User's Guide. Model W 3-in-1 Switching DC Power Supply



Similar documents
EzFlex Combustible Gas Leak Detector Model EZ40

Dual Laser InfraRed (IR) Thermometer

Dual Laser InfraRed (IR) Thermometer with Color Alert

Dual Laser InfraRed (IR) Thermometer

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Ground Resistance Clamp-On Tester

User's Guide Integrating Sound Level Datalogger Model

ExStik TM ph Waterproof Meters

User's Manual. Model Laser Photo / Contact Tachometer. Introduction

HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply

High Temperature InfraRed Thermometer with Laser Pointer

User's Guide. Integrating Sound Level Datalogger. Model Introduction

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

User's Guide. Digital Viscotesters. Model High Range (0.3 to 4000 dpas) Model Low Range (1.5 to 330 mpas) Introduction

APG-XT APG-HPD. Operating Manual. Internal APG (Analog Programming) Interface for XT/HPD Series Programmable DC Power Supply

INSTALLER S & OWNER S MANUAL

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Part I - Installation

Advantium 2 Plus Alarm

DC POWER SUPPLY ALIMENTATION C.C.

User Guide. 4 wire Earth Resistance Tester Model GRT300

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

12 Volt 30 Amp Digital Solar Charge Controller

12-Volt 10-Amp Regulated Power Supply

Remote Alarm Monitoring System

How To Use A Cdm250 Digital Multimeter

Seven function digital multimeter

Installation and Operation Guide for PD4100 Series Power Control Centers

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

±15 V Current-Limited Power Supply

Instruction Manual. This manual covers models: 8-125E 60-18E 20-50E 80-13E 33-33E 150-7E 40-25E E 50-20E E

Light Meter (Foot Candles)

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

Water Leak Detection System

Model SRMD Setra Remote Monitoring Display

16/32 Channel 1U Rack Mount CCTV Power Supply

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

INSTRUCTION MANUAL DTH Fax: (503)

OWNERS MANUAL FOR CORDLESS INFLATOR AIR260

OWNER'S MANUAL. AtlasSound.com PA601 COMMERCIAL AMPLIFIER. PA601 Commercial Amplifier. Power. Master

Installation and Operation Guide for PD4000 Series Power Control Center

Alarm Clock USER GUIDE

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Owner s Manual channel amplifier

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

DVI+HDCP 4x1 Switcher User Manual

Ground Resistance Clamp On Tester

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

P O W E R S U P P L Y M A N U A L

INSTRUCTIONS FOR MAGNUM DS TRIP UNIT TESTING USING TEST KIT SYLES 140D481G02R, 140D481G02RR, 140D481G03 AND 140D481G04

AutoRanging Digital MultiMeter

Manual. Solar Fountain Mobile Phone Charger

How To Use A Power Supply Unit (Upu)

User s Manual Before using the inverter, you need to read and save the safety instructions.

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

INSTRUCTION MANUAL MODEL PCD-88

1.44 kw Programmable DC Power Supplies XLN Series

About this Manual. Support for Your Product

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

SURROUND MASTER. User Manual 1.0. English. Copyright 2012 Involve Audio

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

Wireless Indoor/ Outdoor Thermometer

3000W Power Inverter

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

User Guide. Model Insulation Tester / Megohmmeter

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

User s Manual AURORA 1.2K/2.2K

Mini-led spotlight with magnetic base

4-Channel Thermometer / Datalogger

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

, User s Manual

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Agilent E3633A and E3634A DC Power Supplies

I STAR COMPUTER CO., LTD

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Liquid Carbon Balanced Transportable Headphone Amplifier. Cavalli audio. Copyright Cavalli Audio, LLC All Rights Reserved

i410/i1010 AC/DC Current Clamp

MCR1900 Media Converter 19-Slot Chassis

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

PERF10 Rubidium Atomic Clock

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Agilent 87421A/87422A Power Supply

CABLE MODEM QUICK START

User Manual for CH-PFC76810

LCD5500Z / PKP-LCD v3.x Installation Instructions

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

F2400 FOM II Series Fiber Optic Modem Technical Manual

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

Transcription:

User's Guide Model 382260 80W 3-in-1 Switching DC Power Supply

Introduction Congratulations on your purchase of the Extech 80W 3-in-1 Switching DC Power Supply. The Model 382260 has three output ranges that perform like 3 power supplies in one. It can be used for many applications including bench testing, field service, hobby and telecommunication equipment use. This power supply is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Safety This manual contains important safety and operation instructions for correct use of the power supply. Read through the manual and pay special attention to the markings and labels of this unit and equipment to be connected. Pay special attention to these two types of notices used in this manual WARNING : Failure to observe this warning may cause injury to persons and damage to power supply or connected equipment. CAUTION : Failure to observe this warning may result in damage to equipment and Improper functioning of the power supply. WARNING : 1. Do not use this power supply near water. 2. Do not operate or touch this power supply with wet hands. 3. Do not open the casing of the power supply when it is connected to ac mains. 4. Refer all servicing to qualified service personnel only. 5. Before replacing the AC fuse find out and clear up the cause first. 6. Replace the AC fuse with the same type and rating as the original fuse. CAUTION : 1. Use a grounded 3 pin AC source. 2. This unit is for indoor use only. 3. Do not operate or place this unit in a humid, dusty, in direct sunlight location or near any heat source. 4. Before plugging into local AC mains, check with the rating label at the back of the unit. 5. Do not block any ventilation openings of the unit. 6. This unit must be used within the specified rating, regular excessive continuous loading may cause damage to the power supply. 7. The gauge size of input power cable must be at least 0.75mmsq and the total length of power cable must not exceed 3m. 8. Input Fuse Recommended: T3AL250V (3A Time-Lag) 2

Power Supply Description 1. Power On/Off switch 2. Output terminals 3. UVL adjustment screw 4. Current adjustment 5. Voltage adjustment 6. Upper Voltage Limit button 7. Preview button 8. Range selector 9. Output On/Off button 10. UVL indicator 11. Constant Voltage indicator 12. Constant Current indicator 13. Overvoltage or Temperature alarm 14. Slave indicator 15. LED Voltage Display 16. LED Current Display 17. Master/Slave switch 18. Master/Slave control terminals 19. Remote Sensing terminals 20. Rear Output terminals 21. AC power socket 3

Stand Alone Operation 1. Set the Master/Slave switch located on the back of the unit to the Master position. 2. Without any load attached, use the POWER button to switch on the power supply and the LED indicator will light. There should not be any reading on the voltmeter and ammeter. 3. Press the Output On/Off button and its green LED will light up, the voltmeter will display the previously set output voltage. Use the voltage control knob to adjust the voltage to the desired level. 4. Use the Output On/Off button to turn off the output. Note: The output will automatically shut off when one of the other voltage/current range selection buttons is pushed. This is to prevent damage to a connected load if the voltage/current values are set too high. 5. Press and Hold the Preview button to display the previously set voltage and current limiting values. With this button held down, you can set the current limiting value without connecting to a load or shorting the output terminals. Note: The Output button must be in the Off position. Setting the Upper Voltage Limit (UVL) Value The Upper Voltage Limit Value is an added protection for voltage sensitive loads. When the output voltage exceeds the set UVL, the output terminal will automatically shut off and the ALM LED will light. Note: Only one UVL value can be set for all three ranges. 1. Press the UVL/Voltage and insert a small screwdriver into the UVL adjustment screw. 2. Turn clockwise to increase the voltage limit and counter-clockwise to decrease the UVL value. Remote Sensing Operation When the output current is high or the load connection is long, there is a voltage drop across the connecting cable. This results in a difference between the voltage at the output terminal and load point. By making an extra connection using the Remote Sensing Terminal to the load point, the reading at the output terminal and load point is the same. Caution: Observe correct polarity and never short the Remote Sensing terminal 1. Connect the load to the power supply. 2. Connect the load to the Remote Sensing Terminal. Note: Always disconnect the Remote Sensing terminal connections first. 4

Master/Slave Operation Two or more Model 382260 Power Supplies can be connected in parallel to increase output current to the sum of the connected supplies. In this mode of operation, the Master power supply will control all of the voltage and current settings of the Slave units. 1. Set all of the power supplies to the same upper voltage limit (UVL) and voltage/current range. 2. Set the voltage and current limit of all of the slaves to maximum values. 3. Switch off all of the power supplies. 4. Set the Master/Slave switch to the Slave position on all of the Slave units. 5. Connect the power supplies together using the Master/Slave control circuit on the back of the power supplies. Note: For proper performance all connecting cables and output cables should be the same gauge and length. 6. Using either the output terminals on the front or back of the units, connect the output cables in parallel to the load. 7. Switch on the Master unit first and set to the desired voltage. 8. Switch on the slave units and the Slave Indicator LED will light to confirm correct connection. 9. All output voltages and currents are now controlled by the Master unit. 5

Specifications Display Dual 4-digit LED Display Accuracy ±(1% reading + 15 counts) Voltage Output, DC 0.10 to 16.40V 0.10 to 27.60V 0.10 to 36.80 Current Output, DC 0.100 to 5.100A 0.100 to 3.100A 0.1 to 2.300A Ripple and Noise <30mVp-p Line Regulation < 4mV/<10mA Load Regulation < 20mV/<10mA Efficiency >75% Power Factor >0.9 Operating %RH 10 to 80% RH Altitude 2000m Installation Category CAT 2 Pollution degree 2 Power 90 to 264VAC (47 to 63Hz) Supply voltage fluctuation ± 10% of stated operating voltage Dimensions 13 x 5 x 2" (330 x 127 x 53.5mm) (WxHxD) Weight 4.2lbs. (1.9 kg) Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies to sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our website www.extech.com for contact information. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. 6

Trouble Shooting PROBLEM INDICATIONS POSSIBLE CAUSES SUGGESTED SOLUTIONS Panel display, LED Indicators not on Power supply not working No DC output power Voltage meter reading grossly inaccurate Ampere meter reading grossly inaccurate The activated (auto- cross over ) current limiting value is different from the preset cc value Voltage meter zero indication. ALM (13) Alarm led on CC (12) led on Actual output voltage is grossly different from the meter read out In CV mode, the actual current measured is grossly different from the Amp meter reading All indicators and display are normal, only CC mode has the problem A. AC power input not connected B. AC input fuse blown A. Output on off button not on. B. UVL (10 ) protection triggered C. OTP protection triggered D. Output short circuit A. Volt meter shows not the output voltage. B. Possible misalignment in voltmeter calibration Possible misalignment in calibration. For stand alone unit, Master & Slave Switch (17) in wrong position (Slave). Wrong setting or connection in Master & Slave or s e t u p procedure. A. Check AC power connection, B. Contact factory A. Check output LED (9) is on or not, push (9) to on. B. Check UVL set voltage by pushing (6), re-set UVL to applicable limit. C. Check vent holes at top and bottom is clear, ambient temperature too high D. Check and undo short circuit of output connection. A. Check the LED indicator of UVL on the top right hand side of the Volt meter, if it lights up then the volt meter only shows the set UVL value. Push (6) to go back to output voltage. B. Contact factory Contact factory Check the Master & Slave switch (17) correct position. Use stand alone mode to check power supply separately without any connection to slave units. Follow the procedure carefully and make sure there is only one Master unit. Calibration and Repair Services Extech offers repair and calibration services for the products we sell. Extech also provides NIST certification for most products. Call the Customer Service Department for information on calibration services available for this product. Extech recommends that annual calibrations be performed to verify meter performance and accuracy. 7

Support line (781) 890-7440 Technical Support: Extension 200; E-mail: support@extech.com Repair & Returns: Extension 210; E-mail: repair@extech.com Product specifications subject to change without notice For the latest version of this User s Guide, Software updates, and other up-to-the-minute product information, visit our website: www.extech.com Extech Instruments Corporation, 285 Bear Hill Rd., Waltham, MA 02451 Copyright 2007 Extech Instruments Corporation (a FLIR company) All rights reserved including the right of reproduction in whole or in part in any form. 8