OPERATING INSTRUCTIONS MODEL 810 HIGH VOLTAGE POWER SUPPLY



Similar documents
PIPELINE INSPECTION COMPANY LTD. Portable Holiday Detectors. OPERATING INSTRUCTIONS SPY PORTABLE HOLIDAY DETECTORS Models 780, 785, & 790

Instructions & Safety Information Models A220-20D and A220-20L Version 2

Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver.

Advantium 2 Plus Alarm

±15 V Current-Limited Power Supply

USER INSTRUCTIONS DESCRIPTION:

BroadBand PowerShield. User Manual

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

STAGE SETTER-8. User Instructions. Elation Professional

Take-2 by Nel-Tech Labs, Inc. Installation & User Manual

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

Essential Electrical Concepts

LCD5500Z / PKP-LCD v3.x Installation Instructions

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

7 FUNCTION DIGITAL MULTIMETER

Instruction Manual. This manual covers models: 8-125E 60-18E 20-50E 80-13E 33-33E 150-7E 40-25E E 50-20E E

24.2L M.A.N. V12 Engine Module

How To Use A Cdm250 Digital Multimeter

3M Wrist Strap and Footwear Tester 740. User s Guide

Benchtop Computer Monitor Generator

Universal Wireless Effects Controller USER S GUIDE SA115

Seven function digital multimeter

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

LT SERIES User s Manual

3 WATT LED SPOTLIGHT Model No. SLM

User Manual. CFG253 3 MHz Function Generator

16/32 Channel 1U Rack Mount CCTV Power Supply

PagePac PAGEPAL V

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

OPERATING INSTRUCTIONS FOR LED-4 MULTI-SPORT TABLETOP SCOREBOARD

DC LOAD TESTING Gian Trento June 18 th, 2004

Manual Ranging MultiMeter

Load Cell Amplifier Module. Instruction Manual LCA

VK-250 WARRANTY REGISTRATION FORM

Automatic Phone-Out Home Monitoring Systems

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

Single Station Remote Alarm

Part I - Installation

User Guide. HDMI Active Cable Extender. DVI-7370c

CMD-8000 rev. A COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM

Portable Holiday Detectors

Mini-led spotlight with magnetic base

DCX300 - DCX400 - DCX600

Owner s Manual & Safety Instructions

Mini Power Bank and Charger

INSTALLATION & SERVICE MANUAL. Display Panel

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. Tower 1000/1500 VA. 120/230 Vac. su0813a

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

ER102. Emergency Crank Weather Radio Owner s Manual.

Bottom Loading Water Dispenser

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Electronic Brake Controller Hayes Brake Controller Company ENERGIZE III P/N # 81741B or ENERGIZE XPC P/N #81745 OPERATION MANUAL

RT-200 HI-TEST ROPE TESTER

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

PS 155 WIRELESS INTERCOM USER MANUAL

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

Model HPX10 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Installation, Operation & Service Manual

Periodic Verification System Model 775PVS

User's Guide Integrating Sound Level Datalogger Model

Model SRMD Setra Remote Monitoring Display

Powerware Relay-Serial Card User s Guide

Installation & User Manual

PixController, Inc. Wireless Digital PIR Sensor

INTRODUCTION. Please read this manual carefully for a through explanation of the Decimator ProRackG and its functions.

FREQUENCY RESPONSE ANALYZERS

AM/FM Component Stereo Receiver System ( ) Preparation Faxback Doc. # 18708

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

User's Guide. Integrating Sound Level Datalogger. Model Introduction

User's Manual. Research Isometric Transducer 0 to 5 grams and 0 to 50 grams

Light Meter (Foot Candles)

FUTURE CALL PICTURE CARE PHONE MODEL: FC-1007 USER MANUAL

AutoRanging Digital MultiMeter

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

Table of Contents TO OPERATE THE 12.0 VOLT POWER PACK: THIS OPERATES ONLY OFF THE UNIT S RECHARGEABLE BATTERY, NOT OFF YOUR VEHICLE S BATTERY.

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

AM/FM Emergency Weather Radio/Light With Hand Crank Back-Up Power

APG-XT APG-HPD. Operating Manual. Internal APG (Analog Programming) Interface for XT/HPD Series Programmable DC Power Supply

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Liquid Carbon Balanced Transportable Headphone Amplifier. Cavalli audio. Copyright Cavalli Audio, LLC All Rights Reserved

Unattended Answering Device Instruction Manual

TOA 900 SERIES II MIXER POWER AMPLIFIER

Global Water Instrumentation, Inc.

i410/i1010 AC/DC Current Clamp

Water Leak Detection System

PEDAL POWER. User s Manual

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

DC POWER SUPPLY ALIMENTATION C.C.

For Models #6-5001, #6-7501, # & #10-12K1

ATS Overhead Table Shelf System INSTRUCTION MANUAL

12-Volt Negative Ground Installation Instructions

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC

Transcription:

OPERATING INSTRUCTIONS MODEL 810 HIGH VOLTAGE POWER SUPPLY

Introduction The Model 810 High Voltage Power Supply is a self-contained unit that produces a variable high voltage output at low current levels. It can operate from line voltages of 100, 110, 220 or 240 Volts by an operated line voltage selector switch. Its maximum output is 10,000 Volts D.C. and either polarity may be selected. OUTPUT current is limited to 100 microamperes by an internal 100 Megohm limiting resistor. A calibrated 3 digit LED numeric readout plus coarse and fine controls enable the user to precisely and accurately set the high voltage output to the desired level. Illuminated status indicators display the mode and polarity selected and indicate the presence or absence of high voltage at the output terminal. Equipment Description Controls All controls for operating the power supply are located on the front panel of the unit. Main AC Power ON/OFF This self-latching (push-on-push-off) switch controls the AC power input to the unit. When depressed, the AC power will be ON and the front panel indicator lamps will be illuminated. High Voltages Controls This group of controls is used to select the output voltage range (HI or LO), the output polarity, High Voltage ON/OFF and to set the output voltage level. 1.2.1.2.1 Range Select (HI/LO) This single button is used to select the range of the high voltage output. When the button is out, the unit is in the LO RANGE mode which limits the maximum output to ± 2KV. When the button is pushed in, HI RANGE, the maximum output is ±10KV. 1.2.1.2.2 High Voltage Polarity and ON/OFF Select Controls This group of three (3) interlocked, self-latching buttons provides for turning the High Voltage Power Supply ON or OFF and determining the polarity of its output. The polarity buttons are dual function since they select the polarity of the Voltage and they turn the High Voltage Supply on. The High Voltage Supply is turned off by depressing the center OFF button. Since these three (3) buttons are interlocked, depressing any one (1) button will release the one (1) that was previously depressed. Further, only one (1) button should be depressed at a time. High Voltage COARSE and FINE Adjust These two controls adjust the level of the voltage output. This voltage will be zero (0) with both controls fully counterclockwise and increases as each control is rotated clockwise. As its name indicates, the COARSE adjust control is used to set the high voltage level close to the desired level. The FINE adjust control range is approximately 600 Volts; thus, if this control is set to its mid

position (12 o clock) before the COARSE control is set, it will allow the output level to be adjusted by approximately ±300 Volts about the voltage set by the COARSE control. Indicators The power supply contains five (5) point source indicators which indicate the Mode, Polarity and High Voltage ON/OFF status. It also contains a 3 digit numeric indicator which displays the precise level of the output voltage. Point Source Indicators Voltage Range Two (2) indicators are provided to indicate which of the two (2) voltage modes the unit has been set for. The GREEN indicator will be on when the unit is in the LO Voltage (0 to 2KV) mode while the AMBER indicator will be on when the HI Voltage mode has been selected. 1.2.2.1.2 High Voltage ON This single RED indicator will be illuminated when the high voltage power has been turned on and the high voltage level controls have been turned from zero (0) setting. It is a signal to the operator that high voltage may be present depending on the setting of the high voltage COARSE and FINE adjust controls. 1.2.2.1.3 Polarity Mode Two (2) indicators are provided to show which polarity has been selected. An illuminated GREEN light indicates that the output will be Positive relative to system ground while AMBER indicates that the output will be Negative. Numeric High Voltage OUTPUT Level Indicator This readout is a 3-digit display which provides the operator with a direct indication of the high voltage output level. In the LO Voltage mode (GREEN LO(V) indicator on), the readout indicates the voltage directly in VOLTS the HI Voltage mode (AMBER HI(KV) indicator on), a decimal point will appear on the display and the voltage will be displayed in KILOVOLTS. Thus, in the HI Voltage mode, a display of 9.83 indicates a voltage of 9.83 kilovolts. The display also indicates the polarity of the charging voltage by the insertion of a + or to the left of the most significant digit. In the LO (0 to 2KV) voltage mode, the readout is capable of displaying a maximum level of 1,999 Volts. If the operator sets the voltage to a level above this maximum, the readout will blank out, indicating an overscale condition. This is normal and the readout will not be damaged by settings above the ±1,999 Volts. If it is desired to test above ±1,999 Volts, the HIGH voltage mode should be used and the proper readout will be obtained. 2.0 OPERATION Before turning on the AC power, depress the HV OFF button and rotate the High Voltage ADJUST controls so that they are both fully counterclockwise.

2.1 AC Power ON Turn on the AC power by pushing the AC POWER ON button in. When in the ON position, the point source and numeric indicators will illuminate. 2.2 HI/LO Voltage Select Select the desired operating voltage range by placing the high voltage HI/LO switch in the LO position (button out) for outputs up to ±2KV or in the HI position (button in) for outputs from zero to 10KV. The range indicators above the range select button will display the range selected. 2.3 Polarity Selection Select the desired polarity by pushing the proper polarity button. The polarity status lights will indicate the polarity selected. If the polarity is changed when the high voltage output is active, the unit will automatically switch from one polarity to the new one chosen. The H.V. ON indicator will go out for about two (2) seconds while the transition is being made. When a polarity is chosen, the H.V. OFF button will release automatically. This indicates that the H.V. output has been enabled and that a high voltage output will be produced when the H.V. adjust controls are rotated clockwise from their fully counterclockwise position. 2.4 High Voltage OFF To disable the High Voltage output, depress the H.V. OFF button. This action turns off the high voltage portion of the supply and reduces the H.V. output to zero (0). The High Voltage ON indicator will go off when the H.V. OFF button is depressed. 2.5 High Voltage Level Adjustment Rotate the FINE adjust control clockwise until the pointer is in the twelve o clock (12:00) position. Rotate the COARSE adjust control clockwise until the approximate desired voltage level is indicated on the VOLTAGE readout. Now re-adjust the FINE control to trim the voltage reading to the final level. NOTE: A high voltage output and indication will be produced by rotating the Level Adjust controls only if a polarity has first been selected. No output will be indicated or produced in the H.V. OFF button is depressed. 2.6 High Voltage Output Jack and Ground Terminal The high voltage output of the supply is provided via a high voltage OUTPUT jack located in the upper right hand corner of the front panel. The BLACK terminal post directly below the high voltage OUTPUT jack is the ground reference for the high voltage output. 2.6.1 Current Output Capability The current output of the supply is limited to 100 microamperes by an internally located plug-in 100- megohm resistor. This resistor is connected in series with the output and is located between the

internal High Voltage source and the H.V. OUTPUT connector. Refer to section 3.0 for alteration of the value of this limiting resistor. 2.6 2 OUTPUT Electrode and EXTENSION CABLE The power supply is furnished with a five (5) foot High Voltage cable that plugs into the high voltage OUTPUT jack. CAUTION: Although the output current of the supply itself is limited, potentially dangerous conditions can occur if capacitive loads are charged using the supply s output. External high voltage capacitors can store large amounts of energy. This energy can be released at high current levels that can be extremely dangerous. Care should be exercised when the supply is used as a high voltage source to charge such external capacitive loads. 3.0 MAINTENANCE AND MISCELLANEOUS INFORMATION 3.1 OUTPUT CURRENT Limiting Resistor The power supply is shipped with an internally located 100 Megohm series resistor that limits the short circuit current to 100 microamperes. This resistor is located in the upper right hand corner of the unit, as shown in Figure 3-1. To gain access to this resistor, the top cover of the unit must be removed. To do this, first unplug the AC line cord, then remove the eight (8) screws that secure the front and rear bezels to the case (there are four (4) screws securing each bezel to the case). Slide the bezels away, then pull the top cover gently upward and away from the case (Figure 3.1). Unplug the 100 Megohm resistor and replace it with the new value. A LIMITING Resistor value of less than 100 Megohm is not recommended since it may overload the supply when the output is shorted. After replacing the 100 Megohm resistor with the new value, replace the cover and front and rear bezels. 3.2 Line Voltage Section The Model 810 has a line voltage selector located on the rear panel. Rotate the switch using a coin or flat blade screwdriver either 100, 110, 220 or 240 Volt operation. Use a ¾ Amp, 3 AG Slo-Blo fuse for 100 or 110 Volts and 3/8 Amp, 3 AG Slo-Blo fuse for 220 or 240 Volts. 3.3 AC Line Fuse Replacement Should the AC Fuse fail, replace it with a ¾ AMP Slo-Blo type fuse (type 3 AG or EQUIVALENT). The cause for the fuse failure should be determined before the fuse is replaced. For 230 Volt operation use a 3/8 AMP Slo-Blo fuse. 3.4 Meter Calibration Each unit is tested and calibrated at the factory to insure the accuracy of the Voltage readout. The Meter CAL adjustment is provided for this purpose. Under normal circumstances, this adjustment should not be altered by the User.

3.5 Cautionary Note When servicing this equipment, always start by disconnecting its power cord from the AC line. Further, if the unit is operated with the cover removed (i.e., during servicing), extreme care should be exercised due to the high voltages which may be present. Figure 3-1

WARRANTY Electro-Tech Systems, Inc. warrants its equipment, accessories and parts of its manufacture to be and remain free from defects in material and workmanship for a period of one (1) year from date of invoice and will, at the discretion of Seller, either replace or repair without charge, F.O.B. Glenside, similar equipment or a similar part to replace any equipment or a part of its manufacture which, within the above stated time, is proved to have been defective t the time it was sold. All equipment claimed defective must be returned properly identified to the Seller (or presented to one of its agents for inspection). This warranty only applies to equipment operated in accordance with Seller s operating instructions. Seller s warranty with respect to those parts of the equipment which are purchased from other manufacturers shall be subject only to that manufacturer s warranty. The Seller s liability hereunder is expressly limited to repairing or replacing any parts of the equipment manufactured by the manufacturer and found to have been defective. The Seller shall not be liable for damage resulting or claimed to result from any cause whatsoever. This warranty becomes null and void should the equipment, or any part thereof, be abused or modified by the customer of if used in any application other than that for which it was intended. This warranty to replace or repair is the only warranty, either expressed or implied or provided by law, and is in lieu of all other warranties and the Seller denies any other promise, guarantee, or warranty with respect to the equipment or accessories and, in particular, as to its or their suitability for the purposes of the buyer or its or their performance, either quantitatively or qualitatively or as to the products which it may produce and the buyer is expected to expressly waive rights to any warranty other than that stated herein. ETS must be notified before any equipment is returned for repair. ETS will issue an RMA (Return Material Authorization) number for return of equipment. Equipment should be shipped prepaid and insured in the original packaging. If the original packaging is not available, the equipment must be packed in a sufficiently large box (or boxes if applicable) of double wall construction with substantial packing around all sides. The RMA number, description of the problem along with the contact name and telephone number must be included in formal paperwork and enclosed with the instrument. Round trip freight and related charges are the owner s responsibility. WARNING WOODEN CRATES MUST NOT BE USED. PACKAGING OF DELICATE INSTRUMENTS IN WOODEN CRATES SUBSTANTIALLY INCREASES THE CONTENT S SUSCEPTIBILITY TO SHOCK DAMAGE. DO NOT PLACE INSTRUMENTS OR ACCESSORIES INSIDE OTHER INSTRUMENTS OR CHAMBERS. ELECTRO-TECH SYSTEMS, INC. WILL NOT ASSUME RESPONSIBILITY FOR ADDITIONAL COST OR REPAIR DUE TO DAMAGE INCURRED DURING SHIPMENT AS A RESULT OF POOR PACKAGING.