Digital Tomosynthesis: Advanced Breast Cancer Imaging Technique. Max Wiedmann



Similar documents
Mammography. What is Mammography?

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

Digital Mammography Update: Design and Characteristics of Current Systems

Preparing for your Breast Tomosynthesis

X-ray (Radiography) - Bone

Patient Prep Information

X-ray (Radiography) - Chest

X-ray (Radiography) - Abdomen

Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis

X-ray (Radiography), Chest

Mammography Applications for MAMMOMAT 1000/3000 Nova

A Guide to Breast Imaging: The Latest Technology for Screening and Detecting Breast Cancer

Quality Control of Full Field Digital Mammography Units

X-Rays Benefits and Risks. Techniques that use x-rays

Personalized Breast Screening Service

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

I-Max Touch Range. PAN / CEPH / 3D digital panoramic unit. Evolutive 3 in 1 panoramic unit

Low-dose CT Imaging. Edgar Fearnow, M.D. Section Chief, Computed Tomography, Lancaster General Hospital

PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS

Radiation therapy involves using many terms you may have never heard before. Below is a list of words you could hear during your treatment.

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL

Cutting Edge Digital Radiography Technology in Daily NDT Use

Atomic and Nuclear Physics Laboratory (Physics 4780)

Surveying and QC of Stereotactic Breast Biopsy Units for ACR Accreditation

Fundamentals of Cone-Beam CT Imaging

The effects of radiation on the body can be divided into Stochastic (random) effects and deterministic or Non-stochastic effects.

X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission

Contents. X-ray and Computed Tomography. Characterization of X-rays. Production of X-rays

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

CT scanning. By Mikael Jensen & Jens E. Wilhjelm Risø National laboratory Ørsted DTU. (Ver /9/07) by M. Jensen and J. E.

for breast cancer detection

Mammomat Inspiration Mammomat Inspiration Prime

The Field. Radiologic technologists take x-rays and administer nonradioactive materials into patients' bloodstreams for diagnostic purposes.

Digital radiography conquers the veterinary world

Development of High Speed Oblique X-ray CT System for Printed Circuit Board

Patient Exposure Doses During Diagnostic Radiography

Reduce Your Risk of Breast Cancer

CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging

Feasibility Study of Neutron Dose for Real Time Image Guided. Proton Therapy: A Monte Carlo Study

PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT

Dental Radiography Core Subject. Digital Radiography

im3d S.p.A. La Ricerca fa Impresa

Dose Measurement in Mammography; What are we measuring? David E. Hintenlang, Ph.D. DABR University of Florida

Radiographic Image Production. Radiographic Image Production. Principles of Imaging Science I (RAD 119) Film, Screens, and Cassettes

CT Scan Thorax and Upper Abdomen. Respiratory Unit Patient Information Leaflet

DENTAL Cone beam 3D X-RAY SYSTEM with

5.2 ASSESSMENT OF X-RAY TUBE LEAKAGE RADIATION AND X-RAY TUBE OUTPUT TOTAL FILTRATION

X-ray Imaging Systems

Digital Mammogram National Database

Veraview IC5 HD High definition, digital imaging excellence. Thinking ahead. Focused on life.

Official reprint from UpToDate UpToDate

Radiation Exposure in X-ray and CT Examinations

CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY

NORMAL CHEST RADIOGRAPHY. Front and lateral view

BREAST CHARACTERISTICS AND DOSIMETRIC DATA IN X RAY MAMMOGRAPHY - A LARGE SAMPLE WORLDWIDE SURVEY

Breast Screening Explained. We can supply this information in other languages, in large print, on audio or in Braille.

Concepts for High-Resolution Low-Dose CT of the Breast

Automation of a CT Acquisition: A System-based User-Support. 1. Introduction. Bärbel KRATZ 1, Frank HEROLD 1, Malte KURFISS 1

PHYSICAL METHODS, INSTRUMENTS AND MEASUREMENTS Vol. III - Medical and Industrial Tomography - W.B.Gilboy

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy

Breast Density Legislation: Implications for primary care providers

CONTENT SPECIFICATIONS FOR THE FLUOROSCOPY EXAMINATION

Hologic Selenia Dimensions C-View Software Module. October 24, 2012

Data. microcat +SPECT

Digital Breast Tomosynthesis QC Requirements

Lectures about XRF (X-Ray Fluorescence)

Development of on line monitor detectors used for clinical routine in proton and ion therapy

Q.A. Collectible. Sponsored by CRCPD s Committee on Quality Assurance in Diagnostic X-Ray (H-7)

Study the Quality Assurance of Conventional X-ray Machines Using Non Invasive KV meter

Mammography. For 35+ years, screenfilm has been the gold standard for breast cancer detection

Cardiac CT for Calcium Scoring

College on Medical Physics. Digital Imaging Science and Technology to Enhance Healthcare in the Developing Countries

Industrial X-ray for Nondestructive Testing Unrestricted Siemens AG All rights reserved

ACR AAPM SIIM PRACTICE PARAMETER FOR DETERMINANTS OF IMAGE QUALITY IN DIGITAL MAMMOGRAPHY

Production of X-rays and Interactions of X-rays with Matter

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950

Solar Photovoltaic (PV) Cells

Physics testing of image detectors

Training needs for professionals in conventional radiology (radiology technicians, physicists, radiologists) joining digital radiology

Strahlenschutzbelehrung Allgemeiner Teil. Radiation Protection

.org. Osteochondroma. Solitary Osteochondroma

Mammograms & Breast Health. An Information Guide for Women U.S. DEPARTMENT OF HEALTH AND HUMAN SERVICES. Centers for Disease Control and Prevention

Breast Cancer. CSC Cancer Experience Registry Member, breast cancer

DETERMINING WHICH COLOR UV BEAD CHANGES COLORS THE FASTEST

CT: Size Specific Dose Estimate (SSDE): Why We Need Another CT Dose Index. Acknowledgements

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH

Medicare Part B. Mammograms - Updated Billing Guide for Screening and Diagnostic Tests

I SEE THE FUTURE

X-RAY IMAGING Emerging Digital Technology - CMOS Detectors

First Warning Systems, Inc.

Quality Assurance. The selection of the equipment. Equipment Specifications. Medical Exposure Directive 97/43 Euratom. Quality Assurance Programme

Proper Implementation of Industrial CT Scanning to Reduce Inspection Costs & Get to Production Faster. Jesse Garant, JG&A Metrology Center

Focused Learning Lesson Physical Science Grade Levels 9 12 PS-H-G4

A PACS-Aware DICOM Image Object

Transcription:

Digital Tomosynthesis: Advanced Breast Cancer Imaging Technique Max Wiedmann

Digital Tomosynthesis An imaging technique in which multiple X-rays of one object are take from a discrete number angles. These cross-sectional images are used to reconstruct 3-D images of the object being scanned. Tomosynthesis differs from computed tomography because the range of angles used is less than 360, which is used in CT.

The leading Cause of death for women ages 40-55. Is only behind lung and bronchus cancer in terms of number of deaths in US. Early detection of breast cancer is believed to save thousands of lives Breast Cancer

A method for detecting growths in breasts using a dedicated machine. Achieved by compressing the breast tissue to both spread it out and reduce motion blur, followed by X-ray exposure. X-rays will be absorbed to different degrees with different tissue. Bone absorbs the most while soft tissue allows the rays to pass through. Mammography

Mammography part 2 X-rays are produced using Bremsstrahlung, a process in which electrons are accelerated against an anode, causing photons to be fired off across a continuous spectrum. The rays that pass through the tissue cause photographic film to expose creating an image. A newer process, called full field digital mammography uses digital receptors.

Full Field Digital Mammography The use of a reusable digital flat panel to detect incoming X- rays. The energy from incoming photons is converted to a voltage then run through an ADC and processed. An image is generated in seconds. Digital imaging appeared later in mammography than most of radiology due to the high contrast and resolution requirement for mammograms.

Kieran Maher, 2000

Problems with Mammograms Mammograms require the breast tissue to be compressed between two plates of glass. Many women dislike the feeling, which reduces the likeliness of getting tested often. Compression causes overlapping in the breast tissue, which can obscure imaging. Mammograms typically only take 2 images at orthogonal axes. Mammograms produce false positives and false negatives. Of all biopsies taken from breasts that tested positive, only 20% came back with cancer.

Advantages of DTS Minimal pressure is needed, just enough to hold the breast in place. A lower dose of radiation is required, up to 50% reduction for dense breasts. The cost of DTS is expected to drop below the cost a of traditional mammogram. It is the only procedure that is expected to fully replace mammography.

Required Dose vs. Breast Thickness for varying anode materials Anode Material Molybdenum/Rhodium Molybdenum Tungsten/Rhodium

Mathematics Behind DTS Filtered back projection is used to reconstruct 3D structures from 2D images. This is a form of an inverse Radon Transformation. A radon transformation is an integral of some function all lines passing though the object of interest. Here, in the two dimensional we could integrate over all lines parameterized in the following way: (x(t),y(t)) = t(sin a, -cos a) + s(cos a, sin a) The resulting Radon transform would be:

Application of Math What s been done here is an integral of all line integrals in the space this object is in. In practice, there is no actual integral, rather, the function is the exponential attenuation caused by the X-rays penetrating the tissue. Now, given the functions, we want to put it back together, using an inverse Radon transformation. However, the inverse Radon transformation is very unstable when dealing with noisy data so an alternative is used: filtered back projection.

Left Mediolateral Oblique, Mammogram

Same Left Mediolateral Oblique, DTS

Mammomat Inspiration The Mammomat is a prototype developed by Siemens. Comes with complete setup (X-ray machine and computer) Fast, improves workflow. Can be combined with computer aided diagnosis (CAD), Upgradeable User friendly.

Technical Specifications: X-Ray Generator Power output - 5kW kv Range - 23kV- 35kV Exposure Time: 10 ms to 4 s (large focus) 60 ms to 6 s (small focus) Source: MAMMOMAT Inspiration - Technical Specifications, Siemens

Technical Specifications: Solid-state detector of amorphous selenium. Dimensions: 24 cm x 30 cm (9.5'' x 12'') Pixel Size: 85 µm Image matrix :2816 x 3584 (24 cm x 30 cm) 2016 x 2816 (18 cm x 24 cm) Flat Detector Source: MAMMOMAT Inspiration - Technical Specifications, Siemens

Approval Status The Mammomat Inspiration has been approved in the EU but not in the US by the FDA. Prototype work is being conducted in both the EU and the US.

Summary Digital tomosynthesis is a process used to reconstruct 3-D images of from 2-D scans. Advantages of DTS include comfort, speed, and lower radiation dosage. It may eventually replace conventional mammography as it become less expensive. Currently, it is only approved in the EU.

Sources Breastcancer.org http://www.breastcancer.org/symptoms/testing/types/ dig_tomosynth.jsp Joseph Y. Lo, Ph.D. research pages http://deckard.mc.duke.edu/~jyl/bme.html MAMMOMAT Inspiration - Technical Specifications, Siemens http://www.medical.siemens.com/ Duke Advanced Imaging Laboratory http://dailabs.duhs.duke.edu/research.html Kieran Maher Flat X-Ray Panel Receptors http://homepage.mac.com/kieranmaher/digrad/drpapers/flatpanel/ index.html

Questions 1) What are the advantages of Digital Tomosynthesis vs. conventional Mamography A. Comfort B. Lower radiation dose C. Better for dense breast tissue D. All of the above E. None of the above 2) Tomosynthesis involves which of the following: A. Application of electrodes to the skin B. Radio waves C. Images taken at multiple angles D. Consuming chemicals to show up on images E. None of the Above