User Manual for EMC Series Charger

Similar documents
User Manual for CH-PFC76810

BITMAIN. APW PSU Series User Guide

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Installation and Operation Guide for PD4000 Series Power Control Center

3000W Power Inverter

User s Manual Before using the inverter, you need to read and save the safety instructions.

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Solar Controller / Battery Charger User s Manual

Installation and Operation Guide for PD4100 Series Power Control Centers

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

13 Watt PORTABLE SOLAR POWER KIT

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

Integrating Sound Level Meter and Datalogger

Battery Power Inverters

1. SAFETY INFORMATION

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

SCHWINTEK IN-WALL SLIDEOUT TROUBLESHOOTING AND COMPONENT REPLACEMENT

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Charging what can be more simple? SAE J1772

MCR1900 Media Converter 19-Slot Chassis

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

BB800 Off-Grid Solar System

650W Single Output Power Supply

Installation/Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850

Drayton Digistat +2RF/+3RF

OWNER S MANUAL. Model AE150/AE300/AE AMP MULTI-USE SMART BATTERY CHARGER READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

MODEL 2202IQ (1991-MSRP $549.00)

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

NRG. Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

EC450 Power Control System

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Power your CPAP machine no matter where your world takes you!

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Model 70A00-1. GSM Cellular Communications Center

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

Emergency lighting units EM powerled

VLT Series 300 Watt True Sine Wave Inverter

How To Use A Power Supply Unit (Upu)

MP-4000 Alarm List (Software version or later)

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

AXIS T81B22 DC 30W Midspan

PSC POWER STAR LiFE TM

12 Volt 30 Amp Digital Solar Charge Controller

Handheld portable appliance testers

GV-Boost Manual. 8A Input / W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controllers with Maximum Power Point Tracking

User Manual 1K/2K/3K Online UPS

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

Home Solar Kit Owner s Manual. Model: HS

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Online UPS. PowerWalker VFI 1000R/1U

USER MANUAL Online UPS 6K/10K RACK

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Stroom voor elke toepassing

Powerware 5110 UPS User s manual

BTX180 Wireless Bluetooth Speaker

RADIANT PLASMA 4700 Plasma Spark Generator

User Guide. 4 wire Earth Resistance Tester Model GRT300

TROUBLESHOOTING GUIDE

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

SYSTEM DESCRIPTION Termination Boards

HYDRA HV OPERATION MANUAL. 2.0 Making Connections on your HYDRA speed control. Rosin core electrical solder

Modular I/O System Analog and Digital Interface Modules

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

DC POWER SUPPLY ALIMENTATION C.C.

Duct Humidity Transmitter

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Instruction book IQAN-MDM. Publ. no. HY /UK Edition June, 2007

MOUNTING AND OPERATING INSTRUCTIONS

TIG INVERTER INSTRUCTION MANUAL

AutoRanging Digital MultiMeter

is then retained absolutely without interruption.

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

BATTERY CHARGER OWNER S MANUAL

Bulletin 1609 Uninterruptible Power Supply

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Datasheet. Observe safety instructions on page 3 V2.1

ENGLISH USER MANUAL. Victron Atlas Combi 12/450. victron energie. user manual 5

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MGL Avionics CAN bus interface for Trig Avionics TT21/TT22 transponders

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

USER MANUAL GEBRUIKSAANWIJZING MODE D'EMPLOI BEDIENUNGSANLEITUNG

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

How To Power A Schen

A/C-HEATER SYSTEM - AUTOMATIC

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Table Of Contents

Mobile Data Power Model: MDP-25

Manual Ranging MultiMeter

Danfoss Link Mobile Phone Butler

Transcription:

User Manual for EMC Series Charger 1. Overview The EMC series chargers are suitable for charging lithium ion battery packs such as those used in electric vehicle applications. The EMC series chargers are designed to work seamlessly with Elite Power or digital input for safe battery charging. Standard safety features include protection against a short circuit on the charger output, reverse polarity, over charging, over temperature, etc.

2. Technical Parameters 2.1 Specifications Model: EMCXX- YY (XX: Output Voltage, YY: Output Amps) Efficiency: 88% Input voltage: 110V AC (220V AC available as special order) Input voltage range: AC 95 ~ 130V / AC 195 ~ 242V Frequency: 40 ~ 60Hz Communication: CAN and 12V Digital Input Vibration: SAEJ1378 Water resistance: IP31 Power factor: 0.75 2.1 Operating Environment Altitude: 2000 Meters Temperature: - 30 C ~ 55 C Installation Stress: level 5 Humidity: 5% ~ 70% RH Non Condensing, keep away from exposure to moisture Storage environment: - 30 C ~ 60 C Keep away from combustible materials

3. Charging Status and Alarm Status Indication 3.1 Alarm Indication Reverse polarity or low voltage: Charger over heating: Ambient temperature too high: Charging time out: Over Voltage Protection: BMS alarm/charging interruptions Red light blinking, 20% light on Red light blinking, 40% light on Red light blinking, 60% light on Red light blinking, 80% light on Red light blinking, 100% lights on 3.2 Charging Status Indication Shutdown status: Charging stage: - Battery presence not detected: Charging complete: Six lights blinking Percent light indicating pack voltage vs. max charging voltage Red light blinking, 20% light on All green lights on 4. Functions 4.1 Output short circuit protection. 4.2 Over- temperature protection: Temperature less than 83 C Full charging power Temperature is 85 C to 95 C Power reduced to 50% Temperature is greater than 95 C No output 4.3 Reverse polarity protection: charger will not turn on if the battery pack is connected backwards (or less than 5V). 4.4 A switch on the charger to select either external or internal controlled charging. Override Off Use with EMS system, either CAN or digital input Override On Charger program based on pack voltage only (recommended for testing purposes only, do not use for normal charging).

4.5 When external control is selected and a CAN signal is used, if any cell reaches the recharge set point (default 3.7V as signaled by the EMS) the charger will automatically enter the final recharge cycles. 4.6 Recharge cycles. When the EMS detects any cell has reached the recharge set point (default 3.7V) or above, the charger reduces the charge current to zero amps for five minutes to allow the EMS to balance the battery pack. The charge will resume after five minutes at half the previous charge current and will again charge until it receives a signal from the EMS that a cell has reached the recharge set point. These recharge cycles continue until the charging current reaches the minimum charging current to complete the charging process. 4.7 Digital alarm input: 0.0V 2.0V: Charging stopped 2.5V 12.0V: Enable charging or resume charging 4.8 When both CAN and the digital control signals are available the charger is controlled by the CAN communication signal. 5. Connections 5.1 IEC Connector For EMC chargers which output 10A or less the charger comes with an IEC type connector for the output. The connections to the battery pack are made as follows:

5.2 Anderson SB50 Connector EMC Chargers with output greater than 10A come with an Anderson SB50 style connector - the charger. - + 5.3 CAN and Digital Input Controls A five wire connector connects to the charger for interfacing with the BMS. Three wires have a white connector attached, these three wires are the CAN interface. The other two - - inal whenever a pack normal situation is detected. During charging if a cell exceeds the maximum voltage limit this will drop to 0 volts which will trigger the charger to temporarily pause charging until the high voltage cell can return to a normal voltage this occurs.

12V- For a CAN communication connection connect the CANH, CANL and CAN GND to the matching connection on the CAN connection on the EMS CPU. The white connector may be cut off of the cable; however, note which wires are which before doing so. CANH CANL CAN GND

If both the CAN communication and the digital inputs are connected CAN communications will take priority over the digital input for charge control. CAN communications requires the optional CAN board be installed on the EMS CPU.

Do not attempt connect the CAN communication connection to this port! 6. Cautions Make sure charger voltage output matches to the number of cells in the battery pack. Make sure positive output of the chargers is connected to a positive connection to the battery pack, and the negative output of the charger is connected to a negative connection of the battery pack. After a complete charge, disconnect the power source from the charger and then disconnect the connection between the charger and the battery pack. A BMS system must be used during the charging process either through CAN communication or through the digital alarm input to prevent over- charging. 7. Troubleshooting The charger must be installed in a cool well- ventilated area which is free of dust If the charger is not charging unplug the charger from the AC line and battery pack, then check for poor connections, short circuits, over heating conditions as well as alarm status from the Energy Management System.

be blow. Unplug the charger from the battery pack and AC line and check the fuse by unscrewing the cap with a #2 Philips screw driver. If the fuse is blown replace with an equivalent size fuse of the same voltage and amperage rating. If the charger finishes charging too early make sure that the connection from the charge to the battery pack is good and does not have high resistance.