Sentinel TM. Efficient, portable fluid purification protecting hydraulic systems 24/7.



Similar documents
Parker Tracking System Fast. Easy. Exact. Driving operational efficiency through an increase in the speed, timing, and accuracy of asset management.

IQAN Software Studios Software Tools. Electronic Control Systems

Find more information on this product on our homepage. NEW! Now with improved ZDMC2. Adsorption Dryer Concept WVM

A clean start is essential Cleanliness Services

RENEWABLE ENERGY - HYDROPOWER

QDS6 Auxiliary Valves

Compact EHA. Electro-Hydraulic Actuators for high power density applications

Breathable Compressed Air

PVS Series - Models 185, 600, 1200, 1800 and 2700

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

Mobile Hydraulic Pumps T6G, T67G, T6ZC. Denison Vane Technology, fixed displacement

The Parker Service Master Plus. Innovative measurement technology with greater possibilities

European Research Council

Parflange 50 WorkCenter. Efficient production machine for O-Lok and Triple-Lok connections

BIS CEMLA Roundtable on Fiscal Policy, public debt management and government bond markets: issues for central banks

Hi-Pro Ball Valve for High Performance Process Isolation

Axioma Risk Monitor Global Developed Markets 29 June 2016

Portable Purification Systems Models PVS 185, 600, 1200, 1800, 2700

Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION

European Research Council

ENTERING THE EU BORDERS & VISAS THE SCHENGEN AREA OF FREE MOVEMENT. EU Schengen States. Non-Schengen EU States. Non-EU Schengen States.

Where People Search for Jobs:

Parker Tube Fabricating Equipment. Catalog TFE

Catalogue Power Conversion System for Energy Storage. 890GT-B Product Brochure

Accuracy counts! SENSORS WITH ANALOG OUTPUT

World Consumer Income and Expenditure Patterns

Retirement Readiness. OECD/IOPS GLOBAL FORUM ON PRIVATE PENSIONS - Sydney Nov 2-3

Payments to Overseas banks Things to be aware of

Cisco 2-Port OC-3/STM-1 Packet-over-SONET Port Adapter

Building on +60 GW of experience. Track record as of 31 December 2013

41 T Korea, Rep T Netherlands T Japan E Bulgaria T Argentina T Czech Republic T Greece 50.

FH Studies Collaboration Lecturers at the European Society of Atherosclerosis Congress Pre- and Post- Event Questionnaires

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

SURVEY ON THE TRAINING OF GENERAL CARE NURSES IN THE EUROPEAN UNION. The current minimum training requirements for general care nurses

Parker Angle Seat Valves. PA Series, 2/2 Way, NC or NO 3/8" to 2 1/2" BSP, 16 Bar

Cisco Conference Connection

Pneumatic Solutions. The Food Industry

Supplies 1. Toner cartridges. Printing. Using color. Paper handling. Maintenance. Troubleshooting. Administration. Index

The Par-Gel Filter Water Removal Filter Elements

Sulfuric Acid 2013 World Market Outlook and Forecast up to 2017

CO2 BASED MOTOR VEHICLE TAXES IN THE EU IN 2015

DSV Air & Sea, Inc. Aerospace Sector. DSV Air & Sea, Inc. Aerospace

The big pay turnaround: Eurozone recovering, emerging markets falter in 2015

LuxeMbOurG Trading CenT re LisT Annex 1 to the special terms and conditions for securities transactions Valid as from 1 september 2011

FedEx Electronic Trade Documents User Guide for FedEx Ship Manager TM Software

ERMInE Database. Presentation by Nils Flatabø SINTEF Energy Research. ERMInE Workshop 2 - Northern Europe Oslo, 1. November 2006

Global Trends in Online Shopping A Nielsen Global Consumer Report. June 2010

Brochure More information from

Coreless Spin-On Filters. 12AS/50AS Series

THE WORLD S LEADING CAR DESIGN MAGAZINE

How To Get A New Phone System For Your Business

Global AML Resource Map Over 2000 AML professionals

THE CISCO CRM COMMUNICATIONS CONNECTOR GIVES EMPLOYEES SECURE, RELIABLE, AND CONVENIENT ACCESS TO CUSTOMER INFORMATION

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

OVERVIEW OF PURCHASE AND TAX INCENTIVES FOR ELECTRIC VEHICLES IN THE EU

Finnish foreign trade 2014 Figures and diagrams FINNISH CUSTOMS Statistics 1

Supported Payment Methods

QuickSpecs. HP Wireless Keyboard and Mouse. Models

Sentinel Portable Purification System

October Trust in Advertising. a global Nielsen

BT Premium Event Call and Web Rate Card

Supported Payment Methods

Guide. Axis Webinar. User guide

Your oil can be saved!! Even when water is mixed

SuccessFactors Employee Central: Cloud Core HR Introduction, Overview, and Roadmap Update Joachim Foerderer, SAP AG

Global Network Access International Access Rates

RTS, RS, RX and AXEM Series

Get the benefits of Norgren s unique range of Online services

NetFlow Feature Acceleration

Implementing the cooperation mechanisms of the RES directive current status and open questions

Appendix 1: Full Country Rankings

MERCER S COMPENSATION ANALYSIS AND REVIEW SYSTEM AN ONLINE TOOL DESIGNED TO TAKE THE WORK OUT OF YOUR COMPENSATION REVIEW PROCESS

SESAR. Luftfahrttechnologie - Auftaktveranstaltung zum 7. EU-Forschungsrahmenprogramm Wien, 4 Dezember 2006

Agilent 4338B Milliohm Meter

SunGard Best Practice Guide

History Future cooperation...steinbeis

It looks like your regular telephone.

GfK PURCHASING POWER INTERNATIONAL

Cisco IOS Public-Key Infrastructure: Deployment Benefits and Features

E-Seminar. Financial Management Internet Business Solution Seminar

Our patent and trade mark attorneys are here to help you protect and profit from your ideas, making sure they re working every bit as hard as you do.

Logix5000 Clock Update Tool V /13/2005 Copyright 2005 Rockwell Automation Inc., All Rights Reserved. 1

OCTOBER Russell-Parametric Cross-Sectional Volatility (CrossVol ) Indexes Construction and Methodology

CISCO IP PHONE SERVICES SOFTWARE DEVELOPMENT KIT (SDK)

Microsoft survey on enterprise social use and perceptions

Report on Government Information Requests

360 o View of. Global Immigration

CISCO METRO ETHERNET SERVICES AND SUPPORT

Field Safety Notice Urgent Medical Device Correction C Cloudy Appearance and Potential Tears on System Drapes

Your Business Connection

NITROGEN CHARGING KIT type PCM 11.2 E 04-11

ThermoSorb Desiccant Dryers

Agilent 87421A/87422A Power Supply

CISCO CONTENT SWITCHING MODULE SOFTWARE VERSION 4.1(1) FOR THE CISCO CATALYST 6500 SERIES SWITCH AND CISCO 7600 SERIES ROUTER

Parker Solutions for Table Top Sterilizers. Solenoid Valves and Accessories

Guide. Axis Webinar User Guide

Product Summary. KLIMA 1 Catalogue KLIMA 2 Catalogue FILTER Catalogue. The art of handling air. Special leaflet SP/1/EN/7

GE Grid Solutions. Providing solutions that keep the world energized Press Conference Call Presentation November 12, Imagination at work.

Transcription:

Sentinel TM Efficient, portable fluid purification protecting hydraulic systems 24/7.

Portable fluid purification. Protect cost of ownership. The Sentinel is designed to stand guard over your hydraulic systems 24/7 increasing productivity by eliminating moisture in the oil. Water is the second most destructive contaminant typically 200ppm water can reduce bearing life by 48% or more. Moisture accelerates the aging of hydraulic fluids, reducing oil lifetime by typically more than 50%. Fact 1 High moisture content in system oil will reduce life time Fact 2 The potential for expensive downtime will be increased as a direct result of moisture ingress Fact 3 The Sentinel, incorporated into a planned maintenance programme, will reduce costs and increase machine efficiency 2

Portable, versatile and alive with technology, the Sentinel takes fluid purification to a new level of dependability and efficiency. Bringing together Parker s unrivalled filtration expertise and industry know-how in one affordable and compact unit, the Sentinel stretches maintenance budgets and boosts productivity, by streamlining the dehydration process and reducing costly, unscheduled downtime. Compact, lightweight and tough, the Sentinel is engineered to deliver outstanding results in every environment whenever, and wherever there s an issue with water-contaminated hydraulic oils and transformer fluids. Moisture in oil shortens machinery life plain and simple. The Sentinel helps put a stop to that by lowering the cost of ownership through the introduction of pre scheduled maintenance using the Sentinel in 3 key ways. 1 By having a pre-scheduled maintenance programme in place. Thinking about condition monitoring of multiple machines, the Sentinel s portability and easy connection makes it ideal where there is a planned maintenance schedule and it can be wheeled from vehicle to vehicle and operated overnight. Power Generation Electrohydraulic Control Systems The Sentinel has already started to add value and reduce maintenance downtime. 2 Having the Sentinel as a permanent installation but working when the moisture exceeds a pre-set level. Connected as a permanent oil condition clean-up unit, for example connected to ship thruster systems - the Sentinel operates as a babysitter, monitoring moisture levels and detecting increases at which point it activates. One solution fits all A uniquely versatile design means that samples can be taken directly from a hydraulic reservoir, barrel, vehicle or oil storage tank, making the Sentinel ideal for applications ranging from renewable energy, marine and offshore to manufacturing, mobile, agriculture, military and ground handling. With a laser detection particle counter available as an option, the Sentinel is totally self-contained. So you won t need extra equipment or face problems with equipment compatibility. Now dehydration is simpler, and more efficient all round. 3 Having Marine Propulsion, Steering Systems, Thrusters Operating the Sentinel round the clock keeps moisture ingress under control and a thing of the past. the Sentinel permanently connected to a system to continuously condition the oil. Working in accordance with a programmed configuration, the Sentinel will provide a reliable and effective condition monitoring partner ideally used in industrial applications such as CNC hydraulics, steel pressing equipment and vacuum forming equipment. Industrial Lubrication Systems Process Controls The heavier the industrial application, the better the Sentinel seems able to perform. 3

The Sentinel Fast, efficient, portable. Feature-rich and cost-efficient. With the Sentinel, extra productivity comes as standard. Packed with advanced features, and engineered to the highest quality, no other dehydration equipment gives you more for your money. Proven vacuum dehydration technology The Sentinel uses vacuum dehydration technology, so that only clean, dry oil re-enters the reservoir system via the outlet port. On board data display and storage Test data is displayed instantly on an IQAN MD3 screen, for real time observation. Stored data can be downloaded straight to a PC or laptop for analysis via a standard USB connection. Rapid detection and removal Fast detection of water contaminants is provided through embedded % RH moisture, as well as optional solid particle contamination detector. The high visibility digital display provides easy assessment of fluid condition, and shows measured parameters including moisture sensor readings as a % of relative humidity. Fluid and pressure control The Sentinel operates at flow rates of 12 litres /min, with a maximum online operating pressure of 0-4 Bar. Long life automatic operation In Sentinel mode, the system will automatically turn on, measure water content and run dehydration cycling if necessary, shutting itself off once fluid reaches the % RH set point. (Electrical requirements are 380-420 VAC, 3Ph, 60Hz for other voltages consult Parker.) 4

Recommendation Principles of Operation The Sentinel is most recommended for: Systems with moisture level typically <2% RH. Systems up to 3.000 litres of oil content. The Digi water in oil test kit is recommended if the moisture level is not known before measuring. Fully compliant Desiccant Air Breather High Level Switch Low Level Switch Vacuum Gauge Low Watt Density Heater Vacuum Chamber Coalescing Filter Overflow Tank Inlet Flow High Level Overflow Reservoir As a Parker product, the Sentinel is specified to meet the most exacting international industry standards Flow Direction CE Marked EC Declaration of Conformity Machinery Directive Oil Discharge Pump Dry Sealed Vacuum Pump High Level Condensate Condensate Tank Vacuum Outlet Quick connection Model 40CN-2 Absolute Filter Oil Lubricator Condensate Drain Connecting the Sentinel is quick and reliable. Side mounted fluid connectors are secured with screw fittings: 22L metric for outlet and inlet and water drain connector size 15L metric. Parker can supply dedicated hoses and fittings for use with most hydraulic and hydrocarbon fluids. Hardwearing and lightweight The tough enclosure and fully isolated impact-resistant panel provide excellent protection in the most demanding of applications, combined with a lightweight construction, making the Sentinel the ideal diagnostic service tool. Contaminated fluid is drawn through the Sentinel circuit by vacuum. The fluid is subjected to optimum vacuum, temperature and surface area to reduce the boiling point of water and convert water to water vapour. Optimum temperature is achieved with a low watt density heater. Maximum surface area is accomplished by passing the fluid through a unique diffusing column. The fluid is protected from excessive heat by circulation for a fixed time period. When the pre-set time period is realized, the fluid discharges through high efficiency filtration to the main system reservoir. Water vapour that has been extracted from the system is exposed to a series of coalescers to eliminate any carryover oil vapour in the exhaust stream. The process repeats until the desired steady state condition is achieved. 5

Proven technology, trusted to perform. The Sentinel combines Parker innovation, quality and reliability in one complete solution Precision engineered by Parker, and trusted by leading companies around the world, Sentinel technology is proven to perform in a huge variety of applications, even under the most demanding conditions. Construction and mining The ideal solution to condition hydraulic fluid. Power generation Essential control of water contamination in lubrication fluids. Automotive manufacturing The primary diagnostic and service instrument for predictive water monitoring programmes. Aviation Ease, light weight and portability are key for water removal and monitoring in aviation flushing units and simulators. Paper and pulp Providing accuracy and speed for routine maintenance and emergency dehydration. Marine Vital quality control for shipboard hydraulic, steering system and bow thrusters. 6

The operator can customise set points for various applications within their facility. IQAN System One of the highlights of the new Sentinel unit is the addition of Parker s IQAN system. The IQAN is an electronic PLC interface that controls many of the operating functions on the Sentinel. With IQAN, the operator can customize set points for various applications within their facility. Some of the user defined set points are: moisture high limit moisture set point (low limit) temperature vacuum purge cycle auto condensate drain energy conserving features Three modes of operation 1. Standard Conventional purifiers require that the reservoir fluid be at 70 C before efficient water removal occurs. This could take hours if the ambient temperatures are low and the reservoir volumes are large. Standard mode allows for less power consumption by drawing the fluid through the unit in a unique cyclic method. The fluid is drawn into the unit and held while heat and vacuum act on it to remove water. Every two minutes the fluid is discharged and the process repeats, conserving power that otherwise would be necessary to bring the entire main system reservoir to the required 70 C. 2. Sentinel Sentinel mode acts the same as standard mode other than it samples by drawing in fluid from the reservoir and testing the water saturation point. If the level is less than the desired set point, the system will hibernate until the next sampling point. The minimum time between sampling is 20 minutes and the maximum is 240 hrs. (10 days) 3. Sample Once started, three batches of hydraulic fluid will be drawn into the system where overall moisture level and temperature are averaged and displayed on the IQAN screen. Sentinel mode will maintain constant dedicated vigilance to control water saturation in fluid while providing energy and labour savings. 7

Straight forward to operate The Sentinel is designed to operate in three simple modes, for maximum efficiency, longevity and ease of use: Standard mode When water is detected, the contaminated oil is drawn into the Sentinel for recirculating to achieve required % RH level of moisture. Sentinel mode System automatically turns on, to measure water content and run dehydration cycling if necessary, shutting itself off once fluid reaches the % RH set point. Sample mode Indicates which operational mode is required. Calculates the % RH of water within the system. How the Sentinel works Contaminated oil is drawn into the portable purification system by a vacuum of of -0.6 bar. The oil passes through the in-line, low watt density heater, where it is heated to the optimum temperature (70 C), before entering the distillation column where it is exposed to the vacuum through the use of a dedicated dispersal element. This increases the exposed surface area of the oil and converts the water to a vapour, which is then drawn through the condenser by the vacuum pump. The vapour returns to water and drops into the condensate holding tank, to be drained off at a later stage. The water-free oil falls to the bottom of the vacuum chamber and is passed through a final particulate removal filter by a heavy duty lube oil pump, before re-entering the reservoir/system via the outlet port. 8

Performance Potential Contaminant Solid particulate Water Air/Gases Sentinel Performance ISO Cleanliness Code 14/13/10 Attainable Removes 100% of free water, 90% of dissolved water Removes 100% of free air and gases, 90% of dissolved air and gases The Sentinel core components The Sentinel design and build represents the best in Parker technology and manufacturing. Typical Performance Tank Size Run Time Fluid Type Water Content 200 litre test drum 16 hours Hydraulic Start: 7,000+ ppm (1%) Saturation pt: 5,000 ppm Stop: 200 ppm (0.005%) Fig1. The Sentinel features a Parker IQAN electronic MD3 PLC interface controlling many of the Sentinel operating functions. Fig2. Contaminated system oil is drawn into the Sentinel by a vacuum pump generating a vacuum of -0.8 bar. Fig3. Once heated to an optimum 70ºC the oil enters a distillation column designed with a dedicated dispersal element. Fig4. A Parker MS150 moisture sensor provides continuous monitoring of moisture content in the oil to determine moisture levels and operation. 9

Technical data The Sentinel specification Feature Principle of operation Recalibration and servicing Working pressure Working viscosity Flow range Fluid connection interface inlet & outlet: Fluid working condition Ambient storage temperature for unit Operating temperature for unit Operating humidity range Fluid operating temperature (Oil) Moisture sensor linear scale within the range Computer compatibility connection Seals Vacuum pump type Particle filter type Heater type Power requirement Noise level at standard operation Certification Weight IPDR - Particle Detector IQAN MD3 Memory size FPS - Fluid Property Sensor Specification Vacuum dehydrator Recommended every 12 months 0 4 bar (0-60 psi) 1-400 cst 12 l/min 5GPM 22L metric +70ºC at 0.8 bar 40ºC to +80ºC; 40ºF to +176ºF 30ºC to +80ºC; 22ºF to +176ºF 5%RH to 100%RH +5ºC to +80ºC; +41ºF to +176ºF 5%RH to 100%RH Unit to be connected to a laptop computer via USB port Fluorocarbon Dry sealed vacuum pump 5 micron iprotect element 6KW low - density heater 400VAC, 3P, 50Hz 60 dba IP54 rating (unit open) CE Marked EC Declaration of Conformity Machinery Directive 190 kg Contact Parker 80,000 logs Contact Parker 10

Sentinel dimensions IQAN Control Main Power 620 mm 495 mm Hydraulic Outlet 4 Point Tie Down Rings 1130 mm Vacuum Exhaust Hydraulic Inlet (22L metric) Electrical Connection Port Water Drain (15L metric) How to order Part number 1/2 NPT Cabin Drain Fork Truck Support Pocket Description Note: Dimensions and weights are approximate and are for reference only. 945274 Standard unit Optional accessories - ACC6JH002 Service Kit (Triceptor element, Coalescer element, Filter element, Vacuum Pump Oil) - ACC6JH003 - Vacuum Pump Oil (1 LITRE) - MS1504 - Moisture Sensor Water in Oil Maintain and protect your equipment, whilst eliminating damage caused by water in your oil. The DIGI Water in Oil Test Kit provides state of the art, digital analysis and gives fast, accurate results for easy monitoring of trends. Prevent corrosion, cavitation or failure of your machinery by detecting water in oil, before any damage occurs. Minimise instability of additive packages and damaging microbe growth by monitoring your oil. Fully portable for use on-board or in the field, test cells are extremely robust, durable and easy to use. Ordering Information FGK17032PA: Low Range DIGI Water Kit FGK2101PA: EasySHIP Water in Oil Reagent Pack (50) Range (LR): 0.02-1%, 100-3000ppm, 0-10% Test Time: 3 minutes Battery Life: Five years (10,000 tests) When excessive moisture in the hydraulic oil demands an alternative Parker solution, the answer is a PVS The maximum flow for the PVS 2700 model is 170 l/min and the PVS 600 model shown above is 38 l/min. Specify a PVS alternative system when oil volumes for water purification are greater. Reduce the catastrophic results of water contamination be eliminating water from the hydraulic system by using one of the PVS Series Portable Purification Systems. Available in several models, the principle of the PVS is to draw water contaminated fluid out of a system then remove the water content and return the clean fluid to the reservoir. 11

Parker Worldwide Europe, Middle East, Africa AE United Arab Emirates, Dubai Tel: +971 4 8127100 parker.me@parker.com AT Austria, Wiener Neustadt Tel: +43 (0)2622 23501-0 parker.austria@parker.com AT Eastern Europe, Wiener Neustadt Tel: +43 (0)2622 23501 900 parker.easteurope@parker.com AZ Azerbaijan, Baku Tel: +994 50 2233 458 parker.azerbaijan@parker.com BE/LU Belgium, Nivelles Tel: +32 (0)67 280 900 parker.belgium@parker.com BG Bulgaria, Sofia Tel: +359 2 980 1344 parker.bulgaria@parker.com BY Belarus, Minsk Tel: +48 (0)22 573 24 00 parker.poland@parker.com CH Switzerland, Etoy Tel: +41 (0)21 821 87 00 parker.switzerland@parker.com CZ Czech Republic, Klecany Tel: +420 284 083 111 parker.czechrepublic@parker.com DE Germany, Kaarst Tel: +49 (0)2131 4016 0 parker.germany@parker.com DK Denmark, Ballerup Tel: +45 43 56 04 00 parker.denmark@parker.com ES Spain, Madrid Tel: +34 902 330 001 parker.spain@parker.com FI Finland, Vantaa Tel: +358 (0)20 753 2500 parker.finland@parker.com FR France, Contamine s/arve Tel: +33 (0)4 50 25 80 25 parker.france@parker.com GR Greece, Athens Tel: +30 210 933 6450 parker.greece@parker.com HU Hungary, Budaörs Tel: +36 23 885 470 parker.hungary@parker.com IE Ireland, Dublin Tel: +353 (0)1 466 6370 parker.ireland@parker.com IT Italy, Corsico (MI) Tel: +39 02 45 19 21 parker.italy@parker.com KZ Kazakhstan, Almaty Tel: +7 7273 561 000 parker.easteurope@parker.com NL The Netherlands, Oldenzaal Tel: +31 (0)541 585 000 parker.nl@parker.com NO Norway, Asker Tel: +47 66 75 34 00 parker.norway@parker.com PL Poland, Warsaw Tel: +48 (0)22 573 24 00 parker.poland@parker.com PT Portugal, Leca da Palmeira Tel: +351 22 999 7360 parker.portugal@parker.com RO Romania, Bucharest Tel: +40 21 252 1382 parker.romania@parker.com RU Russia, Moscow Tel: +7 495 645-2156 parker.russia@parker.com SE Sweden, Spånga Tel: +46 (0)8 59 79 50 00 parker.sweden@parker.com SK Slovakia, Banská Bystrica Tel: +421 484 162 252 parker.slovakia@parker.com SL Slovenia, Novo Mesto Tel: +386 7 337 6650 parker.slovenia@parker.com TR Turkey, Istanbul Tel: +90 216 4997081 parker.turkey@parker.com UA Ukraine, Kiev Tel: +48 (0)22 573 24 00 parker.poland@parker.com UK United Kingdom, Warwick Tel: +44 (0)1926 317 878 parker.uk@parker.com ZA South Africa, Kempton Park Tel: +27 (0)11 961 0700 parker.southafrica@parker.com North America CA Canada, Milton, Ontario Tel: +1 905 693 3000 US USA, Cleveland Tel: +1 216 896 3000 Asia Pacific AU Australia, Castle Hill Tel: +61 (0)2-9634 7777 CN China, Shanghai Tel: +86 21 2899 5000 HK Hong Kong Tel: +852 2428 8008 IN India, Mumbai Tel: +91 22 6513 7081-85 JP Japan, Tokyo Tel: +81 (0)3 6408 3901 KR South Korea, Seoul Tel: +82 2 559 0400 MY Malaysia, Shah Alam Tel: +60 3 7849 0800 NZ New Zealand, Mt Wellington Tel: +64 9 574 1744 SG Singapore Tel: +65 6887 6300 TH Thailand, Bangkok Tel: +662 186 7000 TW Taiwan, Taipei Tel: +886 2 2298 8987 South America AR Argentina, Buenos Aires Tel: +54 3327 44 4129 BR Brazil, Sao Jose dos Campos Tel: +55 800 727 5374 CL Chile, Santiago Tel: +56 2 623 1216 MX Mexico, Toluca Tel: +52 72 2275 4200 European Product Information Centre Free phone: 00 800 27 27 5374 (from AT, BE, CH, CZ, DE, DK, EE, ES, FI, FR, IE, IL, IS, IT, LU, MT, NL, NO, PL, PT, RU, SE, SK, UK, ZA) 2014 Parker Hannifin Corporation. All rights reserved. Bulletin FDCB601UK 06/2014 Parker Hannifin Hydraulic Filter Division Europe Email: conmoninfo@parker.com www.parker.com/hfde Your local authorized Parker distributor