Pressure Tank Gauge Module



Similar documents
Digital inductive conductivity transmitter

Submersion/Insertion Toroidal Sensor

ATL Fuel Level Sender Probes

Toroidal Conductivity Sensor

API Marine. BMS Presentation. Ballast Measurement Systems

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

SELECTION, APPLICATION AND MAINTENANCE

SELECTION, APPLICATION & MAINTENANCE

VOYAGER 570G. 744A Sprayer Control

AIR LINE VALVES AND GAUGES

How To Use A Flowmeter

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

MPX-Series Diesel Engine Shut Down Valves (Manual Reset / Air Pressure and Manual Closure Options)

Plastic tube flowmeters Series PT/PS

The Unique Accelabar Flow Meter

How To Replace A Reverse Osmosis Water Tank

Installation Instructions

Pressure calibration equipment

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Double-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP. Feed Water Connector 1. 1/2" FIP x 1/2" MIP x 1/4" OD 2. 3.

SIMPLAIR PIPING TOOL

MVX-Series Diesel Engine Air Shut Down Valves

Many Products...One Source

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

SELECTION, APPLICATION & MAINTENANCE

Stainless Steel Single and Dual Circulation Kits

SELECTION, APPLICATION AND MAINTENANCE

Assembly instructions VOSS quick connect system 246 NX

Operators manual Basic water heater

CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP

Submersion/Insertion Toroidal Sensor

BLUE RIBBON CORP. BC001 Birdcage Installation Manual

Hydraulic Control Solutions

Approval of this procedure is provided by signatory indicated in the approval block at the footer of Page #1, for and on behalf of Jabiru Pty. Ltd.

HARTING Ethernet Cabling 4-poles Overview

Subminiature Load Cell Model 8417

Power Cube Open Source Ecology Page 1. Power Cube. Version 4

TECHNICAL DATA. Dry 122a. November 12, 2013

NFPA31FuelOilPiping 1 Revised

Steam System Best Practices Condensate System Piping

Series 510 Submersible Level Transmitters

Model 43AP Pneumatic Controller, Style B

TMC CableReady Connectors For Jacketed Metal Clad Cable TMC For Non-Hazardous Locations

MÁQUINAS AGRÍCOLAS JACTO S.A. EDITION

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)

Auto-belay Cable Replacement Process

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

BBWX1 Satellite Weather Receiver. Installation and Maintenance Guide

K17.12 Door closers K17. Doors

AMX300 DirectConnect Mixing Valve Kits

Powers Controls TH 192 S Single Temperature Room Thermostat

A99B Series Temperature Sensors

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

STABITHERM INSTALLATION & SERVICE BOOKLET

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Installing a Probe. Typical Installation

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Instruction Manual. Cable Splicing. Models , HDF1, HDF SS1

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Installation Instructions S

MVX-Series Diesel Engine Shut Down Valves (Cable Operated Closure/Integral Reset Lever Types)

Select Radiators Installation Guide

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Dissolved Oxygen Sensors

INSTALLATION INSTRUCTIONS

Series 6000 Torque measured metal bellow coupling

PBX Series Quick Fit Connector Bimetallic Steam Traps

Copper Meter Resetters

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

Combination ph/redox (ORP) Sensors

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

1/2 NPTM mm Nose cone fitting Ideal for clean liquids

ENAiKOON ultrasonic fuel-level sensor

Reaction Torque Sensor

Your safety and the safety of others are very important.

Machine needle shut-off nozzle type HP

Watts Pure Water Systems

Open channel & partially filled pipe Ultrasonic flow meters

Oxy-Fuel Gas Welding. Given a functional oxy-fuel gas unit, instruction and demonstration of use, each student will be able to:

Drayton Digistat +2RF/+3RF

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Thread and End Connection

Replacing Displacers with Guided Wave Radar

THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE

Jay R. Smith Mfg. Co.

Transcription:

Pressure Tank Gauge Module Introduction The E-Plex 318PFTG series can be used in a wide variety of applications. The same tank sender can be used for diesel fuel, fresh water, grey water, or black water tanks. The tank gauge in its standard version can measure fluid up to a maximum depth of 2m and measures pressure of fluid in a tank to a high resolution. Tank shape has no effect on the accuracy of the pressure tank gauge, which makes it useful in applications where the tank shape is irregular. The tank gauge can be used in multiple configurations, depending on the construction of the tank whether it is plastic or metallic. The E-Logic software allows for accurate calibration by building a tank curve table during the initial fill process. A table can also be precalculated if the tank dimensions are known. Key Features Measures tank contents by sensing pressure. Can be used for diesel, fresh water, grey water or black water. Available in top entry and direct mount versions. Robust stainless steel sensor. Top entry version is adjustable for different depth tanks.

Installation Direct Mount The housing assembly screws directly into a 1/4 BSP opening on the side or bottom of the tank. If mounted to the side, it should be located near the bottom of the tank so as to be exposed to the maximum level of fluid in the tank. For serviceability, a valve is recommended in-line to allow for removal without emptying the tank. A union is available to aid installation and removal. NB. The sensor is supplied with a dust cap that must be removed prior to installation. The 318PFTG interface unit may be mounted onto any horizontal or vertical flat surface near the sensor. Sender should be mounted at same level as any takeoff (or slightly higher to allow a reserve if required). The sender should be fitted into a suitable ball valve so the sender can be removed for service. Allow for exp expansion Expansion: Allow at least 50mm at the top of tank for expansion and to prevent over filling. Breather: Avoid U bend in the breather as any trapped fluid will affect reading (see next page). A Max level of fluid to be measured 5m Minimum level that Sender may be calibrated to read zero Mechanical Fitting Of Sender This unit MUST only be fitted to a threaded ¼ BSP female bush. It is important that a shut off valve is fitted in-line to the unit to facilitate removal, should this become necessary in the future. Before assembly ensure all threads are clean and free of grease then assemble using a good quality jointing compound. 1/4 BSP coupler supplied with direct mount version. Ensure that the shut off valve is open BEFORE tightening the unit into the shut off valve, so as not to damage the sensor due to overpressure.

Installation Top Mount The stainless steel sensor drops into the tank from the top. Due to the flexibility of the tube it can be placed in any conveniently accessible location on the tank then allowed to sink and flex around bends or obstructions in the shape of the tank. The length of flexible pipe to the pressure sensor can be adjusted by loosening the cable gland at the top of the tank mount. This also allows the tank mount to rotate when installing the sender. Ensure that the cable gland is tightened after installation to prevent leaks. The 318PFTG interface unit may be screwed to any horizontal or vertical flat surface near the sensor. Sender should be located at same level as fuel takeoff (or slightly higher to allow a reserve). Tank Breathers The E-Plex Tank Sensor uses a sensitive pressure transducer to measure the depth of fluid. It will measure empty when the fluid reaches the bottom of the sender. The tank must have a correctly installed breather to allow the tank sender to work correctly. Any water trapped in the breather pipe will effect the measurement and introduce inaccuracy. If the tank can be filled or emptied at high speed the breather pipe must be sized to suit. Correctly installed breather - no water trap in the breather pipe. Expansion: Allow at least 50mm at the top of tank for expansion and to prevent over filling. Breather: Avoid U bend in the breather as any trapped fuid will affect reading (see right). exp Allow for expansion. Max level of fluid to be measured 5m. Minimum level that Sender may be calibrated to read zero. Incorrectly installed breather - water trap in the breather pipe. 1 NPT version Ordering code: EP-MON-318PFTG-N-01 1.25 BSPP version Ordering code: EP-MON-318PFTG-N-02

41mm [1.61 ] 45mm [1.77 ] 75mm [2.95 ] 30mm [1.18 ] 318PFTG Calibration The tank sender is supplied with a base calibration level of 1mm = 1 count for water. A 300mm deep parallel sided tank would require a table in the module calibration page so that 0 counts = 0% and 300 counts = 100%. If the sender is being used in diesel fuel allowance needs to be made for the differing densities of diesel and water. Diesel is approximately 0.85 times the density of water, so 300mm of fuel would read 255 counts and the table would need to be changed to suit. Technical Specifications Description Specifications Maximum Pressure 2 bar (0 to 5m fluid depth) Connectors EP3 Sensor Assembly Stainless steel Tube Type PUR vented cable PVC type I top, 1 NPT outer thread Cap Style PVC type II top, 1.25 BSPP outer thread PVC type III top, 1.5 NPT outer thread Direct mount, G 1/4 BSP DIN 3852 Operating Temperature -20 C to 60 C Storage Temperature -40 C to 85 C Operating Humidity 5% to 95% (non condensing) E-Plex LEN 9 107mm [4.21 ] ø 4.2mm [0.17 ] For M4 fixings or #6 woodsrews 118mm [4.65 ]

Ordering Codes Description Ordering Code Direct mount version 1/4 BSP with couple EP3-MON-318PFTG-N-DM 1 NPT version EP3-MON-318PFTG-N-01 1.25 BSPP version EP3-MON-318PFTG-N-02 1.5 NPT version EP3-MON-318PFTG-N-03 Powering Systems - Empowering Designers 52 54 Riverside, Medway City Estate, Rochester, Kent ME2 4DP tel: +44 (0)1634 778704 Fax: +44 (0)1634 290773 email: sales@e-plex.co web: www.e-plex.co Important Notice: E-Plex Ltd. (E-Plex) reserves the right to make changes to or discontinue any product or service identified in this publication without notice. E-Plex advises its customers to obtain the latest version of the relevant information to verify, before placing any orders, that the information being relied upon is current. E-Plex assumes no responsibility for infringement of patents or rights of others based on E-Plex applications assistance or product specifications since E-Plex does not possess full access concerning the use or application of customers products. E-Plex also assumes no responsibility for customers product designs.