NRC Publications Archive Archives des publications du CNRC



Similar documents
Research Letter Biomimetic Composite-Metal Hip Resurfacing Implant

Computer Aided Engineering (CAE) Techniques Applied To Hip Implant

Custom Design of Knee Joint Prosthesis By Using Computerized Tomography (CT) Images and 3D Modelling

Wear-contact analysis of hip implant coated with functionally graded material

Why an Exactech Hip is Right for You

ReCap Product Rationale

on-metal Hips: Device Mechanics and Failure Modes

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE. Health Technology Appraisal

Hip Resurfacing 2011 ORIGINAL ARTICLE. James W. Pritchett MD. Introduction. Abstract

The Right Choice. Exeter. total hip system

Acetabular Wedge Augment System

In this brochure you will: Keep in mind:

BONE PRESERVATION STEM

Total Hip Joint Replacement. A Patient s Guide

Answers to commonly asked questions from patients with metal-on-metal hip replacements / resurfacings. Contents

Metasul LDH Large Diameter Head

Metal-on-Metal Hip Systems

M 2 a-magnum. Design Rationale. Large Metal Articulation. Knees Hips Extremities Cement and Accessories PMI. Technology

TOTAL HIP REPLACEMENT FOR A LIFETIME: THE CEMENTLESS METAL ON METAL RECONSTRUCTION

Medical Device Alert. Device All metal-on-metal (MoM) hip replacements. Action by. CAS deadlines. Ref: MDA/2012/036 Issued: 25 June 2012 at 11:00

Lap Fillet Weld Calculations and FEA Techniques

How To Make An Implant From A Metal That Is Like Bone

Randal S. Ford. ATTORNEY AT LAW (205) DePuy ASR Hip Implant Recall Fact Sheet

Exeter. Surgical Technique. V40 Stem Cement-in-Cement. Orthopaedics

Photograph showing the components of an artificial total hip

Information for Our Patients Regarding Metal-on-Metal (MoM) Hip Replacements

PERIPROSTHETIC IMPLANTS

The information contained in this document is intended for healthcare professionals only.

NRC Publications Archive Archives des publications du CNRC

An Alternative Conservative Approach to Hip Reconstruction

AC : ENHANCING FUNDAMENTAL MATERIALS ENGINEERING EDUCATION USING BIOMEDICAL DEVICES AND CASE STUDIES

EBM Inside. Additive Manufacturing of orthopedic implants

The Journal of Arthroplasty

frequently asked questions Knee and Hip Joint Replacement Technology

A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF MANDIBULAR OVERDENTURE SUPPORTED BY CYLINDRICAL AND CONICAL IMPLANTS

Introduction to Solid Modeling Using SolidWorks 2012 SolidWorks Simulation Tutorial Page 1

Introduction to Biomaterials in Orthopaedic Surgery

PRESENTATIONS/PAPERS INTERNATIONAL. RAISING STANDARDS IN JOINT ARTHROPLASTY Course Co-Chairman, The Great Debate - London, June 2013

ABGII Cement Free Total Hip Replacement System

INTRODUCTION Cerclage Cable Vs. Monofilament Wire

High-Flex Solutions for the MIS Era. Zimmer Unicompartmental High Flex Knee System

Appendice Caratteristiche Dettagliate dei Materiali Utilizzati

Accolade. System. Brochure. Achieving Perfect Balance. Cemented and Cementless Femoral Hip System

Modal and Vibration Analysis of Functionally Graded Dental Implant

Materials Sciences. Dr.-Ing. Norbert Hort International Masters Programme in Biomedical Engineering

Clinical Testing for Metal-on-Metal Prosthetic Wear and Tear

INJECTION MOLDING COOLING TIME REDUCTION AND THERMAL STRESS ANALYSIS

Numerical Analysis of Independent Wire Strand Core (IWSC) Wire Rope

The mechanical behavior of the bone microstructure around dental implants

PMA P Cormet 2000 Hip Resurfacing System

Minimally Invasive Hip Replacement through the Direct Lateral Approach

Clinically Proven Fiber Metal Material. Power to choose advanced bearing technologies to match patient demands

DIRECT FABRICATION OF METAL ORTHOPEDIC IMPLANTS USING ELECTRON BEAM MELTING TECHNOLOGY. [Reviewed, accepted August 13, 2003] Abstract.

Implant materials. Learning outcomes. Implant materials in trauma. How to use this handout? Functions of implants. Types of materials

Modular Dual Mobility Acetabular Components: An Important Extension of a Proven Approach to Hip Instability

Patient Labeling Information System Description

NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE

Metallurgical analysis of five failed cast cobalt-chromium-molybdenum alloy hip prostheses

Artificial Hip Implants 2011

Vincent Constantin, CADFEM (Suisse) AG

.URGENT DEVICE CORRECTION

Metal-On-Metal Hip Resurfacing for Young Active Adults with Degenerative Hip Disease

Report on the Use of Numerical Analysis for Strength Evaluation of Orthopedic Implants

Material Optimization and Weight Reduction of Drive Shaft Using Composite Material

Sinterstation. Pro Direct Metal SLM System

VERILAST Technology for Hip Replacement Implants

Surgical technique. Sagitta EVL

HexWeb CR III Corrosion Resistant Specification Grade Aluminum Honeycomb

Radiologic Assessment of Total Hip Arthroplasty: Loosening

ANALYSIS OF GASKETED FLANGES WITH ORDINARY ELEMENTS USING APDL CONTROL

Technology Breakthrough in Spinal Implants (Technical Insights)

Metal on Metal Hips. Total Hip Replacement. Total Hip Replacement

YOUR GUIDE TO TOTAL HIP REPLACEMENT

Cormet Hip Resurfacing System

Creation of an Unlimited Database of Virtual Bone. Validation and Exploitation for Orthopedic Devices

Polyethylene Hip Resurfacing for Women

DePuy Orthopaedics ASR Recall Reference Guide for U.S. Healthcare Professionals

Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

Material data sheet. EOS CobaltChrome MP1. Description

Appendix B: FDA Safety Communication (Website) for MoM Hip Systems

A Case Study Comparing Two Approaches for Applying Area Loads: Tributary Area Loads vs Shell Pressure Loads

USE OF SIMULATION TO IMPROVE CARDIOVASCULAR STENT DEVELOPMENT

CeSpace Titanium / PEEK

Taperloc Complete Hip System

Technical Report Example (1) Chartered (CEng) Membership

Hip Resurfacing (Re-Review)

A Magazine Dedicated to Mass Torts Law. The Dangers of Metal-on-Metal Hips. Details of DePuy ASR Settlement Announced.

The information contained in this document is intended for healthcare professionals only.

Imagine being an orthopedic surgeon and knowing that your patient s

Burst Pressure Prediction of Pressure Vessel using FEA

Evaluation of Total Hip Arthroplasty Research in the US and Europe. Marcy J Simmons A THESIS. submitted to. Oregon State University

Biomechanics of Joints, Ligaments and Tendons.

COMPUTATIONAL ENGINEERING OF FINITE ELEMENT MODELLING FOR AUTOMOTIVE APPLICATION USING ABAQUS

The University of Birmingham (Live System)

NCB Periprosthetic Femur Plate System. Surgical Technique

ACCOLADE II. Orthopaedics. Femoral Hip System. Surgical Technique

Mechanical Properties of Metals Mechanical Properties refers to the behavior of material when external forces are applied

Anterior Approach. to Hip Replacement Surgery

Advanced bolt assessment through process automation

DRAFT. Triathlon TS Knee System. Surgical Protocol. Version 1

Transcription:

NRC Publications Archive Archives des publications du CNRC Biomimetic Composite-Metal Hip Resurfacing Implant Bougherara, Habiba; Bureau, Martin This publication could be one of several versions: author s original, accepted manuscript or the publisher s version. / La version de cette publication peut être l une des suivantes : la version prépublication de l auteur, la version acceptée du manuscrit ou la version de l éditeur. For the publisher s version, please access the DOI link below./ Pour consulter la version de l éditeur, utilisez le lien DOI ci-dessous. Publisher s version / Version de l'éditeur: http://dx.doi.org/10.1155/2008/368985 Research Letters in Materials Science, 2008, Article ID 368985, pp. 1-4, 2008 NRC Publications Record / Notice d'archives des publications de CNRC: http://nparc.cisti-icist.nrc-cnrc.gc.ca/npsi/ctrl?action=rtdoc&an=11708243&lang=en http://nparc.cisti-icist.nrc-cnrc.gc.ca/npsi/ctrl?action=rtdoc&an=11708243&lang=fr Access and use of this website and the material on it are subject to the Terms and Conditions set forth at http://nparc.cisti-icist.nrc-cnrc.gc.ca/npsi/jsp/nparc_cp.jsp?lang=en READ THESE TERMS AND CONDITIONS CAREFULLY BEFORE USING THIS WEBSITE. L accès à ce site Web et l utilisation de son contenu sont assujettis aux conditions présentées dans le site http://nparc.cisti-icist.nrc-cnrc.gc.ca/npsi/jsp/nparc_cp.jsp?lang=fr LISEZ CES CONDITIONS ATTENTIVEMENT AVANT D UTILISER CE SITE WEB. Contact us / Contactez nous: nparc.cisti@nrc-cnrc.gc.ca.

Hindawi Publishing Corporation Research Letters in Materials Science Volume 2008, Article ID 368985, 4 pages doi:10.1155/2008/368985 Research Letter Biomimetic Composite-Metal Hip Resurfacing Implant Habiba Bougherara and Martin N. Bureau Department of Mechanical and Industrial Engineering, Ryerson University, ON, Canada M5B 2K3 Correspondence should be addressed to Habiba Bougherara, habiba.bougherara@ryerson.ca Received 7 April 2008; Accepted 18 June 2008 Recommended by Steve J. Bull Hip resurfacing technique is a conservative arthroplasty used in the young patient in which the femoral head is reshaped to accept metal cap with small guide stem. In the present investigation, a hybrid composite-metal resurfacing implant is proposed. The cup is made of carbon fiber/polyamide 12 (CF/PA12) covered with a thin layer of cobalt chrome (Co-Cr). Finite element (FE) method was applied to analyze and compare the biomechanical performances of the hybrid hip resurfacing (HHR) and the conventional Birmingham (BHR). Results of the finite element analysis showed that the composite implant leads to an increase in stresses in the cancellous bone by more than 15% than BHR, indicating a lower potential for stress shielding and bone fracture and higher potential for bone apposition with the HHR. Copyright 2008 H. Bougherara and MartinN. Bureau. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. 1. INTRODUCTION The successful reintroduction of the improved metal-onmetal (MOM) bearings has led to a resurgence of interest for hip resurfacing procedure as a viable alternative to conventional arthroplasty for younger and more active patients [1, 2]. The reported benefits of hip resurfacing (HR) include reduced dislocation rate and increased function compared to total hip arthroplasty (THA) [3, 4]. Other advantages of HR compared with THA include minimal bone resection, easier revision, and reduction in the stress shielding in the proximal femur [1, 5]. Femoral neck fracture and stress shielding problems remain a concern with resurfacing hip prostheses [6, 7]. Currently, most implants for joint replacements including HR are manufactured from stiff materials (i.e., stainless steel, Co-Cr, etc.). These materials undergo stress shielding that may lead to implant loosening and femoral neck fracture [8]. Currently, conventional implants still undergo problems of biomechanical mismatch of elastic modulus and interfacial stability with host tissues. Fortunately, fiber-reinforced polymer composites provide an interesting solution to face these problems since they have excellent mechanical properties, such as high fatigue and creep resistance, rigidity, and stiffness. Moreover, these materials have rapid, versatile, and inexpensive fabrication processes. The feasibility of the proposed biomimetic polymer composite was previously used to manufacture a hip stem for THA. This hip stem described by Campbell et al. [9] and Bougherara et al. [10] was evaluated numerically and experimentally. Preliminary tests investigating the biocompatibility of the biomimetic composite stem showed that the composite produced no adverse cytotoxic response in the periprosthetic tissues [11, 12], and tests using simulated body fluid conditioning showed that the hydroxyapatite- (HA) coated composite has excellent potential of biocompatibility [13]. This new biomimetic composite implant has the ability to mimic the functions of the natural bone that will allow stable fixation of prosthesis with minimal bone loss through stress shielding. The biocompatibility of this new biomimetic composite was verified [14, 15]. Miniature implants made of the same materials and of HA-coated Ti as control were produced and inserted as femoral intramedullary implants in rabbits. Hystomorphometric results for both composite and control implants (HA-coated Ti) showed that the composite implants were highly osseoinductive, by more than one order of magnitude with respect to control (implant coverage exceeding 100% of nominal implant perimeter). The protocol used here thus led us to conclude that the HAcoated PA12/CF composites have the potential to lead to very good osseoconduction that may reduce stress shielding leading to bone resorption.

2 Research Letters in Materials Science Co-Cr surface CF/PA12 PMMA C B Figure 1: Hip resurfacing. Hybrid HR and Birmingham HR. Angle fiber Figure 2: Composite (CF/PA12) stem braided (+45/ 45) 6. A B C A Displacement Joint force: 3704.9N Muscle force: 1085.2N (c) Figure 3: Geometry and load conditions, FE model of BHR, and (c) FE model of HHR. A novel hybrid composite Co-Cr hip resurfacing (HHR) implant is proposed to prevent stress shielding and bone fracture. The aim of this article is thus to present the concept design for the hybrid resurfacing implant and secondly, to compare its performance to conventional Birmingham hip resurfacing (BHR). Bounded contact Frictionless contact 2. MATERIAL AND METHODS 2.1. Concept design and 3D geometries Computerized tomography (CT) scan sections were performed every 0.5 mm along the length of the composite femur (sawbones 4th generation composite bone models) and used to generate the 3D solid model of the proximal femur [16] (see Figure 2). The elastic modulus of the simulated cortical (short fiber-filled epoxy) and cancellous (rigid polyurethane foam) based on ASTM D-638, D-695, and D-1621 tests were equal to 16.7 (GPa) and 206 (MPa). The concept and geometry of the hybrid resurfacing component are shown in Figure 1. The femoral cup with a diameter of 46 mm (Birmingham) is composed of 2 mmthick shell structure made of several layers of continuous carbon fiber/polyamide 12 (CF/PA12) composite fabrics (see Figure 2), onto which a 1 mm layer of Co-Cr is overlaid in order to avoid wear debris formation. The guide stem is composed of the same material as the cup (i.e., CF/PA12-Co- Cr). The cup is fixed to the femoral head with 1.5 mm cement made of PMMA. 2.2. Finite element models 3D FE models of a composite femur were meshed and analyzed using ANSYS 11.0 software. The femoral head was Figure 4: Type of contact used in the FEA. reamed and embedded with two types of hip resurfacing implants. The first was a model of the femoral bone in which the implanted HR was made of a Cr-Co-base alloy (E = 200 GPa, v = 0.3) (see Figure 3), while the second was the hybrid composite (CF/PA12) metal (Co-Cr) implant (see Figure 3(c)). The material properties used for the analysis are shown in Table 1. The models were meshed with 10 node quadratic tetrahedron elements (see Figure 3). Bonded contact was assumed at the cup-bone interfaces in view of simulating full bone ingrowth and perfect cement fixation. This resulted in a rigid link between the composite cup and the PMMA contact surfaces, allowing no relative sliding or gap opening. The bone-stem interface was simulated using frictionless contact allowing free sliding (see Figure 4). For each FE model, the load corresponded to 8 running and consisted of a 3704 kn load applied to the femoral head and a 1085 kn great trochanter muscles load [17]. The

H. Bougherara and MartinN. Bureau 3 Table 1: Mechanical properties of the bone-implant system. Material Modulus of elasticity (GPa) Shear modulus (GPa) Poisson s ratio E x = 15.4 3..3 CF/PA12 E y = 15.4 3.5.3 E z = 3.5 3.2.3 PMMA E=2..3 Cortical bone E = 16.7.3 Cancellous bone E =.206.3 6.09 max 5.42 4.74 4.06 3.39 2.71 2.03 1.35 0.677 0.000424 min 173.66 max 154.37 135.07 115.78 96.48 77.184 57.888 38.592 Min 19.296 0.0001082 min 5.26 max 4.67 4.09 3.5 2.92 2.34 1.75 1.17 0.585 0.0014 min 156.24 max 138.88 121.52 104.16 86.802 69.442 52.081 34.721 17.361 0.00021359 min Figure 5: Von Mises stress in the cancellous bone using BHR implant and HHR. loads were distributed over several nodes to avoid stress concentration, and for all FE analyses, the displacement of all nodes at the distal end of the femoral bone was rigidly constrained (Figure 3). 3. RESULTS 3.1. Stresses in the trabecular bone The von Mises stresses in the trabecular bone with the Cr- Co and CF/PA12 resurfacing implants are shown in Figure 5. The stress inside the trabecular bone was higher for the conventional Co-Cr resurfacing implant (von Mises stress between 0 and 4.7 MPa) than the one using the hybrid CF/PA12-Co-Cr (von Mises stress level ranged between 0 and 4.1 MPa). The highest stress patterns were noted in the posteroinferior region near the rim of the implant. Peak stresses were 6.09 MPa for the Co-Cr prosthesis and 5.26 MPa for the hybrid HR. 7.28 max 6.47 5.66 4.85 4.04 3.24 2.43 1.62 0.809 2.05e 5min (c) Figure 6: Von Mises stress in the implant using conventional (BHR), hybrid (HHR), and (c) stress distribution in the CF/PA12 shell. 3.2. Stresses in the implant The values of stresses in the conventional Co-Cr implant ranged between 0 and 77 compared to 0 and 69 MPa when the hybrid implant is used (see Figure 6). The peak stress in the conventional implant was higher (173.6 MPa) than that found in the hybrid implant (156.2).

4 Research Letters in Materials Science 4. DISCUSSION The new concept design for hip resurfacing using a hybrid composite metal was described. Finite element analysis has been performed to evaluate and analyze the potential of the proposed design concept. In the case of the hybrid implant, numerical results have shown that the von Mises stresses were more uniform and higher by more than 15% in the cancellous bone. This indicates the potential of the hybrid composite implant to reduce stress shielding, especially in the great trochanter region. Also higher peak stress in the cancellous bone was found when the Co-Cr is used, which may lead to one fracture. Again the use of the hybrid implant reduced considerably the peak bone stress in the cancellous bone and thus prevents from bone fracture. Results of simulation indicate also that the hybrid implant reduced the stress in the femoral cup by approximately 10 to 20%. Therefore, more loads are transferred to the bone with the hybrid composite Co-Cr resurfacing implant than the conventional ones. The main objective of the current work was to present a preliminary study on the metal composite femoral component. However, the FE model needs some improvements, such as the inclusion of the load bearing surfaces (i.e., acetabular cup). The thickness of this acetabular cup would be expected to affect the load transfer across the bearing surfaces. 5. CONCLUSIONS The outcome of this study showed that the hybrid composite metal hip resurfacing had the potential to reduce stress shielding, preserve bone stock, and prevent from bone fracture compared to conventional metallic hip resurfacing implants. REFERENCES [1] J. Daniel, P. B. Pynsent, and D. J. W. McMinn, Metal-onmetal resurfacing of the hip in patients under the age of 55 years with osteoarthritis, The Journal of Bone & Joint Surgery B, vol. 86, no. 2, pp. 177 184, 2004. [2] D. L. Back, R. Dalziel, D. Young, and A. Shimmin, Early results of primary Birmingham hip resurfacings. An independent prospective study of the first 230 hips, The Journal of Bone & Joint Surgery B, vol. 87, no. 3, pp. 324 329, 2005. [3] D. Adams and S. Quigley, Hip resurfacing: past, present and future, Journal of Orthopaedic Nursing, vol. 9, no. 2, pp. 87 94, 2005. [4] P. E. Beaulé, M. Le Duff, P.Campbell,F.J.Dorey,S.H.Park, and H. C. Amstutz, Metal-on-metal surface arthroplasty with a cemented femoral component: a 7 10 year follow-up study, The Journal of Arthroplasty, vol. 19, no. 8, supplement 1, pp. 17 22, 2004. [5] A. Ebied and S. Journeaux, (iv) Metal-on-metal hip resurfacing, Current Orthopaedics, vol. 16, no. 6, pp. 420 425, 2002. [6] R. Ramakrishnan, W. L. Jaffe, and W. R. Kennedy, Metal-onmetal hip resurfacing: radiographic evaluation techniques, The Journal of Arthroplasty. In press. [7] Y. Hayaishi, H. Miki, T. Nishii, T. Hananouchi, H. Yoshikawa, and N. Sugano, Proximal femoral bone mineral density after resurfacing total hip arthroplasty and after standard stem-type cementless total hip arthroplasty, both having similar neck preservation and the same articulation type, The Journal of Arthroplasty, vol. 22, no. 8, pp. 1208 1213, 2007. [8] A. M. Pearson, P. Foguet, C. Little, D. Murray, P. McLardy- Smith, and S. Krikler, Can we prevent fractures in hip resurfacing? The Journal of Bone & Joint Surgery B, vol. 87, supplement 1, p. 41, 2005. [9] M. Campbell, J. Denault, L. H. Yahia, and M. N. Bureau, CF/PA12 composite femoral stems: manufacturing and properties, Composites Part A, vol. 39, no. 5, pp. 796 804, 2008. [10] H. Bougherara, M. N. Bureau, M. Campbell, A. Vadean, and L. H. Yahia, Design of a biomimetic polymer-composite hip prosthesis, Journal of Biomedical Materials Research Part A, vol. 82, no. 1, pp. 27 40, 2007. [11] M. N. Bureau, H. Shen, J. F. Whitfield, et al., Osseointegration of biomimetic HA-coated composite hip implants, in Proceedings of the International Symposium on Polymeric Materials for Regenerative Medicine (PMRM 07), Boucherville, Canada, April 2007. [12] M. Campbell, M. N. Bureau, H. A. Bougherara, J. Denault, and L. H. Yahia, Biomimetic polymer composites for orthopedic implants, in Proceedings of the Annual Technical Conference (ANTEC 06), vol. 1, pp. 158 162, Charlotte, NC, USA, May 2006. [13] C. Auclair-Daigle, M. N. Bureau, J.-G. Legoux, and L. H. Yahia, Bioactive hydroxyapatite coatings on polymer composites for orthopedic implants, Journal of Biomedical Materials Research Part A, vol. 73, no. 4, pp. 398 408, 2005. [14]S.Dimitrievska,A.Petit,A.Ajji,M.N.Bureau,andL.H. Yahia, Biocompatibility of novel polymer-apatite nanocomposite fibers, Journal of Biomedical Materials Research Part A, vol. 84, no. 1, pp. 44 53, 2008. [15] M. N. Bureau, H. Shen, J. F. Whitfield, et al., Osseointegration of biomimetic HA-coated composite hip implants, in Proceedings of the 52nd Annual Meeting of the Orthopedic Research Society, Chicago, Ill, USA, March 2006. [16] M. Papini and P. Zalzal, Thirdgen.zip, International Society of Biomechanics (ISB) Finite Element Mesh Repository, Istituti Ortopedici Rizzoli. [17] G. Bergmann, F. Graichen, and A. Rohlmann, Hip joint loading during walking and running, measured in two patients, Journal of Biomechanics, vol. 26, no. 8, pp. 969 990, 1993.