Compliant Dental Local Decontamination Units in Scotland (Primary Care)



Similar documents
Project Management. Advice on the provision of Local Decontamination Units (LDUs) Decontamination Services

National Decontamination Guidance on Loan Medical Devices (Reusable): Roles & Responsibilities GUID 5002

Sterilization of Dental Instruments Dental Clinical Guidance

The design planning implications of HTM 01-05: decontamination in primary care dental practices

Management of infection control in dental practice

Electrical Safety Policy

Guide to Regulatory Requirements for the Procurement of Human Tissues and Cells intended for Human Application

Choice Framework for local Policy and Procedures Management and decontamination of surgical instruments (medical devices) used in acute care.

References for DH HTM 01-05: Decontamination in primary care dental practices.

Summary of the role and operation of NHS Research Management Offices in England

Safe management of healthcare waste

Health & Safety Policy and Procedure MEDICAL DEVICES IN DENTAL POLICY. Version: v1. Date approved: pending

We are the regulator: Our job is to check whether hospitals, care homes and care services are meeting essential standards.

LAB 37 Edition 3 June 2013

Policy Document Control Page

South West Lincolnshire NHS Clinical Commissioning Group Business Continuity Policy

How To Inspect A Blood Bank

We are the regulator: Our job is to check whether hospitals, care homes and care services are meeting essential standards.

Medical Devices/Equipment Management. Compliance with the HSE s Medical Devices and Equipment Management Standard. Guidance for Service Areas

(Samuel LAW Tat Hong) (COM CSSD NTWC)

ARRANGEMENTS FOR THE FUTURE SUPPLY AND REIMBURSEMENT OF GENERIC MEDICINES FOR NHS SCOTLAND. Consultation Document

ADVISORY COMMITTEE ON DANGEROUS PATHOGENS Annex M guidance

Australian/New Zealand Standard

Jonathan Wilson. Sector Manager (Health & Safety)

Information Governance in Dental Practices. Summary of findings from ICO reviews. September 2015

Update: Proposed Medical Device Regulation (MDR) & IVD Regulation (IVDR)

Example of a food company quality

Business continuity management policy

National Endoscopy Programme. Decontamination Standards for Flexible Endoscopes

We are the regulator: Our job is to check whether hospitals, care homes and care services are meeting essential standards.

CITY UNIVERSITY OF HONG KONG

Policy for the Management of Medical Devices (V5) Medical Device Procedures

Care service inspection report

We are the regulator: Our job is to check whether hospitals, care homes and care services are meeting essential standards.

ENVIRONMENTAL POLICY & MANAGEMENT SYSTEM GUIDE

STANDARD OPERATING PROCEDURE FOR RESEARCH. 2. Notification of Serious Breaches of Good Clinical Practice or Study Protocol

gsop Vendor Assessment SOP page 1 of 10

EXTENSION OF PERIODIC INSPECTION INTERVAL FOR LPG CYLINDERS

Company background and. portfolio overview

Consulted With Individual/Body Date Medical Devices Group August Carin Charlton, Director of. Estates and Facilities Management

Quality Management Standard BS EN ISO 9001:

We are the regulator: Our job is to check whether hospitals, care homes and care services are meeting essential standards.

Loan Set Management Principles between Suppliers/Manufacturers, Theatres = & Sterile Service Departments

West Midlands Police and Crime Commissioner Records Management Policy 1 Contents

BLOOM AND WAKE (ELECTRICAL CONTRACTORS) LIMITED QUALITY ASSURANCE MANUAL

Information Security: Business Assurance Guidelines

Waste Management Policy

ISO 9001:2015 Overview of the Revised International Standard

Decontamination Health Technical Memorandum 01-05: Decontamination in primary care dental practices

CCG: IG06: Records Management Policy and Strategy

QUALITY MANAGEMENT SYSTEM REQUIREMENTS General Requirements. Documentation Requirements. General. Quality Manual. Control of Documents

QSS 0: Products and Services without Bespoke Contracts.

BUSINESS CONTINUITY MANAGEMENT FRAMEWORK

West Highland College. Internal Audit 2014/15 Annual Report August 2015

Medical Equipment Management Policy. Procedure No. 114

Advertising of medicines: Guidance for providers offering medicinal treatment services

WASTE MANAGEMENT POLICY

ISO & ISO Legal Compliance Know Your Risk - Reduce your Risk"

BRC/IoP Global Standard

Dear Colleague. General Medical Services Contract 2013/14 Organisational Core Standard Payment - Payment Guidance. Summary

OH&S MANAGEMENT SYSTEM CHECKLIST - AS 4801:2001 (STATUS A = Acceptable; N = Not Acceptable; N/A = Not Applicable)

WORKPLACE HEALTH AND SAFETY AUDITING GUIDELINES

BUSINESS CONTINUITY MANAGEMENT POLICY

Public Records (Scotland) Act Healthcare Improvement Scotland and Scottish Health Council Assessment Report

Food Safety and Quality Management System

TRANSPORT FOR LONDON (TfL) LOW EMISSIONS CERTIFICATE (LEC) GUIDANCE NOTES FOR THE COMPANY AUDIT PROCESS. LEC (Company Audit) Guidance Notes

We are the regulator: Our job is to check whether hospitals, care homes and care services are meeting essential standards.

WEST LOTHIAN COUNCIL RECORDS MANAGEMENT POLICY. Data Label: Public

ASSESSMENT OF QUALITY RISK MANAGEMENT IMPLEMENTATION

Revision Date Author Description of change Jun13 Mark Benton Removed Admin. Manager from approval

JOB DESCRIPTION. Hours: 37.5 hours per week, worked Monday to Friday

TG TRANSITIONAL GUIDELINES FOR ISO/IEC :2015, ISO 9001:2015 and ISO 14001:2015 CERTIFICATION BODIES

/ Clinical Waste & Offensive Waste Disposal Procedures

Updates on CFPP and Standards

Records that all registered care services (except childminding) must keep and guidance on notification reporting

GUIDELINE NO. 22 REGULATORY AUDITS OF ENERGY BUSINESSES

ISO 9001:2008 Quality Management System Requirements (Third Revision)

PROPOSED UPDATED TEXT FOR WHO GOOD MANUFACTURING PRACTICES FOR PHARMACEUTICAL PRODUCTS: MAIN PRINCIPLES (JANUARY 2013)

BSI Unannounced Audits

Guidance for Industry: Starting Material Supplier Management

Contract Management Guideline

This is Document Schedule 5 Part 1 referred to in this Contract SCOTTISH MINISTERS REQUIREMENTS SCHEDULE 5 PART 1 QUALITY MANAGEMENT SYSTEM

INFECTION CONTROL SURVEYOR WORKSHEET

RECORDS MANAGEMENT FRAMEWORK

Inspecting Informing Improving. Hygiene code inspection report: South Western Ambulance Service NHS Trust

POLICY MANUAL BS EN ISO 9001:2008

Draft Service Level Agreement. for IT consultancy for advice, studies, software development and software maintenance Framework service contract

EA IAF/ILAC Guidance. on the Application of ISO/IEC 17020:1998

COMMISSION REGULATION (EU)

APES 325 Risk Management for Firms

Health Service Executive Standards and Recommended Practices for Dental Services in a Local Decontamination Unit (LDU)

ISO/IEC QUALITY MANUAL

Financial Services Guidance Note Outsourcing

BESTPRACTICE. HTM01-05 Q&A: You can now follow us on Twitter! We have launched our HTM01-05 questions and answers service on Twitter.

LSB Procurement Framework

Quality Policy. JRI Orthopaedics Limited

FMC Technologies Measurement Solutions Inc.

The post holder will be guided by general polices and regulations, but will need to establish the way in which these should be interpreted.

NHS ISLE OF WIGHT CLINICAL COMMISSIONING GROUP BUSINESS CONTINUITY POLICY

Transcription:

Compliant Dental Local Decontamination Units in Scotland (Primary Care) May 2013

Contents page 1.0 Scope and Purpose... 3 2.0 Technical requirements for an LDU reprocessing its own devices and/or procedure packs... 4 3.0 Technical requirements for an LDU reprocessing devices owned by another legal entity where the devices are located within the same building... 5 4.0 Outsourcing decontamination services to an LDU... 6 Appendix 1... 7 References... 9 This document is not a comprehensive guide to the legal and policy requirements for local decontamination facilities but sets out what Health Facilities Scotland considers to be the key essential requirements to assist practitioners to comply with the nationally agreed level of service. Practitioners remain responsible for ensuring their own compliance with relevant legislation and/or policy requirements. As such, practitioners should ensure that they are aware of, and take such steps as are necessary to comply with, relevant legislative and/or policy requirements. Version 1.0: May 2013 Page 2 of 10

1.0 Scope and Purpose This document clarifies the national requirements for compliant reprocessing of dental devices in Local Decontamination Units (LDUs) (Primary Care) with regard to The Medical Devices Regulations 2002 1 (as amended) (MDR), current best practice guidance and scope of activity. It brings together all elements and revises some elements of previous advice and requirements in relation to the operation of LDUs, including the Glennie Framework 6, clarifies the circumstances in which devices may be decontaminated by LDUs owned by a different legal entity, and explains how that can be done in a compliant manner. LDUs reprocess a wide range of instruments used in procedures which involve contact with low Creutzfeldt Jakob disease (CJD) transmission risk tissues in Primary Care dentistry. Any instruments which contact medium or high Creutzfeldt Jakob disease (CJD) transmission risk tissues should be single use. LDUs must not reprocess single use instruments as indicated in the MHRA alert 2. Also in Scotland endodontic files must be treated as single use in compliance with the Chief Medical Officer s letter CMO(2007)5 3. When considering compliance issues it can be useful to consider LDUs reprocessing devices as falling into two distinct categories namely:- Option 1: LDUs reprocessing instruments remaining within a single legal entity a) an onsite LDU; (the preferred option of Health Facilities Scotland is where the owner /manager of the LDU is only reprocessing its own instruments); b) an offsite LDU owned /managed by the same entity which owns the instruments. Option 2: LDUs reprocessing instruments for different legal entities; (e.g. an LDU owned by a NHS Board providing decontamination services to a practice owned by an independent contractor located within the same building), i.e. It is a requirement of The Scottish Government Health and Social Care Directorate that instruments are not transported outside of the building in which they are used, for decontamination by an LDU. An LDU model along the lines of Option 2 can however be managed in a legally compliant way provided there is: a) no transfer of ownership of any instruments; b) no placing on the market of any procedure packs (i.e. there is no broken chain of ownership in relation to the instruments being processed). These concepts are explained further in section 3.0. Note: Examples of a legal entity are an NHS Board or a dental practice owned by an independent contractor(s) or a corporate body. Appendix 1 gives a summary of LDU requirements for both options. In defining these technical requirements, the areas requiring consideration were: Version 1.0: May 2013 Page 3 of 10

The Medical Devices Regulations 2002 1 (MDR); Re-usable medical devices, their accessories and decontamination equipment (e.g. sterilizer washer disinfector) are classified as medical devices and regulated under MDR 1. Whilst LDUs may be operated for the benefit of third parties outside of the scope of the MDR 1, doing so requires the implementation of, and adherence to procedures and arrangements (possibly including contractual arrangements) which ensure there is no transfer of ownership or placing on the market of any devices. It is the responsibility of the owner/manager of the LDU to do so. The National Health Service (General Dental Services) (Scotland) Regulations 2010 4 came into force in July 2010. These require the contractor to provide proper, sufficient and safe: Premises; Equipment; Instruments; Procedures. Current best practice guidance for patient and staff safety; The compliance requirements are also based on best practice guidance 5-10, a review of current published literature and safety advice and legislation for patients, staff and the public 11-12 ; The appropriate technical requirements stated in the following sections (Sections 2.0, 3.0 and 4.0) must be adhered to, so that the risk associated with the transmission of infections via dental devices is minimised and to ensure that the quality and safety of reprocessed dental devices are fit for use on patients. The quality assurance requirements which require to be performed routinely by the user as a part of a Dental Practice Inspection by NHS Boards every 3 years. The definition of user can be found in note (d) on page 8. 2.0 Technical requirements for an LDU reprocessing its own devices and/or procedure packs This section relates to Option 1 (Section 1.0) above namely where the owner of the LDU is the same legal entity as the owner of all devices (and/or procedure packs) decontaminated/reprocessed within that facility. The LDU owner/manager is responsible for operating a compliant facility in accordance with all appropriate guidance and standards 5-10. LDU owners/managers also have responsibilities under general law (including consumer protection legislation) to ensure the safety of patients, staff and users 11-12. Table 1, Column 1 (Appendix 1) highlights the requirements for this LDU model. Version 1.0: May 2013 Page 4 of 10

When transporting devices, via a public road, outside the building in which the LDU is located, but within the same legal entity, there are additional requirements that include: Sterilized devices must be packed in a container to provide protection and to minimise contamination during transport and storage; The contaminated devices must be transported in compliance with the ADR -1(2013) European Agreement Concerning the International Carriage Of Dangerous Goods by Road 13. 3.0 Technical requirements for an LDU reprocessing devices owned by another legal entity where the devices are located within the same building This section relates to Option 2 (Section 1.0) above namely where the owner of the LDU is not the same legal entity as the owner of all devices (and/or procedure packs) decontaminated/reprocessed within that facility. The LDU owner/manager is responsible for the following: Ensuring that there is no breach of the MDR 1. Key to this is ensuring that the MDR do not apply. To achieve this, the LDU owner/manager must ensure no transfer of ownership of any devices or any placing on the market of any procedure packs i.e. all devices once decontaminated or processed must be returned to their original owner. Applying a system to ensure there is no mix up of different parties devices, and as such that no transfer of ownership of any devices or any placing on the market of any procedure packs occurs. Examples could include the use of an electronic tracking system, the use of colour coded cassettes (with different colours being used for different customers), or the use of different/distinct time slots, whereby devices provided for processing by different parties are processed at different times. The aim of each system being to ensure that the risk of devices transferring between parties is removed. Managing and operating compliant facilities in accordance with guidance/standards 5-10 ; Managing and operating facilities compliant with all legal requirements to ensure the safety of patients, staff and users 11-12 ; Demonstrating that a designated manager is responsible for developing and operating compliant decontamination practices and processes, and incorporating these practices and processes within a Service Level Agreement between it and its customers. Table 1, Column 2 (Appendix 1) highlights the requirements for this LDU model. Version 1.0: May 2013 Page 5 of 10

4.0 Outsourcing decontamination services to an LDU Ensuring the appropriate decontamination of devices is the responsibility of the practitioners or NHS Boards who own and use them. If a LDU of different legal entity is to be engaged to provide decontamination services, then a Service Level Agreement (SLA) should be put in place. Any SLA should include provision for the following as a minimum: A clear allocation of responsibilities and duties; An obligation on the owner/manager of the LDU to comply with the technical requirements as specified in Section 3.0 and highlighted in Table 1 Column 2 (Appendix 1); A right for the customer to undertake audits of the LDU which is reprocessing their devices; Practical requirements for wrapping, labelling and transporting devices, management of non-conforming products (e.g. damaged, wet, missing/lost, incorrect devices in the pack/tray/cassette), handling and investigations of complaints; Financial and liability issues. Although practices outsourcing their decontamination requirements do not physically undertake the decontamination process, they must nonetheless have a procedure and maintain a record regarding their sub-contracting and management of medical devices as per Decontamination Document System (DDS) 15. Version 1.0: May 2013 Page 6 of 10

Appendix 1 Column 1 Column 2 Facilities Requirements for a compliant LDU which is only reprocessing devices owned by the same legal entity Compliant with the design layout of SHPN 13 Part 2 One room model 5 Requirements for a compliant LDU reprocessing devices owned by a different legal entity, where the devices are located in the same building Compliant with the design layout of SHPN 13 Part 2 One room model 5 Equipment Use of automatic washer disinfector & sterilizer in compliance with the relevant standards a Installation and annual revalidation in accordance with the current guidance b Operation, maintenance and testing in accordance with the manufacturer s instructions c Use of automatic washer disinfector & sterilizer in compliance with the relevant standards a Installation and annual revalidation in accordance with the current guidance b Operation, maintenance and testing in accordance with the manufacturer s instructions c Management Process The role of User, and Operator within the LDU must be defined d The User and Operator must have training records appropriate to their needs Completion of NHS Education for Scotland training e Appropriate documentation of policy, procedures and records f Decontamination process in accordance with the device manufacturer s instructions 1 Production of sterilized product Sterilized devices must be packed in suitable containers to provide protection and to minimise contamination 5 When transported off-site g, contaminated devices must be packed and transported in suitable containers in accordance with the guidance 13-14 The role of User, Operator and Management within the LDU must be defined d The User, Operator and Manager must have training records appropriate to their needs Completion of NHS Education for Scotland training e Appropriate documentation of policy, procedures and records f Service Level Agreement (section 4.0) Method to differentiate devices owned by diffferent legal entities e.g. electronic tracking system, or colour coded cassette, or a time slot allocation Decontamination process in accordance with the device manufacturer s instructions 1 Production of sterilized product Sterilized devices must be packed in suitable containers to provide protection and to minimise contamination 5 When transported off-site g, contaminated devices must be packed and transported in suitable containers in accordance with the guidance 13-14 Table 1: Technical requirements for a compliant dental LDU Version 1.0: May 2013 Page 7 of 10

Note: a) The current standard for benchtop sterilizers is BS EN ISO 13060 16, while the current standard for washer disinfectors is BS EN ISO 15883:1,2 17-18. All equipment in NP 143 is in compliance with the relevant standards and guidance. NP143 is a national procurement contract for benchtop, underbench and free standing decontamination equipment used in LDUs. (https://www.scotcat.scot.nhs.uk/cdsnet/cdsnet.asp) b) Installation and annual revalidation must follow the current guidance consisting of SHTM 2010 19 for sterilizers and SHTM 2030 20 for washer disinfectors or their revision. Confirm with the suppliers who carried out the installation and annual revalidation to ensure their works are in accordance with SHTM 2010 and SHTM 2030. Advice from an Authorising Engineer (Decontamination) regarding validation may be required. c) The periodic testing requirements are: - Minimum frequency of testing decontamination equipment is to follow manufacturer s instructions. In line with CDO letter SGHD/CDO (2010)2 21 - LDU owners/managers have the responsibility to risk assess the suitability of the manufacturer instructions for their decontamination equipment to ensure they meet the required quality standard and compatible with the devices and decontamination process. In the absence of manufacturer s instructions or where there is inadequate or unclear manufacturer instruction, the frequency, methods and outcomes of tests must follow current guidance and the appropriate European Standards 16-18 d) SHTM 2010 19 and SHTM 2030 20 define the following roles: User is defined as the person designated by management to be responsible for the sterilizer/washer disinfector. In primary care he or she could be a general practitioner, dentist, or other health professional. Operator is defined as any person with the authority to operate a sterilizer/washer disinfector including the noting of device readings and simple housekeeping duties. Management is defined as the owner, occupier, employer, general manager, chief executive or other person who is ultimately accountable for the sole operation of its premises. e) NHS Education for Scotland (NES) provides on-site training on infection control covering decontamination. (http://www.nes.scot.nhs.uk/education-and-training/bydiscipline/dentistry/areas-of-education/decontamination.aspx) f) Policies, procedures and records for all aspects of management of medical devices and decontamination of reusable medical devices must be in place. DDS 15 is an example. g) Transport off site means via road which is scoped in the ADR 13. Guidance regarding transportation of medical devices can be found at HFS website 14 (http://www.hfs.scot.nhs.uk/home). LDUs reprocessing devices owned by a different legal entity must be located within the same building, therefore transport off site is only for domiciliary purposes. Version 1.0: May 2013 Page 8 of 10

References 1. The Medical Devices Regulations 2002, SI 2002 No 618.(MDR amended regulations 2012 SI2012 No1426) http://www.legislation.gov.uk/uksi/2002/618/contents/made http://www.legislation.gov.uk/uksi/2012/1426/pdfs/uksi_20121426_en.pdf 2. DB (2006) 04 Single-use Medical Devices: Implications and Consequences of Reuse, Medicines and Healthcare products regulatory agency (MHRA), version 2.0 http://www.mhra.gov.uk/publications/safetyguidance/devicebulletins/con2024 995) 3. SEHD/CMO (2007) 5, Important Advice for Dentists on Re-use of Endodontic Devices and Variant Creutzfeldt-Jacob Disease (vcjd), Scottish Executive Health Department 19 April 2007 http://www.sehd.scot.nhs.uk/ 4. The National Health Service (General Dental Services) (Scotland) Regulations 2010, SSI 2010 No 208, 2 July 2010 http://www.legislation.gov.uk/ssi/2010/208/contents/made 5. Scottish Health Planning Note 13 Part 2 Decontamination Facilities: Local Decontamination Units (2008), Health Facilities Scotland, http://www.hfs.scot.nhs.uk/publications-1/decontamination/ 6. The Glennie Framework, Sterile Services Provision Review Group: First Report, 2001, http://www.sehd.scot.nhs.uk/publications/sspr/sspr-11.htm 7. NHS HDL (2005) 1, Decontamination Compliance in Primary Care, Scottish Executive Health Department, 11 January 2005. http://www.sehd.scot.nhs.uk/mels/hdl2005_01.pdf 8. NHS HDL (2006) 40, Decontamination Updated guidance on compliance in primary care, Scottish Executive Health Department, July 2006. http://www.sehd.scot.nhs.uk/mels/hdl2006_40.pdf 9. Local Decontamination Units: Guidance on the Requirements for Equipment, Facilities and Management, Health Protection Scotland, Version 1.2, October 2005 (Amended August 2007), http://www.documents.hps.scot.nhs.uk/hai/decontamination/publications/ldu- 001-02-v1-2.pdf 10. SGHD/CDO(2009)1 Decontamination of Dental Devices in Primary Care Timescales for Compliance, 5 November 2009. http://www.sehd.scot.nhs.uk/publications/cdo(2009)01.pdf 11. Health and Safety at Work etc. Act 1974, SI 1974 c 37, http://www.legislation.gov.uk/ukpga/1974/37/contents Version 1.0: May 2013 Page 9 of 10

12. Management of Health and Safety at Work Regulations 1999, SI 1999 No. 3242 (Amendment Regulations 2006). http://www.legislation.gov.uk/uksi/1999/3242/contents/made http://www.legislation.gov.uk/uksi/2006/438/contents/made 13.ADR, European Agreement Concerning the International Carriage Of Dangerous Goods by Road, Volume 1, ECE/TRANS/225(Vol.1), Applicable as from 1 January 2013, Economic Commission for Europe Committee on Inland Transport, United Nations, New York and Geneva, 2012 http://www.unece.org.unecedev.colo.iway.ch/trans/danger/publi/adr/adr2013/13 contentse.html 14. Guide to the Carriage of Dangerous Goods Regulations with respect to used medical devices, Health Facilities Scotland, (draft), March 2013. 15. Decontamination Documentation System, Health Facilities Scotland http://www.pcdds.scot.nhs.uk/ 16. BS EN 13060 + A2 2010 Small steam sterilizers, British Standards Institution, 2010. http://shop.bsigroup.com/en/searchresults/?q=bs%20en%2013060 17. BS EN ISO 15883-1:2009 Washer-disinfectors. General requirements, terms and definitions and tests, British Standards Institution October 2009. http://shop.bsigroup.com/en/searchresults/?q=bs%20en%2015883 18. BS EN ISO 15883-2:2009 Washer-disinfectors. Requirements and tests for washer-disinfectors employing thermal disinfection for surgical devices, anaesthetic equipment, bowls, dishes, receivers, utensils, glassware, etc., British Standards Institution, October 2009. http://www.hfs.scot.nhs.uk/services/about/engineering-andenvironment/decontamination-services/guidance/ 19. SHTM 2010 (Parts 1 6) Sterilization, Health Facilities Scotland, June 2001. http://www.hfs.scot.nhs.uk/online-services/publications/engineering/shtm- 2010/ 20. SHTM 2030: Washer Disinfectors, Health Facilities Scotland, October 2001. http://www.hfs.scot.nhs.uk/online-services/publications/engineering/shtm- 2030/ 21. Primary and Community Care Directorate SGHD/CDO(2010)2, Decontamination-Testing, Maintenance and Revalidation of Equipment, Scottish Government Health Department,. http://www.scottishdental.org/?record=304 Version 1.0: May 2013 Page 10 of 10