CIE S 025: Test Method for LED Lamps, LED Luminaires and LED Modules. Tony Bergen

Similar documents
Assessments of LEDs IESNA LM-79, LM-80 & LM-82

Application/ Requirements for LED Lighting Products Certification Scheme

International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in Office Applications Light Measurement & Quality Parameters

The Latest in LED Lighting Test Methods and Standards. Jianzhong Jiao, Ph.D. OSRAM Opto Semiconductors Inc.

Luminaires V1.2-SSL Directional Luminaire

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

The most sustainable lighting solution. QL 85W Induction Lighting System

Exploratory Study. Accounting for Uncertainty in Lumen Measurements

A Review of Commercial Light Meter Calibration

Apples & Pears, a CELMA guiding paper: Why standardisation of performance criteria for LED luminaires is important

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

ENERGY EFFICIENT LIGHTING PRODUCTS

IEC Self-ballasted compact fluorescent lamps for general lighting services - performance requirements Contents

ICC Recommendations for Color Measurement

LINEAR SYSTEM 3000K 4000K 5000K 6000K 7000K

We bring quality to light. ISP Series Integrating Spheres

T5 Watt-Miser Linear Fluorescent lamps

W E B R I N G Q U A L I T Y T O L I G H T. Handbook of LED Metrology

T5 LongLast. GE Lighting DATA SHEET

LED Module SPECIFICATION. LED Module for Modular Platform Series. LED Platform Module with Fin

USE OF FIBRE OPTICS INTERNATIONAL STANDARDS FOR CALIBRATION LABORATORY ACCREDITATION INTERNATIONAL ELECTROTECHNICAL COMMISSION

Solid State Lighting Annex: 2013 Interlaboratory Comparison

LED light engine / OLED LED linear / area. Umodule STARK QLE G3 lens CLASSIC umodule QLE

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

High flux for outdoor applications

CHM-27 COB Arrays White LED

Reprint (R22) Avoiding Errors in UV Radiation Measurements. By Thomas C. Larason July Reprinted from Photonics Spectra, Laurin Publishing

Welcome to this presentation on LED System Design, part of OSRAM Opto Semiconductors LED 101 series.

Solid State Lighting Definitions for Functional and Decorative Applications

IAS CALIBRATION and TESTING LABORATORY ACCREDITATION PROGRAMS DEFINITIONS

Sound Power Measurement

9W T8 LED TUBE 2FT GENERAL INFORMATION

Discontinued. LUXEON V Portable. power light source. Introduction

Experiences of LED Lighting Products

Bridgelux ES Array Series

Biax S and S/E. Compact Fluorescent Lamps Non-Integrated 5W, 7W, 9W and 11W. GE Lighting DATA SHEET. Product information. Features.

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

OSRAM DULUX SUPERSTAR MICRO TWIST

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 6mm R SNC, SLE G4 10mm R SNC umodule SLE ESSENCE

IKEA Light Sources Technical Information Update

THE MAINTENANCE FACTOR FOR LED LIGHTING

Fortimo LED Line Gen3

LUXEON S. High Flux Density

NI USB-5681 RF Power Meter Specifications

Addendum A for TM-21-11: Projecting Long Term Lumen Maintenance of LED Packages

LINEA 120 FIXED Colour White = MW Matte White RAL 9016 Colour Black = BL Matte Black RAL 9005 Beam Angle 60 EN60598 / EN62031 / EN62471.

New JEDEC thermal testing standards for high power LEDs

AOK i Series LED High Bay / Flood / Tunnel Light

International Commission on Illumination

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

Outdoor Workplace Lighting according to CIE S 015:2005 / pren

Laboratory Capacity and Product Testing: State of Play in India Puneet Randeo Business Developmental Head Verification Services UL India Pvt Ltd

Nederland België / Belgique

Fortimo LED SLM Gen4

E/ECE/324/Rev.2/Add.127 E/ECE/TRANS/505/Rev.2/Add.127

LED light engine / OLED LED linear /area. Umodule STARK LLE CLASSIC STARK LLE. Ordering data

Cross-beam scanning system to detect slim objects. 100 mm in

Nominal Power [W] Radiance Angle [ ] Color Temp. [K]

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

A Guide to the Specification of LED Lighting Products 2012

ANSI/NEMA-FL1 Standard. Heroes Trust Streamlight

Ultrabright White LED, Ø 3 mm

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Video Conference Indirect Wash LED Fixture

Innovative. Lum. Flux** [lm]

Product Information LED PARATHOM PAR Product Overview. Benefits. Key Features

InGaN / Sapphire White Water clear. Parameter Rating Unit

LED SUPERSTAR MR Product description

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Recessed. EvoKit LED Retrofit Kits Gen 3

LED Driver Compact dimming. Udriver LCAI 100W 900mA 1750mA ECO SR ECO series

SuperFlux LEDs. Leaded. Introduction. Features. Key Applications

Precision Lightmeters Made in Germany

Multiple colors, a single focal length

Product Information. LED SUPERSTAR MR Adv. Product Overview. Benefits. Key Features

Biax T/E. Triple Biax Compact Fluorescent Lamps Non-Integrated 13W, 18W, 26W, 32W and 42W. GE Lighting. Product description.

Robot Perception Continued

Cree XLamp XR-E LED. Table of Contents. CLD-DS05 Rev 16B. Product family data sheet

Luminaire efficiency factor system for general lighting

GE Lighting. Albeo LED Luminaire. Linear Industrial Low Bay Lighting. (ALV1 - Series) imagination at work

Welcome to this presentation on Driving LEDs AC-DC Power Supplies, part of OSRAM Opto Semiconductors LED Fundamentals series. In this presentation we

Product Overview. & clear sparkling. Key Features. mm 150 g mm 150 g

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC / CLE CLASSIC umodule CLE

Agilent Cary 60 UV-Vis

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

Radiance Angle [ ] Nominal Power [W] Color Temp. [K]

Datasheet - DS0002 Indice Semiconductor Pty Ltd

FREEZE Canopy. Canopy lighting. QCS Quick-Connection-System. Daylight. Neutral White. Fresh Meat. Packed Meat

IVIOS LED III. LUM Technical Information

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

Cree XLamp MX-6 LEDs Data Sheet

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, W ECO T5

LUXEON 5630 Mid-Power LEDs Illumination Portfolio

Monitoring System Performance

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, W EXCEL T5

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

Cree XLamp XM-L LED 10,000-Lumen High-Bay Reference Design

Transcription:

CIE S 025: Test Method for LED Lamps, LED Luminaires and LED Modules Tony Bergen Secretary, Division 2, International Commission on Illumination (CIE) Technical Director, Photometric Solutions International Pty Ltd

Acknowledgement 2 The contents of many of the slides in this presentation were provided by Dr Yoshi Ohno, National Institute of Standards and Technology (NIST), the US Department of Commerce

Outline 3 Background and purpose of CIE S 025 What measurements it covers Standard test conditions and tolerance interval Operating conditions for device under test Requirements for test equipment Reporting uncertainties of measurement

Outline 4 Background and purpose of CIE S 025 What measurements it covers Standard test conditions and tolerance interval Operating conditions for device under test Requirements for test equipment Reporting uncertainties of measurement

Importance of Quality Assurance of SSL Products 5 Various Solid State Lighting (SSL) products are introduced in many countries Problems Some very low quality products in the market (dim, short life, bad colour) Inaccurate performance claims Insufficient product information (label) Consumers disappointment Delay of adoption of SSL Needs for good standards and regulations

6 Need for International Harmonisation in SSL Testing and Accreditation: Historical DOE new lighting products regulations LM-79 Energy Label EN Test Method Ecodesign Chinese regulations Chinese CQC and GB stds JIS Test Methods JAPAN Eco mark Top Runner Manufacturers & Testing labs NVLAP and other SSL testing acc. PT by NIST for LM-79 Test reports Manufacturers & Testing labs Acc. Prog. for SSL testing PT for EN T.M. Manufacturers & Testing labs CNAS SSL testing acc. PT for Chinese T.M. Manufacturers & Testing labs IA-JAPAN SSL testing acc. PT for JIS T.M.

7 Needs for International Harmonisation in SSL Testing and Accreditation: Now DOE new lighting products regulations Energy Label CIE S 025 Ecodesign Chinese regulations Eco mark International Test Method Manufacturers & Testing labs NVLAP and other SSL testing acc. PT for CIE S 025 Mutual recognition Shared International Test Method Manufacturers & Testing labs Accreditation for SSL testing PT for CIE S 025 International Test Method Manufacturers & Testing labs CNAS SSL testing acc. PT for CIE S 025 International Test Method Manufacturers & Testing labs IA-JAPAN SSL testing acc. PT for CIE S 025

8 CIE standard S 025 provides a unified global test method for harmonisation of testing of LEDs and SSL products

Who is the CIE?? 9 CIE is the International Commission on Illumination (Commission Internationale de l'eclairage) An independent, non-profit organisation recognised by the ISO as an international standardisation body in the field of light and lighting The CIE is about... LIGHT & VISION & COLOUR SCIENCE & STANDARDS KNOWLEDGE TRANSFER & QUALITY ASSURANCE The CIE has been working for over 100 years

CIE Technical Committee TC2-71 10 CIE Division 2 deals with physical measurement of light and radiation CIE TC2-71 CIE Standard on Test Methods for LED Lamps, Luminaires and Modules Established in 2011 Chair: Dr. Yoshi Ohno (NIST, USA) The TC has 37 members from 16 countries in 5 continents: globally representative Standard was published in March 2015: CIE S 025/E:2015 Test Method for LED Lamps, LED Luminaires and LED Modules

CIE TC2-71 and CEN TC169 WG7 11 CIE TC2-71 CIE Standard on test methods for LED Lamps, luminaires and modules Chair, Yoshi Ohno (US) Joint work with CEN TC169 WG7 Photometry, Chair, Guy Vandermeersch (BE) CIE S 025/E:2015 Test Method for LED Lamps, LED Luminaires and LED Modules Published 2015.3.20 EN 13032 Lighting Applications Measurement and Presentation of Photometric Data of Lamps and Luminaires Part 4: LED Lamps, Modules and Luminaires In final approval process

CIE S 025 and LM-79 12 IESNA LM-79-08 was one of the first test methods for SSL devices It became a default global test standard for SSL measurement However, LM-79 was developed by a regional organisation: many national standards could not adopt this CIE S 025 draws on the experience of LM-79: it is more comprehensive; covers more measurement instruments; and has greater depth S 025 development was globally representative S 025 was developed by CIE, a recognised international standards organisation National and regional standardising bodies and regulators should now move to adopting S 025 for LED measurement

Outline 13 Background and purpose of CIE S 025 What measurements it covers Standard test conditions and tolerance interval Operating conditions for device under test Requirements for test equipment Reporting uncertainties of measurement

What it Covers 14 Products covered: LED lamps LED luminaires LED modules Products not covered: LED packages OLED products

Measurements it Covers 15 Total luminous flux Partial luminous flux (useful lumens) Centre beam and beam angles Electrical measurements Luminous efficacy (efficiency) Luminous intensity distribution Chromaticity coordinates Correlated colour temperature Distance from Planckian locus Colour rendering indices Angular colour uniformity

What it Doesn t Cover 16 The Standard does not cover or only partially covers: Dimmable, internal feedback, adjustable colour, adjustable white, multicolour Maintained luminous flux Omni-directional assessment Maintained colour measurements Harmonics & EMC Start time / activation time Switch withstand Lamp Life Temperature cycling shock Endurance Photobiological hazards Flicker Dimmer compatibility Note: Many of these are already covered satisfactorily in other Standards

Outline 17 Background and purpose of CIE S 025 What measurements it covers Standard test conditions and tolerance interval Operating conditions for device under test Requirements for test equipment Reporting uncertainties of measurement

Standard test conditions and tolerance interval 18 4.1 General 4.1.1 Standard Test Conditions Measurements of the photometric, colorimetric and electrical characteristics of a LED device shall be performed by means of appropriate equipment and procedures under defined standard test conditions for operation of the DUT (Device Under Test). A standard test condition includes a set value and a tolerance interval. Measurement results are expressed for the set value of the standard test conditions. Tolerance interval Set value

Standard Test Conditions 19 (For operation of DUT) Ambient temperature (LED lamps, luminaires) 25 C ±1.2 C Surface temperature (LED module) ±2.5 C from specified t p Air movement 0 to 0.25 m/s Test voltage ± 0.4 % from rated supply voltage Set value ± tolerance interval

Need to Consider 20 What is the uncertainty of your instrument (eg: thermometer, anemometer)? How does the uncertainty affect the tolerance interval? 4.1.2 Tolerance Interval The measurement uncertainty of the related parameter shall be taken into account to ensure that the parameter is within the tolerance interval. For this purpose, an acceptance interval is defined as the tolerance interval reduced by the expanded uncertainty (95% confidence) of the measurement of the parameter on both limits of the tolerance.

Tolerance Interval and Acceptance Interval 21 Annex A Tolerance Interval tolerance interval defined in ISO/IEC Guide 98-4 Role of measurement uncertainty in conformity assessment. Tolerance interval is an acceptable range of the true value of the parameter (not the range of readings of instrument). Therefore, to ensure this requirement is fulfilled, measurement uncertainty of the parameter needs to be taken into account.

Tolerance Interval and Acceptance Interval 22

Examples of Acceptance Intervals 23 Tolerance Interval Instrument uncertainty (k=2) Ambient temperature ± 1.2 o C 0.2 o C 0.5 o C Surface temperature (LED module) (example values only) Acceptance interval ± 1.0 o C ± 0.7 o C ± 2.5 o C 0.5 o C ± 2.0 o C Air movement speed ± 0.25 m/s 0.05 m/s ± 0.20 m/s Supply voltage (AC) ± 0.4 % 0.2 % ± 0.2 % (DC) ± 0.2 % 0.1 % ± 0.1 % There are no requirements for the instrument uncertainties The larger the uncertainty, the smaller the acceptance interval

Tolerance Interval and Acceptance Interval 24 3.38 tolerance interval interval of permissible values of a property Note 1 to entry: Unless otherwise stated in a specification, the tolerance limits belong to the tolerance interval. Note 2 to entry: The term tolerance interval as used in conformity assessment has a different meaning from the same term as it is used in statistics. [SOURCE: ISO/IEC Guide 98-4, 3.3.5] 3.39 acceptance interval interval of permissible measured quantity values Note 1 to entry: Unless otherwise stated in the specification, the acceptance limits belong to the acceptance interval. [SOURCE: ISO/IEC Guide 98-4, 3.3.9]

Outside the Tolerance Interval 25 4.1 General 4.1.1 Standard Test Conditions Measured parameter value In case where some of the standard test conditions or requirements cannot be fulfilled, deviations outside the tolerance intervals or requirements are permitted if the related measurements are corrected to the standard test conditions. In such cases, the specific uncertainty component for the corrected parameter shall be evaluated and incorporated into the final uncertainty budget. The actual measurement condition and the fact that correction is made to the standard test condition for the parameter shall be reported in the test report. Tolerance interval Set value

Correction to the Standard Condition 26 4.1 General 4.1.1 Standard Test Conditions Measured parameter value (Even if the tolerance is met) To further reduce the uncertainty of measurements, the results may be corrected for the deviation within the tolerance interval, to conditions at the set value of the standard test condition. The set value is normally the centre value of the tolerance interval, though not always so. Tolerance interval Set value

Direct Correction of the Measurement Result 27 Example: In a goniophotometric measurement, room temperature = 27.3 o C Use a temperature controlled chamber and a luminance meter to make a correction factor to correct the measured result to what it would be at 25.0 o C

Relative luminous flux Correction Using Sensitivity Coefficient 28 1.05 1.04 1.03 1.02 1.01 1.00 0.99 0.98 0.97 0.96 15 20 25 30 35 Ambient temperature ( o C) Sensitivity coefficient = -0.5% / o C Set value = 25 o C Measured value = 27.3 o C Measured luminous flux: F = 1243 lm Corrected luminous flux: F (25 o C) = 1257 lm

Outline 29 Background and purpose of CIE S 025 What measurements it covers Standard test conditions and tolerance interval Operating conditions for device under test Requirements for test equipment Reporting uncertainties of measurement

Temperature Conditions for Operation of DUT 30 LED Lamps LED lamps are measured in standard test conditions and data shall be reported for t amb = 25 o C. If other operating temperatures are declared by the manufacturer, the measured results at the given temperature shall be reported or a service conversion factor shall be provided. LED Modules LED modules are measured in standard test conditions at the rated performance temperature t p. The temperature at the t p -point shall be set at this value for the measurements. a suitable temperature controlled heat sink may be used. Interpolation techniques may also be applied (see Annex C). LED Luminaires LED luminaires are measured in standard test conditions at t amb = 25 o C.

Air Movement 31 Air Movement Measurements shall be made in still air. (Set value: air velocity is zero). Tolerance interval: 0 m/s to 0.25 m/s Tolerance interval This is an example of a tolerance interval where the set point is not in the centre! Set value

Operating Position of Device Under Test (DUT) 32 Operating Position Specific requirement: The DUT shall remain in its designed operating condition (with respect to gravity direction) throughout the stabilization and testing period. If this requirement is not met, the measurements shall be corrected to the performance in the designed operating position.

Stabilization of Device Under Test (DUT) 33 LED Lamps and LED Luminaires The DUT shall be operated (at ambient temperature 25 C) for at least 30 min and it is considered as stable if the relative difference of maximum and minimum readings of light output and electrical power observed over the last 15 minutes is less than 0,5 % of the minimum reading. F P 0 15 min < 0.5 % 30 min

Stabilization of Device Under Test (DUT) 34 LED Modules When the temperature reaches and maintains the specified performance temperature t p within ±1 o C for 15 min, the LED module is considered to be stabilized in temperature. t p ±1 o C 0 15 min The temperature of LED modules is commonly adjusted using a temperaturecontrolled heat sink. tp

Outline 35 Background and purpose of CIE S 025 What measurements it covers Standard test conditions and tolerance interval Operating conditions for device under test Requirements for test equipment Reporting uncertainties of measurement

Laboratory Requirements for Tests 36 All measurements shall be traceable to the SI* when instruments are used to measure absolute values of a quantity relevant to the measurement. 3.37 traceability property of a measurement result whereby the result can be related to a reference (usually NMI s calibration) through a documented unbroken chain of calibrations, each contributing to the measurement uncertainty. * Note: SI is an abbreviation for Système International d Unités (International System of Units) is defined by the CGPM (General Conference of Weights and Measure) and includes the units used internationally today.

Electrical Test Conditions and Electrical Equipment 37 Specific requirements (summary) Calibration uncertainty of AC Voltmeters and ammeters 0.2 % for AC, 0.1 % for DC Calibration uncertainty of AC power meter 0.5 % Bandwidth of AC power meter 100 khz. Internal impedance of the voltage measurement: 1 MW AC power supply THD 1.5% ( 3 % for PF > 0.9) at DUT terminal AC power supply frequency uncertainty 0.2 % DC power supply voltage AC ripple 0.5 %

38 Electrical Test Conditions and Electrical Equipment The voltage of the AC power supply shall be regulated (tested) at the supply terminals of the DUT. (not at the output terminal of power supply. Cables included). Specific requirement: Any drift or fluctuation of the supply voltage during measurement of a DUT shall be within the acceptance interval of the test voltage (4.3.1).

39 Photometric and Colorimetric Measurement Instruments Integrating sphere systems: Sphere-photometer (photometer head as detector) Sphere-spectroradiometer (spectroradiometer as detector) Goniophotometer systems: Goniophotometer (photometer head as detector) Gonio-spectroradiometer (spectroradiometer as detector) Gonio-colorimeter (tristimulus colorimeter as detector) Other types of measurement instruments including integrating hemisphere, near-field goniophotometer and ILMD, are acceptable if they are demonstrated to produce equivalent results as a conventional integrating sphere system or conventional goniophotometer system.

40 Photometric and Colorimetric Measurement Instruments Specific requirements (summary) f 1 of the photometer system (gonio, sphere) 3 % f 2 of the detector head of sphere system 15% Repeatability of sphere (open/close) 0.5 % Stability of the sphere between recalibrations 0.5 % Spectroradiometer bandwidth and interval 5 nm Spectroradiometer wavelength uncertainty 0.5 nm Angle uncertainty of goniophotometers 0.5

Integrating Sphere Measurements 41 Covers both 4 and 2 integrating sphere systems <4 geometry> <2 geometry> From IES LM-79

Integrating Sphere Measurements 42 Gives guidance for: Self-absorption measurements Size of DUT with respect to size of sphere Orientation of DUT in sphere Sphere reflectance uniformity Cosine response Repeatability of closure Calibration interval Spectral responsivity (including coating reflectance)

Goniophotometer Measurements 43 Gives guidance for: Angular scan range and dead angle Angular aiming and accuracy Stray light Spectral responsivity (including mirror reflectance) Test distance for far-field measurements (see next slide)

Distance requirements for goniophotometers 44 Luminous intensity measurements according to the inverse square law require a sufficient photometric distance. Specific requirements for test distance in far-field photometry: For DUT having near cosine (Lambertian) distribution (beam angle 90 ) in all C-planes: 5 D For DUT having a broad angular distribution different from a cosine distribution (beam angle 60 ) in some of the C-planes: 10 D For DUT with narrower angular distributions, steep gradients in the luminous intensity distribution or critical glare control: 15 D For DUT where there are large non-luminous spaces between the luminous areas: 15 (D+S) where D is the maximal luminous dimension of the DUT and S is the largest distance between two adjacent luminous areas.

Outline 45 Background and purpose of CIE S 025 What measurements it covers Standard test conditions and tolerance interval Operating conditions for device under test Requirements for test equipment Reporting uncertainties of measurement

Reporting of Measurement Uncertainties 46 It is a simple fact of life that no measurement is ever perfect For each measurement there is an uncertainty of measurement, which is like an estimate of the possible error that could be associated with the measurement result CIE S 025 requires that all measurement reports shall include a statement of uncertainties of measurement

Reporting of Measurement Uncertainties 47 A statement of uncertainties consists of a magnitude and an associated probability Magnitude May be relative (eg: 5%) May be absolute (eg: 14 lm) Probability May be a coverage probability, eg: 95% May be a coverage factor, eg: k = 2 The measured luminous flux is 783 lm ± 4.2% with a coverage factor k = 2 The correlated colour temperature is 3012 K ± 55 K with a confidence interval of 95%

Reporting of Measurement Uncertainties 48 Ideally, for best practice, measurement uncertainties would be evaluated for each test However for practical purposes, it is permitted to use uncertainty values for a typical product of the similar type, with a statement that indicates so in the test report If a lab does this, they must keep a detailed uncertainty budget and evidence of how they evaluated this typical product

Reporting of Measurement Uncertainties 49 The measurement uncertainties shall be evaluated according to ISO/IEC Guide 98-3 and its supplements Guidance for evaluating measurement uncertainties for LED lighting devices is given in Chapter 8 and Annex D of CIE S 025 Guidance is also available in CIE 198:2011 Determination of Measurement Uncertainties in Photometry and its supplements

Summary 50 CIE has recently published the Standard CIE S 025/E:2015, which is a standard test method for photometric testing of LED lamps, luminaires and modules CIE S 025 can be used for worldwide harmonised testing of LED lighting products It contains test conditions and requirements for equipment used to perform the tests It requires mandatory reporting of measurement uncertainties Standardising bodies and regulators are encouraged to move to adopting CIE S 025 for LED measurement http://div2.cie.co.at/?i_ca_id=563&pubid=491

Upcoming CIE Conferences 51 CIE s 28th Quadrennial Session, Manchester/UK, June 28 - July 4, 2015 CIE Lighting Quality and Energy Efficiency Conference, Melbourne/Australia, March 3-5, 2016 More information: http://www.cie.co.at/

52 Thank you for your kind attention. Any questions? Tony Bergen tonyb@photometricsolutions.com