4" to 20" Sentry Series

Similar documents
Model DE-3 Air Release Head

MPU 800c. We put you first. And keep you ahead. MPU GAS ULTRASONIC FLOWMETER PRINCIPLE OF OPERATION FEATURES. Bulletin SSKS008 Issue/Rev. 0.

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

Daniel Liquid Turbine Flow Meters. Technical Guide April 2015

Analog signal converters CC-E I/I Current / current isolators

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

Turbine Flowmeters for Gas Applications

Air Eliminators and Combination Air Eliminators Strainers

Redundancy Module QUINT-DIODE/40

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

Fisher D3 Control Valve

SITRANS F flowmeters SITRANS F M

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

OPTIMASS 6000 Technical Datasheet

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

Scraper Passage Indicator. Electrical Indicator. Features

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Turbine Flow Sensor Series VTR

For Multi-Parameter Meters see mvx

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

T U R B I N E G A S M E T E R

Features. Picture. Specifications

Explosion proof enclosures

Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Transmitters and Alarms

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

IFC 070 Technical Datasheet

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

The Unique Accelabar Flow Meter

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

OPTIMASS 1400 Technical Datasheet

SIZING AND CAPACITIES OF GAS PIPING

The L&J Engineering Model MCG 1500SFI Servo Gauge

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Micro Motion 3098 Gas Specific Gravity Meter

Thermistor motor protection

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MG Transmitter with Digital Output.

Rack mounted telephone- and leased line modem for industrial applications

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

08.08 Vic-Check Valves

Measurement & Analytics. VIS Multiphase Flow Meter High gas content applications solved with no radioactive source - Measurement made easy

Telephone- and leased line modem for industrial applications TD-36

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

TEIP11 I/P signal converter for standard signals. Measurement made easy

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

3DLevelScanner II TECHNICAL DATA SHEET

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

In-Line Electronic Flow Switches

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Micro Motion 7829 Visconic Viscosity Meter

38 Series - Relay interface modules A

4 Posiflow Proportional Solenoid Valves

Microcor Wireless Transmitter (MWT)

Fluxi 2000/TZ Turbine Gas Meter

VAD. Variable Area Desuperheaters

1788 Linking Device Specifications

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

Three-phase monitoring relay CM-PFE

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

MINI MCR-SL-R-UI(-SP)

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics

1756 ControlLogix Chassis Specifications

8146/5 Series Breaker Panelboards

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

SITRANS F flowmeters. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/12 Siemens FI

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

Electromagnetic Flow Meter

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Micro Motion Model D and DL Coriolis Flow and Density Meters

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

LIQUID FLOW PROVERS (Conventional) Class Number 252. Brendan S. Ryan Smith Meter Inc P.O. Box 4658 Corpus Christi, Texas 78404

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

Inductive sensor NI10-M18-Y1X-H1141

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Smith Meter AccuLoad III

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Technical Information RIA14

How To Use A Flowmeter

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Terminal Boxes Series 8146

XFC 6201EX flow computer XSeries products

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

How To Use A Ds340 (Dsp)

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Waveguide Access Point WGA631. Product Guide

Gas Turbine Fuel Control Valve

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Foxboro Evo Process Automation System

Toroidal Conductivity Sensor

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

Transcription:

SPECIFICATIONS MEASUREMENT SOLUTIONS 4" to 20" Sentry Series Bulletin SS02001 Issue/Rev. 1.3 (8/15) We put you first. And keep you ahead. SMITH METER TURBINE METERS The Smith Meter Sentry Series Turbine Meter is a rimmed, rotor-type meter with helical blades. Sentry Series Turbine Meters utilize both an upstream and downstream stator and have tungsten carbide bearings with a hydro-dynamic thrust balance system. They provide highly accurate measurement required for custody transfer of petroleum liquids such as crude oil and refined products in larger pipelines. FEATURES Rimmed rotor for durability and high resolution pulse output Helical blades for a streamlined flow pattern less susceptible to cavitation All Stainless Steel wetted parts for corrosionfree service Tungsten carbide bearings provide long life on low lubricity liquids Hydrodynamic thrust balance system to minimize friction and wear on thrust bearings which allows for long service life and high accuracy NACE Compliance to MR0175/ISO 15156-1 Model Code K2DG OPERATING SPECIFICATIONS Linearity 4 ±0.15% linearity over normal flow range. ±0.10% linearity over 5:1 flow range. ±0.07% linearity over 5:1 flow range. Repeatability Per API MPMS or OIML R-117-1. OPTIONS Bidirectional flow allows the meter to accurately register flow in either direction. Multiple pickup coils are used when direction sensing or pulse security is required. A third pickup coil is available to drive auxiliary equipment, such as a back-up counter or prover. ±0.10% and ±0.07% linearity available. High-resolution (HR) output available on 4" through 8" meters to increase the pulse output per unit volume to allow proving with a smaller-size pipe prover 1. 1 Available with higher resolution (HR) pulse output than the nominal K-factor: size 4" - x1.5; sizes 6" LF, 6", and 8" - x2 2 Metric units are nominal and may not convert precisely. 3 For bidirectional flow, the minimum flow rate is 20% of the normal maximum rate. 4 Linearities and pressure drops based on 0.82 sp. gr., 1 mpa s (1.5 cp) liquid. Meter Sizes FLOW RANGE Normal Flow Range 3 Nominal K-Factor Units 1 1 Min. Max. Rate (Pulses/Unit) ±5% Rate 3 BPH 150 1,500 2,100 4" 2 m 3 /h 24 240 13,210 BPH 250 2,500 1,050 6" LF 2 m 3 /h 40 400 6,615 BPH 400 4,000 1,050 6" 2 m 3 /h 64 635 6,615 BPH 750 7,500 525 8" 2 m 3 /h 120 1,195 3,300 BPH 1,200 12,000 525 10" m 3 /h 191 1,910 3,300 BPH 1,800 18,000 265 12" m 3 /h 286 2,860 1,670 BPH 2,700 27,000 105 16" m 3 /h 430 4,295 662 BPH 3,500 35,000 105 18" m 3 /h 557 5,565 662 BPH 4,200 42,000 105 20" m 3 /h 668 6,680 662

Overspeed 130% of maximum flow rate for 5% duty cycle. End Connections Class 150, 300, 600, ASME B16.5, 125-250 AARH finish raised face (RF) flanges. Consult factory for higher working pressure or other types of flanges. MAXIMUM WORKING PRESSURE - PSI (kpa) ASME Carbon Steel Flanges Stainless Steel Flanges 150 285 (1,965) 275 (1,896) 300 740 (5,102) 720 (4,964) 600 1,480 (10,205) 1,440 (9,929) METER OPERATING TEMPERATURE RANGE Meter with: Pickup Coil Pickup Coil and Preamp Pickup Coil and Preamp with 24" Standoff Carbon Steel Flanges -20 F to 225 F -29 C to 107 C -20 F to 158 F -29 C to 70 C -20 F to 225 F -29 C to 107 C Consult factory for temperatures outside noted ranges. Stainless Steel Flange -50 F to 225 F -46 C to 107 C -50 F to 158 F -46 C to 70 C -50 F to 225 F -46 C to 107 C Electrical Approvals UL/CUL, Listed 557 N Class I Groups C and D; Class I, Zone 1, Group IIB; IP66; UNL-UL ENCL. 4, CNL-CSA ENCL. 4; Tamb -50 C to 70 C ATEX / IEC Ex PTB 08 ATEX 1034X, IEC Ex PTB 08.0040X (meter) Ex d IIC T3 - T6 Tamb = -40 C to 70 C IP66 PTB 10 ATEX 1039X, IEC Ex PTB 10.0052X (junction box) Ex d IIC T4 - T6 Gb Tamb = -40 C to 70 C IP66 Essential Health and Safety Requirements EN/IEC 60079-0: Electrical apparatus for potentially explosive atmospheres general requirements EN/IEC 60079-1: Electrical apparatus for potentially explosive atmospheres flameproof enclosures 'd' EN 60529: Degrees of protection provided by enclosures (IP code) EMC Compliance: (by Council Directive 2004/108/EC) Electromagnetic Emissions: EN 61000-6-3 Electromagnetic Immunity: EN 55022 IEC 61000-4-2: Electrostatic Discharge (ESD), Level 3+ (8.0 kv by contact, 12 kv by air) IEC 61000-4-3: Radiated Electromagnetic Field, Level 3 (10 V/m) IEC 61000-4-4: Electrical Fast Transient (Burst), Level 2 (1kV) IEC 61000-4-5: Electrical High Energy Pulses (Surge), Installation Class 3, Criterion B MATERIALS OF CONSTRUCTION Flanges (Not Wetted) Body 316 Series Stainless Steel Carbon Steel Optional: 304 Series Stainless Steel Internals 300 Series Stainless Steel, Except 430 Stainless Steel Rotor Buttons Bearings and Tungsten Carbide Thrust Washers INSTALLATION The meter must be mounted in a horizontal attitude (±5 ) within a suitable flow conditioning assembly and is recommended that the meter be installed downstream of a strainer for protection and upstream of the system control valve. Refer to the installation manual MN02003 for full instructions. APPLICATIONS High Viscosity The flow range of turbine meters is reduced considerably when metering viscous liquids. The minimum flow rate must be increased as the viscosity increases. The following relationships can be used to approximate the increase (reduction in range) that will maintain the stated linearity. Viscous Min. = Normal Min. x Viscosity (cp) Rate Rate Meter Size (in) Note: Caution should be used when dealing with liquids that result in a viscous minimum rate greater than two times the normal, since variations in operating temperature can result in substantial meter factor shifts. Low Density When metering light hydrocarbons such as LPG or other liquids with specific gravity less than 0.8, the minimum flow rate should be shifted upward. The amount of shift can be approximated by multiplying the normal minimum flow rate by the following factor: Rate Increasing Factor = 0.9 S Where: S = The specific gravity of the liquid being metered. The increased flow rate should not exceed the meter's overspeed flow rate. 2 Bulletin SS02001 Issue/Rev. 1.3 (8/15)

Minimum Back Pressure In order to prevent cavitation, API M.P.M.S. Chapter 5 recommends a minimum back pressure according to the following: PICKUP COIL SPECIFICATIONS Type: Variable reluctance. L e R e BP = (2 x P) + 1.25 Vp Where: BP = Minimum back pressure P = Pressure drop at maximum flow rate VP = Absolute vapor pressure at operating temperature Example: 6" Sentry at 4,000 BPH P = 6 psi. Absolute vapor pressure of butane at operating temperature - Vp = 50 psia. Min. BP = (2 x 6) + 1.25 (50) = 74.5 psi V o Electrical Characteristics Effective Series Resistance (R e): 1,020 Ω (±20%) Effective Series Inductance (L e): 450 mh @ 1,000 Hz Minimum Open Circuit Voltage (V o): 300 millivolts p/p at minimum flow rate Maximum Transmission Distance: 2,000 ft (610 m) using #20 AWG two-conductor, shielded cable Notes: A preamplifier is recommended for remote instrumentation that does not have Common Mode Noise Rejection. See Bulletin SS02012 for PA-6 Preamplifier Specifications. Pressure Drop 4 Flow - Cubic Meters per Hour 20 50 100 500 1,000 5,000 10,000 9.0 10 8.0 Data based on 0.8 sp. gr., 7.0 2.0 mpa s (2.0 cp) viscosity. 6.0 5.0 4.0 3.0 2.0 4 in 6 LF in 6 in 8 in 10 in 12 in 16 in 18 in 20 in 60 50 40 30 25 20 15 P 10 P PSI 9.0 kpa 1.0 8.0 0.9 7.0 0.8 6.0 0.7 5.0 0.6 4.0 0.5 0.4 0.3 3.0 2.5 2.0 0.2 1.5 1.0 0.9 0.8 0.1 100 500 1,000 5,000 10,000 50,000 100,000 Flow - Barrels per Hour 4 Linearities and pressure drops based on 0.82 sp. gr., 1 mpa s (1.5 cp) liquid. Bulletin SS02001 Issue/Rev. 1.3 (8/15) 3

CATALOG CODE The following guide defines the correct Sentry turbine meter for a given application and the respective catalog code. This code is part of the ordering information and should be included on the purchase order. 1 2 3 4 5 6 7 8 9 10 11 K 2 D F A 0 A 1 0 0 0 Position 1: Code K - Catalog Code Position 2: Product Line 2 - Turbine Meter Position 3: Model D - Sentry Series ASME End Connections Position 4: Size and Type R - 4-Inch V - 4-Inch High Resolution F - 6-Inch Low Flow W - 6-Inch Low Flow, High Resolution G - 6-Inch S - 6-Inch High Resolution H - 8-Inch T - 8-Inch High Resolution J - 10-inch K - 12-Inch L - 16-Inch M - 18-Inch N - 20-Inch Position 5: Pressure Class ASME End Connections (ASME B16.5) A - Class 150 B - Class 300 D - Class 600 Position 6: End Connections 5 0 - Carbon Steel RF Flanges F - 304 Stainless Steel RF Flanges Position 7: Internal Configuration A - Unidirectional Flow, 430 Stainless Steel Buttons B - Bidirectional Flow, 430 Stainless Steel Buttons Position 8: Pickup Coils and Preamplifiers Meter Mounted Junction Box(es) with 0-1 Pickup Coil 1-1 Pickup Coil and Preamplifier 2-2 Pickup Coils 3-2 Pickup Coils and 2 Preamplifiers 4-2 Pickup Coils and 1 Preamplifier 7-3 Pickup Coils and 2 Preamplifiers P - 3 Pickup Coils and 3 Preamplifiers Pickup Coil(s) with Explosion Proof Totalizer/Flow Rate Indicator 8 - MMRT with PA-11 and 1 Pickup Coil 9 - MMRT with PA-11 and 2 Pickup Coils Pickup Coil(s) with Online Diagnostics S - 1 Pickup Coil and AccuLERT 6 XU T - 2 Pickup Coils and AccuLERT 6 XU Extended Temperature Range with Preamplifier on 24-Inch Standoff D - 1 Pickup Coil and 1 Preamplifier J - 2 Pickup Coils and 2 Preamplifiers Extended Temperature Range with Online Diagnostics on 24-Inch Standoff E - 1 Pickup Coil and AccuLERT 6 XU K - 2 Pickup Coils and AccuLERT 6 XU Extended Temperature Range with Explosion Proof Totalizer/Flow Rate Indicator on 24-Inch Standoff F - MMRT with PA-11 and 1 Pickup Coil L - MMRT with PA-11 and 2 Pickup Coils Miscellaneous M - INVALCO 202D Totalizer with Pickup Coil N - INVALCO 202D Totalizer with Pickup Coil on 24-Inch Standoff X - Special Position 9: Testing / Linearity Linearity 0 ±0.15% 1 ±0.10% (5:1 flow turndown) 2 ±0.07% (5:1 flow turndown) 3 Special testing Position 10: Compliance with Standards 0 - UL/CUL Listed 3 - ATEX / IEC Ex Certified 4 - ATEX / IEC Ex / PED 7 Certified 5 - UL / CUL / CRN Position 11: Specials 0 - None X - Special - Specify 5 Low temperature (below -20 F) requires stainless steel end connections. 6 The AccuLERT also provides dual channel preamplification and online diagnostics. 7 PED required for all European countries; equipment must be manufactured by Ellerbek, Germany facility. 4 Bulletin SS02001 Issue/Rev. 1.3 (8/15)

DIMENSIONS WEIGHT Inches (mm) and Pounds (kg) A A 2 3" Explosion-Proof Box (76) 2" (51) 1" NPT B C Second pickup coil spaced 90 electrical degrees, +/- 60 degrees from first coil (optional) Dimensions inches to the nearest tenth (millimeters to the nearest whole mm), each independently dimensioned from respective engineering drawings. Class 150 ASME Class 300 ASME Class 600 ASME Size A B 8 C Wt. C Wt. C Wt. 4" 6"LF 6" 8" 10" 12" 16" 18" 20" 12.0 (305) 16.0 (406) 24.0 (610) 30.0 (762) 40.0 (1,016) 45.0 (1,143) 50.0 (1,270) 5.8 (149) 6.9 (175) 6.9 (175) 7.9 (201) 9.0 (228) 10.0 (253) 11.6 (294) 12.6 (320) 13.6 (345) 9.0 (228) 11.0 (279) 11.0 (279) 13.5 (343) 16.0 (406) 19.0 (483) 23.5 (597) 25.0 (635) 27.5 (699) 65 (30) 135 (61) 100 (45) 155 (70) 265 (120) 385 (175) 835 (379) 1,060 (481) 1,510 (686) 10.0 (254) 12.5 (318) 12.5 (318) 15.0 (381) 17.5 (445) 20.5 (521) 25.5 (648) 28.0 (711) 85 (38) 185 (84) 145 (66) 230 (104) 350 (159) 575 (261) 1,080 (490) 1,405 (638) 10.8 (273) 16.5 (419) 20.0 (508) 22.0 (559) 110 (50) 295 (134) 245 (111) 320 (114) 560 (294) 750 (340) CF CF CF Note: Meter weights by flange class with one pickup coil and explosion-proof box. Add 5 lb (2.3 kg) for each additional pickup coil and explosion-proof box. 8 Add 24" for a standoff when using a preamplifier for temperatures 158 F to 225 F (70 C to 107 C). Bulletin SS02001 Issue/Rev. 1.3 (8/15) 5

We put you first. And keep you ahead. Revisions included in SS02001 Issue/Rev. 1.3 (8/15): ANSI changed to ASME throughout. Electrical Approvals: ATEX/IEC Ex updated. The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are currently in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect. Contact information is subject to change. For the most current contact information, visit our website at www.fmctechnologies.com/measurementsolutions and click on the Contact Us link in the left-hand column. www.fmctechnologies.com/measurementsolutions 2015 FMC Technologies. All rights reserved. SS02001 Issue/Rev. 1.3 (8/15) FMC Technologies Measurement Solutions, Inc. 500 North Sam Houston Parkway West, Suite 100 Houston, Texas 77067 USA P:+1 281.260.2190 USA Operation 1602 Wagner Avenue Erie, Pennsylvania 16510 USA P:+1 814.898.5000 Germany Operation Smith Meter GmbH Regentstrasse 1 25474 Ellerbek, Germany P:+49 4101.304.0 6