SIRAX SI 815 Passive DC Signal Isolator

Similar documents
SINEAX U553 Transducer for AC Voltage

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Digital input modules

Analog signal converters CC-E I/I Current / current isolators

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

DS 600. A contact free flux gate based current measurement sensor 600A rms

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Inductive sensor NI10-M18-Y1X-H1141

Quick Connect. quick - simple - efficient.

Safety technique. Emergency stop module BO 5988 safemaster

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

3DLevelScanner II TECHNICAL DATA SHEET

2002 IS Catalog. Page

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Series 8146/5-V37 and Series 8150/5-V37

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Rosemount 333 HART Tri-Loop

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

MINI MCR-SL-R-UI(-SP)

Actuator-Sensor-Interface

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

FieldIT Head mounted Temperature Transmitter TF02/TF02-Ex

Three-phase monitoring relay CM-PFE

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Electronic overload relay EF19 and EF45

Rosemount 333 HART Tri-Loop

NX safety stand-alone

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Duct Humidity Transmitter

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Plug and Socket Devices CES 63 A Series 8579

Power Supplies 3. SDN-P DIN Rail Series

Technical Data. Dimensions

Electronic overload relay EF65, EF96 and EF146

3500/62 Process Variable Monitor

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Flow switches Series AD/VH

TX OPEN RS232/485 module

Measuring transducers for all electrical AC-variables

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Current and voltage measuring relays

Vario-Series Accessories

T0118 T2118 T3118. Instruction Manual

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Contact expansion modules

Relés e Contatores de Estado Sólido SIRIUS

Disturbance Recoder SPCR 8C27. Product Guide

Voltage Regulator SPAU 341 C. Product Guide

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Pluggable interface relays CR-P Pcb relays

38 Series - Relay interface modules A

Digital display DA 48

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

7 Lighting Technology

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Foxboro Evo Process Automation System

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Redundancy Module QUINT-DIODE/40

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

2.06. Version. Kinglong New Energy Technology Co.Ltd. Sunteams 1500 Sunteams Sunteams 4000 Sunteams 5000

5SV Residual Current Protective Devices

How To Use A Flowmeter

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

EGSTON Standard E2xFxWx 12W

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Relative pressure transmitter type 520

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

38 Series - Relay interface modules A

Modular I/O System Analog and Digital Interface Modules

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Test equipment for temperature and its reduction

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

RY2 miniature industrial relays

Transcription:

with power supply transfer and without separate power supply connection, versions available for FSK, Ex and non-ex versions 002 II () G Application The signal isolator SIRAX SI 85 (Fig. ) serves to electrically insulate the 4 20 ma input circuit of a 2-wire transmitter. It performs two tasks at the same time. Firstly it provides electrical insulation and secondly it conducts the power supply needed for measurement to the 2-wire transmitter without injecting into the circuit itself. Thus the isolator does not require an power supply connection itself. Some versions of the SIRAX SI 85 are. They are used in conjunction with intelligent 2-wire transmitters which are capable of dialogue and operation according to the FSK principle and the HART or user-specific protocol. The series also includes intrinsically safe versions [EEx ia] IIC with an intrinsically safe measurement/supply circuit. This operate in conjunction with intrinsically safe 2-wire transmitters located in hazardous areas. The signal isolator is supplied with two transmitter channels. The SIRAX SI 85 fulfils all the important requirements and regulations concerning electromagnetic compatibility EMC and Safe Isolation (IEC 00 resp. EN 6 00). It was developed and is manufactured and tested in strict accordance with the quality assurance standard ISO 900. Production QA is also certified according to guideline 94/9/EG. Fig.. Plug-in module SIRAX SI 85 for plugging onto backplane BP 902. Features / Benefits SIRAX SI 85 plugs onto backplane (mechanically latched by fasteners), all electrical connections made to the backplane and not to the SIRAX SI 85 / Thus no wiring when replacing devices Electrically insulated output and input signal / Prevents the transfer of interference voltages and currents, overcomes signal connection problems Output signal Input signal = 4 20 ma Transmission of the power supply for 2-wire transmitters / Simple low-cost instrumentation No power supply required / Saves having to run and connect power supply leads Suitable for transmitting analog 4 20 ma signals frequencymodulated by digital signal (FSK communication) / Enables operationg in conjunction with an intelligent 2-wire transmitter designed for FSK and a HART or company-specific protocol Intrinsically safe version [EEx ia] IIC (see Table 2 Data on explosion protection ) FSK = Frequency Shift Keying Camille Bauer Data sheet SI 85-6 Le 09.07

Layout and mode of operation The description below refers to a SIRAX SI 85 designed for FSK communication. The signal isolator comprises a series regulator LR, a DC chopper Z, an isolating stage T, a rectifier G, an oscillator O and a FSK converter W (see Fig. 2). E signifies the input signal and A the output signal. 2-wire transducer X ma 4...20 ma A G Fig. 2. Block diagram. T FSK Digital signal W O Z Analogue signal Power supply LR E Receiver 4...20 ma Hand-held terminal Power pack Power supply Input signal E to approx. 22 V and the chopper Z converts it to an AC signal. The latter can pass the transformer in the isolating stage and is then rectified again and smoothed to obtain the impressed analog 4 20 ma output signal The chopper is controlled by the oscillator which draws its power supply from the input signal. The FSK converter in the bypass provides the electrical insulation and transmits the frequency-modulated digital signal which is superimposed on the analog 4 20 ma signal of the intelligent 2-wire transmitter and used to set its parameters and for requesting the transfer of measurements or status data. While the digital signal is transferred by the SIRAX SI 85 in both directions to support a dialogue with the 2-wire transmitter, the analog signal and the power supply only flow in one direction. The analog signal, however, passes the signal isolator from the transmitter side to the supply/receiver side and the power supply in the opposite direction. The power supply is provided either by an active receiver (display, recorder, limit monitor and/or controller with integrated 4 20 ma measurement/supply module, PLC, PLS etc.) or a power supply unit in series with a passive receiver (see Fig. 2). Technical data Input signal E (Input circuit between signal isolator and power pack) DC current signal I E Voltage U E Overload capacity Output signal A 4 20 ma 2 30 V DC 50 ma continuous (Output circuit between signal isolator and 2-wire transmitter) DC current signal I A 4 20 ma Voltage U A (for I E = 20 ma and U E = 22 V) > 9.3 V with standard (non-ex) version, > 8.5 V with standard (non-ex) version, > 4.3 V with Ex versions, > 3.3 V with Ex versions, Voltage drop U V = U E U A (at U E ) 2 22 V) < 2.7 V with standard (non-ex) version, < 3.5 V with standard (non-ex) version, < 7.7 V with Ex versions, < 8.7 V with Ex versions, Residual ripple Time constant Accuracy data < 20 mv ss (20 khz) Approx. 5 ms Error < ± 0.2% (Reference value 20 ma of output signal, including typical linearity error < ± 0.%) Reference conditions DC current signal I E Ambient temperature Voltage U E 4 20 ma DC 23 C, ± K 2 30 V DC Input and output in this case refer to the direction of power supply flow. Additional error Temperature coefficient < 50 ppm/k 2 Data sheet SI 85-6 Le 09.07 Camille Bauer

Installation data Mechanical design Signal isolator in housing B7 for plugging onto backplane BP 902. Refer to Section Dimensional drawing for dimensions Material of housing Lexan 940 (polycarbonate). Flammability class V-0 acc. to UL 94, self-extinguishing, non-dripping, free of halogen Designation SIRAX SI 95 Mounting position Any Electrical connections 96-pin connector acc. to DIN 4 62, pattern C Layout see Section Electrical connections Coding Signal isolator supplied already coded. The rack is coded by the user by fitting the coding inserts supplied Weight approx. 70 g With 2 isolation and transmission channels, without FSK communication approx. 90 g with FSK communication Regulations Electromagnetic compatibility The standards DIN EN 50 08-2 and DIN EN 50 082-2 are observed Intrinsically safe Acc. to DIN EN 50 020 996-04 Electrical design Acc. to IEC 00 resp. EN 6 00 Protection (acc. to IEC 529 resp. EN 60 529) Housing IP 40 Terminals IP 00 Rated insulation voltage Contamination level 2 Overvoltage category acc. to IEC 664 Test voltage 253 V AC II 2.3 kv, 50 Hz, min. Inputs versus outputs Inputs versus inputs Outputs versus outputs Impulse withstand voltage 4.25 kv,.2/50 µs Inputs versus outputs Inputs versus inputs Outputs versus outputs Ambient conditions Climatic rating Climate class 3Z acc. to VDI/VDE 3540 Commissioning temperature 0 to 40 C Operating temperature 25 to 40 C, Ex 20 to 40 C Storage temperature 40 to 70 C Annual mean relative humidity 75% Altitude Indoor use statement! 2000 m max. Table 2 Ordering informations Description *Blocking code No-go with blocking code Article No./ Feature SIRAX SI 85- Order Code 85-xxxx 85 Features, Selection. Mechanical design Housing B7 (for plugging onto backplane BP 902, 6 see data sheets BP 902) 2. Version Standard (Non-Ex) [EEx ia] IIC, outputs intrinsically safe 2 3. Number of isolation and transmission channels 2 channels (interface) 2 4. Field communication protocol Without FSK communication 0 With FSK communication, 2 channels 2 Possible special versions, e.g. increased climatic rating on inquiry Camille Bauer Data sheet SI 85-6 Le 09.07 3

Electrical connections SIRAX SI 85 Front SIRAX SI 85 Rear Fastener c b a A B C 2 4 6 8 A 3 A2 5 7 Camille Bauer AG CH-560 Wohlen Switzerland D E F G 4 H 20 I GOSSEN METRAWATT CAMILLE BAUER SIRAX SI 85 K L M 26 27 28 29 30 3 32 E E2 Plug-in module SIRAX SI 85 c27 a26 a c2 a29 a28 a3 c4 Backplane Connecting allocation see Operating Instructions of backplanes E A E2 A2 HHT HHT E = Input E2 = Input 2 A = Output A2 = Output 2 HHT = Hand-held-terminal SIRAX SI 85-62., Standard-(non-Ex) version and SIRAX SI 85-622., Ex version (output signals A and A2 «intrinsically safe») 4 Data sheet SI 85-6 Le 09.07 Camille Bauer

Table 2 Data on explosion protection II () G Order Code Type of protection 85-622.. [EEx ia] IIC U o = 23. V I o = 00 ma P o = 580 mw Electrical data acc. to Certificates Output Input Linear characteristic IIC IIB L o 4 mh 5 mh C o 40 nf.02 µf U m = 253 V AC resp. 25 V DC Type Examination Certificate PTB 97 ATEX 20 Mounting location Outside the hazardous area Table 3 Accessories and spare parts Description Order No. Coding comb with 2 sets of codes (for coding the backplane BP 902) 07 97 Operating Instructions SI 85-6 B d-f-e 08 242 Standard accessories Operating Instructions for SIRAX SI 85 in three languages German, French, English Coding comb with 2 sets of codes Type Examination Certificate (only for instruments in type of protection Intrinsically safe ) Dimensional drawing 50.7 0 03.3 23.5 3.5 35.7 5 8 0 0.5 Fig. 3. SIRAX SI 85 in housing B7. Rely on us. Camille Bauer AG Aargauerstrasse 7 CH-560 Wohlen / Switzerland Phone 4 56 68 2 Fax 4 56 68 35 35 e-mail info@camillebauer.com www.camillebauer.com Subject to change without notice Edition 09.07 Data sheet SI 85-6 Le