Solid-state Relay. (Applicable output load) 5 a o 0 C (19 to 264 VAC)



Similar documents
Solid State Relays for Heaters

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

How To Read A Pipe From A Sensor

General-purpose Relay

SPST-NO SPDT DPST-NO DPDT

SPST-NO SPDT DPST-NO DPDT

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Model Number Structure

Model Number Structure

Solid-State Timer H3G

Surface Mounting Relay

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

NX safety stand-alone

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

650W Single Output Power Supply

Ordering Information. Latching Relay G2AK. Model Number Legend Magnetic Latching Version of G2A Ideal for Sequence Control

38 Series - Relay interface modules A

Solid State Relays with Built-in Current Transformer

Cross-beam scanning system to detect slim objects. 100 mm in

Liquid Leakage Sensor Amplifier

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

Solid-State Relays. Series Included. Solid-State Relays SIR SLR NLF PHS Series PHS...148

Adjustment functions for both span and shift have been incorporated

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information

Solid-State Relays 700-SA -SC, -SE, -SF, -SH, -SK. Application Guide

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

Capacitive Prox E2K-X

CQM1-SF200/CS1W-SF200

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Count input Display Time range h or 3999d23.9h (selectable) 999h59m59s or 9999h59.9m (selectable) 3. Case Color B: Black

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

RY2 miniature industrial relays

Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Relés e Contatores de Estado Sólido SIRIUS

38 Series - Relay interface modules A

DLP-PU/E Instruction Manual

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

MAXIMUM LOAD CURRENT 1 A SN SERIES

Smart DeviceNet Remote I/O Terminals

48 SERIES Relay interface modules 10 A

3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long

Absolute Rotary Encoder E6CP

49 Series - Relay interface modules A. Features

PCB Relay. LED indicator G2R-1A3-SN G2R-13-SN contact) LED indicator and diode DC G2R-1A3-SND G2R-13-SND

Single Output Switching Power Supply

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Multifunction Digital Timer

RM4TG20 three-phase network control relay RM4-T - range V

Type Contact material Contact form Construction Model General purpose AgCdO SPDT Semi-sealed G2R-1

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Incremental Rotary Encoder E6B2

Number of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

Type Terminal Coil Contact form Model

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Ordering Information. Application Example. New General-purpose Incremental. Rotary Encoder. Accessories (Order Separately)

KIA7805AF/API~KIA7824AF/API SEMICONDUCTOR TECHNICAL DATA THREE TERMINAL POSITIVE VOLTAGE REGULATORS 5V, 6V, 7V, 8V, 9V, 10V, 12V, 15V, 18V, 20V, 24V.

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Pluggable interface relays CR-P Pcb relays

Relays & Sockets. RH Series Compact Power Relays. Part Number Selection

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

unit : mm With heat sink (see Pd Ta characteristics)

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

E2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Solid State Relays Common Precautions

1a/1c 5A/10A small power relays

RC NETWORKS SALES GUIDE

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

7.5 Watt AC-DC Switch Power Supply

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity

S112-XHS. Description. Features. Agency Approvals. Applications. Absolute Maximum Ratings. Schematic Diagram. Ordering Information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Brushless DC Motors Intro duction BLF BLU BLH Installation. Brushless DC Motors. DC Input. AC Input DC Input. BLH Series. Page. BLH Series B-52 B-51

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

HL Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Model Number Structure.

SZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Transcription:

Solid-state Relay A Wide Range of s with 5- to 0-A Output Currents and Up to 80-VAC/00-VDC Output Voltages All models feature the same compact dimensions to provide a uniform mounting pitch. Built-in varistor effectively absorb external surges. Operation indicator (red LED) enables monitoring operation. Protective cover for greater safety. Standard models approved by UL/CSA and -UTU models by VDE (TÜV). Ordering Information Isolation Zero cross function Indicator Rated output load (Applicable output load) 5 a o 0 C (19 to VAC) Phototriac Yes Yes 5 A at to 0 VAC* Photocoupler Phototriac Photocoupler ocou 10 A at to 0 VAC* (19 to VAC) 10 A at 00 to 80 VAC* (180 to 58 VAC) Rated input voltage 5 to VDC -05B 100 to 10 VAC 00 to 0 VAC 5 to VDC -10B 100 to 10 VAC 00 to 0 VAC 5 to VDC -10B 100 to 0 VAC --- 10 A at 5 to 00 VDC* 5 to VDC -D10B ( to 0 VDC) 100 to 0 VAC Phototriac Yes 0 A at to 0 VAC* 5 to VDC -0B Photocoupler ocou (19 to VAC) 100 to 10 VAC 00 to 0 VAC 0 A at 00 to 80 VAC* 5 to VDC -0B (180 to 58 VAC) 100 to 0 VAC Phototriac 0 A at to 0 VAC* 5 to VDC -0B Photocoupler ocou (19 to VAC) 100 to 10 VAC 00 to 0 VAC 0 A at 00 to 80 VAC* 5 to VDC -0B (180 to 58 VAC) 100 to 0 VAC 50 A at 00 to 80 VAC* (180 to 58 VAC) 5 to VDC -50B *Loss time increases under 75 VAC. (Refer to page 18.) Note: When ordering a TÜV-approved model, add -UTU to the model number as shown below: Example: -10B-UTU 1

Accessories (Order Separately) Heat Sink The following heat sinks are thin and can be DIN-track mounted (except Y9B-P50). See Dimensions for details. Y9B-N50 Y9B-N100 Y9B-N150 Y9B-P50 Applicable SSR -05B, -10B, -D10B, -10B, G3NE-05T(L), G3NE-10T(L) -0B, -0B, G3NE-0T(L) -0B, -0B -50B Low-cost s Applicable SSR Y9B-A100-05B, -10B, -D10B, -0B, -10B, -0B Y9B-A150N -0B, -0B Y9B-A50-0B Mounting Bracket Used to mount the with a mounting dimension of 5 mm. Applicable SSR R99-11 -0B, -0B See Dimensions for details. (Refer to page 18.) Specifications Ratings (Ambient Temperature: 5 C) Rated voltage Operating voltage Impedance Voltage level Must operate voltage Must release voltage - B 5 to VDC to 3 VDC 7 ma max.* VDC max. 1 VDC min. 100 to 10 VAC 75 to 13 VAC 3 kω±0% 75 VAC max.** 0 VAC min.** 00 to 0 VAC 150 to VAC 7 kω±0% 150 VAC max.** 0 VAC min.** - B 5 to VDC to 3 VDC 5 ma max.* VDC max. 1 VDC min. -D10B 100 to 0 VAC 75 to VAC 7 kω±0% 75 VAC max. 0 VAC min. Note: The input impedance is measured at the maximum value of the rated supply voltage (for example, with the model rated at 100 to 10 VAC, the input impedance is measured at 10 VAC). *With constant current input circuit system. The impedance for the - B-UTU is 15 ma max. **Refer to the Engineering Data for further details. Output Applicable load Rated load voltage voltage range current Inrush current With heat sink* -05B to 0 VAC 19 to VAC 0.1 to 5 A 0.1 to 3 A 0 A (0 Hz, 1 cycle) -10B 0.1 to 10 A 0.1 to A 150 A (0 Hz, 1 cycle) -10B 00 to 80 VAC 180 to 58 VAC 0. to 10 A 0. to A -0B to 0 VAC 19 to VAC 0.1 to 0 A 0.1 to A 0 A (0 Hz, 1 cycle) -0B 00 to 80 VAC 180 to 58 VAC 0. to 0 A 0. to A -0B to 0 VAC 19 to VAC 0.1 to 0 A 0.1 to A 0 A (0 Hz, 1 cycle) -0B 00 to 80 VAC 180 to 58 VAC 0. to 0 A 0. to A -50B 00 to 80 VAC 180 to 58 VAC 0. to 50 A 0. to A -D10B 5 to 00 VDC to 0 VDC 0.1 to 10 A 0.1 to A 0 A (10 ms) *When OMRON s heat sink (refer to the accessories) or a heat sink of specified size is used.

Characteristics Operate time Release time Item -05B, -10B, -0B -0B 1/ of load power source cycle + 1 ms max. (DC input) 3/ of load power source cycle + 1 ms max. (AC input) 1/ of load power source cycle + 1 ms max. (DC input) 3/ of load power source cycle + 1 ms max. (AC input) -10B, -0B, -0B, -50B -D10B 1 ms max. (DC input) 30 ms max. (AC input) 5 ms max. (DC input) 30 ms max. (AC input) Output ON voltage drop 1. V (RMS) max. 1.8 V (RMS) max. 1.5 V max. Leakage current 5 ma max. (at 100 VAC) 10 ma max. (at 00 VAC) 5 ma max. (at 00 VDC) 10 ma max. (at 00 VAC) 0 ma max. (at 00 VAC) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength,500 VAC, 50/0 Hz for 1 min Vibration resistance Malfunction: 10 to 55 Hz, 1.5-mm double amplitude Shock resistance Malfunction: 1,000 m/s Ambient temperature Operating: 30 C to 80 C (with no icing or condensation) Storage: 30 C to 100 C (with no icing or condensation) Approved standards UL508 File No.E5/CSA C. (No.0, No.1) File No.LR35535 TÜV R91510 (EN0950) Ambient humidity Operating: 5% to 85% Weight Approx. 0 g Approx. 70 g Approx. 80 g Approx. 70 g 3

Engineering Data Current vs. Ambient Temperature Characteristics -05B -10B/10B -0B/0B 0 1 current (A) With standard heat sink (Y9B-A100 or Y9B- N50) or aluminum plate measuring 75 mm x 75 mm x 13. mm (W x H x D) current (A) 10 8 5 With standard heat sink (Y9B-A100 or Y9B-N50) or aluminum plate measuring 150 mm x 150 mm x 13. mm (W x H x D) current (A) With standard heat sink (Y9B-A100 or Y9B-N100) or aluminum plate measuring 00 mm x 00 mm x 13. mm (W x H x D) 0 current (A) -0B -0B -D10B 50 0 5 0 10 With standard heat sink (Y9B-A150N or Y9B-N150) current (A) 30 0 1 10 0 With standard heat sink (Y9B-A150N or Y9B-N150) With Y9B- A50 or heat sink with a radiation efficiency of 1 C/W. current (A) 5 0 With standard heat sink (Y9B-A100 or Y9B-N50) or aluminum plate measuring 150 mm x 150 mm x 13. mm (W x H x D) -50B With standard heat sink (Y9B-P50) current (A)

Inrush Current Resistivity Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) -05B -10B/10B -0B/0B -0B/0B/50B -D10B Temperature Characteristics (with Must Operate Voltage and Must Release Voltage) - B AC Variation rate (%) Heat Sink Size vs. Current -0B Heat sink size (cm ) Ambient temperature 80 C Ambient temperature 0 C Note: The heat sink size refers to the combined area of the sides of the heat sink that radiate heat. For example, when a current of 18 A is allowed to flow through the SSR at 0 C, the graph shows that the heat sink size is about 50 cm. Therefore, if the heat sink is square, one side of the heat sink must be 15 cm (15 x = 50) or longer. Aluminum plate 3. mm thick current (A) 5

Dimensions Note: All units are in millimeters unless otherwise indicated. In the case of surface mounting, a 30% derating of the load current is required. The orientation indicated by the external dimensions is not the correct mounting orientation. When opening mounting holes, refer to the mounting hole dimensions. -05B, -10B, -0B, -10B, -0B 58 max. 7.5.5 dia. Four, M x 8 screws 7.±0. Two,.3-dia. or M holes Terminal Arrangement/ Internal Connections (Top View) 1 power supply.5 5 3 max. Operating indicator 13.8 5 max. 7 max. (-) (+) 3-0B, -0B, -50B 58 min.7.5.5 dia. Two, M5 x 1 screws.5 5 3 max. Operating indicator Two, M x 8 13.8 5 max. 7 max. 7.±0. Two,.3-dia. or M holes Terminal Arrangement/ Internal Connections (Top View) 1 (-) (+) 3 power supply -D10B 58 max. 7.5.5 dia..5 5 3 max. Four, M x 8 screws Operating indicator 13.8 5 max. 7 max. 7.±0. Two,.3-dia. or M holes Terminal Arrangement/ Internal Connections (Top View) 1 - + (-) (+) 3 power supply Heat Sink Y9B-N50. dia. Two, M3 holes Two, M holes Two, 3.-dia. holes 35±0. 35 30.5±0.3 max. 30 7. 77 max. 90±0.3 5. 7 max. 5.5 51 max. 90±0. Two,.-dia. or M holes Weight: approx. 00 g

Y9B-N100. dia. Two, M3 holes Two, M holes Two, 3.-dia. holes 35±0. 35 30.5±0.3 71 max. 30 75 max. Two,.-dia. or M holes 7. 77 max. 90±0.3 5. 8 5 13.5 90±0. Weight: approx. 00 g Y9B-N150. dia. 7. Three, M holes Two, 3.-dia. holes 35±0. 35 30 10 max. 90±0. Two,.-dia. or M holes 5±0.3 5. 8 5 13.5 77 max. 90±0.3 Weight: approx. 50 g Y9B-A100 Y9B-A150N Three, M holes Y9B-A50 Three, M holes 90 ± 0.1 Two, M holes 90 ± 0.1 R. 7. 90 ± 0.1 R. 7. 100.5 max. 1.5 80.5 max. 9. 7. 50±0.1 50±0.1 5±0.5 150 max. 50±0.1 5±0.5 50 max. 30 5.5 max. 1.5 Y9B-A100 Y9B-A150 Y9B-A50 Four,.3-dia. or M holes Four, M Four,.5 dia. or M 190.5 max. 90±0.1 50±0.1 Four, R.5 130.5 max. 70 max. 7

R99-11 1 8 1 1.5 5. 5 Use Mounting Bracket R99-11 so that the -0B can be mounted with the same pitch as that of the G3N-0B. Precautions Refer to pages 11 to 19 for general precautions. Connection For an AC load, use a power supply rated at 50 or 0 Hz. The maximum operating frequency is 10 Hz. The has a built-in varistor for overvoltage protection. Zero Cross Function An SSR with a zero cross function operates when an AC load voltage reaches the zero point or its vicinity. This reduces clicking noises when the load is input, and minimizes the influence of an inductive load, such as a lamp, heater, or motor, on the power supply because the inrush current of the load is reduced. This can also minimize the scale of the inrush current protection circuit. When attaching a heat sink to the, apply Silicone Grease or equivalent heat conductive grease on the heat sink. (Toshiba Silicon, Shinetsu Silicon, etc.) Tighten the mounting screws of the heat sink with a torque of 0.78 to 0.98 N m. EN55011 Measurement of Mains Terminal Disturbance Voltage The -UTU conforms to EN55011 standards when a capacitor is connected to the load power supply as shown in the following circuit diagram. -UTU Output Output (load voltage) ON OFF At a low applied voltage, such as VAC, the load current is not fully supplied. When the Unit is switched ON, the voltage required to power the Unit deprives the output signal of the necessary voltage level and thus creates loss time. The lower the load voltage is, the greater the loss time is. This condition, however, will not create any serious problems. Recommended Capacitor: Nissei Denki s MKT-series R0 (1 µf) The output terminal side of the -D10B is connected to a builtin diode for protecting the SSR from damage that may result from reverse connection. The SSR, however, cannot withstand one minute or more if the wires are connected in reverse order. Therefore, pay the utmost attention not to make polarity mistakes on the load side. Loss time For a DC or L load, a diode should be connected in parallel the load to absorb the counter electromotive force of the load. SSR power supply ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.0357. Cat. No. K07-E1-1C 8