Air Conditioners for Cabinets

Similar documents
Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

STULZ the natural choice. Tel-Air-2 Series. Telecom Line

CRAC Precision climate control units for data centres

ECOCIAT. Domestic hot water heat recovery unit

5-21kW. Ecotel Indoor Range. - 21kW. > Ecotel Indoor Range. Typical Applications

Refrigerators - Freezers. Ekofrigolab & Ekobasic Series

IT Cooling Solutions. Wall-Air Series Displacement Evolution. Telecom-Line

STULZ View On DataCenter Cooling

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Hiwall Hiross for Telecom. High Performance Air Conditioning

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Intelligent control system with integrated electronic expansion valves in an air-conditioning system operating at a Telecom telephone exchange

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

york air-conditioning products Residential & VRF News 2015

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Unico Inverter. Unique and efficient.

NetXtend Flex Series Integrated Outdoor Enclosure Solution. Outside Plant for Business-Critical Continuity

Refrigeration Compressed Air Dryer Buran Ultrapulse

PIEZOMETER AIRFLOW MEASURING RING

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Freezers - Ultrafreezers. Platilab & Irilab Series

EHDC. Cooling system for Data Center and server cabinets.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

JAWAHARLAL NEHRU UNIVERSITY

Split units TH with hermetic compressors

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

IT Cooling Solutions. DFC² Direct Free Cooling for Data Centres. Energy-efficient, reliable and available around the world

Bring the fresh in. Dedicated Outside Air Systems

Number 1 in efficiency

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

FTQ. Daikin Inverter Ducted Heat Pump

Specifying a Variable Frequency Drive s

Chilled Water Precision Air Conditioner For Critical Application

RPV - RP - RA air handling units

Page 1 / 14 Groupe MOBILITECHMIOSBOX Technical Specification MWP-DT1010. Technical specifications

Phase Modular Finally the benefits of Modular ups are for all

Thyristor-controlled power supplies and battery chargers

PD 100A. Printing data system

FULL DC INVERTER SYSTEMS

Important Safeguards

IntesisBox KNX Mitsubishi Heavy Industries AC

CoolTeg Plus Chilled Water (CW) version: AC-TCW

BROWACOM PRODUCTS. Our web-pages can be found from:

HYBRID POWER SYSTEMS for TELECOM applications

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

IntesisBox KNX LG Air Conditioning

SECTION MORTUARY REFRIGERATORS

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Rotary screw compressors kw 5,5 7, , bar MODULO

CB200W Water Leak Detection Panel Application Guide

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Understand Hybrid Generator Battery Systems

Energy Saving ECM Motors and Fans Ventilation Catalogue

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

Modbus Server SAMSUNG Air Conditioners

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

IV. Rear Mount System

CE6500 Energy Recovery Ventilator

AIS750 Series Alarm Annunciator

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Cooling kw Heating kw

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

14. Troubleshooting Guide

HEATER, AIR CONDITIONING AND VENTILATION

Frequency Converter Fv

IT Cooling Solutions. DFC² Direct Free Cooling for Data Centres. Energy-efficient, reliable and available around the world

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Under sill units. Type FSL-B-ZAS

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Cool Design for Homes and Offices

A-307. Mobile Data Terminal. Android OS Platform Datasheet

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

MAJORSINE Power Inverter

Submitted to Reference Approval Construction Unit Designation Schedule #

Permissible ambient temperature Operation Storage, transport

ECO-AIR AIR CONDITIONING

... Electronic Softstarter...

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

SPECTRACOOL AIR CONDITIONERS PENTAIR EQUIPMENT PROTECTION MCLEAN IS NOW HOFFMAN COOLING

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

SECTION DETECTION AND ALARM

ThermoStar Refrigeration Air Dryers

Basic Technology Series

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

Uninterruptible Power Supply

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Intelligent RS-485 I/O expansion unit: RU-87Pn Series

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

Transcription:

PREDATOR EVOLUTION

Air Conditioners for Cabinets STULZ with Predator Evolution line offers you a complete range of professional air conditioners for telecom shelters and other enclosures. Predator Evolution line includes the AC powered version and the 48VDC version. The 48VDC version is particularly suitable for telecom cabinets powered by renewable energy sources, such as solar or windpower, or to be powered by battery backup, so is not necessary to use an inverter. In addition the units can also have a Free Cooling system, which allows a further considerable reduction of energy costs. D-mark DEMKO CERTIFICATE

Predator Evolution is available with or without a Free Cooling system. Both versions can be installed: inside the cabinets, when there s the need to protect the air conditioner; outside, to use the full space inside the cabinet; in semi-recessed position with the fixing frame accessory. FREE COOLING COMPRESSOR Free Cooling The telecommunications airconditioning is essential for the continuity of the data flow, but the traditional comfort air-conditioners absorb more than 30% of the total amount of energy. The STULZ energy-efficient air-conditioning solutions, based on direct Free Cooling, provides the best solution for energy costs saving. Due to the direct use of external air, whenerver it is at a lower temperature than the inside, the telecommunications sites cooling is for free. In free cooling the intake fan is the only component in use; the compressor, energy-intensive element, is only switched when absolutely necessary.

Predator evolution Predator Evolution is available: without free cooling; with free cooling without emergency fan; with free cooling and emergency fan at 48V in DC. Predator line common details: housing of galvanised, powder coated sheet steel; refrigerant R134a; semi-flush mounting IP54 protection degree (IP55 optional) air filter with G4 efficency class hermetic reciprocating compressor with internal electrical protection; exchange pack in copper-aluminium; capillary expansion; refrigerant drier filter; power supply bi-frequency 50-60Hz; electronic control C100 on board; Safety pressure switchs for high and low pressure vandalism protection; remote monitoring: communication through serial line with STULZ and Modbus protocols for the customer BMS connection or gateway STULZ MIB and WIB. CODE PRT100 PRT10F / PRT10H** PRT140 PRT14F/ PRT14H** PRT200 PRT20F/ PRT20H** COOLING CAPACITY L35L35 W 1000 1000 1400 1400 2000 2000 EXTERNAL OPERATING CONDITIONS INTERNAL OPERATING CONDITIONS C -20 +60-20 +60-20 +60-20 +60-20 +60-20 +60 C +25 +45 +25 +45 +25 +45 +25 +45 +25 +45 +25 +45 EXTERNAL NOISE LEVEL* db(a) 55 55 55 55 58 58 POWER SUPPLY V/ph/Hz 230/1/50-60 230/1/50-60 + 48VDC 230/1/50-60 230/1/50-60 + 48VDC 230/1/50-60 230/1/50-60 + 48VDC HEIGHT mm 955 1200 955 1200 955 1200 WIDTH mm 417 417 417 417 417 417 DEPTH mm 300 300 300 300 300 300 *Measured at 2 m distance from unit, free-field, working in cooling mode at nominal conditions ** Units with Free Coolig

C100: an intelligent control for energy saving C100 is the Predator Evolution microprocessor electronic control. It consists in an internal I/O card; it s also possible to connect a keypad with display, wall mounted, to display information and change the adjustment parameters. Working ways direct expansion cooling, activating the compressor; free cooling, through the modulation of the damper integrated in the conditioner, adjusting the free cooling capacity to the inside thermal load; emergency ventilation, when the principal supply is missing and the evaporator fans are at 48 VDC heating, if the units have electric resistors. Energy saving the speed of the evaporator fan can be decreased to a set value whenever there s no need of the heating and neither of cooling. adjustment to variable outside temperatures; the condenser fan adjusts its speed to steady the condensation temperature, always guaranteeing maximum efficiency with the change of external temperature; hot working: special function to favour the compressor start under conditions of critical temperatures, typical of the start-ups in warm geographical areas. Single Alarm Management each alarm can be addressed to one of the two control digital exits, in order to supply to the external supervision PLC a free voltage signal; it s possible to set-up each alarm in 5 gravity levels, and choose an automatic, manual (service intervention needed) or mixed reset. External devices connection Two digital outputs available to send remote enabling signals or smoke-fire to the C100, through external devices. Simplified Start-up Semiautomatic function to test the correct components running, simplifying the start-up operations. Parameters Setting the parameters are organized in a tree menu, divided in component / functions, to simplify the configuration; the single parameters are protected by 3 levels of password: user, service, manufacturer. Flash EPROM to simplify the software configuration and updating planning of the units through laptop; hardware key to upload and download the software without a laptop and to copy quickly the configuration on other units.

Predator evolution in 48V DC Predator Evolution 48VDC is available: without free cooling; with free cooling and emergency fan at 48V in DC. Predator 48VDC common details: 48VDC continuously variable speed compressor with built in Soft Start, which reduces excess current during initial power-up. housing of galvanised, powder coated sheet steel; refrigerant R134a; semi-flush mounting (optional) IP54 protection degree (IP55 optional) air filter with G4 efficency class hermetic reciprocating compressor with internal electrical protection; exchange pack in aluminium; capillary expansion; refrigerant drier filter; power supply 48 V DC; electronic control C110 on board; Safety pressure switchs for high and low pressure vandalism protection; CODE PRT100D PRT10FD** PRT200D PRT20FD** COOLING CAPACITY L35L35 W 1000 1000 2000 2000 EXTERNAL OPERATING CONDITIONS INTERNAL OPERATING CONDITIONS C -20 +60-20 +60-20 +60-20 +60 C +25 +45 +25 +45 +25 +45 +25 +45 EXTERNAL NOISE LEVEL* db(a) 55 55 58 58 POWER SUPPLY V DC 48 48 48 48 HEIGHT mm 955 1200 955 1200 WIDTH mm 417 417 417 417 DEPTH mm 300 300 300 300 *Measured at 2 m distance from unit, free-field, working in cooling mode at nominal conditions ** Units with Free Coolig

C110 Electronic Control C110 is the Predator Evolution 48VDC microprocessor electronic control. It consists in an internal I/O card; it s also possible to connect a keypad with display, wall mounted, to display information and change the adjustment parameters. C103 micorprocessor controls the condensator fan, the evaporator fan and the compressor. Working ways direct expansion cooling, activating the compressor; free cooling, through the modulation of the damper integrated in the conditioner, adjusting the free cooling capacity to the inside thermal load; emergency ventilation, when the principal supply is missing and the evaporator fans are at 48 VDC Energy saving the speed of the evaporator fan can be decreased to a set value whenever there s no need of the heating and neither of cooling. adjustment to variable outside temperatures; the condenser fan adjusts its speed to steady the condensation temperature, always guaranteeing maximum efficiency with the change of external temperature; hot working: special function to favour the compressor start under conditions of critical temperatures, typical of the start-ups in warm geographical areas. Simplified Start-up Semiautomatic function to test the correct components running, simplifying the start-up operations. Parameters Setting the parameters are organized in a tree menu, divided in component / functions, to simplify the configuration; the single parameters are protected by 3 levels of password: user, service, manufacturer. Flash EPROM to simplify the software configuration and updating planning of the units through laptop; hardware key to upload and download the software without a laptop and to copy quickly the configuration on other units.

Stulz S.p.A. Cosmotec Industrial Cooling Via Torricelli, 3 37067 Valeggio sul Mincio (VR) Phone: +39 (045) 633 16 00 Fax: +39 (045) 633 16 35 info@stulz.it www.stulz.it