American College of Radiology Stereotactic Breast Biopsy Accreditation Program



Similar documents
Surveying and QC of Stereotactic Breast Biopsy Units for ACR Accreditation

IAC Ch 41, p.1. Procedure means a stereotactically guided breast biopsy performed on a patient for diagnostic purposes.

American College of Radiology Mammography Accreditation Program

The American College of Radiology Stereotactic Breast Biopsy Accreditation Program: Frequently Asked Questions (Updated: August 24, 2015)

Annual MQSA Inspection Questions NMQAAC April 19, 2004

The American College of Radiology Breast Ultrasound Accreditation Program: Frequently Asked Questions

Update on MQSA and ACR Mammography Accreditation

Quality Control of Full Field Digital Mammography Units

MQSA, FDA Regulations, and Inspections

Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis

Breast MRI Quality Control

Q.A. Collectible. Sponsored by CRCPD s Committee on Quality Assurance in Diagnostic X-Ray (H-7)

MQSA and ACR Digital Breast Tomosynthesis Mammography Accreditation

The Mammography Quality Standards Act Final Regulations Document #1

SUBCHAPTER 22 QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS

SOP #: Revision #: Current Version Implementation Date: Page #: Page 1 of 10 Last Reviewed/Update Date: Expiration

2/28/2011. MIPPA overview and CMS requirements. CT accreditation. Today s agenda. About MIPPA. Computed Tomography

RADIOLOGY HOUSE STAFF MANUAL

D. FREQUENTLY ASKED QUESTIONS

Update on ACR Digital Mammography QC Manual

Patient Prep Information

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

Mammography. What is Mammography?

MAMMOGRAPHY GOALS AND OBJECTIVES

WHERE IN THE WORLD JILL LIPOTI?

Bon Secours St. Mary s Hospital School of Medical Imaging Course Descriptions by Semester 18 Month Program

Digital Breast Tomosynthesis QC Requirements

Introduction. Digital Mammography Detector QC FFDM. What is FFDM QC and why is it. important? What to know before you start. Eric A. Berns, Ph.D.

Q: What differentiates a diagnostic from a screening mammography procedure?

Department of Veterans Affairs VHA HANDBOOK Washington DC April 28, 2011 MAMMOGRAPHY PROGRAM PROCEDURES AND STANDARDS

Stereotactic Breast Biopsy

U.S. Bureau of Labor Statistics. Radiology Tech

ACR AAPM TECHNICAL STANDARD FOR DIAGNOSTIC MEDICAL PHYSICS PERFORMANCE MONITORING OF MAGNETIC RESONANCE IMAGING (MRI) EQUIPMENT

The Field. Radiologic technologists take x-rays and administer nonradioactive materials into patients' bloodstreams for diagnostic purposes.

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

BREAST IMAGING. Developed by the Ad Hoc Committee on Resident and Fellow Education of the Society of Breast Imaging

First floor, Main Hospital North Services provided 24/7 365 days per year

Dose Measurement in Mammography; What are we measuring? David E. Hintenlang, Ph.D. DABR University of Florida

CURRICULUM VITAE. Kalpana M. Kanal, Ph.D., DABR

Sustaining a High-Quality Breast MRI Practice

Bon Secours St. Mary s School of Medical Imaging Course Descriptions by Semester Class of CRS 101 Clinical Radiation Science 3

Prepublication Requirements

Program Conference 2016 Dana Schmitz, M. Ed., R.T.(R)

CAR Standards for Teleradiology

Mammography: Dosimetry ACMP Annual Meeting Virginia Beach Saturday, May 2, 2009 Lawrence N. Rothenberg, Ph.D. Department of Medical Physics Memorial

Radiologic Technology Program. Radiation Safety and Protection Program

Accreditation Is Coming

VI. FREQUENTLY ASKED QUESTIONS CONCERNING BREAST IMAGING AUDITS

Diagnostic Radiology. Contrast Enema 74270

The Challenge of CT Dose Records

Manual for Accreditation of Agencies for Quality Assurance of Diagnostic X-ray Equipment

QUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES. (a) Applicability. (b) Definitions

AHLA. UU. Diagnostic Imaging Services. Thomas W. Greeson Reed Smith LLP Falls Church, VA

PET Accreditation Program Requirements

Redesigning Health Insurance Benefits, Payment and Performance Improvement Programs. Pay for Performance Subcommittee Committee Meeting #3

There must be an appropriate administrative structure for each residency program.

Highmark Provider Privileging Requirements

Mammography. For 35+ years, screenfilm has been the gold standard for breast cancer detection

9. If we get "good" standards, how can we make sure they won't arbitrarily be changed by HHS in the future?

European Academy of DentoMaxilloFacial Radiology

Accreditation of diagnostic imaging services in developing countries

AZ Sint Lucas - Brugge, Belgium

Radiation Oncology Practice Accreditation Program Requirements

OUTLINE OF MAMMOGRAPHY ROTATION GOALS

Coronis 5MP Mammo. The standard of care for digital mammography

Federal Supply Schedule (FSS) 621 I Professional & Allied Healthcare Staffing Services

How To Compare Mammography To A 3D System

LOUISIANA REVISED STATUTE 37: THE LOUISIANA RADIOLOGIC TECHNOLOGIST LICENSING LAW

Illinois. Accreditation. Requirements. Medical Radiation. Technology

Recognition. Radiation Survey Objectives. Objectives. Part 1 Documentation Radiation Source Survey Objectives Radiation Detectors Techniques

Consultation. Review of the scopes of practice for registration in the profession of medical radiation technology

ACR AAPM SIIM PRACTICE PARAMETER FOR DETERMINANTS OF IMAGE QUALITY IN DIGITAL MAMMOGRAPHY

Radiologic Technology Program

Physics testing of image detectors

Education, Training, and Certification of Medical Physicist in Korea

Thyroid Biopsy Specialists An Innovative Role for Radiology Assistant

Breast Cancer Survey. GfK HealthCare. A study conducted for Siemens Communication Sector, Erlangen. January 2011

X-ray (Radiography) - Bone

Department of Veterans Affairs VA HANDBOOK 5005/77 STAFFING

Medicare Part B. Mammograms - Updated Billing Guide for Screening and Diagnostic Tests

Cabrillo College Catalog

Radiologic Technology Degree

Azienda Ospedale Annunziata Cosenza - Cosenza, Italy

Infrared Thermography Not a Useful Breast Cancer Screening Tool

Hologic Selenia Dimensions C-View Software Module. October 24, 2012

Provider Reimbursement for Women's Cancer Screening Program

Provincial Quality Management Programs for Mammography, Colonoscopy and Pathology in Ontario

- Pisa, Italy. Azienda Ospedaliero-Universitaria Di Pisa - Ospedale S. Chiara 1/6. General Information

CHAPTER 5 QC Test For Radiographic Equipment. Prepared by:- Kamarul Amin bin Abu Bakar School of Medical Imaging KLMUC

Santa Maria Annunziata Hospital / Azienda Sanitaria di Firenze

Department of Veterans Affairs VHA DIRECTIVE Veterans Health Administration Washington, DC February 8, 2011

X-ray (Radiography) - Abdomen

Transcription:

American College of Radiology Stereotactic Breast Biopsy Program ACR Breast Imaging Programs June 2003 Mammography required under MQSA 8251 facilities; 12,077 units accredited Stereotactic Breast Biopsy Voluntary 427 facilities; 435 units accredited Breast Ultrasound Voluntary 375 facilities accredited First Breast Imaging Program Fees 3-Year Additional Mammo Stereo (unit based) $1200 $1050 $900 $800 Breast Ultrasound (facility-based) $700 (BU only) $800 (BU & Bx) Stereotactic Breast Biopsy Program (SBBAP) W. Phil Evans III, M.D. Chair, Committee on Stereotactic Breast Biopsy Robert J. Pizzutiello, M.S. Chair, Subcommittee on Stereotactic Breast Biopsy Physics ACR and the American College of Surgeons (ACoS) ACR and ACoS have worked together to define qualifications for non-mqsa qualified physicians Final version approved June 1998 ACR contracts with ACoS to handle QC and image review aspect of the ACoS Stereotactic Breast Biopsy Program Currently, fewer than 10 facilities accredited through that program SBBAP Personnel Requirements Depends on Practice Setting Apply to Physicians collaborative practice independent practice Radiologic technologists Medical physicists Cover Initial training and experience inuing experience inuing education

Radiologist Responsibilities Collaborative Practice SBBAP Physician Requirements Collaborative Practice Mammography interpretation Experienced in providing recommendations for biopsy and lesion identification at time of biopsy Oversight of all QA and QC Supervision of radiologic technologist and medical physicist Initial Exp Ed Radiologist MQSA qualified 3 supervised Bx or 12 independent 3 hrs Cat 1 CME in SBB Other Physician 3 supervised Bx or 12 independent 3 hrs Cat 1 CME including triangulation Exp in post-bx management 12 SBB per yr 3 hrs Cat 1 CME in SBB per 3 yrs Ed SBBAP Physician Requirements Independent Practice Initial Exp Radiologist MQSA qualified 3 supervised Bx or 12 independent 3 hrs Cat 1 CME in SBB 15 hrs CME in breast imaging including benign & malignant disease & CBE 12 SBB per yr 3 hrs Cat 1 CME in SBB per 3 yrs; must include post-bx management Other Physician Evaluate 480 mamms/2 yrs under MQSA qualified MD 15 hrs Cat 1 CME in SBB, OR 36 Bx over last 3 yrs AND 4 hrs Cat 1 CME rad physics 3 supervised BX or 12 independent Evaluate 480 mamms/2 yrs under MQSA qualified MD 12 SBB per yr 3 hrs Cat 1 CME in SBB per 3 yrs SBBAP Physician Responsibilities Independent Practice Radiologist Mammo interpretation Patient selection including documenting correlative CBE QA including medical audit QC oversight Supervision of radiologic tech & medical physicist Post-biopsy patient management (may include referral to a surgeon on follow-up on certain lesions) Other Physician Patient selection QA including medical audit QC oversight Supervision of radiologic tech & medical physicist Post-biopsy patient management SBBAP Personnel Requirements Accredited Equipment Initial Exp Ed Radiologic Technologist ARRT registered Qualified under MQSA (including 200 mamms per 2 yrs) 3 hrs Cat A CEU in SBB 5 hands-on Bx under qualified MD or tech 12 Bx per yr 3 hrs Cat A CEU in SBB per 3 yrs Medical Physicist Licensed OR state approved OR board certified in diagnostic physics Master s degree or higher Qualified under MQSA 1 hands-on stereo survey supervised by qualified med phys 1 stereo survey per yr 3 hrs CEU in SBB physics per 3 yrs X-ray units Prone table Upright units with add-on devices Lateral arm Sampling devices Gun/needle Vacuum assisted devices ACR does not accredit Target-on-scout Large gauge needles (e.g., ABBI)

Medical Physicist s Annual QC Tests Stereotactic Unit Assembly Evaluation of Focal Spot Performance kvp Accuracy/Reproducibility Beam Quality Assessment (HVL) Exposure Reproducibility Breast Entrance Exposure, Average Glandular Dose Image Quality Evaluation Artifact Evaluation Digital Field Uniformity Localization Simulation (Gelatin Phantom) Radiologic Technologists QC Tests Mammo QC Tests Also Apply if Screen-Film Used Localization Accuracy - daily Phantom Image - weekly Hardcopy Output Quality - monthly, if app Visual Checklist - monthly Compression Force - semi-annually Repeat Analysis - semi-annually Zero Alignment Test before each pt., if app SBBAP Testing Criteria Clinical Images Required image sets Mass Calcifications Examples of a facility s best work This does not mean most difficult cases Lesion biopsied is same as seen on the mammogram Needle must be in or near lesion Clinical Images Submitted for Mass Target lesion marked on 2-view mammogram Pre-fire stereo pair (gun-needle only) Post-fire stereo pair (gun-needle & vacuum) If using vacuum-type cutting needles, show cutting side towards the lesion at the pre-tissue acquisition position (pre-biopsy) Clinical Images Submitted for Calcifications Target calcifications marked on 2-view mammogram Pre-fire stereo pair (gun-needle only) Pre-biopsy stereo pair (vacuum only) Show cutting side towards the calcifications at the pre-tissue acquisition position Specimen radiograph demonstrating calcium Specimen Radiograph Fibers Masses SBBAP Testing Criteria Dose and Phantom Dose - Must be less than 300 mrads Phantom image quality Speck Groups MAP Phantom F/S 4.0 Digital 5.0 4.0 3.5 Mini Phantom F/S 2.0 2.0 2.0 Digital 2.5

Two Types of Approved Phantoms Phantom with Dosimeter Mini Stereotactic Phantom Mini Stereotactic Breast Biopsy Phantom Nuclear Associates 18-250 Mammography Phantom RMI 156 Nuclear Associates 18-220 Place the dosimeter in the center of the phantom Phantom Images Submitted for Mini Stereotactic Phantom Mammography Phantom Four exposures to image all test objects One image with and one without the dosimeter Chest Wall Side Phantom Images Submitted for Mammography Phantom Fifth exposure with dosimeter in center of field ACR Image Reviewers Radiologists and medical physicists In full time clinical (or physics) practice Board certified Over 5 years of experience in accreditation modality Participate in formal training program

What Happens If a Facility Does Not Pass on the First Attempt? ACR Stereo Program Pass Rates 1 st Attempt (Last full year) 100 250 Attempt 1st 2nd 3rd Outcome Deficiency Fail Fail Action To Proceed 1. Take corrective action (CA) 2. REPEAT deficient test(s) 1. Submit CA to ACR for review and approval 2. REINSTATE by reapplying 1. Submit CA to ACR for review and approval 2. Participate in Scheduled On-Site Survey 3. REINSTATE by reapplying % of Final Reports Written that Pass on 1st Attempt 90 80 70 60 50 40 30 20 10 0 1996 1997 1998 1999 2000 2001 2002 225 200 175 150 125 100 75 50 25 # of Final Reports Written Facilities may appeal any negative decision Year %Initial Pass %Renewal Pass %Total Pass Total # Final Reports SBBAP Reasons For Failures 1st Attempt 2002 Diagnostic Modality Program (DMAP) 18% 10% 0% 10% 62% Stereotactic Breast Biopsy Breast Ultrasound Ultrasound Magnetic Resonance Imaging Nuclear Medicine and PET Computed Tomography Radiography/Fluroroscopy Clinical & Phantom Clinical Phantom Only Dose Only Processor The Good News! More Good News! New ACR Diagnostic Modality Program features: Less Paperwork! Streamlined Process! 10% discount for 3 or more modalities New ACR Diagnostic Modality Program: If you are applying for more than one modality, you can submit images for each at different times..for example, a month apart

The DMAP Entry Application Process It Is Still A Two-Step Application Process The application collects: Group practice information Personnel lists Attestations of CME from MDs and physicists Policy & procedure questions & answers Modality specific equipment information Testing Process Modality Specific Clinical and phantom images Quality control data Medical physicist report For Help with ACR Voluntary Programs Reston, VA line (800) 770-0145 Web site www.acr.org No password needed for accreditation info Tutorial Video Tapes Tutorial tapes are sent to a facility undergoing accreditation. Designed to walk you through the accreditation process www.acr.org

ACR Quality rol Manuals Mammography QC Manual (1990, 1992, 1994, 1999) Barium Enema QC Manual (1998) Stereotactic Breast Biopsy QC Manual (1999) MRI QC Manual (2001) Sent free to all facilities in program To purchase, call ACR Pubs: (800) 227-7762 QC forms available to anyone on website Marketing Tools ACR provides accredited facilities with a marketing tool kit that includes: Certification Mark & Decal Downloadable Ad Sample Press Release Web site listing ACR Programs Why? Improved Quality Patient Confidence Payer Confidence Educational Process Validation of quality American College of Radiology Quality Is Our Image