IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation 1

Similar documents
When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

UniStream CPU-for-Panel

OPLC Installation Guide

Screen 3.5" Color Touch 4.3" Color Touch Keypad or Function Keys Programming Com Port, Built-in

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Advantium 2 Plus Alarm

INSTALLATION INSTRUCTIONS

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Modular I/O System Analog and Digital Interface Modules

Sunny Boy Accessories SMA POWER BALANCER

Model: DC-A2IO Advanced HVAC Controller

CompactLogix Power Supplies Specifications

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

12 Volt 30 Amp Digital Solar Charge Controller

Duct Humidity Transmitter

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

C13 User Manual Document ID: 2CMC486004M0201 Revision: A

3M Wrist Strap and Footwear Tester 740. User s Guide

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

BroadBand PowerShield. User Manual

Manual. Solar Fountain Mobile Phone Charger

CQM1-SF200/CS1W-SF200

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

About the BitStorm 6051 POTS Splitter

Model 201 Wiegand Touchpad Reader Installation Guide

Vision OPLC. V R34/V350-J-R34 Technical Specifications. Technical Specifications

User Guide. HDMI Active Cable Extender. DVI-7370c

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

DMX2PWM 9 Channel Dimmer Setup Manual

Single Station Remote Alarm

StorTrends 3400 Hardware Guide for Onsite Support

MCR1900 Media Converter 19-Slot Chassis

Electronic Control Devices The European Product Catalogue 2007

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Universal Serial Bus (USB) to DH-485 Interface Converter

StructureScan HD Module. Installation Guide ENGLISH

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

AXIS T81B22 DC 30W Midspan

Original instructions Tina 3A/Aps Adaptor unit

About this Manual. Support for Your Product

Digital input modules

How To Install A Power Supply (Uplast) With A Battery Pack

Users manual. TCW181B-CM_R1 Page 1

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Tina 2A/B Adaptor unit

Installation. Smart-UPS VT and MGE Galaxy Maintenance Bypass Panel with Power Distribution (wall-mount) kva 208 V

YSmart Technology Co.,Ltd

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Adjustment functions for both span and shift have been incorporated

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

12-Volt 10-Amp Regulated Power Supply

ADM1TE 5/30A DIN rail single phase two wire energy meter

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

MLC TM Maximum Productivity and Versatility for Control without Compromise!

User s Guide OSXL-100-PE. Thermal Imaging Camera Enclosure. Shop online at omega.com SM

Square D Clipsal Two-Channel DIN-Rail DALI Gateway

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Manual. Simrad StructureScan LSS-1 Sonar Module. English

AC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134

Copyrights 2010 Victron Energy B.V. All Rights Reserved

Wall-Mounting your HP computer. User Guide

Square D Clipsal C-Bus Network Analyzer

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

16/32 Channel 1U Rack Mount CCTV Power Supply

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

=============================== WARNING

Y7230A CO 2 Alarm System

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

User's Guide. Integrating Sound Level Datalogger. Model Introduction

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Installation guide H A. HSI hardwired system interface

Part I - Installation

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

QNAP RAID Expansion Enclosure Hardware User Manual QNAP Systems, Inc. All Rights Reserved.

HMI display Installation Guide

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

EXTERNAL DIMENSIONS AND PARTS

IO-DIM6 6-Channel, Digital to Analogue Converters

Wireless Indoor/ Outdoor Thermometer

INSTALLER S & OWNER S MANUAL

PT Mbps Powerline Adapter. User Guide

RAY-MAX Integrated Solar Power Strip

Old Company Name in Catalogs and Other Documents

PSACH v.1.0 PSACH 24VAC/6A/1x6A HERMETIC AC power supply for CCTV

DLP-PU/E Instruction Manual

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

L5354 ControlNet Communications Interface

Water Leak Detection System

SP-1700 OWNERS MANUAL

Transcription:

IO-PT4 I/O Expansion Module 4 PT100 Inputs (-50 to 460 C) The IO-PT4 is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 4 PT100 inputs for temperature measurement. The interface between the module and the OPLC is provided by an adapter. The module may either be snap-mounted on a DIN rail, or screw-mounted onto a mounting plate. 1 4 IO-PT4 PT PT0 PT1 OUT OF RANGE 5 Component identification 2 1 Module-to-module connector 2 Status indicators 3 Input connection points, PT2 & PT3 4 Module-to-module connector port 5 Input connection points, PT0 & PT1 PT2 PT3 3 Before using this product, it is the responsibility of the user to read and understand this document and any accompanying documentation. All examples and diagrams shown herein are intended to aid understanding, and do not guarantee operation. Unitronics accepts no responsibility for actual use of this product based on these examples. Please dispose of this product in accordance with local and national standards and regulations. Only qualified service personnel should open this device or carry out repairs. User safety and equipment protection guidelines This document is intended to aid trained and competent personnel in the installation of this equipment as defined by the European directives for machinery, low voltage, and EMC. Only a technician or engineer trained in the local and national electrical standards should perform tasks associated with the device s electrical wiring. Symbol Meaning Description Symbols are used to highlight information relating to the user s personal safety and equipment Danger protection throughout this document. When these symbols appear, the Warning associated information must be read carefully and understood fully. Caution Caution Use caution. The identified danger causes physical and property damage. The identified danger can cause physical and property damage. Failure to comply with appropriate safety guidelines can result in severe personal injury or property damage. Always exercise proper caution when working with electrical equipment. Unitronics Industrial Automation 1

IO-PT4 I/O Expansion Module 7/03 Check the user program before running it. Do not attempt to use this device with parameters that exceed permissible levels. Install an external circuit breaker and take appropriate safety measures against short-circuiting in external wiring. To avoid damaging the system, do not connect / disconnect the device when the power is on. Environmental Considerations Do not install in areas with: excessive or conductive dust, corrosive or flammable gas, moisture or rain, excessive heat, regular impact shocks or excessive vibration. Mounting the Module Leave a minimum of 10mm space for ventilation between the top and bottom edges of the device and the enclosure walls. Do not place in water or let water leak onto the unit. Do not allow debris to fall inside the unit during installation. DIN-rail mounting Snap the device onto the DIN rail as shown below; the module will be squarely situated on the DIN rail. 3.5mm (0.137") 44.5mm (1.75") 93mm (3.66") 14mm (0.55") 60mm (2.362") 80mm (3.15") Screw-Mounting The figure on the next page is drawn to scale. It may be used as a guide for screw-mounting the module. Mounting screw type: either M3 or NC6-32. 2 Unitronics Industrial Automation

7/03 IO-PT4 I/O Expansion Module 5.8mm (0.228") 4mm (0.16") 80mm (3.15") 68.4mm (2.693") 93mm (3.66") 85mm (3.346") 4mm (x2) (0.16") Unitronics Industrial Automation 3

IO-PT4 I/O Expansion Module 7/03 Connecting Expansion Modules An adapter provides the interface between the OPLC and an expansion module. To connect the I/O module to the adapter or to another module: 1. Push the module-to-module connector into the port located on the right side of the device. Note that there is a protective cap provided with the adapter. This cap covers the port of the final I/O module in the system. To avoid damaging the system, do not connect or disconnect the device when the power is on. Component identification 1 Module-to-module connector 2 Protective cap 1 2 Wiring Do not touch live wires. Unused pins should not be connected. Ignoring this directive may damage the device. Double-check all wiring before turning on the power supply. The power supply of both adapter and outputs' must be connected to the same 0V signal. Wiring Procedures Use crimp terminals for wiring; use 26-12 AWG wire (0.13 mm 2 3.31 mm 2 ) for all wiring purposes. 1. Strip the wire to a length of 7±0.5mm (0.250 0.300 inches). 2. Unscrew the terminal to its widest position before inserting a wire. 3. Insert the wire completely into the terminal to ensure that a proper connection can be made. 4. Tighten enough to keep the wire from pulling free. To avoid damaging the wire, do not exceed a maximum torque of 0.5 N m (5 kgf m). Do not use tin, solder, or any other substance on stripped wire that might cause the wire strand to break. Install at maximum distance from high-voltage cables and power equipment. I/O Wiring General Input or output cables should not be run through the same multi-core cable or share the same wire. 4 Unitronics Industrial Automation

7/03 IO-PT4 I/O Expansion Module Analog Inputs Shields should be connected at the signal source. 2 wire connection PT100 3 wire connection PT100 PT0 PT1 IO-PT4 PT OUT OF RANGE PT2 PT3 PT100 4 wire connection Unitronics Industrial Automation 5

IO-PT4 I/O Expansion Module 7/03 IO-PT4 Technical Specifications Max. current consumption Typical power consumption Status indicator (RUN) 35mA maximum from the adapter s 5VDC 0.09W @ 5VDC Green LED: Lit when a communication link is established between module and OPLC. Blinks when the communication link fails. Analog Inputs Number of inputs 4 Input type PT100 Input range -50 to 460 C Isolation None Resolution 12-bit (4096 units) Measurement resolution ±0.1 C. See Note 1. Conversion method Successive approximation Conversion time 40msec Input impedance 10MΩ minimum Auxiliary current for PT100 1.9mA Linearity error ±0.25 C (±0.05%) Temperature accuracy ±0.4 C Status indicators (OUT OF RANGE) Red LEDs Lit when the corresponding input measures an analog value (temperature) outside of the permissible range. See Note 2. Connection options 2,3 or 4 wires Environmental IP20 / NEMA1 Operating temperature 0 to 50 C (32 to 122 F) Storage temperature -20 to 60 C (-4 to 140 F) Relative Humidity (RH) 5% to 95% (non-condensing) Dimensions (WxHxD) 80 x 93 x 60mm (3.15 x 3.66 x 2.362 ) Weight 140.3g (4.94oz.) Mounting Either onto a 35mm DIN-rail or screw-mounted. Notes: 1. The input analog value represents the temperature value as follows: Analog value-262 Actual measured temperature: 26.2 C 2. The temperature values can also indicate certain faults as shown in the table below. Value Possible Cause -1000 * Input temperature is out of the permissible range (under -50 C) * -I signal is not connected * Sensor is short-circuited 1000 * Input temperature is out of the permissible range (over 460 C) * Sensor is not connected to input * +I or +V signals are not connected * -I and V signals are not connected 6 Unitronics Industrial Automation

7/03 IO-PT4 I/O Expansion Module Addressing I/Os on Expansion Modules Inputs and outputs located on I/O expansion modules that are connected to an OPLC are assigned addresses that comprise a letter and a number. The letter indicates whether the I/O is an input (I) or an output (O). The number indicates the I/O s location in the system. This number relates to both the position of the expansion module in the system, and to the position of the I/O on that module. Expansion modules are numbered from 0-7 as shown in the figure below. Adapter 0 1 2 3 4 5 6 7 Expansion module identification number The formula below is used to assign addresses for I/O modules used in conjunction with the OPLC. X is the number representing a specific module s location (0-7). Y is the number of the input or output on that specific module (0-15). The number that represents the I/O s location is equal to: 32 + x 16 + y Examples Input #3, located on expansion module #2 in the system, will be addressed as I 67, 67 = 32 + 2 16 + 3 Output #4, located on expansion module #3 in the system, will be addressed as O 84, 84 = 32 + 3 16 + 4. EX90-DI8-RO8 is a stand-alone I/O module. Even if it is the only module in the configuration, the EX90-DI8- RO8 is always assigned the number 7. Its I/Os are addressed accordingly. Example Input #5, located on an EX90-DI8-RO8 connected to an OPLC will be addressed as I 149, 149 = 32 + 7 16 + 5 Unitronics Industrial Automation 7

IO-PT4 I/O Expansion Module 7/03 About Unitronics Unitronics Industrial Automation Systems has been producing PLCs, automation software and accessory devices since 1989. Unitronics OPLC controllers combine full-function PLCs and HMI operating panels into single, compact units. These HMI + PLC devices are programmed in a single, user-friendly environment. Our clients save I/O points, wiring, space, and programming time; elements that translate directly into cost-efficiency. Unitronics supports a global network of distributors and sales representatives, as well as a U.S. subsidiary. For more information regarding Unitronics products, contact your distributor, Unitronics headquarters via email: export@unitronics.com, or visit the Unitronics website at http://www.unitronics.com/. Under no circumstances will Unitronics be liable or responsible for any consequential damage that may arise as a result of installation or use of this equipment, and is not responsible for problems resulting from improper or irresponsible use of this device. No part of this document may be used for any purpose other than for the purposes specifically indicated herein nor may it be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and/or recording, for any purpose without written permission from Unitronics. The information appearing in this document is for general purposes only. Unitronics makes no warranty of any kind with regard to the information appearing in this document, including, but not limited to, 0implied warranties of merchantability and/or fitness for a particular use or purpose. Unitronics assumes no responsibility for the results, direct and/or indirect, of any misuse of the information appearing in this document nor for any use of the Unitronics products referred to herein in any manner deviating from the recommendations made in this document. Unitronics assumes no responsibility for the use of any parts, components, or other ancillary appliances including circuitry other than as recommended hereunder or other than that embodied in the Unitronics product. Unitronics retains all rights to its proprietary assets including, but not limited to its software products which are copyrighted and shall remain the property of Unitronics. Copyright protection claimed includes all Forms and matters of copyrightable materials and information legally allowed including but not limited to material generated from the software programs which are displayed on the screen of the Unitronics products such as styles, templates, icons, screen displays, looks, etc. Duplication and/or any unauthorized use thereof are strictly prohibited without prior written permission from Unitronics. All brand or product names are used for identification purpose only and may be trademarks or registered trademarks of their respective holders. Unitronics reserves the right to revise this publication from time to time and to amend its contents and related hardware and software at any time. Technical updates (if any) may be included in subsequent editions (if any). Unitronics product sold hereunder can be used with certain products of other manufacturers at the user s sole responsibility. 5408-0071-5 8 Unitronics Industrial Automation