TEXAS RESIDENTIAL CONSTRUCTION COMMISSION (TRCC) PERFORMANCE STANDARDS FOR FOUNDATIONS AND MAJOR STRUCTURAL COMPONENTS



Similar documents
Lighthouse Engineering, L.L.C.

The Impact of Market Demands on Residential Post-Tensioned Foundation Design: An Ethical Dilemma

National Home Builder - Name Wednesday, August 20, 2014 Regional Customer Care Manager 1234 Main Street Houston, Texas 77067

3142. Short title This Chapter shall be known and may be cited as the "New Home Warranty Act." Acts 1986, No. 676, 1.

Structural Foundation System

symptoms of a faulty foundation

5006 Cherry Ridge Road Richmond, Texas LIMITATIONS AND DISCLAIMERS

WARRANTIES AND PERFORMANCE STANDARDS T A B L E O F C O N T E N T S General Provisions Introduction Warranties Effective Date of Warranties Exclusive

USE OF MICROPILES IN TEXAS BRIDGES. by John G. Delphia, P.E. TxDOT Bridge Division Geotechnical Branch

ENGINEERED FOUNDATIONS. Department of Public Works Jeff Hill, PE

QUICK REFERENCE GUIDE // TEXAS NEW HOME WARRANTY // OCTOBER Check for the most recent edition of this document

Foundation Repair Permit - Residential and Commercial

Lighthouse Engineering, L.L.C.

PERFORMANCE GUIDELINES

SAMPLE REPORT. Convention regarding directions: Front faces the street, left and right are as seen from the street facing the house.

INSPECTION PROPERTY ADDRESS: Fort Bend County, Texas

PERIODIC STRUCTURAL INSPECTION OF EXISTING BUILDINGS GUIDELINES FOR STRUCTURAL ENGINEERS

C O N S U L T A N T S RESUME

Foundation Evaluation Report for PROPERTY ADDRESS Houston, Texas August 30, Prepared for:

FLOOD HAZARD MANAGEMENT SPECIFIC PLAN GUIDELINES

A RESIDENTIAL PROPERTY LOCATED AT xxxxxxxxxxxxxx, PASADENA, TX 77505

How To Build A House In Texas

your new home 10 year structural warranty. TX_5309_031114

Development Services Department Building Permit & Inspection Services Shed and Garage Construction Guide for Detached and Semi-Detached Dwellings

HEDDERMAN ENGINEERING, INC. Office , Fax

Lighthouse Engineering, L.L.C.

Metropolitan Builders Association Masonry & Concrete Standard

October 30, Mr. & Mrs. Daniel Vick 101 Southwind Cove Benton, AR. Report of Findings, Structural Investigation, Benton, Arkansas, Dear Mr.

A Solid Foundation Solution for Homeowners. from. Our products are made with 90% Recycled Material Down. Right. Solid. GREEN.

How To Install An Overhead Sewer

Engineered, Time-Tested Foundation Repairs for Settlement in Residential and Light Commercial Structures. The Leading Edge.

Investigation of Foundation Failure. Step 1 - Data Collection. Investigation Steps

Foundation Repair Fundamentals And how they relate to the Real Estate Industry in the DFW Area

Inspection of the exterior found a tree in the back yard and a tree in the front yard within influential distance from the residence foundation.

A guide to preventing structural damage

Ron Miedema Cement Contractor 1865 Pine Ridge ~ Jenison, MI 49428

%&'!&()%&' &*! "!!& &+,! "#+ + &- ' &!&.'(%&'! %&%+ &+&&*-/" ' &+&+ '-0

Inspection Report. Mr. John Homebuyer. Property Address: 123 Main Street Houston TX Front View. EDP Consulting Engineers, PLLC

PROFESSIONAL ENGINEERING INSPECTIONS, INC.

City of Cincinnati Pamphlet Residential Lease Option Contract

ATLAS RESISTANCE Pier Foundation Systems

Presenters. The Ups and Downs of Home Elevations 4/29/2016. Hazard Mitigation Grant (HMA) Programs

Structural Audit of Buildings

GEORGE J. CAMBOURAKIS, P.E., C. ENG. PRESIDENT & CHIEF STRUCTURAL ENGINEER

For purposes of this chapter the following words and phrases shall have the meanings ascribed herein unless the context clearly indicates otherwise:

EL LAGO BUILDING DEPARTMENT PERMIT ISSUANCE PROCEDURES As of February 20, 2013

Residential Deck Safety, Construction, and Repair

COMMON FOR ARCHITECTS AND ENGINEERS Excerpts from HB 2284, 82 nd R

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

FOR. by The Structural Committee of The Foundation Performance Association Houston, Texas. Document # FPA-SC-06-0

For a period of one (1) year beginning on the Closing ( Warranty Period ), Builder warrants to Purchaser, and only Purchaser, that:

Residential Building Permit Process

DESIGNING STRUCTURES IN EXPANSIVE CLAY

DRAFT/SAMPLE RESIDENTIAL WARRANTY CORPORATION THE TRCC ADDENDUM TO 10 YEAR WARRANTY FOR NEW HOMES THE LIMITED WARRANTY PRESENTS

Use of Watermarks for Discerning Hurricane-Induced Flood Levels. Erik L. Nelson, Ph.D., P.E., M. ASCE 1

PROMULGATED BY THE TEXAS ASSOCIATION OF BUILDERS (TAB) EXPRESS LIMITED HOME WARRANTY. (Street Address and City)

Designed and Engineered to Perform

Elevating Your House. Introduction CHAPTER 5

Five Star Realty Group LLC 1

October 6, (B) the vantage point from which the crawl space was inspected; and

Chapter 9 Remedial Measures

BRIDGE RESTORATION AND LANDSLIDE CORRECTION USING STRUCTURAL PIER AND GRADE BEAM

Texas Building Pros Foundation Repair Services

Sisal Composite Ltd. Apparel 4 Ltd. JM Knit Ltd. Natun Para, Hemayetpur, Savar, Dhaka-1340 ( N, E)

Penfield Pavilion Status Report

Bureau Veritas Contact Information

Using Slab-on-Ground Elevation Measurements in Residential Foundation Engineering Performance Evaluations. By R. Michael Gray, P.E.

City of Mandeville. Guidelines for Construction and Development

City of Morro Bay Building Division 955 Shasta Ave., Morro Bay, CA ,

Cold Weather Concrete Practices

dpd 316 Seattle Permits Tip Subject-to-Field-Inspection (STFI) Permits Projects that Qualify as STFI

GOOD NEWS BUT NOT ALWAYS

CONSTRUCTION RISK MANAGEMENT. Suggestions for Managing Residential Construction Defect Risk after the Texas Residential Construction Commission Act

BUYER S GUIDE TO SLAB-ON-GROUND FOUNDATIONS

FORENSIC INVESTIGATION QUESTIONNAIRE

Baton Rouge Foundation Repair

Exterior Elevated Elements Inspection Guidelines

NEW HOUSING AND HOME IMPROVEMENT WARRANTIES Minn. Stat , et. seq. Winter 2004

SWIMMING POOL / SPA PLAN REVIEW CHECKLIST

C I T Y O F P E A R S A L L

Available online at I-SEEC Proceeding - Science and Engineering (2013)

123 Frontage Rd. Fort Worth Inspected Address City Zip Code

Which Way Is It Moving? Guidelines for Diagnosing Heave, Subsidence and Settlement

4.3 Cisterns and Rain Barrels

MULTI-FAMILY, COMMERCIAL, INDUSTRIAL, AS GOVERNED BY THE BC BUILDING CODE PART 3

Criteria for the Inspection of and the Assessment of Residential Slab-on-Ground Foundations

Lighthouse Engineering, L.L.C.

Contents. Finding A Builder...9. Subcontractors...9 Quotes And Estimates Owner Builders...11 Once Decided On A Builder...11

GUIDELINES FOR THE EVALUATION OF FOUNDATION MOVEMENT FOR RESIDENTIAL AND OTHER LOW-RISE BUILDINGS

The Stabilizer TM. Benefits. Supplemental support system for sagging beams and floor joists within a crawl space

Transcription:

TEXAS RESIDENTIAL CONSTRUCTION COMMISSION (TRCC) PERFORMANCE STANDARDS FOR FOUNDATIONS AND MAJOR STRUCTURAL COMPONENTS ROBERT F. PIERRY, JR., P.E. President Roger Bullivant of Texas, Inc. State Bar of Texas RESIDENTIAL REAL ESTATE CONSTRUCTION LAW February 9, 2006 - Dallas February 23, 2006 - Austin CHAPTER 3.2

Texas Residential Construction Commission (TRCC) Performance Standards for Foundations and Major Structural Components Robert F. Pierry, Jr., P.E. President Roger Bullivant of Texas, Inc. February 2006 Robert F. Pierry, Jr., P.E. Licensed Professional Engineer NCEES Record No. 11703 Licensed P.E. in 10 states, including Texas Education - B.S. in Engineering (Civil), Duke University, 1976 Engineering Experience - 27 Years Foundation Underpinning - 23 Years Heavy and Highway - 4 Years Construction Experience - 29 Years Small Diameter Piling - 23 Years Heavy and Highway Construction - 6 Years Professional Memberships/Affiliates American Society of Civil Engineers Chairman: Subcommittee to Develop Guidelines for the Evaluation and Repair of Residential Foundations Foundation Engineers Associations (2000 & 2001 President) National Society of Professional Engineers Texas Society of Professional Engineers National Federation of Independent Business (Guardian Member) Deep Foundations Institute Subchapter A. General Provisions Issues related to Foundations: Definition of Original Construction Elevations ( 304.1(c)(13)) Elevations taken prior to completion maintained in builder s file Includes porches and garages that are part of foundation Must take at least one elevation per 100 sq. ft. If not taken, presumed to be level +/- ¾. Repairs per 3 rd party inspector s recommendations and consistent with the Code or performance standard ( 304.2(a)(2)) 1

Subchapter A. General Provisions Issues related to foundations (cont d.): Exceptions and exclusions ( 304.2(b)(1)) Alterations to the grade of the soil, unless directed by builder (D) Extreme weather conditions (F) Change in underground water table (I) Erosion or accretion of soils (J) Excessive loads (O) No actual physical damage ( 304.2(b)(2)) Subchapter A. General Provisions Exceptions and exclusions (cont d) Failure to comply with homeowner s responsibilities ( 304.2.(c)) General maintenance, including maintaining drainage (1) Landscaping planting (3) Preventing further damage (6) Subchapter A. General Provisions Issues Related to Foundations (cont d) Warranty of Habitability ( 304.3(f)(2)) Complies with performance standards (A) Safe, sanitary & fit to inhabit (B) 2

Subchapter D. Performance Standards for Foundations and Major Structural Components ( 304.100) Slabs (a) Evaluate using Guidelines for the Evaluation and Repair of Residential Foundations (ASCE Guidelines) (1) with the following criteria: Overall deflection less than L/360 with not more than one associated symptoms of distress (A) Tilt less than 1% resulting in observable physical damage (B). Remedial measures to be based on Section of the ASCE Guidelines (2). Subchapter D. Performance Standards for Foundations and Major Structural Components ( 304.100) Other Structural Components (b) Floor over pier and beam (1) Overall deflection must not exceed L/360 and cause actual physical damage (A) Remedial measures based on Section 7 of the ASCE Guidelines Structural Components (2) Shall not crack, bow, become distorted or deteriorate, such that it compromises structural integrity or structural system performance of the home and results in actual physical damage (A) Remediation includes repair, replacement or reinforcement to restore structural integrity or performance Subchapter D. Performance Standards for Foundations and Major Structural Components ( 304.100) Other Structural Components (b) (continued) Deflected Structural Components (3) Shall not deflect more than ratios allowed by Code Remediation includes repair, replacement or reinforcement to restore structural integrity or performance Damaged Structural Components (4) Shall not compromise structural integrity or performance Remediation includes repair, replacement or reinforcement to restore structural integrity or performance 3

Subchapter D. Performance Standards for Foundations and Major Structural Components ( 304.100) Other Structural Components (b) (continued) Separated Structural Components (5) Shall not separate more than ¾ or such that it compromises structural integrity or performance Remediation includes repair, reinforcement or replacement to re-establish the connection and to restore structural integrity or performance Non-performing Structural Components (6) Components shall perform function per Code If not, builder shall take such action to make the component perform per Code What are the ASCE Guidelines? Developed by a sub-committee of the Texas Section of the American Society of Civil Engineers 2½ year all volunteer effort (monthly all day meetings) 17 Professional Engineers from across Texas on the sub-committee Approved by an Oversight Committee and adopted by the Texas Section, ASCE Generally non-mandatory language ( should and may vs. shall ). Available for downloading at: www.texasce.org What are the Issues? Is the Major Structural Defect definition gone? Not Really Actual Physical Damage remains ( 304.2(b)(2)) Failure is replaced with performance standards Unsafe, unsanitary and otherwise unlivable remains under the Warranty of Habitability ( 304.3(f)) but... The Warranty of Habitability applies in addition to the Structural Components Warranty 4

What are the Issues? Deflection and Tilt How are deflection and tilt measured? Will 3 rd party inspectors measure them accurately and consistently? Will all parties understand these measurements? How do deflection and tilt affect the structure? How much is too much? Deflection Slope and Tilt 5

Deflection and Tilt Deflection causes cracking Deflection and Tilt Tilt generally does not cause cracking. What are the Issues? How reasonable are the deflection and tilt standards? Deflection is reasonable, provided it is measured properly Based analogous IRC deflection limit Causes noticeable cracking in the foundation and finishes 6

What are the issues? How reasonable are the deflection and tilt standards? One-percent (1%) tilt is also reasonable, but the requirement for actual physical damage is too lenient Tilt generally doesn t cause cracking Safety may be an issue in some cases One Percent Tilt (to scale) Deflection and Tilt Sometimes tilt becomes a safety issue 7

What are the issues? Will 3 rd - Party Inspectors measure tilt and deflection accurately? Inspector training to date has focused on the process, not technical matters If original construction elevations are not available, tilt and deflection calculations become much more difficult and less definitive due to the assumption that the slab was constructed level +/- ¾ What are the issues? Timing of remedial measures The ASCE Guidelines suggest that nonstructural measures are often appropriate as a first step, with a monitoring period Generally a good idea, but may not be necessary in some cases Causes delay in final resolution, but should be allowed if recommended by 3 rd Party Inspector Questions? 8