Live Tank Circuit Breakers Routine testing

Similar documents
Power Capacitor Units for improved power quality

ABB s Disconnecting Circuit Breakers Higher substation availability and lower environmental impact

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

Houston Service Center Medium Voltage Service and Aftermarket Solutions

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Power transformers. Generator step-up and system intertie power transformers Securing high-quality AC transmission

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

Erik Backström, High Voltage breakers, After Sales & Service High voltage SF 6 live tank circuit breakers After Sales & Service Training course

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold C

VD4. Vacuum circuit-breaker

Power transformers. Special transformers Railway

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Product overview brochure. ABB Medium Voltage Products Our one-stop approach for every medium voltage application

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

Technical data. RCBO s DS 261 / DS 271 Residual current operated circuit breakers with integral overcurrent protection

General information Circuit breakers for power distribution T1 T3

The Intelligent AX1 Switchgear for Medium Voltage

After Sales Support SAFELINE. Metal Detection & X-Ray Inspection

Remote Monitoring and REC 501 Control Unit Product Guide

Circuit Breaker LTB D with Motor Drive. Motor Drive. ABB PP/H/HV - Page 1. Ed

Hydraulic Safety Program

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Safe and secure distribution of medium voltage with AX1

TYPE TEST CERTIFICATE OF SHORT-CIRCUIT PERFORMANCE. A three-phase outdoor oil-immersed distribution transformer

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Environmental Product Declaration. Registration number: S-P Rev. 0 11/06/03. Tmax T1. Low voltage circuit breaker.

Lockout / Tagout Program

GAS SAFETY PRECAUTIONS

Sample - No Commercial Use

Changing industry standards: friend or foe?

Medium Voltage Motor Control Assemblies

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Energy Design Resources Commissioning Plan Outline Template

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

OLI. Oil level indicator

Contents. Description. Product Selection Guide

Medium Voltage Distribution FLUVAC. Vacuum Circuit Breaker Up to 24 kv 630 A 21 ka. Operation Maintenance Instructions.

OVR-3SP Recloser with PCD Control Style Guide 1VAL SG March 30, 2009 Revision B

Analytical Products and Solutions. Complete service and maintenance solutions for your analytical equipment. usa.siemens.com/analyticalproducts

8146/5 Series Breaker Panelboards

Guide to the China Compulsory Certification System December 2009 OMRON Corporation Industrial Automation Company

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Virtual sales. assistant. Navigating within ABB to find complete Industrial IT solutions

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

Transformer oil cooler ALFA A02

Current and voltage measuring relays

PUBLICATIONS. Introduction

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

The easy way to build switchgear and controlgear assemblies in compliance with the regulations

A Comparison of Contemporary Electrical Distribution Equipment Standards. San Francisco IEEE Industry Applications Society May 26, 2009

CompactLogix Power Supplies Specifications

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

Diesel Engine Driven Generators Page 1 of 6

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

DF-DT (G) MEDIUM VOLTAGE SWITCHGEAR THE MODULAR CONCEPT. User Manual. SGC - SwitchGear Company nv - Moorstraat 24 - B-9850 Nevele - Belgium

Transformers Energy efficient transformer solutions European Minimum Energy Performance Standard (MEPS)

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

THE OKONITE COMPANY. Ramsey, New Jersey Fax:

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

Medium voltage product. Instrument transformers for indoor applications Product overview

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Dielectric Withstand Testing in a Production Environment

SC Series: MIS Chip Capacitors

Document Management Operations Audit Checklist

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL SG October 13, 2009 Revision F

NATIONAL TALLY CENTER (NTC) OPERATIONS PROCEDURES Presidential and Provincial Council Elections

MNS is Switchgear System Technical Overview

TABLE OF CONTENTS 1.0 INTRODUCTION PURPOSE DEVIATION INTERTIE PROTECTION REQUIREMENTS... 4

For more information please contact your local UL field representative

Electronic overload relay EF65, EF96 and EF146

innovation in wire wound magnetic solutions

DNVGL-CP-0393 Edition December 2015

AdvAntAge SerieS Switch-rAted iec Pin And Sleeve

Lockout/Tagout Training Program

How To Test A Power Distribution Unit

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Medium voltage indoor circuit breakers ANSI/IEC solutions

MV vacuum circuit breaker Evolis. When trust guides your steps

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

OJ L 191, , p. 26. OJ L 2, , p. 1.

ANSYS SCADE Model-Based Development Solutions for Industrial Equipment and Energy. Critical Systems & Software Development Solutions

Product brochure. GMS600 monitoring system for generator circuit-breaker State-of-the-art monitoring

Application Functional Safety IEC 61511

Procedure for Procurement and Receipt

Everything you need for protection scheme testing

Electronic overload relay EF19 and EF45

Modular Systems wind portfolio overview Power Collection and Grid Connection products

GAMP5 - a lifecycle management framework for customized bioprocess solutions

Auditing a Printed Circuit Board Fabrication Facility Greg Caswell

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

Transcription:

Live Tank Circuit Breakers Routine testing

Routine tests Live tank circuit breakers 2 ABB Live tank circuit breaker routine testing

All circuit breakers are tested ABB has a well established process to ensure on-time delivery of circuit breakers to its customers with the highest level of quality and reliability. At the live tank circuit breaker production facility in Ludvika, over 3000 circuit breakers are manufactured and routine tested annually. The routine tests are performed for the purpose of ensuring the quality and guaranteed performance of the material, design and assembly of the circuit breaker and are made on each apparatus manufactured. We welcome customer witnessing of these tests. The routine tests are part of the process of producing the circuit breakers and are always performed with the same test procedures, irrespective whether or not the tests are witnessed by the client s representative. Performance of routine tests The main steps of the order process related to routine testing are described in the example timeline shown below. The exact timing of these steps may vary depending on the size and complexity of the order. An invitation to witness routine testing is part of the order acknowledgement, when planned dates for routine testing and shipping are given. Confirmation is sent to the customer normally six weeks before the planned routine test dates. When the final dates have been advised, participation of any inspector(s) shall be confirmed by the customer at least three weeks before the planned dates for routine tests. Any requests for special or additional test procedures shall always be advised well in advance, preferably with order placement, but at the latest with the confirmation of witnessing participation. It must be noted that any requested changes to the test process or the planned date for routine testing will affect the deli very time. Week Activities 1 Order received from customer 2 Order acknowledgement sent by ABB with preliminary date for routine testing Order design work complete. Drawings sent for customer approval. After customer design approval, materials purchased for circuit breaker X-7 ABB confirms date for routine tests and requests confirmation of customer intention to witness testing X-4 Customer confirms intention to witness or not X-2 Circuit breaker assembly work X-1 Routine testing done X Circuit breaker packed and shipped ex-works Delivery time = "X" weeks, ex-works After each routine test, a test review meeting is held together with the client's witness in order to summarize the tests, documentations and for resolving any questions which may have arisen during tests. For each circuit breaker a complete routine test report, approved and certified by an ABB test supervisor, is issued and distributed to the customer as part of the order documentation. ABB Live tank circuit breaker routine testing 3

Production process Goods receiving Materials and components for circuit breaker assembly are inspected on arrival and before use for compliance to ABB requirements. Many items are also routine tested in advance by the suppliers in accordance with ABB instructions, the documentation for which can be shown on request. Breaker pole, Mechanical and Electrical assembling Tests are also conducted on major modules of the circuit breaker during the factory assembly process, prior to the final routine testing of the complete circuit breaker poles and operating mechanism(s). Routine test The final routine test process is described further on pages 6 and 7. Packing After completion of routine testing the circuit breaker is disassembled into its shipping modules for packing. Delivery to customer After packing the circuit breaker is shipped to the customer according to agreed order requirements. Any non-compliant components are clearly marked and isolated from production for further analysis. 4 ABB Live tank circuit breaker routine testing

Manufacturing Interrupters Breaker pole assembly Goods recieving Operating mechanism Mechanism assembly Routine test Packing Delivery to customer Operating mechanism Electrical assembly ABB Live tank circuit breaker routine testing 5

Routine test process Summary of routine tests IEC ANSI/IEEE ABB Nameplate and design check X X X Resistance measurement X X X (Components in auxiliary and control circuits) Function check of auxiliary and control circuits X X X Mechanical operating test X X X Resistance measurement (Main circuit) X X X Dielectric test (Auxiliary and control circuits) N/A X X Dielectric test (Main circuit) X X X Tightness test X X X Delivery time = "X" weeks, ex-works Meeting the standards Routine testing of ABB circuit breakers is a tightly controlled part of our quality production process. All testing follows the protocols strictly, and is highly automated to ensure accuracy of the applied test levels and result measurements, in accordance with international standards. The main routine test steps with respect to IEC, ANSI and ABB standards are summarized in the table on this page. A more detailed description of these steps can be provided on request. 6 ABB Live tank circuit breaker routine testing

Minutes Activities completed 0 Start of routine test 10 Nameplate and design check 40 Function check of auxiliary and control circuits 60 Operating mechanism adjustment tests 90 Mechanical operating test 100 Motor and closing spring charging tests 115 Resistance measurement (Main circuit) 125 Dielectric test (Auxiliary and control circuits) 155 Overpressure test, tightness test 175 Dielectric test (Main circuit) 180 Transfer to packing department The entire process is normally completed within approximately 3 hours per three pole operated breaker. The routine test report is automatically generated from the computerized test system and can be reviewed in full by the customer witness shortly after test completion. Workflow To ensure timely production flow and maintain on-time delivery commitments for all customers, the routine test process is planned to follow a strict time schedule. The timing of the routine test process for a three-pole operated breaker (or one phase of a single pole operated breaker) is summarized in the timeline on this page. The entire routine test for each circuit breaker is documented in a detailed routine test report, generated by the computerized testing system. After verification by the ABB certified test supervisor, this report is provided to the customer as part of the order documentation. ABB Live tank circuit breaker routine testing 7

Contact us ABB AB High Voltage Products SE-771 80 Ludvika, Sweden Phone: +46(0)240-78 20 00 Fax: +46(0)240-78 36 50 www.abb.com/highvoltage Copyright 2013 ABB All rights reserved NOTE! ABB AB is working continuously to improve the products. We therefore reserve the right to change designs, dimensions and data without prior notice. Publication Live tank circuit breaker routine testing 1HSM 9543 21-03en, Edition 3, 2013-10, High Voltage Products, Photo: Hasse Eriksson.