Notifier by Honeywell: Panel Selection Guide

Similar documents
Notifier by Honeywell: Voice Alarm Solutions

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Notifier by Honeywell: Cost Effective Fire Detection and Alarm

Repeaters and Mimics Data Sheet

Software Release For DF6000/CF3000/FX6000. Site Installer Network Card

FIREDEX Conventional Fire Panels

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

Emergency Voice Communication Systems EVCS Network 8 Data Sheet

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications

25 Years of Manufacturing Excellence INFINITY. The Intelligent 2 Wire Fire Detection System for Professionals

SECTION DETECTION AND ALARM

C E R T I F I C AT I O N LPCB B O A R D P R E V E N T L O S S. Cooper Fire Systems

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

NJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen)

Always on the Lookout Perfect Protection against Burglary

Product Overview Brochure. Flexibility to design a fire system that best suits you

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Product Data Sheet. User Manual. User Manual MX-4100, MX-4200, MX-4400, Mx-4400/LE & Mx-4800 Fire Alarm Control Panels

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Uninterruptible Power Supply

Potter Plus. Fire Alarm Control Panels

SD Rack. DiGiCo SD Rack. User Manual B - August

GST301. (Single Protection Zone) Operation Manual

A-307. Mobile Data Terminal. Android OS Platform Datasheet

VEGA Analogue Addressable Control Panels

MINERVA MX MX Virtual Multi-Sensor Detectors

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Building Solutions. One Honeywell Solution for All of Your Fire Systems Needs

Current Monitoring Kit

PRODUCT LIST Facility DDC Access WebXL DDC

Protec. Protec Algo-Tec TM 6300 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Discovery 1-4 Loop Analogue Addressable Control Panel Application Guide

CB200W Water Leak Detection Panel Application Guide

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

T Zone Weekly Timer

FIRE ALARM PANEL & SYSTEM OPERATION ID50 SYSTEM. The Fire Alarm System can be activated in the following ways :~

CAPTURE H.264 Compression Embedded DVR Introduction

Omni 600 control panel with 8 zone LED keypad

ADEMCO LYNXR-I Security Systems

Current Monitoring Kit QUICK START GUIDE

Fire Control Panels. Remote Annunciator Panels. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features. Introduction

Accenta/Optima. User Guide. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number: Honeywell Security

How To Use A Pkn10 (Powerline) With A Microsd Card (Powerkit) On A Powerline (Powergen) Or Powerline 2 (Powerbee) (Powerbmi) (Pk10) (Operating

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

XFP Programming Software Help Manual. <7/2008> Computionics Ltd. (C-TEC)

Ozbytes Design Biometric Fingerprint Time and Attendance and Access Control Unit Item Code: OZD-ABC-AV100

Expansion Modules & Accessories

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S :111

TS510 & TS500. Installation & User Guide. Compatible Equipment

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

ABUS WIRELESS ALARM SYSTEM

BabyWare Imperial PC Software

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February FA-300 SERIES Fire Alarm Control Panel

APR-PRT3 Printer Module: C-Bus Programming Instructions

Input module, input/output module

SNMP Web Management. User s Manual For SNMP Web Card/Box

Premier M Plus & Infinity 8

nr 28 nr 68 nr 4 nr 1

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Conventional Fire Detection and Extinguishant Control System Specification

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

PROTEC CIRRUS HYBRID ASPIRATING SMOKE DETECTION SYSTEMS

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19

Overview of Fire Alarm Systems and Maintenance

The supplier and installer of the system should be approved by the local civil defence authority.

Specifications Control Features. User Interface. Communicator. Programmable Outputs. Access Control. System Response

4 Loop Analogue Addressable Control Panels

Honeywell Security. Honeywell Hello Series Video Door Phone System Product Catalog. Smile reaches your heart. Smile reaches your heart

JUNIOR V3. Fire Alarm Control Panel INSTALLATION & COMMISSIONING MANUAL GLOBAL REVISION 2.3 FIRE EQUIPMENT QUEUE REVIEW STATUS ZONES

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

DC-8706K Auto Dial Alarm System

Algo 8180 Integration with Zultys

Fire Detection Product Range

Swiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138.

Contents Chapter 1: Introduction... 3 Chapter 2: Ethernet (LAN)... 5 Chapter 3: ZigBee Wireless Connection Options... 7

Biometric Fingerprint Time and Attendance and Access Control Unit OZD-ABC-T60 Technical Specification Data Sheet. Ozbytes Design

Operating the DS9400 Fire Alarm Control/Communicator

Emerson Smart Firewall

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

Syncro. Multi Loop Analogue Addressable Fire Control Panel. Product Manual. Man-1055 Issue 21 September 2010

Engineer Paging. Staff Paging. Deaf Alert.

Global System Technology(UK) PLC The Intelligent Solution

An intercom completes any access control system by providing a means for the user of screening visitors before granting access, thereby significantly

Ademco Vista-20P/First Alert FA-168C Basic Commands

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

FIRE. 4100U Fire Alarm. Operator s Manual. Operator's Manual. Operator s Manual. LT0395 Iss 1.0

NetworX NX-6V2. LED Keypad User Manual

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

Iso-Gard Series 6 Line Isolation Monitors

My2B. MyALARM2 GSM/GPRS Datalogger with Alarm Management

User Manual of Web Client

Syncro AS. Analogue Addressable Fire Control Panel. Product Manual Man-1096 Issue 14 May 2016

HyperAccess Access Control System

Kentec Electronics Ltd. Units Fawkes Avenue Questor Dartford Kent DA1 1JQ England Tel: +44(0) Fax: +44(0)

PRODUCT CATALOGUE.

ACTIVE 5 ENGINEERING MANUAL

Transcription:

Notifier by Honeywell: Panel Selection Guide 1

Introduction This guide has been produced to help guide you through the advanced features of the Notifier range of addressable fire alarm control panels. At Notifier we pride ourselves in our range of capable, robust and flexible fire systems which are designed to maximise the benefits of our comprehensive range of detection technologies, AV devices and modules. System Capacity Loops 1 2, 2-8 1 or 2 2, 2-8 Detection Zones 16 16/80 64/255 255 Zone LEDs 16 16/80 64 Option 64/128/256 LCD Display (lines x characters) 2x40 2x40 15x40 6x30 Devices (Max) 99+99 792+792 318+318 792+792 ELIB allows >512 devices N/A No No Yes Loop Current 500mA 500mA 750mA 500mA Maximum loop length (based on 1.5mm 2, 2 core cable) 2000m 2000m 3500m 2000m Sounders 2 2 2 2 configurable as either Relays 2 Fire + Fault 2 Repeater Connection Option Option Built-in[1] Option RS232 Communication Option 1 2 2 RS232 or RS485 RS485 Communication Option 1 2 2 RS232 or RS485 PSU 1.5A 3A (4.5A, 7A) 3A 3A (4.5A, 7A) Aux DC Out 250mA 2 x 1A 500mA 2 x 1A Maximum Battery 12Ah 17Ah (38Ah, 130 Ah external) 12Ah (38Ah external) 17Ah (38Ah, 130Ah external) Printer Option Option No Option Mechanical Specification First Fix bracket No No Yes No Hinged panel door for easy access No No Yes No Flush mount kit with first fix option No Yes Yes Yes 19 Rack Mounting option No Adaptor First fix bracket Adaptor Configuration Flash firmware upgrade Main f/w EPROM All (main and loop) EPROM Complete automatic backup No No SD Card No Configuration Download RS232 RS232 USB RS232 [1] Cannot be used if network card fitted 2 3

4 Panel Functions Upload logo of choice to LCD screen No No Yes Yes Display Maintenance Contact Details No No Yes No Site configurable buttons (SOFT keys) None None 4 None SOFT key functions N/A N/A C&E N/A Built-in help No No Yes No Separate Silence & Resound No Yes Yes No Disable Sounders Menu Menu Button & Menu Menu Disable individual sounders Configurable Configurable No Configurable Disable Fire Protection (relays) Menu Menu Button & Menu Menu Disable Remote Fire Output Menu Menu Button & Menu Menu Configurable Button Access No No Yes No Disable cause of active condition Menu Shortcut Shortcut Shortcut Engineer Mute No Yes Yes (with auto time-out) Yes (with auto time-out) Integration with Third Party Systems Third party Protocol for Integration Yes Yes Yes Yes Third Party Protocol Virtual Outputs No No Yes Yes Third Party Protocol Virtual Inputs No No Future No Link to D1 Voice Alarm System No No Yes Yes Loop Functionality CLIP Compatibility Yes Yes Yes Yes Opal Compatibility Yes No Yes Yes Opal sounder tone/volume 8 Tones No 8 Tones 8 Tones Sounder synchronisation No Yes (by panel) Yes (across network) Yes (across network) Different tone for class change No No Yes Yes Opal Sub-Addressing No No Yes No Multi-Modules take only 1 address No No Yes No Full Compatibility with loop based FAAST LT No No Yes No VIEW & SMART support Yes Basic Yes Yes Smoke testing of SMART No No Yes CLIP only Individual response to SMART thermal alarm Yes Yes Yes Yes Individual response to SMART criteria No No Yes No 5

Networking Network None RS485 Master-Slave (upto 8 panels) ID²net (upto 16 panels) ID²net (upto 63 panels) or RS485 Master-Slave (upto 8 panels) Fibre Optic Network adapter N/A No External (Future) Yes Zones shared across network panels N/A No Yes No Local Zones on Network N/A Yes Yes (max. 1024 zone LEDs per network) Yes Network Zones N/A No 4080 per-network (64 zone LEDs available) 8192 per-network Network Sectoring N/A Event distribution Display & Control Filtering Yes Cause & Effect Cause and Effect lines 64 512 512 512 Cause & Effect inputs loop device Fire, Pre-Alarm, Fault, Disable, Fire, Pre-Alarm, Fault, Non-fire activation Cause & Effect inputs zone Fire, Pre-Alarm, Fault, Disable, Gas Alarms & Technical Alarm Cause & Effect outputs device Activate Output, Disable Activate Output, Disable Activate Output, Disable Activate Output, Disable Cause and Effect outputs zone Activate Output, Disable Activate Output, Disable Activate Output, Disable Activate Output, Disable Cause and Effect Coincidence Yes Yes Yes Yes Cause and Effect - Transfer flags No 128 128 128 Boolean operations on transfer flags No No AND, AND NOT, OR AND, AND NOT, OR Event Log 512 events 600 events >100,000 events 600 events Device Coincidence Yes No Yes Yes Zone Coincidence Yes No Yes Yes Type B coincidence by device type No No Separate count for SMART thermal alarms Single confirmation count Auto-Reset of Type B First Fire No No Yes No Type B confirmation by same device No No Configurable No Cells Supported No 175 255 255 Auto-Learn modules/sensors separately No Yes Yes Yes Remote LED activated by C&E Opal No Opal Opal System Codes and Security Back Door Passcode Code cracker Code cracker Temporary code Code cracker ESD code secret if overridden No No Yes No 6 7

Notifier by Honeywell: Fire Systems Safety, Integrity and Heritage Notifier by Honeywell is the world s largest manufacturer and supplier of engineered fire alarm systems. With over 400 Engineered Systems Distributors worldwide, and regional support on every continent, we have the flexibility to meet our customers requirements. With over 60 years of experience, we offer unrivalled specialist knowledge and products designed to meet all needs. Notifier offers a comprehensive line of quality fire detection and alarm control solutions. These include everything from smoke detection and notification, non-addressable fire alarm panels, analogue addressable systems, to advanced network and integration packages. As a leader in the fire safety market, Notifier is dedicated to the highest standards of service and product quality. Our operations are accredited to ISO 9001 and our products are designed and manufactured to meet every major international approval, including LPCB, VdS, UL, ULC and BOSEC/ANPI. Notifier is a division of Honeywell International, a diversified technology and manufacturing leader, serving customers worldwide. By partnering with Notifier, you have the reassurance of working with a company of global standing that provides cutting edge fire detection systems. Caburn House T: +44 (0) 1273 897000 Brooks Road F: +44 (0) 1273 376 894 Lewes, E. Sussex E: sales@notifierfiresystems.co.uk BN7 2BY www.notifierfiresystems.co.uk NFR0089_EN_A_0915