SRCM Room Condition Monitor

Similar documents
BACnet protocol implementation conformance statement. Corrigo

PIEZOMETER AIRFLOW MEASURING RING

ROAMview to BACnet IP Software Module

BACnet Protocol Implementation Conformance Statement

COMMUNICATION PROTOCOL pag. 1/7. BACnet Protocol Implementation Conformance Statement

WD-AMX Water Detection Controllers

SHEET. BASautomation. BAS Router BACnet Multi-Network Router. BAS Router

Electronic Control Devices The European Product Catalogue 2007

HMI display Installation Guide

BACnet Protocol Implementation Conformance Statement. Gebäudeautomationssystem Creative Automation Line

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Carbon Monoxide (CO) Gas Detection and Control System

Duct Humidity Transmitter

Electronic Control Devices The European Product Catalogue 2007

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

3500/93 System Display

TrueAlarm Fire Alarm Systems

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

TrueAlarm Fire Alarm Systems

PRODUCT PROFILE FEATURES

How To Use A Ds340 (Dsp)

Digital input modules

BACnet. bcx1 Controller/ Router Series

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

TX OPEN RS232/485 module

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Rackmount Intelligent Pressure Scanners

FX07 Field Controller

Tracer Summit Web Server

SAUTER BACnet PICS EY-modulo 5 moduweb500 BACnet Protocol Implementation Conformance Statement

Healthcare Solutions Room Pressure Monitors and Controls

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

GUIDE. CTRLink. EIPR Skorpion Wired and Wireless IP Routers. EIPR Series

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

AIS750 Series Alarm Annunciator

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

USB-500/600 Series Low-Cost Data Loggers and Accessories

DUCT SMOKE DETECTOR D4120

FX07 Field Controller

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Temperature & Humidity SMS Alert Controller

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Uninterruptible Power Supply

Dokumentationen für BACnet-Geräte - PICS

Panel Meters and Controllers Modular Panel Meter Type EDM 35

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

DPI 260 SERIES: Digital Pressure Indicators

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

UniOP epad33 and epad33t

POWERS CONTROL RC 195 Single Input Receiver-Controller

T7079A,B Solid State Remote Temperature Controllers

CAMS. Combustion Airflow Management System. Proven solutions for a tough industry

TAC I/NETTM MR-AHU-HP. Application Specific Controller

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

Electronic Pressure Switch EDS 300

DATA/SPEC SHEET VIRTUAL MATRIX DISPLAY CONTROLLER VERSION 8

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Rosemount 333 HART Tri-Loop

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Repeaters and Mimics Data Sheet

Model SRMD Setra Remote Monitoring Display

CONSTRUCTION STANDARDS DIVISION 23 HEATING VENTILATING AND AIR CONDITIONING

Insight Advanced Workstation

Rosemount 333 HART Tri-Loop

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

CPA PC-Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips

Thyristor-controlled power supplies and battery chargers

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

Features. Introduction. Applications. VPD-130/VPD-130N with DIN-Rail Mounting. VPD-130/VPD-130N Panel Mounting. Excellent C/P ratio (cost/performance)

Indoor / Outdoor Antenna

DIVISION 28 ELECTRONIC SAFETY AND SECURITY SECTION SECURITY AND ACCESS CONTROL SYSTEM

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Powers Controls TH 192 S Single Temperature Room Thermostat

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

RC 195 Multiple Input Receiver-Controller

USB-500/600 Series Low-Cost Data Loggers and Accessories

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL CAUTION CONNECTION DIAGRAM

Product Specification instalert Rapid Messenger Variable Message Sign

VSO MAX HP High Flow Proportional Valve

Climate Ready Control Systems Technical Specifications

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Telefon (+45) Telefax (+45) Installation and operating manual

Fire Control Panels. Remote Annunciator Panels. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features. Introduction

Portable BACnet /IP to MS/TP Router

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Y7230A CO 2 Alarm System

Transcription:

Technical Specification Sheet Document No. 149-211 September 22, 2014 SRCM Room Condition Monitor Description In a hospital, laboratory, or animal research facility, the integrity of the ventilation control system is at the heart of a contaminant-free environment. Whether a room is to be maintained at a negative pressure to prevent contaminants from escaping into adjacent areas or positive pressure to protect patients with compromised immune systems, the proper pressurization of the room is essential. To assure proper pressurization is maintained in these critical environments, a room pressure monitor is employed to measure and alert staff and personnel of any change in pressure no matter how small. A fail-safe solution to monitoring these very low pressure changes is the Model SRCM Room Condition Monitor, which uses highly accurate capacitance sensing technology to measure and display true low pressure differential to a resolution of 0.00001. in water column (WC). Features High resolution color touch-screen display o Immediate feedback on room status o Intuitive graphic interface "Two-in-One" eliminates the need for a second monitor o Display both pressure and room condition o On-board and remote sensing capability Flush-mount design o Low profile, easy-care wipe down o Snap-in cover plate no visible fasteners o Face is sealed for cleaning or wipe-down True pressure measurement o High accuracy low differential capacitance technology o Dead ended solution no contamination or clogging o Standard on-board sensor and optional remote sensor "two measurements in one" o Pressure ranges between +- 0.05" WC and +/- 5.00" WC o Clone configuration capability o Standard off-the-shelf electrical box Ease of installation o Mounts in off-the-shelf electrical gang box o Four-screw, self-leveling mount o Labeled, removable termination strips ease of wiring Clone configuration o Cloning of configurations for multiple unit installation using USB port Multiple Communications Options o BACnet MSTP o Siemens P1 Alarm capabilities o Local audible and visual alarming o Remote annunciator alarming capability o Alarm delay feature prevent nuisance alarms Multiple Room Support o The SRCM can be used to display the status of two rooms. o Second pressure sensor is required Page 1 of 8

Applications Surgical suites Intensive care isolation rooms Research laboratories Pharmaceutical Organic laboratories Animal research facilities Fingertip Access for Easy Setup Setup Display Banner o User-Defined Text: Free form data entry from room name Setup Display Advanced o Display Contrast: Change brightness of display o Display Averaging: Improve display resolution in unstable ambient pressure environments o Displayed Pressure: Display primary and secondary or toggle between two rooms o Enable Password: Administrator and Supervisor Setup Unit Operation o Setup primary and secondary room o Change analog output o Free form data entry for room name o Room Status: Change room from Isolation to No Isolation Specifications Performance Data +/- 0.25 Full Scale +/- 0.50 Full Scale Accuracy RSS* +/- 0.25% +/- 0.50% (at contestant temperature) Non-linearity (BFSL based) +/- 0.24% +/- 0.49% Hysteresis +/- 0.05% +- 0.05% Non-repeatability +/- 0.05% +/- 0.05% Zero setting tolerance +/- 0.5% FS +/- 0.5% FS Thermal Effects** Compensated range F ( C) Overpressure +/- 0.03% FS (+/- 0.05% FS) +/- 1 PSI (15" WC for < 0.10" WC FS) * RSS of non-linearity, non-repeatability and hysteresis ** Units calibrated at nominal 70 F. Maximum thermal error computed from this datum. Environmental Data Temperature Operating* 32 F to 120 F (0 to 50 C) Storage -20 F to 160 F (-30 C to 70 C) Operating humidity 5% to 95% RH (non-condensing) * Operating temperature limits of the electronics only. Pressure Media Air or non-conductive, non-explosive gases Physical Description Case Fire retardant plastic UL94 V-0 Dimensions 5.84" H 7.45" W 0.38" D (14.84 cm 18.92 cm 0.95 cm) Electrical connection Pressure fittings Weight (approximate) Mounting Removable terminal block Barbed fittings for 1/4" tubing 1 lb 3.2 oz (554 grams) Mounts to triple gang, double-deep electrical box Page 2 of 8

Specifications (Continued) Communications BACnet MS/TP ASC Option Siemens P1 Display LCD 4.3" TFT, 480 272, dimmable Electrical Data Circuit 3-wire (Exc, Out, Com) (Voltage) Output* 0 to 5 Vdc, 0 to 10 Vdc Excitation 18 to 32 Vac, 50 to 60 Hz Power consumption 10W maximum, 3 W typical Alarm output SPDT relay: 0.6A @ 120 Vac 2A @ 30 Vdc D/A Resolution 14-bit * Calibrated into a 50K ohm load, operable into a 5000 ohm load or greater Electrical Data Circuit 2-wire (Current) Output 4 to 20 ma External load 0 to 510 ohms Excitation 18 to 32 Vac D/A Resolution 14-bit Inputs 1 internal pressure sensor 2 A/D's inputs for remote pressure sensors, temperature and humidity sensors (Resolution 16-bit) 1 digital input (door contact dedicated) Certifications CE Electro-magnetic Compatibility Directive 2004/108EC Ordering Information Product Number Pressure Range Protocol Accuracy (Full Scale) 547-310A +/- 500 Pa P1 0.5% 547-311A +/- 0.05" WC (12.5 Pa) P1 0.5% 547-312A +/- 0.10" WC (25 Pa) P1 0.5% 547-313A +/- 0.25" WC (62.5 Pa) P1 0.5% 547-314A +/- 0.50" WC (125 Pa) P1 0.5% 547-315A +/- 1.00" WC (250 Pa) P1 0.5% 547-316A +/- 2.50" WC (625 Pa) P1 0.5% 547-317A +/- 5.00" WC (1250 Pa) P1 0.5% 547-318A +/- 50 Pa P1 0.5% 547-319A +/- 100 Pa P1 0.5% 547-310B +/- 500 Pa P1 0.25% 547-311B +/- 0.05" WC (12.5 Pa) P1 0.25% 547-312B +/- 0.10" WC (25 Pa) P1 0.25% 547-313B +/- 0.25" WC (62.5 Pa) P1 0.25% 547-314B +/- 0.50" WC (125 Pa) P1 0.25% 547-315B +/- 1.00" WC (250 Pa) P1 0.25% 547-316B +/- 2.50" WC (625 Pa) P1 0.25% 547-317B +/- 5.00" WC (1250 Pa) P1 0.25% 547-318B +/- 50 Pa P1 0.25% 547-319B +/- 100 Pa P1 0.25% 547-320A +/- 500 Pa BACnet 0.5% 547-321A +/- 0.05" WC (12.5 Pa) BACnet 0.5% 547-322A +/- 0.10" WC (25 Pa) BACnet 0.5% 547-323A +/- 0.25" WC (62.5 Pa) BACnet 0.5% 547-324A +/- 0.50" WC (125 Pa) BACnet 0.5% 547-325A +/- 1.00" WC (250 Pa) BACnet 0.5% 547-326A +/- 2.50" WC (625 Pa) BACnet 0.5% 547-327A +/- 5.00" WC (1250 Pa) BACnet 0.5% 547-328A +/- 50 Pa BACnet 0.5% 547-329A +/- 100 Pa BACnet 0.5% 547-320B +/- 500 Pa BACnet 0.25% 547-321B +/- 0.05" WC (12.5 Pa) BACnet 0.25% 547-322B +/- 0.10" WC (25 Pa) BACnet 0.25% Page 3 of 8

Ordering Information (Continued) Product Number Pressure Range Protocol Accuracy (Full Scale) 547-323B +/- 0.25" WC (62.5 Pa) BACnet 0.25% 547-324B +/- 0.50" WC (125 Pa) BACnet 0.25% 547-325B +/- 1.00" WC (250 Pa) BACnet 0.25% 547-326B +/- 2.50" WC (625 Pa) BACnet 0.25% 547-327B +/- 5.00" WC (1250 Pa) BACnet 0.25% 547-328B +/- 50 Pa BACnet 0.25% 547-329B +/- 100 Pa BACnet 0.25% Accessories Annunciator Tap Plate Specifications Specifications Enclosure: 2.75 in. W 4.5 in. H (69.85 mm W 114.3 mm H) Dimensions: 2.75 in. W 4.5 in. H (69.85 mm W 114.3 mm H) External Supply: 15 Vdc, 50 ma max. Materials: Stainless Steel Display Panel: Green and red LED indicators, and Acknowledged Switch Mounting: Wall mounting using a standard electrical box Audible Alarm: 0 to 85 dba measured 4 inches from Annunciator Acknowledge Switch: Momentarily turns off the audible alarm. Product Number Description 547-199 RPM Remote Annunciator Module 547-100 RPM Pressure Tap Plate Information in this document is based on specifications believed correct at the time of publication. The right is reserved to make changes as design improvements are introduced. Product or company names mentioned herein may be the trademarks of their respective owners. 2014 Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 USA +1-847-215-1000 Your feedback is important to us. If you have comments about this document, please send them to sbt_technical.editor.us.sbt@siemens.com. Document No. 149-211 Printed in the USA Page 4 of 8

BACnet Protocol Implementation Conformance Statement Products Product Model Number Protocol Revision Siemens SRCM Room Pressure Monitor 547-320A, 547-321A, 547-322A, 547-323A, 547-324A, 547-325A, 547-326A, 547-327A, 547-328A, 547-329A, 547-320B, 547-321B, 547-322B, 547-323B, 547-324B, 547-325B, 547-326B, 547-327B, 547-328B, 547-329B Revision 4 (135-2004) Vendor Information Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089 www.buildingtechnologies.siemens.com/bt/us Product Description In a hospital, laboratory, or animal research facility, the integrity of the ventilation control system is at the heart of a contaminant-free environment. Whether a room is to be maintained at a negative pressure to prevent contaminants from escaping into adjacent areas or positive pressure to protect patients with compromised immune systems, the proper pressurization of the room is essential. To assure proper pressurization is maintained in these critical environments, a room pressure monitor is employed to measure and alert staff and personnel of any change in pressure no matter how small. A fail-safe solution to monitoring these very low pressure changes is the Model SRCM Room Pressure Monitor, which utilizes highly accurate capacitance sensing technology to measure and display true low pressure differential to a resolution of 0.00001. in water column (WC). BACnet Standardized Device Profile Product SRCM Device Profile BACnet Application Specific Controller (B-ASC) Supported BACnet Interoperability Building Block (BIBBs) Product BIBB Name Required for B-ASC Profile SRCM DS-RP-B Data Sharing-ReadProperty-B DS-WP-B DM-DDB-B DM-DOB-B DM-DDC-B Data Sharing-WriteProperty-B Device Management-Dynamic Device Binding-B Device Management-Dynamic Object Binding-B Device Management-DeviceCommunicationControl-B Page 5 of 8

Supported BACnet Interoperability Building Block (BIBBs), Continued Product BIBB Name Not Required for B-ASC Profile but supported in RPM SRCM DS-RPM-B Data Sharing-ReadPropertyMultiple-B DM-RD-B DS-WPM-B AE-N-I-B AE-INFO-B DM-TS-B DM-DDB-A DB-UTC-B DS-RP-A DS-WP-A Device Management-ReinitializeDevice-B Data Sharing Write Property Multiple-B Alarm and Event-Notification Internal-B Alarm and Event-Information-B Device Management Time Synchronization-B Device Management Dynamic Device Binding-A Device Management UTC Time Synchronization-B Data Sharing Read Property-A Data Sharing Write Property-A Standard Object Types Supported Product Object Type Creatable Deletable SRCM Analog Input No No Analog Value No No Binary Input No No Binary Value No No Device No No Event Enrollment No No Multi-State Input No No Multi-State Value No No Notification Class No No Proprietary Character String Value No No Data Link Layer Options Product SRCM Data Link and Options MS/TP master (Clause 9), baud rate(s): 9600 bps, 19200 bps, 38400 bps, 76800 bps Page 6 of 8

Segmentation Capability Product Segmentation Type Supported Window Size: 32 (MS/TP product limited to 1) SRCM Can transmit segmented messages No Can receive segmented messages No Device Address Binding Product SRCM Static Device Binding Supported No Networking Options Product Network Options Supported Supported SRCM Router, Clause 6: No Annex H, BACnet Tunneling Router over IP BACnet/IP Broadcast Management Device (BBMD) Does the BMD support registrations by Foreign Devices? No No Character Sets Product Charcter Sets Supported SRCM ANSI X3.4 Supported Services Product Application Service Initiates Requests Executes Requests SRCM ConfirmedEventNotification Service Yes No UnconfirmedEventNotification Service Yes No GetEventInformation Service No Yes ReadProperty Service Yes Yes ReadPropertyMultiple Service No Yes WriteProperty Service Yes Yes WritePropertyMultiple Service No Yes DeviceCommunicationControl Service No Yes ReinitializeDevice Service No Yes Timesynchronization Service No Yes Page 7 of 8

Supported Services, Continued Product Application Service Initiates Requests Executes Requests SRCM UTCTimesynchronization Service No Yes Who-Is Yes Yes Who-Has No Yes I-Am Yes Yes I-Have Yes No Page 8 of 8