FIBER OPTIC CABLES User Manual ENGLISH

Similar documents
Integra Luxtec OPERATION AND SERVICE MANUAL. UltraLite Pro Headlight

Outlines: Original Artwork: LeMaitre. Light Post Adapter. Light Post Adapter. Fits Olympus, Storz, and Stryker Equipment* English Instructions for Use

3 WATT LED SPOTLIGHT Model No. SLM

CompacVideo Otoscope. Model (NTSC) and 23120P (PAL) Operating Instruction Manual

For safety information, see the ABI PRISM 310 Genetic Analyzer User s Manual (PN or ).

NFC Communication Tray Model: HHX-IT3-Z

User s Guide OSXL-100-PE. Thermal Imaging Camera Enclosure. Shop online at omega.com SM

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada

Mini-led spotlight with magnetic base

Sip/Puff Switch User Guide

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

How To Use The Visifault Visual Fault Locator

POZZI WINDOW COMPANY LIMITED WARRANTY WINDOWS, DOORS AND COMPONENT PARTS

Installation Instructions

Warranty Terms. QLogic-provided cables, optics and other accessories are warranted for ninety (90) days from date of purchase.

User Guide. HDMI Active Cable Extender. DVI-7370c

HDMI Fiber Optic Cable. DVI-D Fiber Optic Cable. User Guide

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H

American DJ. Roto-Balls VS MKII. User Instructions. American DJ

Ceiling Mount Air Handler Manual

Installation Instructions

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

RT-200 HI-TEST ROPE TESTER

Powerware Relay-Serial Card User s Guide

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

Threaded Inline Air Heaters

User Manual (English)

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Dual Cushion User Manual. Specialist Suppliers to the Healthcare Industry

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM

Ultrasonic Jewelry/DVD Cleaner. make jewelry, dvds and more sparkle like new

BroadBand PowerShield. User Manual

User Instructions. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

RomiApex A-15. APEX LOCATOR User Manual

VW TDI (Golf, Jetta, New Beetle) Upgrade Turbocharger

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

inmarsat.com/isatphone

PARTICLE GENERATOR MODEL 8026

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

Scotchgard Multi-Layer Protective Film 1004

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Transcutaneous Electrical Nerve Stimulation Device LUMI-TENS

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

HID H4 BI-XENON FITTING GUIDE. Carefully read the following notes before starting work.

MODEL VG08008 CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING

Ultra-Violet Products Ltd 2066 W 11th Street, Upland, CA Unit 1, Trinity Hall Farm Estate

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Educational Tool for Medical Laser Programs 1. Laser Safety

el-720 Carbon Dioxide Gas Leak Detector User s Guide

Installation Guide Smart-UPS X External Battery Pack SMX120BP

BancTec, Inc. PRINTER SERVICE CONTRACT

2-SLICE COOL TOUCH TOASTER

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

MOTOROLA MOBILITY INC. LIMITED GLOBAL WARRANTY MOTOROLA TABLET COMPUTER

We appreciate your time and patience during the claim process. Please send your completed and signed Warranty Claim Form to:

VPCCCare. Virtual PC Center Service Warranty Program

UV100E Ultraviolet System

Mini Power Bank and Charger

Leak Detection System

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

Model SRMD Setra Remote Monitoring Display

VW TDI (Golf, Jetta, New Beetle) Upgrade Turbocharger

Standard laryngoscope blade assemblies Directions for use

Master Prep Professional

Frequently Asked Questions About OHP Lamps

Installation Instructions

USB Port Hub with USB Power Cable. User s Manual

Please read and keep these instructions. Run water through your machine before first use

staple gun with 5/16 Long staples

CUNO TM Series NB Bags for Liquid Filtration

About this Manual. Support for Your Product

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Bottom Loading Water Dispenser

Instructions for Use. A-dec 500 Assistant s Instrumentation. Model 551

SC, FC and ST * Hot Melt Fiber Optic Connectors

Integra. Surgical Illumination and Visualization Systems. Limit uncertainty with maximum light to visualize critical anatomy

Quick Installation Guide TK-209K TK-409K

Nokia Bluetooth Headset BH-104

TTL to RS232 Adapter User Guide

OAK WORKBENCH WITH 2 DRAWERS


Ultrasonic Distance Meter. Operation Manual

1 For All Non-Programmable Digital Thermostat

WHYNTER 21 Bottle Dual Temperature Zone Freestanding Wine Cooler

Super Slider ADJUSTABLE FROM Model #HD26229

Wireless Indoor/ Outdoor Thermometer

IR Repeater. Operation Manual P8620

User and Installation Guide

Owner s Manual. Pelican Custom Premium WHWF 1865/2162

Transcription:

FIBER OPTIC CABLES User Manual ENGLISH 99 Hartwell Street West Boylston, MA 01583 USA Tel: +1-508-835-9700 US Toll Free: 1-800-325-8966 Fax: +1-508-835-9976 Website: http://www.integra-surgical.com E-mail: custsvcluxtec@integra-surgical.com

Table of Contents Page Description 2 indication for Use 3 Symbols 4 General Warnings 4 precautions 5 cable Care 6-7 Maintenance 7 repair and Return Information 7 limited Express Warranty 1

INDICATION FOR USE This fiber optic cable is designed to deliver illumination from a high intensity light source to a surgical headlight or surgical instrument for surgical site illumination, either standard or minimally invasive. It is compatible for use with light sources made with the following: Xenon with lamp power rating of up to 300 Watts, Halogen with lamp power rating of up to 250 Watts, or Metal Halide with lamp power rating of up to 100 Watts. Any light source used with this cable should have a minimum of 90% IR filtering to prevent cable damage during use. 2

TABLE OF SYMBOLS Found on a medical grade light source, other illumination related equipment, fiber optic cables and corresponding packaging. Attention; Consult Accompanying Documents Fuse Caution: High Voltage Type CF Equipment Equipotentiality Type BF Equipment Protective Earth High Temperature On / Off Brightness Stand-by Motor System Status Display Fan System CE Do Not Dispose Listed by ETl Push Listed by CSA Hours Part Number Over Temperature Batch Code or Intensity Lamp Keep dry Serial Number Authorized Representative in the European Community Manufacturer 3

GENERAL WARNINGS The user should carefully study this manual before making any attempt to use the product clinically. Instructions should be followed specifically, with special attention given to warnings and cleaning instructions. This manual should also be available to the surgical team during a procedure. Follow the instructions in the operating manuals of other manufacturers equipment when they are used in conjunction with this product. Before every procedure, carefully inspect the fiber optic cable to ensure it has been properly maintained, cleaned and sterilized (if compatible) and that it is fully functional. Care should be taken to follow the maintenance and cleaning instructions. Excessive bending of the cable should be avoided. Use care not to point the cable directly at the eye while in operation. The brilliant light output can cause severe eye discomfort. Light sources use high intensity lamps, which produce heat as well as brilliant light. The high brightness and the light output of the fiber optic cable can cause burns. FIRE HAZARD: DO NOT DRAPE OR COVER THE LIGHT SOURCE OR THE FIBER OPTIC CABLE WHILE IT IS OPERATING. DO NOT PLACE THE CABLE END FITTING ON A DRAPE WHILE IT IS OPERATING. PRECAUTIONS Take precautions to verify that the fiber optic cable is appropriately suited for the light source. Xenon and other high illumination light sources require premium fiber optic cables in order to achieve optimal performance and prevent damage to the fibers, thereby diminishing the quality of the light output or the useful life of fiber optic cable. Take precautions not to touch or disconnect the cable end fitting from the turret until the light source has been shut down for a period of time and allowed to cool. The cable end fitting will remain hot immediately following shut down, which can cause burns. Take precautions to not place and rest a hot cable end fitting and/or head light on a patient or allow the system to come in contact with un-protected hands or tissue. The entire system should be allowed to cool following use. Failure to do so can cause burns and/or tissue damage. 4

CABLE CARE Fiber optic cables are fine, high quality optical instruments. You can prolong the useful life by following a few guidelines: Avoid stretching your cable, forming configurations involving sharp angles or kinks, or contact with sharp or pointed objects. The internal light fibers are made of glass, a material that breaks under stress. Fiber breakage will result in diminished light output. Utilize the gown clips (if provided) to keep the headlight cable secured to the surgeon's gown for greater comfort and maneuverability. (This does not apply to instrument cables.) Do not use your fiber optic cable with any alterations to its original design or fabrication. Bundle size (aperture) of the fiber optic cable should be matched to the aperture of the instrument to obtain maximum light output. NOTE: A larger aperture fiber optic cable will not increase light output of a smaller aperture instrument. Keep the optical faces from contacting the floor or other hard surfaces. The resulting scratches will diminish light output. Store the cables in sterilization trays for additional protection. Any inadvertent cut or puncture to the outer sheath will render the cable unsafe. It should be taken out of service immediately. 5

MAINTENANCE Follow all applicable bloodborne pathogen procedures as indicated by OSHA and /or your hospital requirements when cleaning, disinfecting, and sterilizing instruments and accessories. Cleaning (other than UltraLite headlight cables*): Lukewarm water with mild detergent is recommended to remove all blood and debris. (Do not use synthetic detergents or oil-based soap, as these chemicals may be absorbed into the cable and could subsequently leak out and cause tissue reactions.) Rinse thoroughly with distilled water, taking care to rinse the face of glass fiber at both ends of the cable. Cleaning (UltraLite headlight cables*): Luxtec suggests the use of alcohol wipes to clean the UltraLite and Sweatband headlight cables. Disinfecting (other than UltraLite headlight cables*): Cables may be soaked briefly in disinfecting solutions without damage. Refer to the manufacturer's time specifications; however, avoid soaking cables for more than 10 minutes. Disinfecting (UltraLite headlight cables*): Soaking the UltraLite and Sweatband headlight cables in any sterilizing disinfectant should be avoided. There is a lens assembly at the light source end, which is not sealed and could allow moisture to penetrate behind the lens. Sterilization (other than UltraLite headlight cables*): RECOMMENDED STERILIZATION METHODS STEAM Hospital Steam Sterilizer compliant to AAMI ST8 Place clean and dry cables in a steam sterilization self seal pouch or compatible container. Temperature: 270ºF (132 ºC) Exposure Time: 4.0 Minutes Drying Time: 20.0 Minutes ETO (ethylene oxide) Place clean and dry cables in a ETO self seal pouch or compatible container. ETO concentration- 100% Exposure time 60 minutes Temperature- 131 ºF (55 ºC) Aeration- 8 hours minimum STERIS SYSTEM Place clean and dry cables in a self seal pouch or compatible container. Steris 20 Sterilant Concentration Place a Peracetic acid Chemical Indicator and cable in tray and secure lid. Place tray into the STERIS SYSTEM 1 Exposure Time: 12.0 Minutes CIDEX PLUS 28 day Solution Clean and dry the cable taking care not to scratch any of the optical surfaces. Follow the manufacturer s instructions to prepare the CIDEX PLUS Sterilant to the manufacturer s recommended effective concentration. Use the CIDEX PLUS solution test strip to verify effectiveness of the sterilant. Submerge Cable in CIDEX PLUS Allow thorough soak for 10 hours at 68-77 ºF (20-25 ºC) Dry per manufacturer s recommendations. 6 * UltraLite and Sweatband headlight cables can be identified by the curved lens at the light source end.

Sterilization (UltraLite headlight cables*): The UltraLite fiber optic cable has not been specifically designed to withstand sterilization. There is a lens assembly at the light source end, which is not sealed, and could allow moisture to penetrate behind the lensing. Meticulous care should be taken to avoid cable contact with sharp or pointed objects. Ensure your autoclave is operating correctly for effective sterilization. Consult your autoclave manual for specific instructions, conditions and exposure periods. The pressure differential, which occurs during steam autoclaving, may cause small bubbles in the tubing. These bubbles will not affect the fiber optic cable and will dissipate in time. Following sterilization of your fiber optic cable, allow it to cool very slowly to room temperature. DO NOT immerse or rinse in a cold liquid, as this will cause fiber breakage and extensive light transmitting losses. REPAIR AND RETURN INFORMATION Indications for replacement: 1. When a fiber optic cable shows 30% loss of light transmission of its fibers, the cable needs to be replaced. This can be determined while holding both ends of the cable:point one cable end toward a light while looking at the other end. DO NOT PERFORM THIS CHECK WHILE THE FIBER OPTIC CABLE IS ATTACHED TO AN OPERATING LIGHT SOURCE. The brilliant light output can cause severe eye discomfort. 2. When there is separation of the cable components that can be seen with a visual inspection, such as strain relief and sheath or endfittings. 3. When a cable has been excessively stretched or cut. Contact your local LUXTEC representative to order replacement cables or call Luxtec customer Service Department at 1-800-325-8966 (USA & Canada) or at +1-508-835-9700. ATTENTION: OPERATING ROOM PERSONNEL We require that you clean and sterilize (if compatible) all equipment before returning for repair. If equipment is received in an unsanitary condition, an additional cleaning fee will be charged, including those pieces repaired under our warranty. Please note on shipping packaging if contents have not, or cannot be sterilized. LIMITED EXPRESS WARRANTY LUXTEC warrants that the fiber optic cable furnished hereunder shall be free from defects in material and workmanship under normal use and service for a period of eighteen (18) months from the date of shipment from LUXTEC, excluding fiber breakage. LUXTEC Premium UltraLite headlight cables feature a lifetime warranty against browning. LUXTEC s sole and exclusive liability under this warranty shall be, at LUXTEC s option, either to repair or replace any component of the cable which fails during the warranty period due to any defect in workmanship or material F.O.B. factory if: (1) customer promptly reports such defect to LUXTEC in writing, (2) if requested by LUXTEC, customer returns equipment to LUXTEC with shipping charges pre-paid and (3) upon inspection, LUXTEC finds the cable to be defective. This warranty is contingent upon normal and proper use of the cable and does not cover fiber breakage or a cable which has been modified without written approval of LUXTEC, subjected to unusual physical stress, or damaged during shipment. This warranty is nontransferable unless authorized in writing by LUXTEC. If LUXTEC is unable to remedy any defect in the cable as required by the foregoing warranties, LUXTEC s liability shall not in any event exceed the purchase price received hereunder by LUXTEC for the equipment. THE WARRANTIES SET FORTH HEREIN ARE IN LIEU OF ANY OTHER REPRESENTATIONS OR WARRANTIES. LUXTEC DISCLAIMS AND CUSTOMER WAIVES ALL OTHER EXPRESS OR IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO, ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND LUXTECNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL LUXTEC BE LIABLE TO ANY PARTY FOR INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, WHETHER RELATED TO THIS OR ANY OTHER CLAIM, REGARDLESS OF ANY KNOWLEDGE OF LUXTEC OF SUCH POTENTIAL DAMAGES. * UltraLite and Sweatband headlight cables can be identified by the curved lens at the light source end. 7

Three-point Comfort System www.integra-surgical.com The Integra wave logo, Integra Surgical, UltraLite and Luxtec are trademarks of Integra LifeSciences Corporation. Copyright 2010 Integra LifeSciences Corporation. All rights reserved. Printed in USA Xk P/N 850165 Rev. G 12/09