Patient Fit is Now an Option. Zimmer Natural Nail System

Similar documents
Posterior Referencing. Surgical Technique

PERIPROSTHETIC IMPLANTS

Zimmer Natural Nail System. Cephalomedullary Nail Surgical Technique STANDARD

M/DN Femoral Interlocking & Recon Nail Intramedullary Fixation Surgical Technique

How To Use A Phoenix Retrograde Femoral Nail

Zimmer Small Fragment Universal Locking System. Surgical Technique

TRIGEN TAN and FAN Intramedullary Nails

Zimmer Periarticular Proximal Tibial Locking Plate

Surgical technique. End Cap for TEN. For axial stabilization and simultaneous protection of soft tissue.

Expert LFN. Lateral Femoral Nail.

High-Flex Solutions for the MIS Era. Zimmer Unicompartmental High Flex Knee System

How To Fix A Radial Head Plate

VERSYS HERITAGE CDH HIP PROSTHESIS. Surgical Technique for CDH Hip Arthroplasty

Zimmer MOST Options System

NCB Distal Femur System. Surgical Technique

Zimmer Periarticular Elbow Locking Plate System

V-TEK IVP System 2.7 System 4.0

Aesculap Veterinary Orthopaedics. Targon VET Interlocking Nail

Zimmer PSI Knee System For Use with Persona The Personalized Knee System Surgical Technique

Zimmer M/L Taper Hip Prosthesis. Surgical Technique

Expert ALFN. Adolescent Lateral Femoral Nail.

TRIGEN INTERTAN Intertrochanteric Antegrade Nail Surgical Technique. Table of Contents

Zimmer NexGen LCCK. Surgical Technique for use with LCCK 4-in-1 Instrumentation. Contact your Zimmer representative or visit us at

The information contained in this document is intended for healthcare professionals only.

Technique Guide. Titanium Trochanteric Fixation Nail System. For intramedullary fixation of proximal femur fractures.

DRAFT. Triathlon TS Knee System. Surgical Protocol. Version 1

Technique Guide. Orthopaedic Cable System. Cerclage solutions for general surgery.

Technique Guide. DHS/DCS Dynamic Hip and Condylar Screw System. Designed to provide stable internal fixation.

Trabecular Metal Femoral Component. Surgical Technique

Zimmer FuZion Instruments. Surgical Technique (Beta Version)

TransFx External Fixation System Large and Intermediate Surgical Technique

OptiLock Periarticular Plating System For Proximal Tibial Fractures. Pre-Launch Surgical Technique

NCB Periprosthetic Femur Plate System. Surgical Technique

Versa-Fx II Femoral Fixation System Surgical Techniques

TFN Titanium Trochanteric Fixation Nail System. For intramedullary fixation of proximal femur fractures.

Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery.

Zimmer PSI Knee System For Use with the NexGen Complete Knee System Surgical Technique

TABLE OF CONTENTS. Surgical Technique 2. Indications 4. Product Information Patient Positioning and Approach 2

Technique Guide. VersiTomic. Michael A. Rauh, MD. Anterior Cruciate Ligament Reconstruction

Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology. Surgical Technique

INTUITION INSTRUMENTS SURGICAL TECHNIQUE

BONE PRESERVATION STEM

Restoration Modular. Revision Hip System Surgical Protocol

Spinal Arthrodesis Group Exercises

Restoration Modular Cone Body/Conical Distal Stem Femoral Components Using the Restoration Modular Instrument System Surgical Technique

The information contained in this document is intended for healthcare professionals only.

Cable System. For Orthopaedic Trauma Surgery.

Surgical Technique and Reference Guide

S-ROM NOILES. This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

Implant Extraction Guide Module One & Two

Lentur Cable System. Surgical Technique

NEXGEN COMPLETE KNEE SOLUTION. Epicondylar Instrumentation Surgical Technique For Legacy Posterior Stabilized Knees

Anatomic Percutaneous Ankle Reconstruction of Lateral Ligaments (A Percutaneous Anti ROLL)

Exeter. Surgical Technique. V40 Stem Cement-in-Cement. Orthopaedics

SALVATION. Fusion Bolts and Beams SURGICAL TECHNIQUE

ACL Reconstruction with Bone-Tendon-Bone Transplants Using the ENDOBUTTON CL BTB Fixation System

INTRODUCTION Cerclage Cable Vs. Monofilament Wire

Expert TN. Tibial Nail.

NexGen Complete Knee Solution Intramedullary Instrumentation Surgical Technique

Anterior Lumbar Interbody Fusion (ALIF). Instrument set supports placement of ALIF spacers using anterior or anterolateral approach.

Expert HAN. Expert Hindfoot Arthrodesis Nail.

Knotilus TM. Anchor Instability Repair. Technique Guide

4052 Slimplicity Tech final_layout 1 6/29/15 3:29 PM Page 2 Surgical Technique

VariAx Distal Radius Locking Plate System. Anatomical & Universal Volar Plates Dorsal Plates Fragment Specific Plates

Zimmer Segmental System. Distal Femoral Surgical Technique

Zimmer NexGen CR-Flex and LPS-Flex Knees. Surgical Technique with Posterior Referencing Instrumentation

Scorpio NRG CR & PS. Single Radius Primary Knee System Surgical Protocol. Anterior Referencing

Titanium Wire with Barb and Needle. For canthal tendon procedures.

Achilles Tendon Repair, Operative Technique

Double Bone Plug Meniscus Reconstruction Surgical Technique

Minimally Invasive Hip Replacement through the Direct Lateral Approach

Anteromedial ACL Reconstruction Surgical Technique for Soft Tissue Grafts

Rodding Surgery. 804 W. Diamond Ave., Ste. 210 Gaithersburg, MD (800) (301)

Technique Guide. 3.5 mm and 4.5 mm Curved Locking Compression Plates (LCP). For minimally invasive osteosynthesis.

Technique Guide. 2.7 mm/3.5 mm Variable Angle LCP Ankle Trauma System. Part of the Synthes variable angle locking compression plate (VA-LCP) system.

Technique Guide. 4.5 mm LCP Proximal Femur Plates. Part of the Synthes Periarticular LCP Plating System.

CLAW II. Polyaxial Compression Plating System SURGIC A L T ECHNIQUE

Features and Benefits at a Glance Standard Features ExclusiveTable Maneuverability Superior Imaging High Stability Ordering Information

Zimmer Gender Solutions NexGen High-Flex Implants

ACTIV ANKLE DISTAL AND DIAPHYSEAL FIBULA INNOVATION MEANS MOTION

Zimmer Persona Adverse Events Reported to FDA Through 3/27/2015

Fracture Care Coding September 28, 2011

Foot and Ankle Technique Guide Proximal Inter-Phalangeal (PIP) Fusion

Deflectable & Steerable Catheter Handbook

Aesculap Orthopaedics BiCONTACT

Technique Guide. Reamer/Irrigator/Aspirator (RIA). For intramedullary reaming and bone harvesting.

ANTERIOR LUMBAR INTERBODY FUSION (ALIF) Basic Anatomical Landmarks: Anterior Lumbar Spine

iassist Knee Surgical Technique 2-Pod Version Instruments

Introduction. I. Objectives. II. Introduction. A. To become familiar with the terms of direction and location.

Primary V40 Surgical Protocol. Exeter. total hip system

Arthroscopic Shoulder Instability Repair Using the SUTUREFIX ULTRA Suture Anchor and SUTUREFIX ULTRA Instrumentation System

Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology

Malleolar fractures Anna Ekman, Lena Brauer

MINI FRAGMENT SYSTEM. Instruments and implants for 1.5 mm, 2.0 mm, and 2.4 mm plate fixation PRODUCT OVERVIEW

Technique Guide. Large Fragment LCP Instrument and Implant Set. Part of the Synthes locking compression plate (LCP) system.

METAL HEMI. Great Toe Implant SURGICAL TECHNIQUE

MatrixNEURO CMF Matrix

P REPLACEMENT SURGERY

Introduction to the Bertram Hip Spacer

Transcription:

Patient Fit is Now an Option Zimmer Natural Nail System

Taking IM nailing to the next level The Zimmer Natural Nail System is a next generation system of intramedullary nails that is designed to help restore the shape of the fractured long bone to its natural, pre-injured state. The comprehensive system comprises intuitive instrumentation and a large choice of anatomical implants. The nails feature versatile locking hole options including the new Zimmer StabiliZe Technology. With the Zimmer Natural Nail System surgeons have the opportunity to achieve stable internal fixation on a wide range of patients and fracture patterns as well as to accommodate their surgical preferences. A wide range of anatomical implant shapes and sizes provide a precise and anatomical fit Advanced Zimmer StabiliZe Technology creates robust nail screw bone construct Intuitive instruments allow simplified and repeatable procedures

Anatomical fit Bows in femoral nails correspond to nail length, reflecting the anterior femoral bow relative to patient height Nail tips are designed to help the passage of the nail through the medullary canal Left and right versions available for antegrade femur and cephalomedullary nails Fluted design moderates stiffness and facilitates easier nail placement Enhanced fixation, even in poor bone quality Exclusive Zimmer StabiliZe Technology links the nail to interlocking screws to create an advanced construct. This interface helps secure the nail, which aids in controlling rotation, alignment and length Deep screw threads provide for optimized bone purchase Screw hole placement is optimized to allow long screws to be placed in the very distal or proximal section of the bone, while protecting joint surfaces

Intuitive instruments encourage consistency and accuracy Specific color coding system for each nail type, instrument size, drill and screw diameter makes use of the system intuitive Ergonomic handles for control during implant placement Flexible and curved instruments which facilitate the clinical approach Simplified technique requires no extra steps for Zimmer StabiliZe Technology freehand screws

Cephalomedullary Nails Long Nail Versatile distal hole options with Zimmer StabiliZe Technology Anatomic anterior bows varying with the nail length 30 34 cm 1.3 m 36 40 cm 1.4 m 42 48 cm 1.5 m 4 proximal lateralization angle and 15 anteversion Spiral flutes moderate stiffness and facilitate nail placement Anterior bevel on tip Left and right versions available to fit the medullary canal 15.5 mm proximal head minimizes the diameter of the required opening hole Short Nail Anterior bow radius 1.3 m Clothes pin tip to help reduce stress 4 proximal lateralization angle and 15 anteversion Left and right versions available to fit the medullary canal 15.5 mm proximal head minimizes the diameter of the required opening hole

Tibial Nails Versatile hole options with the Zimmer StabiliZe Technology to treat a wide range of injuries, including very proximal and very distal fractures Guides allow for nailing in both extension and flexion Specific screw trajectories to help capture best quality bone (first screw descends with joint, second screw ascends towards joint) Very proximal Herzog bend (10 ) to help facilitate nail entry Shaft cross section Distal bow ~2 to help facilitate nail entry and distal fit 90-90 distal construct to provide rotational stability 4 proximal holes

Antegrade Femoral Nails Versatile hole options with the Zimmer StabiliZe Technology to treat a wide range of injuries, including very proximal and very distal fractures Recon or interlocking options 15 of anteversion for recon screws Anatomic anterior bows varying with the nail length 24 34 cm 1.3 m 36 42 cm 1.4 m 44 48 cm 1.5 m Specific nails for different entry points (greater trochanter and piriformis fossa) Greater Trochanter nail has 3.1 lateralization Retrograde Femoral Nails Versatile hole options with the Zimmer StabiliZe Technology to treat a wide range of injuries, including distal femur fractures Standard transverse or advanced oblique locking options oblique holes target bone in posterior condyles Anatomic anterior bow of 1275mm (50 inches) for all lengths Short and long nails available Distal bend of 5 to help facilitate nail insertion and distal fit Specific screw trajectories proximally for short and long nails Short: 3 proximal screw holes - M/L Hole, M/L Slot, M/L Hole Long: 2 proximal screw holes - A/P Hole, A/P Slot

This documentation is intended exclusively for physicians and is not intended for laypersons. Information on the products and procedures contained in this document is of a general nature and does not represent and does not constitute medical advice or recommendations. Because this information does not purport to constitute any diagnostic or therapeutic statement with regard to any individual medical case, each patient must be examined and advised individually, and this document does not replace the need for such examination and/or advice in whole or in part. Please refer to the package inserts for important product information, including, but not limited to, contraindications, warnings, precautions, and adverse effects. Contact your Zimmer representative or visit us at www.zimmer.com +H124972490001001/$101025R1K10K 97-2490-001-00 Rev. 1 1009-T14 2.5ML Printed in USA 2010 Zimmer, Inc.