Stud Wire Brush, Blow-out Pump Spit Plastic Sleeve 20 x 85mm, Epomax Spit 245 IDI 20mm Ø Masonry Drill Bit Injection Tool, Nozzle, Wire Brush & M10 x 130mm Stud Blow-out Pump Spit Plastic Sleeve 20 x 85mm, Epomax Spit 245 IDI 20mm Ø Masonry Drill Bit Injection Tool, Nozzle, Wire Brush & M12 x 160mm Stud Blow-out Pump Spit Pro 6 8 x 40mm Spit 245 IDI 7mm Ø Masonry Drill Bit (40mm embed) - Spit Pro 6 10 x 50mm Spit 245 IDI 10mm Ø Masonry Drill Bit (50mm embed) - Spit Hit M M6 x 30mm Spit 245 IDI 6mm Ø Masonry Drill Bit (25mm embed) - Spit Prolong 8/10-80 Spit 245 IDI 8mm Ø Masonry Drill Bit T30 Bit for Torx Head Spit Prolong 10/10-80 Spit 245 IDI 10mm Ø Masonry Drill Bit T40 Bit for Torx Head Spit W Tech 8 x 40mm Spit 245 IDI 8mm Ø Masonry Drill Bit (40mm embed) - Spit IDI 245 14.4V Li-ion Cordless Combi Drill The Spit IDI 245 is tough and robust, and can easily survive a 2 metre drop test, making it almost impossible to destroy. It has electronic motor protection and the highest torque and RPM in its class, as well as a unique battery runtime and lifetime. Technical Specification Product Code 054273 Weight with Battery 2.4 kg Voltage 14.4 V Battery Capacity 2.6 Ah Li-ion Chuck Size 13 mm Impact Energy 2 Joules No Load Speed 0-380 / 1700 r.p.m Impact Rate 0-25000 b.p.m Torque 75 / 30 Nm (Max) 30 Nm (Sustained) Battery Charge Time 30 mins Drilling Performance - Recommended Maximum Max Drill Diameter - CONCRETE Max Drill Diameter - STEEL Max Drill Diameter - WOOD Max Screwing Diameter LITHIUM-ION 14 mm 13 mm 40 mm 10 mm To minimise substrate damage, hammer mode MUST NOT be selected during drilling operation BLOW-OUT PUMP NOZZLE WIRE BRUSH INJECTION TOOL T30 / T40 BITS

ROI: 1 800 882 388 TECHNICAL SERVICES Onsite: Field Engineers The Technical Team offer comprehensive on-site support for all of our customers. This support can range from product demonstration, application testing and tool box talks, through to proof and failure load testing for safety critical applications. All of our testing is completed in accordance with the Construction Fixing Association guidelines. All test results are then provided in the form of a written test report. To arrange a visit from one of our technical field engineers simply contact the Technical Helpdesk. Product and Operator Training When it comes to safety, we know that training is critical, which is why we pride ourselves on our extensive range of product training offered to our customers. We currently train over 12,000 end users per annum. End users and contractors can benefit from our on-site product training, which is offered free of charge to anyone using a Paslode or Spit product. To find out more about our training including course dates please contact the Freephone Technical Helpdesk. Spit can provide RIBA approved CPD seminars i-expert Anchor Calculation Software The ITW Construction Products Technical Team have recently launched their new improved Spit i-expert calculation software. i-expert is the quickest and easiest way to get a completely accurate specification for any Spit anchor. The new i-expert software boasts improved functionality, allowing for even more accurate anchor selections and specifications. The new software performs calculations according to CC Methodology and is also supplied with the SPITCAD library, which allows Spit anchors to be inserted into designs using AutoCAD programs. It is also now online, which means it is much easier to gain access to, simply by using the following web link - http://i-expert.spit.com

ITW CONSTRUCTION PRODUCTS HEAD OFFICE Fleming Way Crawley West Sussex RH10 9DP CUSTOMER SERVICES Unit R8 Blair Court 100 Borron Street Port Dundas Business Park Glasgow G4 9XG Main Telephone: +44 (0)141 342 1660 Main Facsimile: +44 (0)141 332 7489 Free Phone Enquiries: 0800 652 9260 Free Phone Orderline: 0800 833 381 Free Fax Orderline: 0800 521 077 Ireland Free Phone Orderline: 1 800 946 791 Ireland Free Fax Orderline: 1 800 946 792 TECHNICAL HELPLINE UK Free Phone: 0800 731 4924 Ireland Free Phone: 1 800 882 388 www.itwcp.co.uk www.itwcp.ie Find us on Facebook Search for Paslode Spit UK Follow us on twitter.com/paslodespituk 2405 / 03.12 Porotherm is a Registered Trademark of Wienerberger AG and is used with their consent