Torrent ECO. The final piece in your heating and hot water system. Open vented thermal store providing heating and mains pressure hot water

Similar documents
StainlessLite. Unvented mains pressure and vented water storage in Duplex stainless steel SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

Torrent ECO. Design, Installation & Servicing Instructions. Open vented thermal store providing heating and mains pressure hot water

Link-Up. Solid Fuel Association Guide to Central Heating.

Electric Flow Boiler

UNDERSTANDING CENTRAL HEATING SYSTEMS

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

Session 2: Hot Water Supply

UNDERSTANDING HOT WATER SYSTEMS IN THE HOME

High Output Boiler Systems

BoilerMate SP. benchmark. user instructions A - C L A S S

Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump

Natural geothermal energy.

Hot water supply, distribution and use

Vaillant s plain English guide to. simple, concise and precise

Stove-boiler for solid fuels KW Directions for use and assembling

ErP made easy What does it mean to merchants? What does it mean to installers?

Report Date: 04/03/2014. Assessor: John Doyle Address: BLOCK K APT 108 SANDYFORD VIEW DUBLIN 18 BER: MPRN:

Gas Condensing Boilers

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

Continuous flow direct water heating for potable hot water

GUIDE TO AIR SOURCE HEAT PUMPS. Consumer, Specifier, Installer and Merchant guide to Air to water heat pump technology

HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS

your water pressure explained

Qualification Guide. BPEC 601/2514/7 - Level 1 Diploma in Plumbing Foundation. BPEC 600/9432/1 - Level 2 Diploma in Plumbing Foundation

Solar Hot Water Heaters

Rainwater Harvesting

NIBE INSTALLER GUIDE TO ErP, SIMPLE AS 1 2 3

STOVE-BOILER FOR SOLID FUELS Directions for use and assembling

SOLAR HEATING SYSTEMS.

ROTEX gas hybrid heat pump. A strong team.

Fall in love with your heating again. Reduce your heating bills with

maximise the sun s energy with warmflow solar Warmflow Solar

Solar Hot Water. What systems are available?

Thermo Siphon Solar Systems

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions

Photo Kirklees IS SOLAR ENERGY FOR ME? A guide to going solar

Fully Pumped Systems

Daikin Altherma Hybrid Heat Pump

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

CE29. Domestic heating by oil: boiler systems guidance for installers and specifiers

User's Instructions. Alpha HE CB25/33 and HE SY25

CE30. Domestic heating by gas: boiler systems guidance for installers and specifiers

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

Get more from your hot water

Air Source Heat Pump Installation and Maintenance Manual

Daikin Altherma Hybrid Heat Pump

Ecodan Air Source Heat Pump and Flow Temperature Controller 2

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Baxi Combi 80e & 105e

Water Volume Calculation in Hydronic Heating & Cooling Systems

REGISTRATION EXAMINATION, JUNE 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

SF15K SF05KSS, SF10KSS

Non Domestic BER Assessors Technical Bulletin

The complete heating system.

Making heating systems efficient and cost-effective: boilers, heating controls & more

HUB RADIATOR HYBRID. Multi-energy hybrid system to produce heating and DHW. Multi-energy hybrid system to produce heating, cooling and DHW

A Class Air Source Heat Pump User Guide

building engineering services association specification for: Domestic Heating

SAP 2012 IN A NUTSHELL

ECOCIAT. Domestic hot water heat recovery unit

Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters

INTEC Engineering GmbH Heating Solutions for the Marine Industry

High Efficiency Boiler Range Technical Guide

Description of functions

HEAVY DUTY STORAGE GAS

Laddomat Charging unit

Home Made Solar Panel Installation For Under 900.

Why worry about your hot water system?

Technical data. Danfoss DHP-A

Response: The combi boiler. Response: The fit anywhere combi

High-efficient gas boiler CompactGas

ROTEX Solaris: Use the energy of the sun. ROTEX Solaris Solar energy for hot water and heating. The heating!

Metering and Monitoring Service Packages Technical Supplement

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Price List Rev.2. AGUIDROVERT S.L. c/ Cervantes 20, Zaragoza (Spain) Tel.: Fax:

Housing Solutions Limited. Terms and Conditions. Fixmy Boiler Service

main heating: pre1998 ducted warm air system main heating fuel: mains gas main heating SAP efficiency: 70.0% main heating controls: programmer

ErP made easy! Valves, controls + systems. Guideline Individual packages according to ErP with high energy efficiency and a good benefit/cost ratio

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

Morco House Riverview Road Beverley HU17 0LD. Retrofit or Upgrade a Water Heater in a Caravan Holiday home

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

EcoDesign & Labelling Directive (ErP)

Delivering exceptional performance and Ecovalue. Ecocent

service breakdown emergency 3in1 Plan What the SGS Service Plan provides What happens if you have a breakdown Cover provided by the Plan Dear

Solar Collector Series. Product List

Solar SOLARMAX ELECTRIC BOOSTED SPECIFICATIONS ALL AUSSIE GAS & ELECTRIC BOOSTED SOLAR WATER HEATERS

The energy you need. Clearly Hybrid. hybrid. Efficient Solutions. Heating. Hot Water.

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

FREQUENTLY ASKED QUESTIONS (SOLAR WATER HEATER)

Daikin Altherma Hybrid Heat Pump

Create the right atmosphere with renewables.

WC flushing cistern single or dual flush to fill in 2 minutes WC trough cistern 0.15 per WC Wash basin tap size 1 2

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

6 YEAR * PAYBACK A GUIDE TO DOMESTIC RENEWABLE HEAT INCENTIVE (RHI) SOLAR THERMAL SOLUTIONS

INSTANTANEOUS GAS FIRED

GREEN EFFICIENT FRIENDLY SUSTAINABLE ENERGY: CERTIFICATED TRAINING

Transcription:

Torrent ECO Open vented thermal store providing heating and mains pressure hot water SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS The final piece in your heating and hot water system

What is a thermal store? A thermal store provides the perfect solution to a homes heating and hot water requirements. Torrent ECO offers more options than any other store or cylinder, and is designed to reduce heating costs by offering complete flexibility for householders to use multiple energy sources. The benefits of thermal stores Provides mains pressure hot water Benefit for both heating and hot water No annual maintenance or safety check requirement No discharge pipework No risk of legionella Inherently safe being an open vented cylinder No G3 qualification requirement for installation The Torrent ECO enables the hot water within the store to circulate around the heating system to provide heat to the property, with the domestic hot water being mains cold water instantaneously heated through a plate heat exchanger. W www.gledhill.net 2

The flexible alternative The Torrent ECO is manufactured from copper, by our trained coppersmiths, within Gledhill s nine nationwide manufacturing depots. This provides the flexibility to specifically design the thermal store to suit their own requirements, allowing the homeowner to maximise the available heat sources, whether they are traditional boilers or electric immersions, or the growing popularity of alternative energy fuel sources. The cylinder is open vented, enabling uncontrolled heat sources such as woodburning stoves to be used. Energy source compatibility Gas /Oil Boiler Solid Fuel Boiler Heat Pump Solar Thermal Open vented or sealed primary boilers Electricity from either mains or solar PV Wood burning or solid fuel boilers Air source or ground source heat pumps Solar thermal 3 E sales@gledhill.net

What s new in With the new Energy-related Products (ErP) Directive for hot water cylinders in mind, the new Torrent ECO range has not only improved the benefits of the Torrent, but also added some fantastic new features to provide the home owner a immensely energy efficient thermal store. Torrent ECO features Energy saving with a high efficiency ErP ready pump Flow sensor providing a 75% reduction of hot water response times Improved PCB and software Higher store temperatures can be utilised, providing greater benefit from solid fuel inputs Secondary return functionality (optional kit available if required) A B C D E F For further information SCAN HERE G W www.gledhill.net 4

Product Selection The selection chart below is a guide to identify the correct Torrent ECO model required for your installation. To use this selection guide, identify the required heat sources for your cylinder in each section, follow the lines with the red line indicating no and the green line indicating yes. The option to add solid fuel tappings to utilise wood burning stoves or biomass boilers is available on the full range of Torrent ECO products. Electric Heat Source Gas/Oil Boiler Solar Thermal Heat Pump Torrent ECO HP Torrent ECO OV SOL Torrent ECO HP SOL Torrent ECO SP (Sealed Primary Boiler) Torrent ECO OV (Open Vented Boiler) Torrent ECO HP Torrent ECO OV SOL (Optional SP coil) Torrent ECO HP SOL Torrent ECO OV Torrent ECO HP Torrent ECO OV SOL Torrent ECO HP SOL Torrent ECO SP (Sealed Primary Boiler) Torrent ECO OV (Open Vented Boiler) Torrent ECO HP Torrent ECO OV SOL (Optional SP coil) Torrent ECO HP SOL Underfloor tappings optional through the full range. All models come complete with back up immersion. Where a Torrent ECO SP is used, heating should be provided directly by the boiler as store will only provide auxiliary heating. 5 E sales@gledhill.net

Torrent ECO OV Open Vent Store Overheat Domestic Hot Water Store Sensor Plate Heat Exchanger Flow Solid Fuel Flow (Optional) Boiler Flow OV Hot Supply Central Heating Flow Cold Mains Control Thermostat Central Heating Return Open Vented Boiler Return Cold Feed Solid Fuel Return (Optional) Plate Heat Exchanger Return Drain Features and benefits Utilises open vented boiler to heat the store directly 3kW immersion heater for emergency back-up Electric only versions available Optional solid fuel connections Provides mains pressure hot water Tappings shown above can be removed or optional extras added at the time of order Designed for use with Gas /Oil Boiler Solid Fuel Boiler Need more technical information? SCAN HERE W www.gledhill.net 6

Torrent ECO OV showing how the cylinder can utilise numerous heat sources (including optional extras) at the same time Multi-fuel stove Open vented boiler Torrent ECO OV Technical Specifications Mains pressure hot water Technical Notes: Please note the diagrams shown include optional extra components. Additional height for feed and expansion tank will need to be allowed if it is to be sited in the same cupboard. Vent pipes shown through the side of the feed and expansion tank may not be suitable for all systems. Installers must check suitability. The standard open vented store relies on a feed and expansion tank suitably sited above the highest radiator point to provide sufficient head for the system. The feed and expansion tank must be sized to take the water expansion of the whole system (ie. solid fuel boiler, cylinder, open flue boiler and auxiliary heating). The feed and expansion tank is not supplied as standard with the unit, but is available as an optional extra at the time of order. For solid fuel applications, copper feed and expansion tanks are available as an optional extra at the time of order. Cold mains water Central heating supplied from store Underfloor heating supplied from store Description TEC140-OV TEC170-OV TEC210-OV TEC250-OV TEC350-OV Energy efficiency class C C C D D Heat loss watts 66 74 84 93 114 Domestic hot water volume litres 140 170 210 250 350 Unit height mm 1219 1449 1414 1654 1874 Unit diameter mm 535 535 585 585 636 Max. hot water flow rate litres/minute 35 35 35 35 35 Maximum dwelling type Bath 1 1 2 2 3 Shower room - 1 1 2 2 Bed 1-2 2-4 3-4 3-5 3-5 7 E sales@gledhill.net

Torrent ECO SP Open Vent Store Overheat Domestic Hot Water Store Sensor Plate Heat Exchanger Flow Solid Fuel Flow (Optional) Central Heating Flow (Optional) Hot Supply Cold Mains Control Thermostat Sealed Primary Boiler Flow Sealed Primary Boiler Return Central Heating Return (Optional) Cold Feed Solid Fuel Return (Optional) Plate Heat Exchanger Return Drain Features and benefits Utilises a sealed primary boiler to heat the store indirectly via an internal coil Auxilliary or underfloor heating available directly from the store (subject to heat input) 3kW immersion heater for emergency back-up Optional solid fuel connections Provides mains pressure hot water Tappings shown above can be removed or optional extras added at the time of order Designed for use with Gas /Oil Boiler Solid Fuel Boiler Need more technical information? SCAN HERE W www.gledhill.net 8

Torrent ECO SP showing how the cylinder can utilise numerous heat sources (including optional extras) at the same time Multi-fuel stove Technical Description TEC140-SP TEC170-SP TEC210-SP TEC250-SP TEC350-SP Energy efficiency class C C C D D Heat loss watts 66 74 84 93 114 Domestic hot water volume litres 140 170 210 250 350 Unit height mm 1219 1449 1414 1654 1874 Unit diameter mm 535 535 585 585 636 Max. hot water flow rate litres/minute 35 35 35 35 35 Maximum dwelling type Sealed boiler Sealed system kit Torrent ECO SP Technical Specifications Mains pressure hot water Auxiliary central heating supplied from store limited to heat input provided by auxiliary heat source Underfloor heating supplied from store Central heating supplied by boiler Bath 1 1 2 2 3 Shower room - 1 1 2 2 Bed 1-2 2-4 3-4 3-5 3-5 Notes: Please note the diagrams shown include optional extra components. Additional height for a feed and expansion tank will need to be allowed if it is to be sited in the same cupboard. Vent pipes shown through the side of the feed and expansion tank may not be suitable for all systems. Installers must check suitability. The feed and expansion tank must be sized to take the water expansion of the whole system (ie. solid fuel boiler, cylinder, open flue boiler and auxiliary heating). The feed and expansion tank is not supplied as standard with the unit, but is available as an optional extra at the time of order. For solid fuel applications, copper feed and expansion tanks are available as an optional extra at the time of order. Cold mains water 9 E sales@gledhill.net

Torrent ECO SOL Open Vent Store Overheat Domestic Hot Water Store Sensor Plate Heat Exchanger Flow Open Vented Boiler Flow Central Heating Flow Sealed Primary Boiler Flow (Optional) Sealed Primary Boiler Return (Optional) Central Heating Return Solar Sensor Solid Fuel Flow (Optional) Control Thermostat Hot Supply Cold Mains Open Vented Boiler Return Solid Fuel Return (Optional) Solar Coil Flow Solar Sensor Solar Coil Return Cold Feed Solid Fuel Return (Optional) Plate Heat Exchanger Return Drain Features and benefits Specifically designed for use with solar thermal panels Utilises open vented boiler to heat the store directly Optional sealed primary boiler connections 3kW immersion heater for emergency back-up Optional solid fuel connections Provides mains pressure hot water Tappings shown above can be removed or optional extras added at the time of order Designed for use with Gas /Oil Boiler Solid Fuel Boiler Solar Thermal Need more technical information? SCAN HERE W www.gledhill.net 10

Torrent ECO Solar showing how the cylinder can utilise numerous heat sources (including optional extras) at the same time Multi-fuel stove Torrent ECO SOL Technical Specifications Technical Description TEC210-SOL TEC250-SOL TEC350-SOL TEC450-SOL Energy efficiency class C D D D Heat loss watts 84 93 114 134 Domestic hot water volume litres 210 250 350 450 Unit height mm 1414 1654 1874 1764 Unit diameter mm 585 585 636 738 Dedicated solar volume 2 litres 62 73 101 130 Max. solar collector area 1 m 2 2.47 2.91 4.03 5.19 Solar heat exch. surface area 1 m 2 0.27 0.34 0.40 0.54 Max. hot water flow rate litres/minute 35 35 35 35 Maximum dwelling type Either an open vented, sealed primary or a combination of the two boilers can be used Open vented boiler Sealed boiler Sealed system kit Sensor circuit Solar controller Bath 1 1 2 3 Shower room 1 2 2 2 Notes: 1 To comply with the Building Regulations ADL1 Domestic Heating Compliance Guide. 2 This can be adjusted at the time of specification. Solar pumping station Mains pressure hot water Cold mains water Expansion vessel Pressure relief If using an SP boiler, the auxiliary central heating supplied from the store is limited to the heat input provided by the auxiliary heat source Underfloor heating supplied from store Central heating supplied by boiler Bed 2-4 2-4 3-5 4-6 Please note the diagrams shown include optional extra components. Additional height for feed and expansion tank will need to be allowed if it is to be sited in the same cupboard. Vent pipes shown through the side of the feed and expansion tank may not be suitable for all systems. Installers must check suitability. The standard open vented store relies on an feed and expansion (feed & expansion) tank suitably sited above the highest radiator point to provide sufficient head for the system. As the domestic hot water is at mains pressure, the Torrent ECO Solar itself can be sited anywhere in the property. Provision is also made within the design for a sealed heating/boiler circuit with the heat exchanger provided which would then operate as a conventional cylinder. Although this would reduce the potential for utilising the solar energy in the HEATING CIRCUIT, it would mean that both the Torrent and the feed and expansion tank can then be sited anywhere in the property, as the feed and expansion is only being used to fill the store with water. The feed and expansion tank must be sized to take the water expansion of the whole system (ie. solid fuel boiler, cylinder, open flue boiler and auxiliary heating). The feed and expansion tank is not supplied as standard with the unit, but is available as an optional extra at the time of order. For solid fuel applications, copper feed and expansion tanks are available as an optional extra at the time of order. 11 E sales@gledhill.net

Torrent ECO HP Open Vent Store Overheat Domestic Hot Water Store Sensor Plate Heat Exchanger Flow Solid Fuel Flow (Optional) Hot Supply Heat Pump Cylinder Sensor Control Thermostat Heat Pump Flow Central Heating Flow Central Heating Immersion Central Heating Return Heat Pump Return Sensor Heat Pump Return Cold Mains Domestic Hot Water Heat Pump Flow Sensor Cold Feed Solid Fuel Return (Optional) Plate Heat Exchanger Return Drain Features and benefits Specifically designed for use with either air source or ground source heat pumps Heating provided directly from the store Optional solid fuel connections 3kW immersion heaters for boost and emergency back-up for both heating and hot water Provides mains pressure hot water Tappings shown above can be removed or optional extras added at the time of order Designed for use with Solid Fuel Boiler Heat Pump Need more technical information? SCAN HERE W www.gledhill.net 12

Torrent ECO HP showing how the cylinder can utilise numerous heat sources (including optional extras) at the same time Multi-fuel stove Heat pump Torrent ECO HP Technical Specifications Technical Mains pressure hot water Cold mains water Central heating Description TEC170-HP TEC210-HP TEC250-HP TEC350-HP TEC450-HP Energy efficiency class C C D D D Heat loss watts 74 84 93 114 134 Domestic hot water volume litres 170 210 250 350 450 Unit height mm 1449 1414 1654 1874 1764 Unit diameter mm 535 585 585 636 738 Max. hot water flow rate litres/minute 15 15 15 15 15 Maximum dwelling type Bath 1 1 2 2 3 Shower room 1 2 1 2 2 Bed 2-3 2-3 3-4 3-4 4-5 Notes: Please note the diagrams shown include optional extra components. The suggested model sizes in the selection chart are based on a store temperature of 75 C. If the intention is that the heat pump will be used to provide the majority of the hot water with minimum boost from another heat source then consideration should be given to choosing a larger model of Torrent ECO HP appliance. See the Design Installation and Servicing Instructions for equivalent volumes at different charge temperatures. If the immersion heater is to be used as the hot water boost a suitable control system should be installed to ensure that the heat pump has fully charged the appliance before the boost immersion heater is allowed to operate. This will ensure the most efficient and cost effective use of the system. Additional height for feed and expansion tank will need to be allowed if it is to be sited in the same cupboard. The feed and expansion tank must be sized to take the water expansion of the whole system (ie. solid fuel boiler, cylinder, open flue boiler and auxiliary heating). The feed and expansion tank is not supplied as standard with the unit, but is available as an optional extra at the time of order. For solid fuel applications, copper feed and expansion tanks are available as an optional extra at the time of order. 13 E sales@gledhill.net

Torrent ECO HP SOL Open Vent Store Overheat Domestic Hot Water Store Sensor Plate Heat Exchanger Flow Solar Sensor Solid Fuel Flow (Optional) Heat Pump Cylinder Sensor Control Thermostat Heat Pump Flow Central Heating Flow Central Heating Return Heat Pump Return Sensor Heat Pump Return Solar Coil Flow Solar Coil Return Hot Supply Domestic Hot Water Heat Pump Flow Sensor Cold Mains Central Heating Solid Fuel Return (Optional) Solar Sensor Cold Feed Solid Fuel Return (Optional) Plate Heat Exchanger Return Drain Features and benefits Specifically designed to combine solar thermal and heat pump technology Heating provided directly from the store Optional solid fuel connections to provide the ultimate alternative energy cylinder 3kW immersion heaters for boost and emergency back-up for both heating and hot water Provides mains pressure hot water Tappings shown above can be removed or optional extras added at the time of order Designed for use with Solid Fuel Boiler Heat Pump Solar Thermal Need more technical information? SCAN HERE W www.gledhill.net 14

Torrent ECO HP SOL showing how the cylinder can utilise numerous heat sources (including optional extras) at the same time Multi-fuel stove Heat pump Torrent ECO HP SOL Technical Specifications Technical Sensor circuit Solar controller Mains pressure hot water Cold mains water Solar pumping station Expansion vessel Central heating Description TEC210-HPSOL TEC250-HPSOL TEC350-HPSOL TEC450-HPSOL Energy efficiency class C D D D Heat loss watts 84 93 114 134 Domestic hot water volume litres 210 250 350 450 Unit height mm 1414 1654 1874 1764 Unit diameter mm 585 585 636 738 Dedicated solar volume 2 litres 62 73 101 130 Max. solar collector area 1 m 2 2.47 2.91 4.03 5.19 Solar heat exch. surface area 1 m 2 0.27 0.34 0.40 0.54 Max. hot water flow rate litres/minute 15 15 15 15 Maximum dwelling type Bath 1 1 2 2 Shower room 1 2 1 2 Notes: 1 To comply with the Building Regulations ADL1 Domestic Heating Compliance Guide 2 This can be adjusted at the time of specification. Bed 2-3 2-3 3-4 3-4 Please note the diagrams shown include optional extra components. The suggested model sizes in the selection chart are based on a store temperature of 75 C. If the intention is that the heat pump will be used to provide the majority of the hot water with minimum boost from another heat source then consideration should be given to choosing a larger model of Torrent ECO HP SOL appliance. See table 1b in the Design Installation and Servicing Instructions for equivalent volumes at different charge temperatures. If the immersion heater is to be used as the hot water boost a suitable control system should be installed to ensure that the heat pump has fully charged the appliance before the boost immersion heater is allowed to operate. This will ensure the most efficient and cost effective use of the system. Additional height for feed and expansion tank will need to be allowed if it is to be sited in the same cupboard. The feed and expansion tank must be sized to take the water expansion of the whole system (ie. solid fuel boiler, cylinder, open flue boiler and auxiliary heating). The feed and expansion tank is not supplied as standard with the unit, but is available as an optional extra at the time of order. For solid fuel applications, copper feed and expansion tanks are available as an optional extra at the time of order. Pressure relief 15 E sales@gledhill.net

UK Super Depot Infrastructure Blackpool Head Office and Stainless Steel Manufacturing Site Nottingham Telephone: 01773 580684 Fax: 01773 581129 Blackburn Telephone: 01254 693844 Fax: 01254 673615 Bristol Telephone: 01179 820814 Fax: 01179 820821 Inverkeithing Telephone: 01383 414133 Fax: 01383 413123 Luton Telephone: 01582 728253 Fax: 01582 318976 Maidstone Telephone: 01622 714770 Fax: 01622 882286 Oldbury Telephone: 01384 636245 Fax: 01384 413700 Paignton Telephone: 01803 557470 Fax: 01803 559213 Southampton Telephone: 01329 846601 Fax: 01329 845881 For technical advice please call 01253 474584 SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS Gledhill Building Products Limited Sycamore Estate, Squires Gate, Blackpool FY4 3RL Tel: 01253 474550 Fax: 01253 474551 sales@gledhill.net Gledhill Building Products produce cylinders for use with a wide range of heat sources including; Gas and oil boilers Electricity Air source heat pumps Ground source heat pumps Solar energy Wood burning stoves Further information on Gledhill products can be found on the internet at www.gledhill.net To protect our environment, we use copper a totally recyclable metal, which Only the best never becomes waste. is acceptable FM 02057 Due to a programme of continuous improvement Gledhill Building Products reserve the right to modify products without prior notice. It is advisable to check the product technical detail by using the latest design and installation manuals available from our technical support team or on our website. It is an offence to copy or adapt this document without consent of the owner. Spec 173/02 09/15