Design Rationale and Surgical Technique



Similar documents
Design surgeon list. Smith & Nephew thanks the following surgeons for their participation as part of the R3 system design team:

ACCORD Cable System. Surgical technique completed in conjunction with: Robert Barrack, MD St. Louis, Missouri. Paul Di Cesare, MD New York, New York

Accolade. System. Brochure. Achieving Perfect Balance. Cemented and Cementless Femoral Hip System

Metasul LDH Large Diameter Head

ACCOLADE II. Orthopaedics. Femoral Hip System. Surgical Technique

BONE PRESERVATION STEM

The information contained in this document is intended for healthcare professionals only.

Acetabular Wedge Augment System

Total Hip Joint Replacement. A Patient s Guide

VERSYS HERITAGE CDH HIP PROSTHESIS. Surgical Technique for CDH Hip Arthroplasty

Why an Exactech Hip is Right for You

ReCap Product Rationale

Achilles Tendon Repair, Operative Technique

MDM. Surgical Technique. Modular Dual Mobility Acetabular System. Orthopaedics

Zimmer M/L Taper Hip Prosthesis. Surgical Technique

DRAFT. Triathlon TS Knee System. Surgical Protocol. Version 1

MDMTM. Surgical Technique. Modular Dual Mobility TM Acetabular System. Orthopaedics

Y O U R S U R G E O N S. choice of. implants F O R Y O U R S U R G E R Y

VERILAST Technology for Hip Replacement Implants

Modular Dual Mobility Acetabular Components: An Important Extension of a Proven Approach to Hip Instability

Rejuvenate Total Hip System Surgical Protocol. Rejuvenate Modular Hip Stem Enhanced Stability 1 Proven Modularity 2 Intraoperative Flexibility

INTRODUCTION Cerclage Cable Vs. Monofilament Wire

Minimally Invasive Hip Replacement through the Direct Lateral Approach

Patient Labeling Information System Description

Introduction to the Bertram Hip Spacer

P REPLACEMENT SURGERY

Exeter X3 RimFit. Acetabular Cup Surgical Protocol

Metal-on-Metal Hip Systems

The information contained in this document is intended for healthcare professionals only.

The information contained in this document is intended for healthcare professionals only.


Total Hip Replacement

Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology

Restoration Modular Cone Body/Conical Distal Stem Femoral Components Using the Restoration Modular Instrument System Surgical Technique

Trident Acetabular System Hemispherical Surgical Protocol

HEADER TOTAL HIP REPLACEMENT SURGERY FROM PREPARATION TO RECOVERY

Exeter. Surgical Technique. V40 Stem Cement-in-Cement. Orthopaedics

FUSEFORCE. Hand Fixation System SURGIC A L T ECHNIQUE

Zimmer MOST Options System

Foot and Ankle Technique Guide Proximal Inter-Phalangeal (PIP) Fusion

Posterior Referencing. Surgical Technique

Arthroscopic Shoulder Instability Repair Using the SUTUREFIX ULTRA Suture Anchor and SUTUREFIX ULTRA Instrumentation System

TOTAL HIP REPLACEMENT FOR A LIFETIME: THE CEMENTLESS METAL ON METAL RECONSTRUCTION

Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology. Surgical Technique

Clinically Proven Fiber Metal Material. Power to choose advanced bearing technologies to match patient demands

YOUR GUIDE TO TOTAL HIP REPLACEMENT

Lentur Cable System. Surgical Technique

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE. Health Technology Appraisal

The Right Choice. Exeter. total hip system

Anterior Hip Replacement

Restoration Modular. Revision Hip System Surgical Protocol

Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery.

Knotilus TM. Anchor Instability Repair. Technique Guide

Anterior Lumbar Interbody Fusion (ALIF). Instrument set supports placement of ALIF spacers using anterior or anterolateral approach.

Zimmer Persona Adverse Events Reported to FDA Through 3/27/2015

TOTAL HIP REPLACEMENT

How To Use A Phoenix Retrograde Femoral Nail

Zimmer Segmental System. Distal Femoral Surgical Technique

PROCOTYL L. Acetabular Cup System

Zimmer FuZion Instruments. Surgical Technique (Beta Version)

*smith&nephew SLR-PLUS

Failure Mechanisms and Closed Reduction of a Constrained Tripolar Acetabular Liner

DHCPL_RA EXT Page 1 of 6

TRIGEN INTERTAN Intertrochanteric Antegrade Nail Surgical Technique. Table of Contents

Surgical technique. Sagitta EVL

.org. Arthritis of the Hand. Description

Bankart Repair using the Smith & Nephew BIORAPTOR 2.9 Suture Anchor

PERIPROSTHETIC IMPLANTS

Technique Guide. DHS/DCS Dynamic Hip and Condylar Screw System. Designed to provide stable internal fixation.

After Hip Arthroscopy

Wrist and Hand. Patient Information Guide to Bone Fracture, Bone Reconstruction and Bone Fusion: Fractures of the Wrist and Hand: Carpal bones

TRIGEN INTERTAN vs Stryker Gamma3 summary

Aesculap Veterinary Orthopaedics. Targon VET Interlocking Nail

TRIGEN TAN and FAN Intramedullary Nails

Technique Guide. Reamer/Irrigator/Aspirator (RIA). For intramedullary reaming and bone harvesting.

Zimmer Small Fragment Universal Locking System. Surgical Technique

MINI FRAGMENT SYSTEM. Instruments and implants for 1.5 mm, 2.0 mm, and 2.4 mm plate fixation PRODUCT OVERVIEW

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE

High-Flex Solutions for the MIS Era. Zimmer Unicompartmental High Flex Knee System

TwinFix Cannulated Compression Screw

the revo / mini-revo shoulder fixation system s u r g i c a l t e c h n i q u e

AMPSEAL* Automotive Plug Connector and Header Assembly

frequently asked questions Knee and Hip Joint Replacement Technology

BIRMINGHAM HIP Resurfacing (BHR ) System PATIENT INFORMATION

Zimmer Trilogy IT Acetabular System

it s time for rubber to meet the road

Robotic-Arm Assisted Surgery

Technique Guide. VersiTomic. Michael A. Rauh, MD. Anterior Cruciate Ligament Reconstruction

The information contained in this document is intended for healthcare professionals only.

.URGENT DEVICE CORRECTION

LK Wallbox UNI Push. Assembly. Only intended for LK PE-X Universal Pipe X.

PINNACLE. Polyethylene Surgical Technique. Surgical Technique

Drive shaft, servicing

INTUITION INSTRUMENTS SURGICAL TECHNIQUE

Technique Guide. Orthopaedic Cable System. Cerclage solutions for general surgery.

NCB Distal Femur System. Surgical Technique

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

Transcription:

Design Rationale and Surgical Technique

Maximizing performance from every angle Saving time in the operating room is one of the most valuable solutions Smith & Nephew can provide surgeons. The TANDEM BIPOLAR and UNIPOLAR hip systems dramatically increases efficiency with an easy-to-assemble bipolar design, one-tray instrumentation and a variety of operative options. The TANDEM BIPOLAR and UNIPOLAR hip systems is one of the most comprehensive and effective partial hip system seen on the market in years. The TANDEM BIPOLAR and UNIPOLAR hip systems addresses performance from a multitude of angles. By integrating superior features into the new product design the TANDEM BIPOLAR minimizes wear, eliminates poly degradation and maximizes range of motion. Nota Bene: The technique description herein is made available to the healthcare professional to illustrate the authors suggested treatment for the uncomplicated procedure. In the final analysis, the preferred treatment is that which addresses the needs of the patient.

Introduction David Jacofsky, MD Director, Orthopedic Traumatology, Mayo Clinic School of Medicine Steven H. Stern, MD Clinical Associate Professor of Orthopedic Surgery, Northwestern University, Northwestern Memorial Hospital Hemiarthroplasty of the hip involves replacement of the diseased, affected, or broken femoral head and/or neck with a prosthetic component. Hemiarthroplasty does not involve resurfacing of the acetabulum, and therefore a bipolar or unipolar prosthetic head articulates against the host acetabular articular cartilage. Avoiding the need, when appropriate, to resurface the acetabulum helps to minimize surgical trauma, operative time and dislocation risk, while preserving acetabular bone stock. Intracapsular hip fractures may be amenable to internal fixation in appropriately chosen patients. However, many fractures of the femoral head and femoral neck are unsuitable for internal fixation due to the patient s bone quality, fracture displacement, fracture chronicity, or due to pre-existing patient medical comorbidities. In these situations, pain relief, mobility, and patient outcome may be best served with prosthetic replacement. In addition, certain hip pathology outside traumatic indications may benefit from hemiarthroplasty of the hip.

TANDEM BIPOLAR Hip System Design features Superior wear performance The TANDEM BIPOLAR system offers wear features unique to Smith & Nephew. To minimize micromotion at the periphery of the shell, the TANDEM BIPOLAR system integrates an anti-rotation boss on the top polyethylene ring with an indentation on the metal shell. The TANDEM BIPOLAR system minimizes rotational and axial movement at the liner-shell interface by incorporating a preassembled polyethylene component into the shell. In addition, the TANDEM BIPOLAR system meets the minimum requirement for polyethylene thickness as stated by Bartel, 1 incorporating a minimum of 5mm of polyethylene in a majority of sizes. Poly thickness combined with the preassembled poly component and the anti-rotation feature provide superior wear performance. Unique sterilization To reduce the potential for degradation of the polyethylene liner, the TANDEM BIPOLAR system is EtO sterilized. This patent-pending feature eliminates the susceptibility of the liner to oxidation caused by gamma sterilization. Maximum ROM Smith & Nephew understands that range of motion (ROM) is not dependent upon neck design alone. The wide liner chamfer of the TANDEM BIPOLAR system, which is similar to the chamfer of REFLECTION liners, allows maximum ROM when combined with Smith & Nephew stems. Internal testing has shown that the TANDEM BIPOLAR system design improves ROM over competitive offerings. 2 ROM ID (mm) OD (mm) Neck Offset TANDEM 82º 28 51 +0 TANDEM 88º 28 59-3 Competitor A 70º 28 60-3* Competitor B 68º 28 58-3.5 Competitor C 66º 28 51 +0 * Smith & Nephew femoral head used. 2 1 Bartel, DL; Burstein, AH; Toda, MD; Edwards, DL: The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants. J Biomech Eng. 1985 Aug; 107(3):193-9. 2 Smith & Nephew internal testing.

Easy implant assembly To improve efficiency in the operating room, the TANDEM BIPOLAR system was designed for easy implant assembly, requiring no tools to assemble the bipolar component. The simple and quick assembly requires less than five pounds of finger pressure. More options The TANDEM Bipolar implants are designed to work with either 22mm or 28mm femoral heads, depending on the outer diameter shell size. The 22mm femoral heads are offered in four neck lengths, ranging from +0 to +12mm. Available in six neck lengths, the 28mm ranges from -3 to +16mm. The TANDEM BIPOLAR system is available in a variety of sizes, increasing operative options. The implants are offered in 38-42mm outer diameters, which use a 22mm inner diameter head. The 28mm inner diameter heads are coupled with the 43-55, 57 and 59mm sizes. Unsurpassed mechanical strength The strength characteristics of the TANDEM BIPOLAR system are superior to that of competitive designs. Internal testing shows that the TANDEM Bipolar has average maximum pullout strength of 400 lbf. with a 28mm femoral head, which exceeds or meets the strength of tested competitive designs. 2 Positive eccentricity The positive eccentricity in the TANDEM BIPOLAR system design aligns the femoral head with the joint reaction force of the body. The amount of eccentricity is varied based on inner and outer diameter dimensions of the bipolar component. Biocompatible material The TANDEM BIPOLAR system is cast and machined out of standard cobalt-chrome material, a wear resistant and biocompatible material that has been used for years in medical device implants. Pullout Load (lbf) 500 400 300 200 100 0 BIPOLOR Implants Competitor A TANDEM 3

TANDEM UNIPOLAR Hip System Design features The TANDEM UNIPOLAR system provides a complete, yet streamlined, option for surgeons whose preference in partial hip replacement is a unipolar endoprosthesis. The TANDEM UNIPOLAR system can be used with a variety of Smith & Nephew stems, providing independent sizing of the acetabulum and femur. If needed, this allows re-establishment of proper soft-tissue tensioning and revision without stem removal. Wear resistant and biocompatible The TANDEM UNIPOLAR system head is offered in OXINIUM technology and cobalt chrome in a range of OD sizes from 40-55mm. Sizes 57 and 59 are available in cobalt chrome only. Versatile To achieve proper joint restoration, the taper sleeves are provided in five neck lengths ranging from -3 to +12mm. 4

TANDEM system instrumentation One-tray Instrumentation The simple, one-tray instrumentation design incorporates two trialing techniques into one system. Maximizing efficiency in the operating room, this design facilitates fast and easy trialing for either procedure. TANDEM trial shells Designed for dimensional stability, the TANDEM system trial shells perform accurately after repeated sterilization. In addition, the interchangeability of the femoral head trials (included in the femoral instrument set) and unipolar conversion sleeves with the trial shells increases the versatility of the instruments. The trial shells are also threaded for surgeons who prefer to perform a suction test. TANDEM UNIPOLAR Conversion Sleeves TANDEM Unipolar Conversion Sleeves allow easy conversion of the trial shells into a unipolar trial quickly and efficiently. The sleeves snap directly into the trial shell and can be easily removed using the tip of the trial handle. TANDEM Quick-Connect Trial Handle The TANDEM Quick-Connect Trial Handle (pictured) is designed to allow the trial shells to snap off quickly for a more efficient procedure and provides more visibility inside the wound. A straight threaded trial handle is also available for surgeons who prefer additional security in their trialing technique. Ring Spreader The Ring Spreader is used to disassemble the bipolar when there is a need to change femoral head neck lengths or for the removal of the bipolar component. Unipolar Taper Sleeve Removal Tool The Unipolar Taper Sleeve Removal Tool threads into the top portion of the taper sleeve and is used to release the taper sleeve from the stem neck. 5

TANDEM BIPOLAR Hip System Surgical Technique Acetabular measurement To estimate acetabular size, use preoperative templates or measure the excised femoral head with ID/OD gauges or calipers. To determine implant size, acetabular measurement can be performed with TANDEM Trial Shells and the angled quick-connect trial handle. A straight threaded handle is also available. BIPOLAR trial options Broach and implant trialing Follow the surgical technique for the Smith & Nephew femoral component to be used. Neck length trialing can be performed using TANDEM Trial Shells and 28mm trial femoral heads (included in the femoral instrument set). Broach Implant Trialing can be performed off either the broach (using the appropriate trial neck) or the implant. Based on preoperative templating, select a trial head neck length and perform a trial reduction. Continue adjusting the trial femoral head neck length until proper leg length and joint stability are achieved. Trial removal To remove the femoral trial head from the trial shell, insert the tip of the trial handle into the outer portion of the threaded hole of the trial shell. 6

Femoral head selection For instrument simplicity, all bipolar trialing utilizes 28mm trial femoral heads. The implant sizes change with the OD. To ensure adequate poly thickness, a 22mm femoral head must be used with a 38-42mm OD. A 28mm femoral head requires 43mm and larger ODs. TANDEM Bipolar Selection OD 38, 39mm 40-42mm 43-55mm 57, 59mm ID Trial 28mm 28mm ID Implant 22mm 22mm 28mm 28mm TANDEM BIPOLAR assembly The TANDEM BIPOLAR component (shell and liner) is packaged in one box. Place the appropriate ID femoral head, corresponding to the outer diameter and appropriate neck length, into the preassembled metal-polyethylene bipolar shell. To ensure proper alignment of the anti-rotation boss, place the polyethylene top-locking ring over the femoral head so that the notch on the polyethylene aligns with the notch on the metal shell component. Making sure the poly ring is not tilted, ease the poly lock ring into the shell. Check the alignment of the notches again. Using finger pressure, gently press down on the poly lock ring until an audible click is heard. Click The poly lock ring should be flush with the metal shell. 7

TANDEM BIPOLAR Hip System Surgical technique Implant assembly Clean and dry the stem taper. Place the fully assembled bipolar onto the stem taper and tap with the femoral head impactor until secure. Bipolar disassembly: back table Holding the assembled bipolar over a clean, secure surface, place the tip of the ring spreader into the disassembly notch of the bipolar component. By squeezing the handles of the ring spreader, the inner snap ring will expand, allowing the top poly ring to disengage. If necessary, gently shake the component until the poly ring is disengaged and the femoral head is released. Bipolar disassembly: In Vivo Place the tip of the ring spreader into the disassembly notch of the bipolar component. Squeezing the handles of the ring spreader, slightly push in to release the retaining ring. While holding the retaining ring open, gently lift the bipolar metal shell until the top poly ring is disengaged. 8

TANDEM UNIPOLAR Hip System Surgical technique Acetabular measurement To estimate acetabular size, use preoperative templates or measure the excised femoral head with ID/OD gauge or calipers. To determine implant size, acetabular measurement can be performed with TANDEM Trial Shells and the angled quick-connect trial handle. A straight threaded handle is also available. Broach and implant trialing Follow the surgical technique for the Smith & Nephew femoral component to be used. Neck length trialing can be performed using TANDEM Trial Shells and TANDEM UNIPOLAR Conversion Sleeves. UNIPOLAR trial options UNIPOLAR neck offset options -3, +0, +4, +8, +12mm Trialing can be performed off either the broach (using the appropriate trial neck) or the implant. Based on preoperative templating, select the appropriate unipolar conversion sleeve and perform a trial reduction. Continue adjusting the unipolar conversion neck length until proper leg length and joint stability are achieved. Broach Implant Trial removal To remove the TANDEM UNIPOLAR Conversion Sleeve from the trial shell, insert the tip of the trial handle into the outer portion of the threaded hole of the trial shell. 9

TANDEM UNIPOLAR Hip System Surgical technique Implant assembly Clean and dry the stem taper. Firmly place the taper sleeve on the femoral taper. Clean and dry the taper sleeve and place the appropriate size unipolar head onto the sleeve. Impact with the femoral head impactor and mallet. Implant disassembly After removing the unipolar head from the taper sleeve, thread the Unipolar Taper Sleeve Removal Tool into the top of the taper sleeve implant until it contacts the femoral taper. Continue turning until the sleeve separates from the stem. 10

Catalog Information Implants TANDEM BIPOLAR implant (Cobalt Chrome/UHMWPE) Cat. no. Outer Inner diameter diameter 7132-2038 38mm 22mm 7132-2039 39mm 22mm 7132-2040 40mm 22mm 7132-2041 41mm 22mm 7132-2042 42mm 22mm 7132-2043 43mm 28mm 7132-2044 44mm 28mm 7132-2045 45mm 28mm 7132-2046 46mm 28mm 7132-2047 47mm 28mm 7132-2048 48mm 28mm 7132-2049 49mm 28mm 7132-2050 50mm 28mm 7132-2051 51mm 28mm 7132-2052 52mm 28mm 7132-2053 53mm 28mm 7132-2054 54mm 28mm 7132-2055 55mm 28mm 7132-2057 57mm 28mm 7132-2059 59mm 28mm TANDEM UNIPOLAR implant (Cobalt Chrome) Cat. no. Outer diameter 12-6640 40mm 12-6641 41mm 12-6642 42mm 12-6643 43mm 12-6644 44mm 12-6645 45mm 12-6646 46mm 12-6647 47mm 12-6648 48mm 12-6649 49mm 12-6650 50mm 12-6651 51mm 12-6652 52mm 12-6653 53mm 12-6654 54mm 12-6655 55mm 12-6657 57mm 12-6659 59mm 12-6661 61mm 12/14 Taper Femoral Heads (Cobalt Chrome) Cat. no. Outer Neck diameter length 7130-2200 22mm +0mm 7130-2204 22mm +4mm 7130-2208 22mm +8mm 7130-2212 22mm +12mm 7130-2803 28mm -3mm 7130-2800 28mm +0mm 7130-2804 28mm +4mm 7130-2808 28mm +8mm 7130-2812 28mm +12mm 7130-2816 28mm +16mm TANDEM UNIPOLAR 12/14 Taper Sleeves Cat. no. Neck length 7132-6603 -3mm 7132-6600 +0mm 7132-6604 +4mm 7132-6608 +8mm 7132-6612 +12mm TANDEM OXINIUM Unipolar Cat. no. Outer diameter 7132-1040 40mm 7132-1041 41mm 7132-1042 42mm 7132-1043 43mm 7132-1044 44mm 7132-1045 45mm 7132-1046 46mm 7132-1047 47mm 7132-1048 48mm 7132-1049 49mm 7132-1050 50mm 7132-1051 51mm 7132-1052 52mm 7132-1053 53mm 7132-1054 54mm 7132-1055 55mm 11

Catalog Information Instruments TANDEM Trial Shells Cat. no. Outer Diameter 7136-3040 40mm 7136-3041 41mm 7136-3042 42mm 7136-3043 43mm 7136-3044 44mm 7136-3045 45mm 7136-3046 46mm 7136-3047 47mm 7136-3048 48mm 7136-3049 49mm 7136-3050 50mm 7136-3051 51mm 7136-3052 52mm 7136-3053 53mm 7136-3054 54mm 7136-3055 55mm 7136-3057 57mm 7136-3059 59mm Ring Spreader Cat. no. 7136-2802 TANDEM Quick-Connect Trial Handle Cat. no. 7136-2803 TANDEM Straight Threaded Trial Handle (Not Shown) Cat. no. 7136-2804 Unipolar Taper Sleeve Removal Tool Cat. no. 11-6608 TANDEM Instrument Tray TANDEM Unipolar Conversion Sleeves Cat. No. Description 7136-7903 -3mm Cat. No. 7136-2805 TANDEM Instrument Set Cat. No. 7131-1002 7136-7900 +0mm 7136-7904 +4mm 7136-7908 +8mm 7136-7912 +12mm TANDEM CoCr Bipolar Implant Set (Not Shown) Cat. No. 7131-9929 TANDEM OXINIUM Unipolar Implant Set (Not Shown) Cat. No. 7131-9937 TANDEM CoCr Unipolar Implant Set (Not Shown) Cat. No. 7131-9916 12

Notes 13

Orthopaedic Reconstruction & Trauma Smith & Nephew, Inc. 1450 Brooks Road Memphis, TN 38116 USA www.smith-nephew.com Telephone: 1-901-396-2121 Information: 1-800-821-5700 Orders/inquiries: 1-800-238-7538 2008 Smith & Nephew, Inc. All rights reserved. 45620401-2 7138-0918 07/08 Trademark of Smith & Nephew. Reg. US Pat. & TM Off.