Coax Twisted Pair Balun Coax Twisted Pair Balun w/cable Mini Coax Twisted Pair Balun

Similar documents
FIBER OPTIC A/B/C SWITCH (Latching)

SINGLE MODE FIBER OPTIC A/B SWITCH (LATCHING)

Power Over Ethernet Adapters POE101

This paper will explain some of the more important factors on how UTP wires work; specifically it will cover the following:

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Provides one channel for Ethernet over existing

4-Port Switch. 10/100/1000 Mbps Gigabit Ethernet GS104. Installation Guide

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

5-Port Switch 10/100/1000 Mbps Gigabit Ethernet GS105

16-port Gigabit Switch 10/100/1000 Mbps GS116. Installation Guide

WARNING CANADIAN D.O.C. WARNING

FlexPoint T1/E1 Copper to Fiber Line Driver

Installation Guide. Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit. Issue: PN: L Rev. A

Pan Dacom. Nets work together. SPEED-DSL 2.3 Ethernet connection over 2-wires up to 2.3 Mbit/s ( A, A) Manual

Start Here. Features. Model EN104/EN108/EN116 Ethernet Hub Installation Guide

Características. Starligh SA 9 de julio 1595 Córdoba Argentina /

Ethernet Patch Cord Wiring

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

Gigabit Ethernet Switch 10/100/1000 Mbps GS605 / GS608. Installation Guide

SPEED-DSL 2.3 Ethernet connection over 2-wires up to 2.3 Mbit/s. Manual

10BASE-T/100BASE-TX & 100BASE-FX 2-Port Bridging Media Converter

MoCA Adapter MC1001 v2 Installation Guide

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

LMR16TC Mini 10BASE-T Repeater. Installation Guide

KVM - DVI, USB 2.0, Cat 5 Extender

LocoNet, the Digitrax Difference

LOCALMAP 100 Cable Tester Identifier Kit 234 Identifier Kit 5678 LOCALMAP 100 Carry Case

T1/E1 Copper-to-Fiber Slide-In-Module Media Converters USER S GUIDE COMPLIANCE INFORMATION C/T1E1-CF-01

Provides one channel for Ethernet over existing

InnoMedia ESBC B. Quick Install Guide. 1

Technical Support. Support Information

Network Design. Yiannos Mylonas

USB Mini Print Server PS121. Installation Guide

8-Port 10/100M N-Way Mini Switch

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

9,'(2 #6(3$5$725 8VHU V#0DQXDO 96043;

Model 201 Wiegand Touchpad Reader Installation Guide

Cable Specifications. T3 Trunk Cabling APPENDIX

AXIS T81B22 DC 30W Midspan

SMARTen 24 UTP Patch Panels

T-Extender E-Extender

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

CCTV System Troubleshooting Guide

LMR8TT Mini 10BASE-T Hub/Repeater

C24-CAMANL Video Server/Encoder

Copper Gigabit Switch Installation Guide

TCR Token Ring Copper Repeater Module

USB Rover port USB m Cat 5 Extender. User Guide

INSTALLATION GUIDE ConnectLine TV Adapter Getting started

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

USB/VGA Cat 5 UTP Console Extender

Cable Pinouts. SRP I/O Module

ES-3305P V2 / ES-3308P V2. Quick Installation Guide / v1.0

Quick Installation Guide 8-Port 10/100/1000Mbps Green Switch

9,'(2 #6(3$5$725 8VHU V#0DQXDO

SMARTen 24 STP Patch Panels

Speed-DSL 9.2 Ethernet connection over 8-wires up to 9.2 Mbit/s. Manual * * * *

NT1 Type 400. NT1 Type 400 Standalone L1 NT1 Type 400 Circuit Pack USER MANUAL

Comm5 Wiring Installation

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

InnoMedia ESBC B. Quick Install Guide. 1

Model CFA-24 Transparent Cable Farm Automation Switch

Cable Guide. Click on the subject to view the information. Digi Cables Building Cables General Cable Information

MDI/MDIX) FEP-32008T-3

palm Switch Port 10/100 Base-TX Switch with Auto MDI/MDI-X User Guide

Quick Installation Guide. 16-Port 10/100Mbps Fast Ethernet Switch

UIM-2T1 T1 Loop Bonding Uplink Interface Module

Document

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

HP-1000E v2. User s Manual. Powerline Ethernet Adapter. HP1000E v2 User s Manual

TNE1500-P and TNE1500-S Single Line T1 Network Extender Provider and Subscriber

User Guide. MC100CM MC110CS Fast Ethernet Media Converter. MC111CS MC112CS WDM Fast Ethernet Media Converter

EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System

Perle 10/100 Ethernet Media Converters

Implementing Fast Ethernet

Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka

Gigabit eco-friendly Ethernet Switch AT-GS900/8. Installation Guide Rev. A

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

System Wiring Design Guide

Network Cabling Guide

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

Comtrol Cable User Guide

Panduit 28 AWG Patch Cords Installation Guideline

Model 0400 (800) MODEL 0400 ETHERNET POCKET HUB SPECIFICATIONS (E-TBT-HB-0400) Standards. Physical

Physics 3330 Experiment #2 Fall DC techniques, dividers, and bridges R 2 =(1-S)R P R 1 =SR P. R P =10kΩ 10-turn pot.

PS/2 KVM Console Extender User Manual (GCE250)

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

Chapter 4 Connecting to the Internet through an ISP

Wireless Optical Mouse

User Guide. Guide d utilisation Guida dell'utente Benutzerhandbuch Guía del usuario Guia do Usuário WNA-100. Wireless Network Adapter

LFH4-M/LFH8-M Mini Fast Hubs. Installation Guide

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

IEEE 802.3af 4-Port Power over Ethernet Injector Hub POE-400. User s Manual

Cisco - Ethernet 100BaseTX and 10BaseT Cables: Guidelines and Specifications

NOKIA 32 SUPPORT GUIDE FOR INSTALLING NOKIA 32

Cabling Specifications

Installation & Weatherproofing Guide for ENCOM Broadband Radios

Nevco, Inc. Installation Manual

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

Transcription:

AUGUST 1993 IC002, IC018A IC019A, IC033 IC069A, IC070A IC071A Coax Twisted Pair Balun Coax Twisted Pair Balun w/cable Mini Coax Twisted Pair Balun CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com E-mail: info@blackbox.com

FEDERAL COMMUNICATIONS COMMISSION RADIO FREQUENCY INTERFERENCE STATEMENT This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be required to correct the interference. Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. This digital apparatus does not exceed the Class A limits for Radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada. Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique édicté par Industrie Canada. TRADEMARKS IBM and ROLM are registered trademarks of IBM Corporation. Memorex is a registered trademark of Memorex Corporation. Harris is a registered trademark of Harris Corporation. Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners. 2

Table of Contents 1. Specifications...4 2. Introduction...6 3. Installation, Operation, and Troubleshooting...8 3.1 Balun Installation...8 3.2 Cabling...8 3.3 Common Cable Problems...9 3.4 Troubleshooting...12 3

1. Specifications System Environments IBM 3270, ITT, Harris, Memorex, AT&T, Lee Data, and other Type A-compatible devices NOTE: These baluns cannot be used in an Ethernet environment. Connectors IC002: (1) male BNC connector; (2) screw terminals IC018A: (1) male BNC connector; (1) male RJ-11 connector at the end of a 15-foot cable. IC019A: (1) male or female BNC connector; (1) female RJ-11 connector IC033: (1) male BNC connector; (1) female RJ-11 connector IC069A: (1) male BNC connector; (1) female RJ-45 connector IC070A: (1) male BNC connector; (1) female RJ-45 connector IC071A: (1) male BNC connector; (1) female RJ-11 connector Pin Configuration IC002: Pins 3 and 4 IC018A: Pins 3 and 4 IC019A: Pins 3 and 4 IC033: Pins 2 and 5 IC069A: Pins 4 and 5 IC070A: Pins 1 and 2 IC071A: Pins 3 and 4 Data Format Speed 3270 Type A coax 2.358 Mbps Temperature Operating: 32 to 131 F (0 to 55 C) Storage: -4 to 185 F (-20 to 85 C) Humidity 95% non-condensing 4

Table 1. Data Transmission Parameters Wire Gauge Distance DC Resistance Capacitance 22 1500 feet 33 ohms/1000 feet 0.016 µfd/1000 feet 457 meters 33 ohms/305 meters 0.016 µfd/305 meters 24 1200 feet 52 ohms/1000 feet 0.016 µfd/1000 feet 366 meters 52 ohms/305 meters 0.016 µfd/305 meters Power None required Size IC002: 0.6"W x 2.3"D (1.5 x 5.8 cm) IC018A: 1"W x 2.8"D (2.5 x 7.1 cm) IC019A: 1"W x 2.8"D (2.5 x 7.1 cm) IC033: 1.8"H x 1"W x 0.6"D (4.6 x 2.5 x 1.5 cm) IC069A: 1.8"H x 1"W x 0.6"D (4.6 x 2.5 x 1.5 cm) IC070A: 1.8"H x 1"W x 0.6"D (4.6 x 2.5 x 1.5 cm) IC071A: 1.8"H x 1"W x 0.6"D (4.6 x 2.5 x 1.5 cm) 5

T R Coaxial Baluns Coax-to-twisted-pair baluns allow a controller or host computer to communicate with peripheral devices over twisted-pair cables. Twisted-pair is easier to install and less costly than coaxial cable. NOTE: These coaxial baluns cannot be used in an Ethernet environment. Table 1 shows the maximum distance you can expect from twisted-pair cable. This maximum distance varies depending on the number of breaks and the type of wire used. The cable must be unshielded, low capacitance twisted pair. See Section 3.2 for a full description and recommendations for your cabling. If you need to run your cable beyond the 2. Introduction recommended distance, you might be able to use a repeater. The RJ-11 connection uses the naming convention of tip and ring. These are terms that have been passed down from the old telephone system. An operator would plug in a patch between two ports. The end of the plug (the tip ) was the live connection. There was a black band around the plug for grounding. This was the ring line. Tip and ring have since become associated with a dial connection. Since RJ-45 connectors do not use a dial connection there are no references to tip and ring when these connectors are used. T R Twisted pair This would be attached to a 3270 terminal or printer This would be attached to a 3270 terminal or printer Wall phone jacks 1200ft. of 24 gauge twisted pair Figure 1. You can use the existing twisted-pair cable in your building when you install baluns. 6

3270 Terminal 3270 Cluster Controller Coax Twisted Pair Balun Coax Twisted Pair Balun T R RJ-11 Connectors R T Screw terminal Twisted-pair cable Screw terminal Figure 2. Typical installation for the Coax Twisted Pair Balun (Single Port Configuration). A twisted-pair cable can utilize the screw terminal or the RJ-11 connector at either end. In this example, the screw terminals are utilized. 7

3. Installation, Operation, and Troubleshooting 3.1 Balun Installation To install the balun, connect one end to the IBM controller s coaxial port. Connect the other end of the balun to the twisted-pair cable with with an RJ-11 connector, RJ-45 connector, or screw terminal (dependent upon which Balun you have purchased). At the other end of the communications link, connect the second balun to the device s coaxial port and to the twisted-pair cable. The cable must be wired straight-through. 3.2 Cabling UNSHIELDED VS. SHIELDED TWISTED- PAIR CABLE We recommend that unshielded cable be used to wire a building for data transmission. For optimal results, we recommend the use of EYN712A or its equivalent. The cable should be 24 AWG (or lower) solid copper twisted-pair unshielded cable that meets the following specifications: Nominal Impedance: 100 ohms at 1 MHz Maximum Capacitance: 20 pf/foot Maximum Attenuation: 6.6 db/1000 ft. at 1 MHz If you are using unshielded cable that does not have the electrical characteristics specified above, the distances listed in Table 1 may be lower. Shielded cable is not recommended because it usually has high nominal impedance. This may create impedance mismatch on the line. When using a shielded cable, the shield must be grounded from one end of the connection to the other. If this is not done, the shield will act as an antenna and pick up electromagnetic or radio-frequency interference. Unless you are using lowcapacitance shielded wiring, your cable will have a much greater capacitance than 20 pf/foot, resulting in greater signal attenuation and shorter distance capability. Maximum attainable distance for shielded cable is a third of its rated distance. SOLID COPPER VS. STRANDED WIRES We suggest the use of solid copper over stranded wire because stranded wire has a capacitance higher than 20 pf/foot. The capacitance of stranded wire is, however, lower than that of shielded cable. The use of stranded cable is acceptable, but it will not be as efficient as solid copper wire for achieving maximum distances. 8

FLAT RJ-11 CABLE The use of flat satin cable (telephone extension cords) is recommended only for patching purposes. When flat cable is used, maximum length between the controller and any terminal should not exceed 15 feet (4 m). If possible, try to use twisted-pair wiring instead of flat cable. Flat cable is not considered to be a reliable transmission medium. IBM TYPE 1 AND 2 CABLE With these baluns, you cannot convert coax cables to IBM Type 1 and 2 cable. USE OF RISER CABLES When you use riser cables containing more than 25 pairs, we recommend that these be arranged in binder groups. Each group should have a maximum of 25 pairs. This will minimize crosstalk between the different pairs. Do not split pairs when making connections. A pair is two wires that share the same colors. For example, White-base and Blue- band wire form a pair with Blue- base and Whiteband wire. CABLE LENGTH EVALUATION For every connection a cable passes through, there is often a slight loss of signal strength. Such connections include 66 blocks and patch panels. Each connection subtracts approximately 10 feet from the maximum attainable distance. The following equation can be used to estimate the effective length of a twisted-pair run: C = A + (B * 10 feet) Where: A = Physical length of cable in feet B = Number of breaks in the cable loop C = Effective cable length for the system in feet For example, if you wish to run 30 feet of cable (A) and have 7 connections in the cable loop, the effective length for the system would be 100 feet. C = 30 + (7 * 10 feet) 3.3 Common Cable Problems This section outlines the common errors associated with wiring cable: incorrect pinouts reverse signal polarity loss of continuity interface problems MODULAR JACK PIN-OUT Figure 3 illustrates modular jack pinout conventions for RJ-11. The standard is Pin 3 for Ring and Pin 4 for Tip. This is a straight-pinned cable. 9

Telephone wiring systems usually take Pins 3 and 4 for voice and data transmission. Some wiring systems, like ROLM, use Pins 3 and 4 for voice and Pins 2 and 5 for data so as to prevent a user from accidentally plugging a data terminal into a voice line and damaging the equipment. It is important to verify that the pin configuration of the baluns corresponds to the pin configuration used in the building s wiring scheme. Figure 4 illustrates modular jack pinout conventions for an RJ-45 straight-pinned cable. POLARITY PROBLEMS Baluns are polarity sensitive. Cables must be wired straight-through as in Figure 3 (Tip to Tip and Ring to Ring) and Figure 4. Data will not be transmitted if there are crossovers on the cable. If your terminal will not work, and distance is within specified limits, try reversing Tip and Ring at one of the baluns. Pin 1 B R G Y Pin 6 Pin 1 B R G Y Pin 6 L E RE E L E RE E A D LL A D LL C E C E K N K N O W O W T R RJ11 Green (tip) pin4 BNC Tip Ring Red (ring) pin3 Figure 3. Modular jack pin-out conventions for RJ-11. 10

Pin 1 Pin 8 Pin 1 Pin 8 B L U E O RA N G E B L A C K R G Y B E RE E R D LL O E W N O N W S L A T E B L U E O RA N G E B L A C K R G Y B E RE E R D LL O E W N O N W S L A T E Figure 4. Modular jack pin-out conventions for RJ-45. DC LOOP RESISTANCE TEST One way to verify the continuity of your link is to perform a DC Loop Resistance Test. This will tell you if you have exceeded the total distance for your cable or if your link is bad (short circuits, open circuits, loose connections, or badly crimped connectors, etc.). Figure 5 shows how to perform the DC Loop Resistance Test with the help of a multimeter set at the Ohm position. Make sure that the two wires at the opposite end of the the multimeter are shorted together. Table 2 illustrates the different resistance values for various cable types and distances. Ω Red Computer room Drop side Chm Ohmmeter meter Green Twisted pair Figure 5. DC Loop Resistance Test. 11

Table 2. Typical Cable DC Resistances DC Loop Resistance (Ohms) DC Resistance Cable Size per 1000 feet 600' 1200' 2400' 3000' 3500' 22 AWG 16.0 Ohms 19 38 77 96 112 24 AWG 26.0 Ohms 31 62 125 156 182 NOTE: Baluns do not maintain DC continuity. If an ohmmeter is used, the balun will appear to be shorted from Tip and Ring. The coax pins will also appear to be shorted. This is normal. INTERFERENCE PROBLEMS When installing cable, try to avoid all sources of electromagnetic interference such as fluorescent lighting, high power lines, electric motors and power transformers. Data wiring should be at least: 5" (12.7 cm) from power lines of 2 KVA or less; 12" (30.5 cm) from fluorescent lighting and power lines between 2 and 5 KVA; 36" (91.4 cm) from power lines greater than 5 KVA; 40" (101.6 cm) from transformers and motors. 3.4 Troubleshooting GENERAL TROUBLESHOOTING Data transmission in the IBM 3270 environment is done via Manchester encoding at a frequency of 2.358 Mbps. At the output of the controller and the terminals, the amplitude of the signal is 2.5 Vp-p. For the controller to decode the terminal signal (and for the terminal to decode the controller signal), the minimal amplitude required is 500 MVp-p at each end. In case of data transmission problems, refer to the following checklist: Are the controller ports working correctly? Are the data terminals working correctly? Has the cable distance been exceeded? Is signal polarity reversed? If an oscilloscope is available, is the signal from the controller at least 500 MVp-p at the terminal side? 12

TROUBLESHOOTING IN THE 3270 ENVIRONMENT Check the following when installing baluns in the IBM 3270 environment: 1. Signal polarity reversal: Switch the wires on the RJ-11 connector or on the hardwire (screw-type) terminals at one end of the line. Make sure the cable is straightpinned (tip to tip, ring to ring). See Figures 3 and 4 on pages 10 and 11. 2. Verify that twisted-pair wires are connected to the correct pins of the balun. Check the pin configuration and correct if necessary. 3. Check for and eliminate open or short circuits on the line. 4. Exceeded distances: To verify if distance is being exceeded, a DC Loop Resistance Test should be performed (see Section 3.3, pages 11 and 12, for a full explanation). 13

Copyright 1993. Black Box Corporation. All rights reserved. 1000 Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax 724-746-0746