Detailed Certificate of Calibration

Similar documents
Procedure for Equipment Calibration and Maintenance

Instruction Manual FL

Force/position control of a robotic system for transcranial magnetic stimulation

Torque Transducers MEASURING ELECTRONIC

The Universal DAQ Device. Connect and measure immediately!

Calibration Service Selection Guide

ATI ROBOTIC END EFFECTORS. Engineered Products for Robotic Productivity

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

Model 601A02. Low-cost Industrial ICP Accelerometer. Installation and Operating Manual

KRAEMER Tablet Testing System

SCHATZ - TEST Tool testing systems. SCHATZ -certest-w. Dynamic testing of torque tools

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

Machine Tool Inspection & Analyzer solutions

Software Production. Industrialized integration and validation of TargetLink models for series production

Series 6000 Torque measured metal bellow coupling

CALIBRATION PRINCIPLES

Understand, Maintain and Service Your Torque Wrench

TI GPS PPS Timing Application Note

SOFTWARE MANAGEMENT PROGRAM. Software Testing Checklist

Calibration Certificate

WEATHER STATION FOR SOLAR FARM MONITORING

Development of Robotic End-Effector Using Sensors for Part Recognition and Grasping

Digital Magnetometer Systems - DM Series

Subminiature Load Cell Model 8417

The Unique Accelabar Flow Meter

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Advances in the Design of the icub Humanoid Robot: Force Control and Tactile Sensing

MICROMAT-F / MINIMAT-F SCREWDRIVING SYSTEM

Global Water Instrumentation, Inc.

Mass Flow Meters & Controllers

Conductivity Sensor Calibrations to Meet Water Industry Requirements

Frequently Asked Questions (FAQs)

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Best Practices for Reducing Transmitter Life Cycle Costs

PART 1 - INTRODUCTION...

GMP 11. Good Measurement Practice for Assignment and Adjustment of Calibration Intervals for Laboratory Standards

Force measurement. Forces VECTORIAL ISSUES ACTION ET RÉACTION ISOSTATISM

MINIMAT-EC-Servo Screwdriver Spindles

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

Calibration Solutions. be certain.

Hollow Cylinder Apparatus (GDS SS-HCA)

Webserver. Real time curves, trending, monitoring, reports, export

testing equipment for quality management Programme summary. METROLOGY Tensile and Pressure Testing Machines Measuring Devices Display Devices

OPERATOR S MANUAL SUPPORTED TORQUE CALIBRATION BEAM. Part Number Issue 4 Original Instructions (English)

Basler pilot AREA SCAN CAMERAS

unless the manufacturer upgrades the firmware, whereas the effort is repeated.

User checks and maintenance of laboratory balances

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

Infrared Thermometer Calibration A Complete Guide

Beamex. Calibration White Paper. How often should instruments be calibrated

Toroidal Conductivity Sensor

OPERATIONAL STANDARD

Agilent Automotive Power Window Regulator Testing. Application Note

KALIBRERINGSBEVIS. 25 temperature loggers Ecoguard model TS , identification se table of results.

Meteorological SPACE WEATHER SPECIAL! BRITISH ANTARCTIC SURVEY The meteorological capabilities and work of the BAS explained

EC /4" quickchange EC GE /8" square with EC

To measure an object length, note the number of divisions spanned by the object then multiply by the conversion factor for the magnification used.

Sentinel I28 and Blackbelt Mass Flow Calibration and Verification

The modular Line and Room Gantry design from SCHUNK

How To Program A Laser Cutting Robot

CRM s and the Dilemma of the 2nd Source. Shawn Kassner, Sr Product Manager Tim Miller, Sr Organic Chemist Phenova, A Phenomenex Company

High Precision Measurement of the Target Mass of the Daya Bay Neutrino Detectors

Beamex. Calibration White Paper. How often should instruments be calibrated?

F1 Fuel Tank Surging; Model Validation

ISO/IEC QUALITY MANUAL

User Guide MTD-3. Motion Lab Systems, Inc.

Temp. & humidity Transmitter Instructions

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Transducer Mounting and Test Setup Configurations. Rick Bono The Modal Shop

Quality Management System Policy Manual

Improving Workflow Efficiency using the Trimble R10 with SurePoint. Marco Wuethrich Trimble Applications Specialist

Druck DPI 142/150. GE Infrastructure Sensing. Pressure Indicator Calibration manual - K382

6703/6704 ANALOG OUTPUT DEVICE CALIBRATION PROCEDURE

Silicon Pyranometer Smart Sensor (Part # S-LIB-M003)

Turbine Flowmeters for Gas Applications

'INSIZE' is becoming an international brand.

PPM Users Manual Signature Software

ISO Accreditation for a Standing Start Finish (SSF) Primary Flow Stand with Coriolis Flowmeters as Reference Standards.

A.1 Sensor Calibration Considerations

NEW. EVEN MORE data acquisition and test stand automation

Quick Start Guide , Rev DA March Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator

Basler scout AREA SCAN CAMERAS

Wireless Data Logger Monitoring Systems

IRIZAR TANK JACKING SYSTEM LOAD TEST ON LIFTING JACK MODEL HLJ 12

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

An Overview of Calibration Methods and Procedures for Process and Inventory Weigh Systems

Using Equotip Hardness Test Blocks Abstract 1. Introduction 2. Verification of Leeb hardness testers according to standards

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

Everything you need for protection scheme testing

DataView DVTH Data Logger for Temperature and Humidity

Evaluating the Accuracy of Maxim Real-Time Clocks (RTCs)

10 Thomas, Irvine, CA USA Tel: (949) Fax: (949) Toll Free: (800) 23 FUTEK

IAS CALIBRATION and TESTING LABORATORY ACCREDITATION PROGRAMS DEFINITIONS

RUSKA PRODUCTS - PRICE LIST

NI 6601/6602. Contents CALIBRATION PROCEDURE. ni.com/manuals

Overview. Proven Image Quality and Easy to Use Without a Frame Grabber. Your benefits include:

Calibration & Preventative Maintenance. Sally Wolfgang Manager, Quality Operations Merck & Co., Inc.

Load Cell Accuracy in Relation to the Conditions of Use

Transcription:

Detailed Certificate of Calibration Equipment Calibrated Description: Six-Axis Force/Torque Sensor Manufacturer: ATI Industrial Automation Serial Number: FT13705 Model: Mini45 Calibration: SI-580-20 Electronics: Net F/T Gain Multiplier: 100% Customer Information Ms. Ute Pfeffer SCHUNK GmbH & Co. KG Bahnhofstraße 106-134 Lauffen/Neckar, D-74348 GERMANY ute.pfeffer@de.schunk.com Equipment Condition and Notes: Factory new. Calibration Results: Passed Offset: Normal Gain: Normal Calibrated Ranges (±): 580 N 580 N 1160 N 20 N-m 20 N-m 20 N-m Measurement Uncertainty (95% confidence level, percent of full-scale load): 1.50% 1.25% 1.00% 1.25% 1.75% 1.00% The above Measurement Uncertainty values are the maximum amount of error for each axis expressed as a percentage of its full-scale load. Calibration Temperature: 22.2 ±1.1 C (72 ±2 F) Temperature Compensation: hardware Calibration Method: WI-FTP-105, Net FT Calibration Instructions Date of Calibration: 02 May 2013 Certificate Date: 02 May 2013 Calibrated by: Melvin Wells, Calibration Technician Page 1 of 6

This calibration is traceable to the National Institute of Standards and Technology (NIST). Calibration standards (not all of the listed standards are used for this calibration): Calibration Equipment Description Identification Calibration Tool FTT-1922 DAQ, 200KS/S, 16-BIT, 16 AN CNTLR-2002-1 DAQ, 200KS/S, 16-BIT, 16 AN CNTLR-2015-3 DAQ, 200KS/S, 16-BIT, 16 AN CNTLR-2025-2 3X STND-ALN CONTROLLER CNTLR-2040 3X STND-ALN CONTROLLER CNTLR-2042 3X STND-ALN CONTROLLER CNTLR-2050 PCI-6034E CNTLR-2060-4 30K LOAD CELL FTT-1990 9105-NETB BOX #2 FTT-1999 SS Hook Weights WHT-1700 Weights Type II WHT-1706 WHT-1707 WHT-1708 Brass Set of 13 Weights WHT-1709 WHT-1720 WHT-1730 ATI Industrial Automation (ATI) certifies that the above product was calibrated in accordance with applicable ATI procedures. These procedures are compliant with the ISO 9001 standard to ensure that the above product is within ATI specifications. To meet this level of accuracy any loads must be correctly aligned to the transducer origin and the transducer must be mounted to a sufficiently strong surface. To ensure the transducer measurement uncertainties listed on page 1 are met, more-conservative limits are used as calibration targets during the calibration process. If any of the calibration targets are exceeded the calibration will not pass. It is possible for a transducer to exceed these calibration targets while meeting the page 1 measurement uncertainties. The following calibration targets were used for this transducer: Fx=1.25%, Fy=1.00%, Fz=0.75%, Tx=1.00%, Ty=1.50%, and Tz=0.75%. Note: If this is a recalibration of a legacy transducer that does not have precision locating features (such as dowel holes), there could be additional error in Tx and Ty due to inexact mounting location. Precision locating features are highly recommended for best accuracy and can be added by ATI. This certificate shall not be reproduced except in full without written approval from ATI. This certificate only applies to the items listed and does not include unlisted ancillary items such as data acquisition equipment. For questions or comments, please contact your ATI representative. Page 2 of 6

Calibration Accuracy Section Sensor System FT13705, Mini45/SI-580-20 Force units: N; Torque units: N-m Calibrated Ranges (±) 580 580 1160 20 20 20 Applied Loads 1 0.000 164.584 0.000-16.704 0.000 0.000 2-164.584 0.000 0.000 0.000-16.704 0.000 3 0.000-164.584 0.000 16.704 0.000 0.000 4 164.584 0.000 0.000 0.000 16.704 0.000 5 0.000 467.063 0.000-14.174 0.000 0.000 6-467.063 0.000 0.000 0.000-14.174 0.000 7 0.000-467.063 0.000 14.174 0.000 0.000 8 467.063 0.000 0.000 0.000 14.174 0.000 9 0.000 155.688 0.000-1.186 0.000-17.802 10 0.000 155.688 0.000-1.186 0.000 17.815 11-155.688 0.000 0.000 0.000-1.186-17.810 12-155.688 0.000 0.000 0.000-1.186 17.791 13 0.000-155.688 0.000 1.186 0.000-17.815 14 0.000-155.688 0.000 1.186 0.000 17.802 15 155.688 0.000 0.000 0.000 1.186-17.791 16 155.688 0.000 0.000 0.000 1.186 17.810 17 0.000 0.000 222.411-16.950 0.000 0.000 18 0.000 0.000 222.411 0.000-16.952 0.000 19 0.000 0.000 222.411 16.976 0.000 0.000 20 0.000 0.000 222.411 0.000 16.958 0.000 21 0.000 0.000 1023.091 0.000 0.000 0.000 22 0.000 0.000-1023.091 0.000 0.000 0.000 23 0.000 0.000-222.411 16.950 0.000 0.000 24 0.000 0.000-222.411 0.000 16.952 0.000 25 0.000 0.000-222.411-16.976 0.000 0.000 26 0.000 0.000-222.411 0.000-16.958 0.000 Page 3 of 6

Full-Scale Error 1-0.50% 0.06% 0.14% 0.07% 0.62% 0.02% 2 0.35% -0.08% -0.05% -0.21% -0.41% -0.11% 3-0.48% -0.04% 0.13% 0.01% 0.49% -0.10% 4 0.52% 0.02% -0.09% -0.12% -0.46% 0.10% 5-0.74% 0.39% 0.26% 0.23% 0.50% -0.05% 6 0.44% -0.23% 0.12% -0.12% -0.52% -0.12% 7-0.76% 0.05% 0.29% 0.24% 0.62% 0.14% 8 0.69% -0.28% 0.09% -0.09% -0.48% -0.16% 9 0.03% -0.44% 0.05% -0.02% 0.25% 0.33% 10-0.03% -0.37% 0.05% -0.05% -0.08% 0.12% 11 0.20% -0.04% 0.00% -0.18% 0.11% 0.01% 12 0.45% -0.34% -0.02% 0.15% -0.22% 0.01% 13-0.04% 0.12% 0.04% -0.09% -0.28% -0.09% 14 0.03% 0.22% 0.00% 0.06% 0.27% 0.08% 15-0.11% -0.20% 0.05% 0.14% -0.09% -0.05% 16-0.35% -0.08% 0.10% -0.30% 0.03% -0.01% 17-0.54% 0.10% -0.07% 0.25% 0.37% 0.00% 18 0.37% -0.08% -0.21% -0.28% -0.42% -0.07% 19-0.54% 0.20% -0.02% 0.01% 0.43% 0.05% 20 0.29% -0.14% -0.19% -0.54% -0.57% -0.20% 21-0.09% -0.11% 0.09% 0.15% -0.14% -0.11% 22-0.13% -0.10% -0.06% -0.12% -0.23% -0.09% 23-0.47% 0.20% 0.04% 0.49% 0.27% -0.08% 24 0.26% -0.11% 0.03% 0.06% -0.09% -0.13% 25-0.48% 0.02% 0.10% 0.21% 0.31% -0.01% 26 0.44% -0.10% 0.00% -0.09% -0.21% -0.09% Offset Report F/T Offset 0.0229 0.0079 0.0227-0.0001 0.0002-0.0009 SG0 SG1 SG2 SG3 SG4 SG5 SG Offset 0.4600 0.9200 0.1200 0.2350 0.1450 0.9650 ±SG Limit 1599.9638 1599.9638 1599.9638 1599.9638 1599.9638 1599.9638 Offsets are measured in a unique configuration not available to the user. Page 4 of 6

Gain-Check Report SG0 SG1 SG2 SG3 SG4 SG5 Lower Limit 0.7500 0.7500 0.7500 0.7500 0.7500 0.7500 Lower Output 0.8702 0.8959 0.8342 0.8850 0.8523 0.8180 Upper Output 0.8762 0.9145 0.8632 0.9024 0.8703 0.8288 Upper Limit 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 Gain readings are measured in a unique loading configuration. Page 5 of 6

As part of our commitment to quality, each ATI force/torque transducer undergoes rigorous accuracy testing. This process, which involves applying and verifying a rich set of loading cases designed to cover the transducer s entire six-axis calibrated range, is designed to ensure that your transducer meets the measurement uncertainties listed in this Certificate of Calibration. Our transducers often exceed our quality standards for accuracy. Often, transducers perform exceptionally well in certain loading situations. This report summarizes the performance of your ATI F/T transducer in our factory tests. It can be thought of as a best-case scenario snapshot of your transducer s performance under laboratory conditions, in a variety of loading situations. You can expect the accuracy of your transducer measurements to fall somewhere between its performance during testing and the measurement uncertainties listed on its calibration certificate. The Calibration Accuracy Section contains several tables of data. The Calibrated Ranges (±) table lists the transducer s rated range for each axis. The Applied Loads table lists the loads applied during calibration and testing. The Full-Scale Error table shows the sensor system s measurement error as a percentage of full scale for each axis in each loading case. The Offset Report table shows transducer readings during offset adjustment and associated control limits. And the Gain-Check Report table shows verification of the transducer s sensitivity and associated control limits. If included, the Before and After Report table shows a loading case relating the transducer s performance as received to its performance after recalibration. For best accuracy, be sure to use your transducer s precision location features, and mount your transducer to a stiff surface. If an ongoing guarantee of sensor accuracy is important to you, we recommend that your sensor be tested annually. Contact your ATI Industrial Automation distributor to schedule recalibrations. Page 6 of 6