Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup.

Similar documents
Easy evaluation of displays using high-resolution data!! 2D Color Analyzer

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

Data Management Software CA-S20w Ver.2.4 Instruction Manual

Data Management Software CA-S25w

Overview. Raster Graphics and Color. Overview. Display Hardware. Liquid Crystal Display (LCD) Cathode Ray Tube (CRT)

1. SAFETY INFORMATION

Video surveillance camera Installation Guide

QuickSpecs. Model. HP USB HD 720p v2 Business Webcam. Overview

CS Digital Microscope User Manual

Standard Cables (Without electromagnetic brake, with electromagnetic brake) CC010ES-2. 1 m CC020ES-2. 2 m CC030ES-2. 3 m CC050ES-2.

Precision Lightmeters Made in Germany

DSM155 Digital LED Light Meter User s Manual DSM155

Data Management Software CL-S10w Ver.1.3. Instruction Manual

PT-LB55NT S P E C F I L E. Micro-Portable Wireless LCD Projector. As of February Specifications subject to change without notice.

Sympodium Interactive Pen Display

Better Vision with LED lights

SPECTROPHOTOMETER CM-2600d. Simply expands the Boundaries in Color Control

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

ZEISS Axiocam 506 color Your Microscope Camera for Imaging of Large Sample Areas Fast, in True Color, and High Resolution

Color Data Software CM-S100w. Professional Edition Lite Edition 10

User's Guide. Integrating Sound Level Datalogger. Model Introduction

The Foundation User Manual LED Battery Slim Par Fixture (RGBA, DMX 7Ch/4CH)

High Resolution Media Display - B series 20mm Pitch Outdoor RGB Module

Outline. Quantizing Intensities. Achromatic Light. Optical Illusion. Quantizing Intensities. CS 430/585 Computer Graphics I

Basler. Line Scan Cameras

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

SNC-VL10P Video Network Camera

VPL-DX15 VPL-DX11 VPL-DX10. Powerful Tabletop Projectors

Network Camera SNC-P1

EF-S18-55mm f/ IS II COPY ENG. Instruction

22" Widescreen LED Monitor VA2261-2

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

FB-500A User s Manual

Rodenstock Photo Optics

Data Management Software. CL-S10w. Installation Guide

Basic Specifications. Electrical. EPSON Perfection Color EPSON MatrixCCD TM line sensor. device Effective pixels

22 (21.5 viewable), 16:9 FHD LED monitor with SuperClear VA technology and HDMI input. VA2265Sh

FPD IN-LINE SPECTRAL TESTING SOLUTIONS

SMART Podium Interactive Pen Display

SURFACE MOUNT LED LAMP STANDARD BRIGHT 0606

Session 15 Lighting Fundamentals

LCD Drawer User Manual

LUT Luminescence scanners: Seeing what no-one else can

CNC-STEP. "LaserProbe4500" 3D laser scanning system Instruction manual

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

D/N VARI-FOCAL IR CAMERA

A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.

ViewSonic s VG2438Sm is a high performance multimedia display that features full-ergonomic functionality, including -5 to 37 tilt, 360 swivel, 90

Product Information. QUADRA-CHEK 3000 Evaluation Electronics For Metrological Applications

22 (21.5 viewable), 16:9 FHD LED multimedia monitor with SuperClear VA technology. VA2265Sm-3

Nederland België / Belgique

WAVELENGTH OF LIGHT - DIFFRACTION GRATING

Adjustment functions for both span and shift have been incorporated

22X DSP COLOR ZOOM CAMERA AUTO FOCUS ZOOM CAMERA

EF-S18-135mm f/ IS

VG2435Sm :10 Ergonomic Multimedia Display. Overview. See More, Work More with a 16:10 Aspect Ratio Display

Model SL355 Noise Dosimeter/Datalogger

Monitor_ AutoWhiteAdjustment

Basler. Area Scan Cameras

SOUND LEVEL METER 94405

4-Channel Thermometer / Datalogger

USB 3.0 Camera User s Guide

CHROMA METER CS-200. Instruction Manual

SMART Board interactive whiteboard system

TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions

Infrared Viewers. Manual

Second Display Installation Guide Point-of-Sale Hardware System

Displays. Cathode Ray Tube. Semiconductor Elements. Basic applications. Oscilloscope TV Old monitors. 2009, Associate Professor PhD. T.

Cross-beam scanning system to detect slim objects. 100 mm in

Mirror Mount Video Monitor/Recorder with Front and Rear View Night Cameras PLCMDVR5

3528 SMD LED. Applications. Signal & Symbol Indicators. Illuminations(illuminated advertising & general lighting). Amusement Machines.

1. General Description

A technical overview of the Fuel3D system.

COMPALARM AP GENERAL MAIN FEATURES

"All-In-One" Video Conferencing Solution. Versatile Connectivity with DisplayPort

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS 16290(LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : JUL.03,2001 TOTAL PAGE : 7

Day / Night IR Color Camera User Manual V2.1.0

KIP 720 CIS SCANNING SYSTEM WITH ADVANCED KIP REAL TIME THRESHOLDING TECHNOLOGY

Basler scout AREA SCAN CAMERAS

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

USER GUIDE. LED Light Meter. Model LT45

How To Use A Viewson V2349S Full Hd Ips Display With A 23\" Full Hd Screen

Light Meter (Foot Candles)

haze-gard i The objective standard for a clear view Global communication Reliable and Precise

Instruction Manual for IV-08MTV LCD Color Monitor

VZ-M7 HDMI Field Monitor 7 Class HD LCD

ICC Recommendations for Color Measurement

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

Users Manual Model # English

Basler pilot AREA SCAN CAMERAS

Dome Camera with IR Night Vision

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS 16400(LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : JAN.19,2000 TOTAL PAGE : 7 APPROVED BY:

KIP 720 CIS SCANNING SYSTEM WITH ADVANCED KIP REAL TIME THRESHOLDING TECHNOLOGY

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

KS732 Family. Rev KS732. 1/3 CCD Color USB Camera

Integrating Sound Level Meter and Datalogger

Motion Activated Camera User Manual

SMART Board interactive flat panel with appliance Model 8055ie-SMP

APPLICATION NOTE. Basler racer Migration Guide. Mechanics. Flexible Mount Concept. Housing

Handheld USB Digital Endoscope/Microscope

Transcription:

Spectroradiometer CS-000/000A The world's top-level capability spectroradiometers make further advances with addition of second model to lineup. 16

World's top level capability to detect extremely low luminance * As a polychromator type spectroradiometer (As of March 014) 1,000,000:1 contrast measurement is now possible! * When the peak luminance is 500 cd/m CS-000A Opening the curtain on a new age in which people can experience theater ambiance with their home televisions. The Spectroradiometer CS-000A enables high-accuracy mega-contrast measurements of the extremes from delicate shadows to glittering wavefronts which are key to image reproduction performance. This newest addition to the Konica Minolta lineup will contribute greatly to research and development as well as quality control of the most advanced FPDs. 0.0005 cd/m opens new worlds With an additional decimal place of performance in measuring low luminosity even compared to our CS-000, which was awarded the ADY 008 grand prize, the CS- 000A helps open up a new stage of display development by enabling the measurement of contrast ratios up to 1 million to 1*1 which is being targeted by the latest FPD technology. *1 Maximum luminance 500 cd/m Measurement example: Measurement of an organic EL illumination panel during development Instruments that push the extreme boundaries of practical application and cost performance to support design and development work. CS-000 Highly accurate measurement of luminances as low as 0.003 cd/m Konica Minolta's original optical design and signal-processing technologies provide accurate measurement of luminance/ chromaticity down to extremely low luminances of 0.003 cd/m. Low-luminance measurements: From 0.003 cd/m Measurement accuracy: ±% (Luminance) Quick measurements even at low luminance Designed to thoroughly eliminate mechanical and electrical noise factors, the CS-000 makes quick measurements with good repeatability possible even at low luminance levels. Measurement time for 1 cd/m : Approx. 5 sec. (FAST mode) * Konica Minolta's previous model CS-1000: Approx. 13 sec. Low polarization error The polarization error generated when using a reflection-type diffraction grating has been minimized to % (measuring angle: 1 ). This ensures more stable measurements of display devices that use polarization, such as LCDs. Half bandwidth of 5 nm A half bandwidth of 5 nm, which is required for colorimetry (JIS Z 874-1997, CIE1-1996), is ensured for the entire wavelength range, allowing accurate chromaticity measurements. Selectable measuring angle for measurement of tiny areas The CS-000 enables you to select the optimum measuring angle according to the application. Measuring angle selection: 1, 0., 0.1 Minimum measuring area: ø0.1 mm ( when the optional closeup lens is attached) Practical design The operating temperature range of 5 to 35 C ensures reliable operation at temperatures in actual work environments. Measurement can be started after a warm-up time of only 30 seconds. (Measuring angle: 1 ; Target luminance: 5 cd/m or more; 3 C) Stable measurement even of periodic light sources 1. Internal synchronization measurement Measurement at numerically-input frequency. External synchronization measurement Measurement with line input of vertical synchronization signal to instrument 3. Multi-integration mode measurement Measurement for reducing variations due to unsynchronized measurements or synchronized measurements of sources having irregular light-emission cycles

Measurements of various objects are possible by selecting the best-suited measuring angle. 1 is suitable for 0. is suitable for 0.1 is suitable for Typical targets such as middle- and large-size display units LCD, PDP, or EL display panels LCD panels of cellular phones and digital cameras Radar and other instrument panels used in airplane cockpits Large outdoor display screens Small light sources such as LEDs Car audio systems Instrument panels for automobiles Lamps, fluorescent tube backlights, and other light sources Extremely small light sources or distant lights PDP or LCD pixels Cold-cathode tubes Brake lamps of automobiles Traffic signals Measuring diameter viewed through viewfinder LCD pixels Measurement Examples PDP LCD Organic EL Close-up lens for measurement of even tinier areas (Optional accessory) Optional close-up lens allows measurements of areas as tiny as ø0.1 mm. Not only general display units but also small targets can be measured. Measuring distance vs. measuring area (Units: mm) Measuring distance Measuring angle 1 0. 0.1 When a close-up lens 55.0 ø1.00 ø0.0 ø0.10 is attached 70.9 ø1.39 ø0.8 ø0.14 350 ø5.00 ø1.00 ø0.50 500 ø7.78 ø1.56 ø0.78 1,000 ø16.66 ø3.33 ø1.67,000 ø34.18 ø6.84 ø3.4 * The measuring distance is the distance from the objective lens or the end of the metal frame of the close-up lens.

Comparison of repeatability * Comparison with Konica Minolta's previous model CS-1000 for target luminance of 0.1 cd/m * The y-axis indicates the logarithm when the average of the CS-000 measured values is assumed to be 1. Luminance ( Lv ) Chromaticity ( x ) Chromaticity ( y ) Average repeatability (logarithm) 100 10 1 0.1 CS-1000 Difference: 4.7 times CS-000 Average repeatability (logarithm) 100 10 1 0.1 CS-1000 Difference: 34.7 times CS-000 Average repeatability (logarithm) 100 10 1 0.1 CS-1000 Difference: 4.3 times CS-000 High repeatability achieved by an instrument design which thoroughly eliminated mechanical and electrical noise factors. Scotopic vision measurement It is known that the sensitivity of human vision shifts to blue region in dark environments, but past instruments did not have scotopic measurement function. CS-000A achieves sufficient capability to make it possible with CS-S10w Professional (standard accessory). Scotopic vision In the human eye, there are types of photoreceptor cells, which are cone cells and rod cells. Cone cells are sensitive to color and rod cells are sensitive to only brightness. As brightness decreases, the activity of rod cells becomes stronger, and the condition in which only rod cells are working is called scotopic vision. The peak of spectral luminous efficiency of scotopic vision is shifted toward blue from the green peak of photopic vision (vision under brighter conditions) and thus blue objects are perceived to be brighter. CIE Spectral luminous intensity 1. 1.0 0.8 0.6 0.4 0. 0.0 380 411 44 473 504 535 566 597 68 659 Photopic Scotopic 690 71 75 Wavelength [nm] Measured luminance vs. Measurement times (Units: sec.) Luminance (cd/m ) NORMAL mode FAST mode 0.003 43 35 0.01 43 35 0.1 155 7 1 19 5 10 4 4 300 3.7 3.7 Measurement subject: Standard light source A * All time indications are approximate values. Using as a reference instrument CS-000/CS-000A can be used as a reference instrument for Konica Minolta's Illuminance Meters in various industrial fields. CS-00 CS-100A Reference instrument CA-500A CA-310 System Diagram Standard accessories Optional accessories ND filter (1/10) CS-A33 (1/100) CS-A34 Lens Cap Screw for focus ring look CS-A38 CS-000 main unit Calibration certificate 3-point calibration certificate Eyepiece with ND filter CS-A1 CCD Camera Adapter CS-A36 Close-up lens CS-A35 USB cable ( m) CS-A3 Pan Head CS-A4 AC Adapter White Calibration Plate CS-A5 (without data) CS-A5 (with data) CS-A5 (with data and calibration certificate) Storage Case CS-A30 Tripod CS-A3 PC (commercially available) Data Management Software CS-S10w Professional Edition

Easy operation with color LCD screen and simple operation panel The color LCD screen and operation panel are located at the rear of the instrument. The simply arranged operation panel enables intuitive selection of necessary functions. Color space mode screen Lv 30. 79 x 0. 311 cd m Color LCD screen Menu screen Simple operation The desired function can be called intuitively. y 0. 3404 Lv 30. 79 T 607K cd m Easy connection via USB duv +0. 005 Data Management Software CS-S10w Professional (Standard accessory) With this software, the CS-000 and CS-000A can be controlled from a personal computer to display measured data in various graphs or lists, to transfer data to spreadsheet software, or to copy-and-paste data. CS-S10w offers various data management, analysis and evaluation options to assist in research and development or quality control. Template showing xy and u'v' chromaticity diagrams Multiple data objects can be copied and pasted to spreadsheet software. Windows is a trademark or registered trademark of Microsoft Corporation in the USA and other countries. Pentium is a trademark of Intel Corporation in the USA and other countries. Display Color space Calculation Mode selection Spectral graph, spectral data list, chromaticity diagram L v xy, L v u'v', L v T uv, XYZ, dominant wavelength, excitation purity, scotopic luminosity Four basic arithmetic operations and function processing of spectral data Normal mode, contrast mode, RGB mode, RGB & contrast mode, object color mode Instrument control Averaging measurement, interval measurement, user calibration Data management Reading/saving files; managing data by using folders; creating, saving and reading templates with various graphs designed and laid-out by users; displaying data with graphs Data evaluation Observer/illuminant setting, color rendering property evaluation, statistic value display for each folder, box tolerance setting, multiple point setting for display evaluation, non-uniformity (mura) display, contrast display, polygonal tolerance setting System requirements OS Windows XP Professional 3 bit SP3, 64 bit SP Windows 7 Professional 3 bit, 64 bit Windows 8 Pro 3 bit, 64 bit CPU Pentium III 600 MHz equivalent or faster Memory 18 MB or more (56 MB or more recommended) Hard disk 60 MB or more of free space for installation Display 1,04 x 768, 56 colors minimum Other CD-ROM drive for installation, USB port for instrument connection

65 Main specifications of CS-000/000A Model CS-000/000A Wavelength range 380 to 780 nm Wavelength resolution 0.9 nm/pixel Display wavelength bandwidth 1.0 nm Wavelength precision ±0.3 nm (Median wavelength: 435.8 nm, 546.1 nm, 643.8 nm; Hg-Cd lamp) Spectral bandwidth 5 nm or less (half bandwidth) Measuring angle (selectable) 1 0. 0.1 Measurement luminance CS-000 0.003 to 5,000 cd/m 0.075 to 15,000 cd/m 0.3 to 500,000 cd/m range (Standard light source A) CS-000A 0.0005 to 5,000 cd/m 0.015 to 15,000 cd/m 0.05 to 500,000 cd/m Minimum measuring area ø5 mm ø1 mm ø0.5 mm (ø1 mm when using close-up lens) (ø0. mm when using close-up lens) (ø0.1 mm when using close-up lens) Minimum measuring distance 350 mm (55 mm when using close-up lens) Minimum spectral radiance display 1.0x10-9 W/sr, m, nm Accuracy: Luminance (Standard light source A)*1 ±% x,y : ±0.003 (0.003 to 0.005 cd/m ) x,y : ±0.003 (0.075 to 0.15 cd/m ) x,y : ±0.003 (0.3 to 0.5 cd/m ) Accuracy: Chromaticity x,y : ±0.00 (0.005 to 0.05 cd/m ) x,y : ±0.00 (0.15 to 1.5 cd/m ) x,y : ±0.00 (0.5 to 5 cd/m ) (Standard light source A)*1 x : ±0.0015 x : ±0.0015 x : ±0.0015 (0.05 cd/m (1.5 cd/m (5 cd/m 0.4% (0.003 to 0.05 cd/m Repeatability: Luminance (σ) ) 0.4% (0.075 to 1.5 cd/m ) 0.4% (0.3 to 5 cd/m ) 0.3% (0.05 to 0.1 cd/m (Standard light source A)* ) 0.3% (1.5 to.5 cd/m ) 0.3% (5 to 10 cd/m ) 0.15% (0.1 to 5,000 cd/m ) 0.15% (.5 to 15,000 cd/m ) 0.15% (10 to 500,000 cd/m ) CS-000 CS-000A Repeatability: Chromaticity (σ) (Standard light source A)* x,y : 0.00 (0.003 to 0.005 cd/m ) x,y : 0.001 (0.005 to 0.1 cd/m ) x,y : 0.0006 (0.1 to 0. cd/m ) x,y : 0.0004 (0. to 5,000 cd/m ) x,y : 0.00 (0.075 to 0.15 cd/m ) x,y : 0.001 (0.15 to.5 cd/m ) x,y : 0.0006 (.5 to 5 cd/m ) x,y : 0.0004 (5 to 15,000 cd/m ) x,y : 0.00 (0.3 to 0.5 cd/m ) x,y : 0.001 (0.5 to 10 cd/m ) x,y : 0.0006 (10 to 0 cd/m ) x,y : 0.0004 (0 to 500,000 cd/m ) x,y :±0.00 (0.001 to 0.05 cd/m Accuracy: Chromaticity ) x,y : ±0.00 (0.05 to 1.5 cd/m ) x,y : ±0.00 (0.1 to 5 cd/m ) x : ±0.0015 x : ±0.0015 x : ±0.0015 (Standard light source A)*1 (0.05 cd/m (1.5 cd/m (5 cd/m 1.5% (0.0005 to 0.001 cd/m ) 1.5% (0.015 to 0.05 cd/m ) 1.5% (0.05 to 0.1 cd/m ) Repeatability: Luminance (σ) 0.7% (0.001 to 0.003 cd/m ) 0.7% (0.05 to 0.075 cd/m ) 0.7% (0.1 to 0.3 cd/m ) (Standard light source A)* 0.5% (0.003 to 0.05 cd/m ) 0.15% (0.05 to 5,000 cd/m ) 0.5% (0.075 to 1.5 cd/m ) 0.15% (1.5 to 15,000 cd/m ) 0.5% (0.3 to 5 cd/m ) 0.15% (5 to 500,000 cd/m ) Repeatability: Chromaticity (σ) (Standard light source A)* x: 0.003 y:0.0035 (0.001 to 0.003 cd/m ) x: 0.001 y:0.0015 (0.003 to 0.1 cd/m ) x,y: 0.0006 (0.1 to 0. cd/m ) x,y: 0.0004 (0. to 5,000 cd/m ) x: 0.003 y: 0.0035 (0.05 to 0.075 cd/m ) x: 0.001 y: 0.0015 (0.075 to.5 cd/m ) x,y: 0.0006 (.5 to 5 cd/m ) x,y: 0.0004 (5 to 15,000 cd/m ) x: 0.003 y: 0.0035 (0.1 to 0.3 cd/m ) x: 0.001 y: 0.0015 (0.3 to 10 cd/m ) x,y : 0.0006 (10 to 0 cd/m ) x,y : 0.0004 (0 to 500,000 cd/m ) Polarization error 1 : % or less (400 to 780 nm); 0.1 and 0. : 3% or less (400 to 780 nm) Integration time Fast: 0.005 to 16 sec.; Normal: 0.005 to 10 sec. Measurement time CS-000 : Approx. sec. minimum (Manual mode) to 43 CS-000A : Approx. sec. minimum (Manual mode) to sec. maximum (Normal mode) 47 sec. maximum (Normal mode) Color space L v xy, L v u'v', L v T uv, XYZ, spectral graph, dominant wavelength, excitation purity, scotopic luminosity (with CS-S10w Professional) Interface USB 1.1 Operation temperature/ CS-000 : 5 to 35 C, relative humidity 80% or less with CS-000A : 5 to 30 C, relative humidity 80% or less with humidity range no condensation no condensation Storage temperature/humidity range 0 to 35 C, relative humidity 80% or less with no condensation Power AC Adapter (100-40 V, 50/60 Hz) Current consumption Approx. 0 W Size (W x H x D) 158 x 00 x 300 mm (Main unit), ø70 95 mm (Lens) Weight 6. kg *1: Average of 10 measurements in Normal mode at a temperature of 3± C and a relative humidity of 65% or less. *: 10 measurements in Normal mode at a temperature of 3± C and a relative humidity of 65% or less. Dimensions (Units: mm) 67.4 Filter thread diameter: ø5 10.5 19 50 47 79 158 Reference for measuring distance 95.7 9.5 Mounting screw: M5, Depth: 6.5 Mounting screw: M5, ø15 Depth: 6.5 51 58.5 300 39 00 53 9 Optical axis Positioning pin hole (1): ø5, Depth: 4 70 170 190.4 90 Positioning pin hole (): Depth: 4 Tripod screw (ø3/8-inch screw) SAFETY PRECAUTIONS For correct use and for your safety, be sure to read the instruction manual before using the instrument. Always connect the instrument to the specified power supply voltage. Improper connection may cause a fire or electric shock. The specifications and appearance shown herein are subject to change without notice. Some lamp control methods may make accurate measurements difficult. For details, please contact your nearest Konica Minolta sales office or dealer. Certificate No : LRQ 0960094/A Registration Date : March 3, 1995 Certificate No : JQA-E-8007 Registration Date : March 1, 1997 007-016 KONICA MINOLTA, INC. 94-489-10 BGEPK Printed in Japan