Summary of Lighting Regulations City of Toronto, 2011



Similar documents
8. EXTERIOR SITE LIGHTING

Why is lighting in the workplace important?

COMMONLY USED RESIDENTIAL BUILDING CODES

CITY OF TORONTO. BY-LAW No

28.0 Development Permit Area #2 (Neighbourhood District)

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

OUTDOOR LIGHTING REGULATIONS

Gardiner Gateway Special Sign District. Public and Stakeholder Consultation

Design and Assessment of Exterior Lighting Schemes

Lighting (Illumination) in Warehouses

Number of Sides Required to Have a Handrail

AEDG Implementation Recommendations: Interior Lighting Sample Layouts for Office Buildings

68 & 70 Charles Street East & 628, 634, 636 & 638 Church Street- Zoning Amendment Application - Preliminary Report

LIGHTING IN THE WORKPLACE

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

* Any required illumination shall be arranged so that the failure of any single lighting unit shall not leave any area in darkness.

Outdoor Advertising. Policy and Guidelines. CITY OF DAREBIN 350 High Street, Preston 3072 Telephone January 2001

ACCESS AUDIT OF WESTPORT HOUSE

Introduction. Electronic Message Centers (EMC s) ISA International Sign Association A Summary Report on EMC Brightness Levels

The Contribution of Street Lighting to Light Pollution

Walking and Working Surface Checklist:

Workplace Health, Safety & Welfare

50 Bloor Street West Zoning Amendment Application - Preliminary Report

Director, Community Planning, Toronto and East York District STE 27 OZ & STE 27 RH

Lighting at Work. A Health and Safety Guideline for Your Workplace. The benefits of proper lighting. Human factors

THE REGIONAL MUNICIPALITY OF NIAGARA BY-LAW NO SIGN BY-LAW

4 LIGHTING DESIGN CONSIDERATIONS. 4.1 The Lighting Design (and Redesign) Process. 4.2 Lighting Quantity Setting Criterion Illumination Levels

FUTURE LAND USE ELEMENT

STREET LIGHTING CONSTRUCTION DESIGN CRITERIA

Tab III: HOUSING DESIGN CRITERIA


Shaping Whanganui. Have your say, korero mai

DOSSIER EN m CONCISE DESCRIPTION OF THE STANDARD. 2nd edition, june 2012

Exterior Lighting for Energy Savings, Security, and Safety

DEPLOSUN REFLECTORS. Carrer dels Vergós, Barcelona Spain Tel: (+34) Fx: (+34)

A Guide to Energy Efficient and Cost Effective Lighting

WELCOME PROPOSALS FOR PENTAVIA RETAIL PARK WELCOME TO OUR EXHIBITION WHICH SETS OUT OUR PLANS TO DEVELOP THE PENTAVIA RETAIL PARK SITE.

New Ontario Building Code Highlights

BOROUGH OF OAKLAND COUNTY OF BERGEN STATE OF NEW JERSEY ORDINANCE 13-CODE-685

COMMUNITY APPEARANCE STANDARDS

WHITEHALL COMMERCIAL OVERLAY DISTRICT.

STAFF REPORT. December 20, North District Community Council. Director of Community Planning - North

SCHEDULE 16 TO THE SPECIAL USE ZONE. Shown on the planning scheme map as SUZ16. BALLARAT RAILWAY STATION PRECINCT. Purpose

Stow Lighting Advisory Subcommittee Terminology Guide

AUSTRALIAN HUMAN RIGHTS COMMISSION NOTICE OF DECISION ON APPLICATION FOR TEMPORARY EXEMPTIONS: AUSTRALASIAN RAILWAY ASSOCIATION

Lemnis public lighting BETTER VISIBILITY WITH LESS ENERGY

Outdoor Workplace Lighting according to CIE S 015:2005 / pren

City of Riverside Building & Safety Division Phone: (951)

Schedule B. Schedule B. Commercial and Industrial Areas. 1 Permitted Signs The following signs shall be permitted in Commercial and Industrial Areas:

SAFETY SIGNAGE IN TECHNOLOGY CLASSROOMS

Measuring Reflectance

De Beers Canada Inc. OP 050 SLIPS, TRIPS, FALLS AND PEDESTRIAN SAFETY - SURFACE

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

MODEL LIGHTING ORDINANCE (MLO)

I N T E R N A T I O N A L R E S I D E N T I A L CO D E

Appendix "B" - Development Checklist

design Mario Cucinella MAXIWOODY

Vestibule Case Study. Vestibule Requirement Intent [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, , ]

1.1 The application property is an extended two-storey semi-detached house fronting Bedale Road. The side garden adjoins a link road to Wydale Road.

SECTION 5 RESIDENTIAL R1 ZONE

Barrie Primary Care Campus

Building Regulations (Northern Ireland) Department of Finance and Personnel protection from impact.

3655 Kingston Rd - Official Plan and Zoning By-law Amendment Applications - Preliminary Report

City of Auburn Americans with Disabilities Act (ADA) Transition Plan for Curb Ramps, Sidewalks, and Pedestrian Signals ADA TRANSITION PLAN

Council Policy for New Telecommunication Facilities

Common ADA Errors and Omissions in New Construction and Alterations

Agenda Itent Dear Mayor and Members of Council:

DECISION/DIRECTION NOTE

Measuring Light. 1 Executive Summary Luminance Illuminance Luminous Efficiency Summary... 4

FIRE SAFETY INSPECTION REPORT

The GE Advantage. All of our municipal lighting solutions come complete with GE service and support every step of the way. Discovery & Design

Lighting Requirements

County of San Diego, Planning & Development Services SECOND DWELLING UNIT

DRAFT DRAFT East Baton Rouge City-Parish Design Levels. Purpose and Intent. Design Levels Defined

Rufus Block 19. Project # DRB Recommendation Meeting #1 May 21, 2013

Outdoor Advertising Policy. Revised December Strategic Planning CD8994 Outdoor Advertising Policy Part 1 Last Amended: 14/12/2015 Page 1 of 14

Lighting Control in the Office Space

space types - design briefs

ORDINANCE NO THE CITY COUNCIL OF ALEXANDRIA HEREBY ORDAINS:

GTA Cordon Count Program

Ordinance No. 14 Series of 2012 RECITALS

Prior to submission of drawings for building permit, the architectural control process will be undertaken for the developer and/or builders.

Toronto and East York Community Council. Director, Community Planning, Toronto and East York District STE 14 OZ and STE 14 RH

23.1 RENEWABLE ENERGY

PROFFER STATEMENT REZONING TLZM LEEGATE November 1, 2013

EAST LINDSEY DISTRICT COUNCIL ~ RESIDENTIAL CARAVAN SITES CONDITIONS OF SITE LICENCE

Welcome to the AccessibilityOnline Webinar Series. A collaborative program between the National Network of ADA Centers and the. U.S.

Industrial Suburban District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

MAGNA PARK Extension. Report. DHL SUPPLY CHAIN: External Lighting Strategy. June

Open Office Plan. Function and Orientation. Space Characteristics. Material Properties Gregory Wolfe 2004 Senior Thesis Lighting / Electrical

1. REPORT CONTEXT Description of the development (include all of the following that are known at the time of the application):

Issue ID Description No. of Credits Available. Mandatory Elements Storage of Non-recyclable Waste and Recyclable Household Waste

How To Develop A Local Industry Zone

Y7230A CO 2 Alarm System

Better Vision with LED lights

SOLAR ENERGY FACILITIES ZONING AMENDMENTS

Glossop Design & Place Making Strategy

Class 6a ~ Beam Advertising and Advertising Using Similar Sources of Illumination

Guidance Note on the Need for Planning Permission for the Development of Existing Houses and Flats (effective from 6 February 2012)

1. STATEMENT OF INTENT

Transcription:

Summary of Lighting Regulations City of Toronto, 2011 Peter D. Hiscocks Toronto Chapter, Royal Astronomical Society of Canada phiscock@ee.ryerson.ca October 18, 2011 Contents 1 Introduction 1 2 Property Standards, Chapter 629 of the Municipal code 1 3 Green Development Standard 2 3.1 Low Rise Non-Residential..................................... 2 3.2 Low-Rise Residential........................................ 3 3.3 Mid to High Rise (4 storeys or greater, all uses).......................... 3 4 Bird Friendly Development Guidelines 3 5 City of Toronto Accessibility Design Guidelines 3 6 City of Toronto, Sign Bylaw, No. 196-2010 4 1 Introduction This document summarizes existing regulations related to lighting, in the City of Toronto. Comments are given as footnotes. All quotations have been abbreviated to focus on passages relevant to the issue of light pollution. Refer to the original document for the complete wording. 2 Property Standards, Chapter 629 of the Municipal code http://www.toronto.ca/legdocs/municode/1184_629.pdf Lighting regulations begin on page 36. A. Adequate artificial light required to maintain the level of illumination shall be provided at all times 1. B. Interior Lighting 2. C. For parking lots, walkways, stairs, porches, verandas, loading docks, ramps or other similar areas, a minimum level of illumination of 10 lux (0.90 foot-candle) at ground or tread level and at angles and intersections at changes of level where there are stairs or ramps. [Added 2008-04-29 by By-law No. 349-2008] 3 D. Interior and exterior lighting fixtures and lamps shall be installed and maintained so that the work, operations or activities normally carried out in or about any part of the property can be undertaken in safety and without undue eye strain. 1 Adequate is not defined. 2 Generally not relevant to the issue of light pollution, see original document. 3 This is a very high level, considering that sidewalks are illuminated to about 3 lux. Furthermore, specifying 10 lux as a minimum means that the average and peak illuminances must be larger. Nonetheless, it is possible to establish light trespass and glare recommendations that are consistent with this requirement. The lamps would have to be focussed on the target, be shielded from view, and be limited to within the property boundary.

3 Green Development Standard 3.1 Low Rise Non-Residential http://www.toronto.ca/planning/environment/pdf/lr_nonres_tech.pdf 1. All exterior light fixtures should be efficient while providing minimum illumination levels sufficient for personal safety and security. Safety and security lighting should minimize glare and/or light trespass. Refer to the Illuminating Engineering Society of North America (IESNA) Recommended Practice Manual: Lighting for Exterior Environments (www.iesna.org) for requirements for partially or fully shielded exterior lighting 4. 2. Light trespass is unwanted stray light shining across property boundaries. Any light fixture installed on a property must direct and shield light coming from the fixture so that the light source is not directly visible from any adjacent property. Lighting must focus downward, eliminating direct upward light and reducing spill light. 3. Glare is the physical sensation caused by artificial light that is brighter than one s adapted surroundings. Glare is produced by a bare light shining directly into the eyes of the observer. 4. Excessive rooftop lighting that contributes to light pollution is not permitted. Architectural illumination may be permitted in accordance with the following performance specifications: Shield exterior light fixtures to prevent light trespass. Architectural illumination is turned off year round from 11pm - 5am using an automatic device. 5. After hours override may be provided by a manual or occupant sensing device provided that the override lasts no more than 30 minutes. 6. Openings in the building envelope, transparent or translucent, include all fenestration (windows, doors, skylights, curtain walls). Provide shielding with less than 10% transmittance overnight. 5 7. For details on ways to make buildings better for birds including lighting, building operations and site management, refer to the Bird-Friendly Development Guidelines 6. EC 6.1 Install exterior light fixtures that are shielded to prevent glare and/or light trespass onto any neighbouring properties. EC 6.2 No up-lighting from exterior light fixtures unless otherwise permitted through a heritage designation. Fixtures that effectively project light downwards Building automation systems Task or workstation lighting 4 Unfortunately, IESNA does not deal with the issue of glare. The IESNA recommended levels may be somewhat excessive. Notice that Glare and light trespass are used in this section (1) and then defined in 2 and 3. 5 Good attempt to limit spill light, but might be better by specifying the maximum luminance of the building windows (an approach used by the CIE standard.) Otherwise the spill light depends on the intensity of the interior light, which is not specified here. 6 See section 4, page 3 of this document. 2

3.2 Low-Rise Residential http://www.toronto.ca/planning/environment/pdf/lr_res_tech.pdf (Similar to section A above, Low Rise Non-Residential.) EC 6.1 No up-lighting from exterior light fixtures. EC 6.2 Install exterior light fixtures that are shielded to prevent glare and/or light trespass onto any neighbouring properties Occupancy sensors/timers for exterior lighting 3.3 Mid to High Rise (4 storeys or greater, all uses) http://www.toronto.ca/planning/environment/pdf/mr_hr_tech.pdf Pedestrian scaled lighting must be directed downward and includes fixtures such as bollards or lower-scale pole fixtures along pedestrian routes AQ 3.4 Use pedestrian-specific lighting directed onto sidewalks, pathways, entrances and outdoor waiting areas. (Similar to sections A and B above.) Fixtures that effectively project light downwards Occupancy sensors in parking structures Building automation systems 4 Bird Friendly Development Guidelines http://www.toronto.ca/lightsout/pdf/development_guidelines.pdf Birds in urban areas, especially during migrations, are disoriented by misleading images of modern buildings and light pollution. Pages 19 to 26 are an excellent introduction to the subject of light pollution. Pages 25 and 26 show Preferred and Discouraged Lighting fixtures. 5 City of Toronto Accessibility Design Guidelines http://www.toronto.ca/parks/pdf/engagement/accessibility_guidelines.pdf 3

Lighting for Exterior Areas not including roads Exterior lighting should be designed generally in accordance with I.E.S.N.A. (Illuminating Engineering Society of North America) standards, in all public thoroughfares and along all pedestrian routes to ensure safe access for persons with disabilities at sidewalks, bus stops, or parking areas leading to public facilities or amenities. Lighting levels of 100 lux. (10 ft. candles) measured at the ground of all accessible pedestrian entrances are recommended as an aid to persons with visual disabilities. At frequently used pedestrian routes (including paths, stairs, and ramps) recommended lighting levels should be 30 lux. (3 ft. candles) 7. In accessible parking areas, lighting levels are recommended to be a minimum of 50 lux (5 ft. candles) at accessible parking spaces and along accessible routes from areas of parking to accessible entrances. Lighting sources should be selected and located at, or beside steps and stairs, to ensure clear definition of treads, risers, and nosings. All lighting over pedestrian routes should be evenly distributed, provide areasonable colour spectrum, and minimize cast shadows for persons with low vision. Supplementary lighting should be provided to highlight all key way-finding signage. Lighting standards or posts should be mounted to one side of pedestrian walkways so as not to inhibit free movement of persons using mobility aids. Low-level lighting standards should be tall enough to clear normal snow accumulation heights. Overhead light fixtures should be mounted on standards that ensure clear headroom of 2030 mm is available, below fixtures or supports, as an aid to persons with visual limitations. Lighting of landscape on special site features should be designed and installed to minimize direct glare to both pedestrians and building users. This does not include lighting for roads and expressways. The Transportation Division of Works & Emergency Services Department is currently developing a Lighting Master Plan which will incorporate street lighting. It is anticipated that this Master Plan will be completed by the end of 2004 8. Lights below 1525 mm illuminate surface only and must not glare into people s eyes 9. 6 City of Toronto, Sign Bylaw, No. 196-2010 http://www.toronto.ca/legdocs/bylaws/2010/law0196.pdf 694-18. Illumination A. No first party sign shall be illuminated at any time when a smog alert is in effect. B. All first party signs shall cease to be illuminated within four hours of the issuance of the smog alert. C. No sign shall be illuminated between the hours of 11:00 p.m. and 7:00 a.m. except where: 1. The sign is a first party sign associated with a lawful business which operates during this period and only while the business is actually in operation; or 2. The sign is located in the Downtown Yonge Street Special Sign District, the Dundas Square Special Sign District, or the Gardiner Gateway Special Sign District. 7 Both these levels are very high, considering that sidewalks are normally lit to about 3 lux. Notice that these are recommendations, not requirements. 8 Apparently, this was never completed. There is no such document on the web. 9 Designers of the glare-producing bollards at the Ontario Science Centre please take note. 4

E. Unless otherwise expressly prohibited by this chapter, all signs may be illuminated provided the following requirements are met: 1. The sign shall not be up-lit, 2. The light shall not project onto any adjacent premises located in an R, RA, CR, I, or OS sign district 10 ; 3. The illumination shall not increase the light levels within 10.0 metres of all points of the sign face by more than 6.5 lux above the ambient lighting level; 4. The illumination shall not exceed 5,000 nits 11 during the period between sunrise and sunset; and 5. The illumination shall not exceed 500 nits during the period between sunset and sunrise. 10 These districts are Residential, Commercial Residential, Institutional or Open Space. See page 21 of the Bylaw. 11 One nit is equal to 1 candela per square metre. 5